- All
- Favorite
- Popular
- Most rated
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | X-Ray Multi-Function Automated Positioning Trolley |
| Price Range | USD 28,000 – 70,000 |
| Max. Vertical Travel | 3 m / 5 m (selectable) |
| Motion Axes | 4-axis motorized (X/Y/Z + rotational tilt) |
| X-ray Tube Mount Compatibility | Universal interface for portable X-ray sources (ISO 10962-compliant flange dimensions) |
| Control | Integrated touchscreen HMI with programmable motion presets and emergency stop circuitry |
| Safety Compliance | Meets GB/T 18871-2002 (Chinese radiation protection standard), IEC 61000-6-4 EMC immunity |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | Multi-Function X-ray Foreign Object Detection System |
| Quotation | Upon Request |
| Voltage | 150 kV |
| Power | 300 W |
| Display | 21-inch color LCD monitor |
| Max Sample Width | 380 mm |
| Max Sample Height | 220 mm (customizable) |
| Conveyor Belt Width | 410 mm |
| Conveyor Speed | 3–10 m/min |
| Max Load Capacity | 5 kg |
| Standard Detection Functions | Seal integrity check, missing item detection, shielding function |
| Power Supply | AC 220 V ±10%, 50/60 Hz |
| Operating Environment | 0–35 °C |
| Housing Material | Steel + stainless steel |
| Radiation Leakage | ≤1 µSv/h |
| Safety Features | Multi-level interlock system |
| Optional Detector | Dual-energy digital X-ray detector for material discrimination |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Product Category | Domestic Industrial Micro-CT System |
| Model | X-ray In-Line Casting Inspection System |
| Pricing | Available Upon Request |
| Tube Voltage | 20–450 kV |
| Tube Current | 0.1–20 mA |
| Repeatability | ±0.01% |
| High-Voltage Rise Time | 0.1–0.3 ms |
| Spatial Resolution | 16–60 lp/cm (depending on detector configuration) |
| Contrast Sensitivity | 1.2–1.5% |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | XYG-120 |
| Price | Upon Request |
| Tube Voltage | 40–160 kV |
| Tube Current | 0–2 mA |
| Focal Spot Size | 30 µm – 1.2 mm |
| Spatial Resolution | 18–32 LP/cm |
| Manipulator | Motorized X-Y-Z translation with ±360° continuous rotation around Z-axis |
| Overall Dimensions | 2090 × 1100 × 1700 mm |
| Image Processing | Real-time zoom, digital magnifier, dynamic video recording/playback, noise-reduced static/dynamic frame storage, pseudo-color mapping, emboss enhancement, horizontal/vertical mirroring, region-of-interest (ROI) grayscale adjustment, window-level/width control, integrated relational database |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | X-RAY NDT |
| Price Range | USD 28,000 – 70,000 |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | AL-Y3500 |
| Price Range | USD 28,000 – 70,000 |
| Instrument Type | High-Resolution X-ray Diffractometer |
| Configuration | Floor-Standing |
| Angular Resolution | Better than 0.0001° (2θ) |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | XYG-4503 |
| Pricing | Upon Request |
| X-ray Tube Voltage | 20–450 kV |
| Focal Spot Size | 1 µm – 0.4 mm |
| Spatial Resolution | 0.5 µm |
| Density Resolution | 0.3–0.5% |
| Scan Geometry | Cone-Beam CT |
| Detector Options | Digital Flat-Panel Detector or Image Intensifier |
| Reconstruction Speed | ≤0.2 s per 1024×1024 pixel slice |
| Planar CT Mode Voltage Range | 20–225 kV |
| Planar CT Focal Spot | 1–5 µm |
| Planar CT Spatial Resolution | 0.6–50 µm |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Powder X-ray Diffractometer |
| Model | AL-27min |
| X-ray Tube | Metal-ceramic Cu anode (2.4 kW), focal spot 1×10 mm |
