- All
- Favorite
- Popular
- Most rated
| Brand | DLAB |
|---|---|
| Model | TC1000-G-Pro |
| Instrument Type | Gradient PCR Thermal Cycler |
| Sample Capacity | 96 × 0.2 mL tubes / 12 × 0.2 mL strips / 0.2 mL 96-well plates |
| Block Temperature Range | 0–105 °C |
| Heat Lid Temperature Range | 30–115 °C |
| Temperature Display Accuracy | ±0.1 °C |
| Temperature Control Accuracy (at 55 °C) | ±0.1 °C |
| Temperature Uniformity (at 55 °C) | ±0.2 °C |
| Max Ramp Rate | 5 °C/sec |
| Gradient Range | 30–105 °C |
| Gradient Span | 1–42 °C |
| Temperature Control Mode | Block- or Tube-based |
| Block Material | Anodized Aluminum |
| Display | 7″ LCD (1024 × 600) |
| Input Method | Touchscreen + PC-based host software |
| Communication Interfaces | USB 2.0, Wi-Fi (IEEE 802.11 b/g/n) |
| Power Supply | 100–120 V / 200–240 V, 50/60 Hz |
| Dimensions (L×W×H) | 280 × 370 × 250 mm |
| Weight | 9.5 kg |
| Data Retention (Power Loss Recovery) | >20,000 cycles (USB flash memory) |
| Brand | DLAB |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Gradient PCR Thermal Cycler |
| Sample Capacity | 96-well format (0.2 mL tubes, 8×12 strips, or full 96-well plates) |
| Temperature Range | 4–105°C (sample block), 30–110°C (heated lid) |
| Temperature Accuracy | ±0.3°C at 55°C |
| Temperature Uniformity | <0.3°C at 55°C |
| Max Ramp Rate | 5°C/sec |
| Gradient Range | 30–99°C |
| Gradient Span | 1–42°C |
| Block Material | Anodized aluminum |
| Display | 7-inch color TFT-LCD (800×480 resolution) |
| Control Interface | Capacitive touch screen |
| Program Storage | 16 folders × 16 programs/folder |
| Power Input | 100–120 V / 200–240 V, 50/60 Hz |
| Dimensions (L×W×H) | 280 × 370 × 250 mm |
| Weight | 11 kg |
| Power Failure Protection | Yes |
| Temperature Display Resolution | ±0.1°C |
| Brand | DLAB |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | TC1000-S |
| Sample Throughput | 96-well format |
| Temperature Accuracy | ±0.3 °C |
| Well-to-Well Temperature Uniformity | <0.3 °C |
| Brand | DLAB |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Yes |
| Instrument Type | Real-Time Fluorescence Quantitative PCR System |
| Sample Throughput | 16-well (2×8 configuration) |
| Max Heating/Cooling Rate | 6.0°C/s |
| Temperature Accuracy | ±0.2°C |
| Well-to-Well Temperature Uniformity | ±0.2°C @ 60°C |
| Excitation Source | Monochromatic High-Efficiency LED |
| Detection Device | High-Precision MPPC (Silicon Photomultiplier) |
| Scanning Mode | Linear Fast Well-by-Well Scan |
| Fluorescence Channels | Dual-Channel Standard (FAM/SYBR & VIC/HEX) |
| Sensitivity | Single-Copy Gene Detection |
| Dynamic Range | 10 orders of magnitude |
| Analysis Modes | Ct Value Analysis, Absolute Quantification |
| Reaction Volume | 10–50 µL |
| Compatible Vessels | 0.2 mL transparent single tubes or 8-tube strips |
| Power Input | 100–240 V AC |
| Dimensions (W×D×H) | 225 × 270 × 132 mm |
| Weight | 4 kg |
| Brand | DLAB |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Real-Time Fluorescent Quantitative PCR System |
| Model | Accurate 96-X4 / Accurate 96-X6 |
| Sample Throughput | Dual-Channel / Quad-Channel (X4) or Hexa-Channel (X6) |
| Excitation Source | 4 (X4) or 6 (X6) High-Efficiency Monochromatic LEDs (>100,000 h lifetime) |
| Fluorescence Detection Channels | 4 or 6 independent optical channels |
| Supported Dyes | FAM/SYBR Green I, VIC/HEX/JOE/TET, ROX/Texas Red, Cy5, NED/TAMRA/Cy3 |
| Detector | High-Sensitivity Silicon Photomultiplier (MPPC) |
| Read Position | Top-Reading Configuration |
| Sensitivity | Single-Copy Gene Detection |
| Excitation Range | 455–680 nm |
| Emission Detection Range | 510–730 nm |
| Dynamic Range | 10 decades (1–10¹⁰ copies) |
| Resolution | Discrimination of 1.33-fold copy number difference in singleplex assays |
| Sample Capacity | 96-well standard plate |
| Reaction Volume | 10–50 µL |
| Temperature Range | 4–100 °C |
| Thermal Lid | Electronically Controlled Adjustable Lid (RT to 115 °C) |
| Temperature Gradient | 12-column gradient with adjustable ΔT from 1–40 °C |
| Heating/Cooling Rate | Up to 6 °C/s |
| Temperature Accuracy | ≤ ±0.2 °C |
| Temperature Uniformity | ≤ ±0.2 °C across block |
| Thermal Control Architecture | Six Independent Peltier Modules |
| Analysis Modes | Absolute Quantification, Relative Quantification, Qualitative Detection, End-Point Fluorescence Analysis, Melting Curve Analysis, High-Resolution Melting (HRM), Genotyping |
| Data Export Formats | CSV, Excel (.xlsx), TXT |
| Report Output | PDF, Printable Graphs & Tables, Customizable Templates, Preloaded Report Modules |
| Software Compliance | Audit Trail, User Access Levels, Electronic Signature Support (aligned with FDA 21 CFR Part 11 principles for GLP/GMP environments) |
Show next