Empowering Scientific Discovery

Dandong Aolong Radiation Instrument Group Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAolong
OriginLiaoning, China
Manufacturer TypeOEM Manufacturer
Country of OriginChina
ModelT6777
PriceUpon Request
Input Power3 kW
Input Voltage220 V AC ±10%, 50 Hz
Tube Voltage RangeContinuously Adjustable
Tube Voltage Stability±1%
Tube Current Range1–3 mA, Continuously Adjustable
Operating Mode1:1 Duty Cycle
Cooling MethodForced Air Cooling
Operating Ambient Temperature−30 °C to +40 °C
Source-to-Film Distance (SFD)600 mm
Controller Weight8 kg
Radiographic Film DensityD ≥ 1.5
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAolong
OriginLiaoning, China
Manufacturer TypeOEM Manufacturer
Regional ClassificationDomestic (PRC)
ModelLaser Positioning Device for X-ray Radiographic Inspection Systems
Price RangeUSD 28,000 – 70,000
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAolong
OriginLiaoning, China
Manufacturer TypeOEM Manufacturer
Country of OriginChina
ModelT5777
Price RangeUSD 28,000 – 71,000
Power Supply220 V ±10%
Input Power3.5 kW
High Voltage Range100–300 kV
Tube Current Range1–5 mA
Max Penetration Thickness (A3 Steel)48 mm
Film DensityD = 1.5 ±0.1
Cooling MethodForced Air Cooling
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAolong
OriginLiaoning, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelAL-NP-6010A
Price RangeUSD 280,000 – 425,000
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAolong
OriginLiaoning, China
Manufacturer TypeOEM Manufacturer
Regional CategoryDomestic (China)
ModelT4776, T4777
Price RangeUSD 28,000 – 70,000
Power Supply50 Hz AC 220 V ±10%
Input Power3.5 kW (generator ≥5 kW required)
Tube VoltageContinuously Adjustable
Tube Voltage Stability±1%
Tube Current5 mA
Duty Cycle1:1 (continuous operation mode)
Cooling MethodForced Air Cooling
Operating Ambient Temperature−30 °C to +40 °C
Focal Spot-to-Film Distance600 mm
Controller Weight10 kg
Film DensityD ≥ 1.5
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAolong
OriginLiaoning, China
Manufacturer TypeDirect Manufacturer
Regional CategoryDomestic (China)
Model SeriesChiRad
Price RangeUSD 140,000 – 280,000 (FOB)
Focal Spot Size5.5 mm
Radiation Beam Angle40°
Maximum Penetration30 mm Fe (Iron Equivalent)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAolong
OriginLiaoning, China
Manufacturer TypeManufacturer
Country of OriginChina
ModelYX-2C
Price RangeUSD 140,000 – 280,000
Input PowerAC 220 V, 50 Hz, 0.5 kW
X-ray TubeCu anode, air-cooled, 30 kV, 0–5 mA
DetectorGeiger–Müller counter
Time Constants0.1 s, 0.4 s, 3 s
Angular Rangeθ = −5° to +55°, 2θ = −10° to +110°
Mechanical Angular Resolution1° (on scale ring for both θ and 2θ)
Digital Display Resolution10 arcseconds
Angular Accuracy±30 arcseconds
Slit Apertures4′, 5′, 6′
Beam ShutterManual
Display FormatDegrees, Minutes, Seconds
Angle SettingProgrammable digital angle preset
Dimensions (L×W×H)1140 × 650 × 1030 mm
Weight150 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAolong
OriginLiaoning, China
Manufacturer TypeOEM Manufacturer
Country of OriginChina
ModelAL-DR-270A
Price RangeUSD 140,000 – 280,000
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAolong
OriginLiaoning, China
Manufacturer TypeOEM Manufacturer
Country of OriginChina
ModelPortable X-ray DR Imaging System
Price RangeUSD 140,000 – 280,000
X-ray Tube Voltage160 kV (120 kV optional)