| Generator Power Options | 600 W (40 kV / 15 mA) or 1200 W (40 kV / 30 mA) |
| Voltage/Current Stability | ±0.005% |
| Goniometer Configuration | Horizontal θs–θd geometry, radius 150 mm |
| Angular Range (θs/θd coupled) | –3° to 150° |
| Minimum Step Size | 0.0001° |
| Angular Reproducibility | ±0.0005° |
| Maximum Goniometer Speed | 1500°/min |
| Detector Options | Sealed proportional counter or high-speed 1D semiconductor array |
| Energy Resolution | <25% (FWHM at Cu Kα) |
| Maximum Linear Count Rate | ≥5×10⁵ cps (proportional), ≥9×10⁷ cps (1D semiconductor) |
| Sample Changer Capacity | Up to 6 samples per loading |
| Radiation Shielding | Lead + lead-glass interlocked shutter |
| Overall Instrument Stability | ≤0.1% (RSD over 8 h) |
| Dimensions (W×D×H) | 600×410×670 mm |
| Operating System | Windows 7 (dedicated Dell commercial laptop) |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | CT225 |
| Pricing | Upon Request |
| X-ray Tube Voltage Range | 20–225 kV |
| Minimum Focal Spot Size | 1 µm |
| Detector Pixel Resolution | 100 µm |
| Maximum Sample Dimensions | Ø300 mm × H500 mm (customizable) |
| Maximum Sample Weight | 50 kg |
| Achievable 3D Spatial Resolution (Detail Detectability) | ≤0.25 µm |
| Rotational Axis Accuracy | 4-axis precision motion system |
| System Weight | 2600 kg |
| Ambient Dose Rate | <1 µSv/h (at 1 m from enclosure) |
| X-ray Source Type | Open-tube microfocus with long-life cathode architecture |
| Reconstruction Capability | Real-time iterative and filtered back-projection (FBP) CT volume reconstruction |
| Artifact Correction | Ring artifact suppression, beam hardening correction, scatter compensation |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | YX-2H8A |
| Price Range | USD 2,800 – 14,000 |
| Input Power | 220 V AC, 50 Hz, 0.5 kW |
| X-ray Tube | Cu anode, air-cooled, 30 kV, 0–5 mA |
| Detector | Geiger-Müller counter |
| Time Constants | 0.1 s, 0.4 s, 3 s |
| Angular Range | θ = −5° to +55°, 2θ = −10° to +110° |
| Angular Resolution | 1 arcsecond (1″) |
| Minimum Scale Reading | 1° on mechanical scale (2θ and θ) |
| Digital Display | Degrees, minutes, seconds |
| Adjustable Angle Setting | Programmable digital angle positioning |
| Collimator Slits | 4′, 5′, 6′ |
| Beam Shutter | Manual |
| Display Type | Digital angular readout |
| Overall Angular Accuracy | ±30″ |
| Dimensions (L×W×H) | 1160 × 700 × 1380 mm |
| Weight | 170 kg |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | AOLONG2 |
| Pricing | Upon Request |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | ChiRad 160D |
| Price | Upon Request |
| Tube Voltage | 30–160 kV |
| Tube Current | 0.1–5 mA |
| Maximum Tube Power | 600 W |
| Beam Divergence Angle | 40° |
| Maximum Irradiation Field Diameter | 30 cm |
| Source-to-Object Distance | 40 cm |
| Exposure Time Range | 10 s – 180 min |
| Input Voltage | 100–230 VAC ±10%, 50–60 Hz |
| Cooling System | Closed-loop Liquid Cooling |
| Sample Rotation Stage | Motorized, Programmable Rotation |
| Integrated Dosimetry | Real-time Dose Monitoring Sensor |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Manufacturer |
| Model | YXL-2 |
| Power Supply | 220 V AC, 50 Hz, 0.3 kW |
| X-ray Tube | Cu anode, air-cooled |
| Detector | Geiger–Müller counter |
| Time Constants | 0.1 s, 0.4 s, 3 s |
| Angular Range | θ = −10° to +50°, 2θ = −10° to +100° |
| Angular Resolution | 1° (scale), 1″ / 3″ (digital readout) |
| Angular Accuracy | ±10″ |
| Optical Shutter | Manual |
| Display | Digital angle readout with peak-hold analog meter |
| Main Frame | YX-300 base unit |
| Sticky Board Dimensions | 330 × 200 × 20 mm or 250 × 250 × 20 mm |
| Crystal Rod Thickness Options | 7 mm, 8 mm, 9 mm, 10 mm |
| Max Adhesive Layers | 5 (standard), 6 (optional) |
| Layer Adjustment Method | Precision-matched cushion bars |
| Board Fixation | Permanent magnetic clamping |
| Board Translation Mechanism | Imported high-precision linear rail system |
| Weight | 180 kg |
| Overall Dimensions | 1140 mm (L) × 650 mm (W) × 1100 mm (H) |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic |
| Model | AL-DR-270 |
| X-ray Tube Voltage | 270 kV |
| Penetration Capability | 13 mm steel equivalent |
| Detector Type | Amorphous Silicon Flat Panel Detector |
| Effective Imaging Area | 350 × 430 mm |
| Pixel Pitch | 140 µm |
| Spatial Resolution | 3.2 lp/mm |
| A/D Conversion | 16-bit |
| Image Acquisition Time | 1 s (wired), 2.5 s (wireless) |
| Focal Spot Size | 3 mm |
| Pulse Width | 50 ns |
| Pulse Rate | 15 Hz |
| Output Dose | 2.6–4.0 mR/pulse (measured at 30.5 cm / 12 in from source) |
| Dimensional Measurement Accuracy | ±1 mm |
| Radiation Safety Compliance | Meets IEC 61331-1 and GBZ 138–2019 requirements for portable pulsed X-ray devices |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | YX-2H8 |
| Price | Upon Request |
| Input Power | 220 V AC, 50 Hz, 0.3 kW |
| X-ray Tube | Cu anode, air-cooled, 30 kV, 0–5 mA |
| Detector | Geiger-Müller counter |
| Time Constants | 0.1 s, 0.4 s, 3 s |
| Angular Range | θ = −10° to +50°, 2θ = −10° to +100° |
| Angular Resolution (digital display) | 10 arcseconds |
| Angular Accuracy | ±30 arcseconds |
| Slit Apertures | 4′, 5′, 6′ |
| Optical Shutter | Manual |
| Display | Digital angle readout |
| Dimensions (L×W×H) | 1150 mm × 665 mm × 1100 mm |
| Weight | 170 kg |
| Sample Capacity | 1–30 kg, diameter up to 8 inches (203 mm), compatible with sapphire, silicon, and other single-crystal materials |
| Goniometer Options | YA, YB, YD, YE interchangeable sample stages |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | AL-DR-300C |
| Configuration | Portable |
| Beam Directionality | Directional |
| Focal Spot Size | 2.5 mm |
| Radiation Angle | 40° + 5° (Total Coverage: 45°) |
| Maximum Penetration | 60 mm Fe-equivalent |
| Max. Tube Voltage | 320 kV |
| Tube Current | 5 mA |
| Detector Type | Amorphous Silicon (a-Si) Flat Panel Detector (Custom-optimized for Variable-Frequency X-ray Source) |
| Active Detector Area | 13 cm × 13 cm |
| Pixel Pitch | 85 µm |
| Spatial Resolution | 4 LP/mm |
| A/D Conversion | 16-bit |
| Sensitivity | ≤1.5% (EN 13297:2011 compliant) |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | X-Ray Pipeline Crawler |
| Price Range | USD 28,000 – 70,000 |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Model | CHIRAD |
| Max. Operating Voltage | 160 kV |
| Max. Power Output | 4000 W |
| SSD Range | 20–70 cm (customizable chamber) |
| Filter Configuration | Standard 2 mm Al + 0.3 mm Cu drawer-type filter set |
| Dose Uniformity | ≥95% |
| Exposure Time Range | 1–9999 s |
| Ambient Dose Rate (5 cm from housing) | <20 µR/h |
| Sample Compatibility | Cells, tissues, organs, bacteria, mice, rats, nanomaterials, food, seeds, insects |
| Environmental Control Option | Integrated biological incubator module |
| Safety Compliance | Meets GBZ 125–2022 and GB 18871–2002 radiation safety standards |
| Data Export | Excel-compatible CSV output |
| Touch Interface | 15.6″ industrial capacitive touchscreen with real-time ionization chamber dose monitoring |