X-ray Tube Currentup to 5 mA
System Weight10 kg
Operating Temperature−20 °C to +60 °C
Image Area130 mm × 130 mm
Pixel Pitch85 µm
Spatial Resolution4.0 line pairs/mm
Core ComponentsX-ray generator, flat-panel detector (indirect conversion), ruggedized laptop workstation
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAolong
Cooling Capacity4000 W
Flow Rate14 L/min
Power SupplySingle-phase 220 V ±10%, 50/60 Hz
Current Draw2.3 A
Noise Level58 dB(A) at 1 m
Operating Temperature+5 °C to +35 °C
Storage Temperature−25 °C to +70 °C (oil-free)
Relative Humidity20–80% RH (non-condensing)
Maximum System Pressure60 bar
OriginLiaoning, China
ManufacturerAolong (OEM producer)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAolong
OriginLiaoning, China
Manufacturer TypeManufacturer
Origin CategoryDomestic
ModelAL-DR-300B
Price RangeUSD 140,000 – 280,000
Max. X-ray Energy350 kV
Tube Current5 mA
Focal Spot Size2.0 mm
Beam Divergence Angle40°
Sensitivity≤1.5%
Detector TypeAmorphous Silicon (a-Si), Custom-Optimized for Variable-Frequency X-ray Source
Active Imaging Area35 × 21 cm
Pixel Pitch140 µm
Spatial Resolution3.2 LP/mm
A/D Conversion16-bit
Image Acquisition Time1 s (wired), 2.5 s (wireless)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAlong
OriginLiaoning, China
Manufacturer TypeOEM Manufacturer
Country of OriginChina
ModelXXG-3005ZH
Voltage Range50–300 kV
Current Range1–5 mA
Focal Spot Size2.5 × 2.5 mm
Radiation Beam Angle40° ± 5°
Duty Cycle1:1 (Continuous Operation Mode)
Max. Penetration in A3 Steel50 mm
Generator Weight28 kg
Generator Dimensions345 × 345 × 670 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAlong
OriginLiaoning, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelTX-160
Voltage Range10–160 kV / 10–225 kV
Current Range0.1–1.0 mA
Beam Divergence Angle~160°
Max. Output Power60 W
Standard Target Power10 W
Focal Spot Size<1 µm
Focus-to-Object Distance (FOD)0.25 mm
Geometric Magnificationup to 2800×
Filament MaterialTungsten
Vacuum SystemDual-Stage High/Low Vacuum Pump
Optional AccessoriesHigh-Voltage Generator, HV Cable, X-ray Tube Controller
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAlong
OriginLiaoning, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelXXG-3005ZH, XXG-2505ZH
Power Supply220 V ±10%
Input Power3.5 kW
High Voltage Range50–300 kV (continuously adjustable)
Tube Current Range1–5 mA
Max. Penetration Thickness (A3 steel)60 mm
Film DensityD = 2.0 ± 0.1
Cooling MethodForced Air Cooling
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAolong
OriginLiaoning, China
Manufacturer TypeManufacturer
Origin CategoryDomestic
ModelMXV100
Price¥190,000
X-ray Generator Input Voltage1-phase 230 VAC
Output Power32 kW
Operating Frequency400 kHz
Tube Voltage Range40–150 kV (1 kV step)
Tube Current Range20–400 mA
mAs Range0.1–500 mAs
Exposure Time Range1–6300 ms
Focal Spot Size0.6 / 1.2 mm
Anode Heat Capacity150 kHU (111 kJ)
Anode Target Angle12°
Animal Table Dimensions120 × 60 × 90 cm (L×W×H)
Table MaterialCarbon Fiber
Collimator Field Size (max)48 × 48 cm at SID = 100 cm
Light Field Duration60 s
Laser PointerCrosshair type
Collimator AdjustmentManual knob
Grid Size17″ × 17″ (43 × 43 cm)
Grid Ratio8:1
Grid Line Density103 lines/inch
Grid Focus Distance100 cm
Arm Vertical Travel74.5 cm
Arm Horizontal Travel50 cm
Tube Rotation Angle±90°
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0