| Shielding | Self-shielded irradiation chamber with dual-redundant interlock system (door, beam gate, emergency stop) and audible/visual fault alerts |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | MF-2505 |
| Price Range | USD 14,000–28,000 |
| Input Voltage | 220 V ±10% |
| Input Power | 3.5 kW |
| Tube Voltage Range | 50–250 kV (continuously adjustable) |
| Tube Current | 5 mA |
| Max. Penetration Thickness (A3 steel) | 48 mm |
| Film Density | D = 1.5 ±0.1 |
| Cooling Method | Forced Air Cooling |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | Micro CT100 |
| Price | Upon Request |
| X-ray Tube | 40–90 kV, 50 W, focal spot size 15 µm @ 6 W |
| Additional Filters | 6 metal filters (automated selection) |
| Detector | CMOS flat-panel detector, 1536 × 1944 pixels, 14-bit depth |
| Spatial Resolution | 2.0–44.9 µm (reconstruction-dependent) |
| Effective Field of View (FOV) | 80 × 200 mm |
| Voxel Size (Reconstruction) | down to 2 µm isotropic |
| Scan Time | 2 s (high-speed mode), 20 s (standard mode) |
| Dimensions | 880 × 1500 × 1500 mm (W × D × H) |
| Weight | < 950 kg |
| Radiation Safety | < 1 µSv/h at 10 cm from enclosure surface during operation |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | AL-CT1010 |
| X-ray Source | Reflected-anode microfocus tube |
| Max. Tube Voltage | 225 kV |
| Focal Spot Size | ≤3 µm |
| Max. Anode Power | 350 W |
| Max. Target Power | 300 W |
| Spatial Resolution (Detail Detectability) | ≤2 µm |
| Detector | Amorphous silicon flat-panel detector |
| Pixel Count | 1536 × 1920 |
| Pixel Pitch | 127 µm |
| Active Area | 250 mm × 200 mm |
| Gray Scale Resolution | 16-bit |
| Limiting Resolution | 3.94 lp/mm |
| Cooling Method | Air-cooled |
| Filament Design | Plug-and-play, user-replaceable |
| X-ray Tube Lifetime | >8 years |
| Brand | AoLong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Region Classification | Domestic (China) |
| Model | ALYX-600A |
| Pricing | Upon Request |
| Input Power | 220 V AC, 50 Hz, 0.25 kW |
| X-ray Tube | Cu anode, fan-cooled, grounded anode |
| Max. Tube Voltage/Current | 30 kV / 5 mA (continuously adjustable) |
| Detector | Proportional counter (max. operating voltage: DC 1000 V) or scintillation detector (max. operating voltage: DC 1200 V) |
| Time Constant | 2 settings (Fast: 1, Slow: 2) |
| Angular Range | 2θ = −10° to 120° |
| Angular Resolution | 1 arcsecond (″) — digital display in ° ′ ″ format |
| Angular Pre-setting | Digital numerical input with real-time feedback |
| Primary Beam Shutter | Motorized, automatic |
| Radiation Shielding | Fully enclosed lead-lined cabinet conforming to GBZ 117–2020 and IEC 61000-6-3 |
| Display Panel | Dual-channel LCD showing real-time angle and X-ray intensity |
| Overall Orientation Accuracy | ±15″ or ±30″ (verified using NIST-traceable quartz reference crystal) |
| Dimensions (L×W×H) | 1132 × 642 × 1460 mm |
| Weight | 300 kg |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | Desktop Micro-CT (μCT) |
| Pricing | Upon Request |
| X-ray Tube Voltage | 20–90 kV |
| Focal Spot Size | 5 µm |
| Density Resolution | 0.3–0.5% |
| Scan Geometry | Cone-Beam CT (CBCT) |
| Imaging Modes | 2D Radiography & 3D Tomographic Reconstruction |
| Real-Time DR Imaging Capability | Yes |
| Brand | AOLONG |
|---|---|
| Model | BatteryCT |
| Type | Industrial Micro-Computed Tomography System |
| Origin | Liaoning, China |
| Manufacturer | OEM Producer |
| X-ray Max Power | 320 W |
| X-ray Max Voltage | 225 kV |
| X-ray Max Current | 3 mA |
| Focal Spot Size | 4 µm |
| Beam Divergence Angle | 30° |
| Flat-Panel Detector Pixel Pitch | 139 µm |
Show next