| Brand | Amptek |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MINI-X |
| Price | Upon Request |
| Target Material | Silver (Ag) or Gold (Au) |
| Target Thickness | Ag = 0.75 µm |
| Tube Voltage Range | 10–50 kV |
| Tube Current Range | 5–200 µA |
| Max Continuous Output Power | 4 W |
| Window Material | Beryllium (Be), grounded |
| Window Thickness | 127 µm |
| Focal Spot Size | ~2 mm |
| Output Cone Angle | 120° |
| Cooling Method | Air-cooled |
| High Voltage Stability | <0.1% |
| Leakage Radiation (5 cm, safety plug installed) | <5 µSv/h |
| Input Voltage | 12 VDC (AC adapter included) |
| Control Interface | USB (mini-USB connector, cable included) |
| Settling Time | <1 s typical |
| Weight | 360 g |
| Operating Temperature | −10 °C to +50 °C |
| Storage Temperature | −25 °C to +60 °C |
| Relative Humidity | 30–90% non-condensing |
| Safety Features | External hardware interlock, flashing LED, audible beeper |
| Software | Mini-X Control GUI + Mini-X API for custom integration |
| Warranty | 1 year or 2000 operating hours, whichever occurs first |
| Brand | Amptek |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | X-123 |
| Price | Upon Request |
| Detector Type | Si-PIN |
| Cooling | 2-Stage Thermoelectric Cooler |
| Active Area | 5–25 mm² |
| Thickness | 300–680 µm |
| Energy Resolution | 145–260 eV FWHM @ 5.9 keV |
| Optimal Energy Range | 1–40 keV |
| Max Count Rate | 2 × 10⁵ cps |
| Power Consumption | 1.2 W |
| Dimensions | 70 × 100 × 25 mm (2.7 × 3.9 × 1 in) |
| Weight | 180 g (6.3 oz) |
| Interface | USB & RS-232 |
| Compliance | RoHS/WEEE |
| Brand | Amptek |
|---|---|
| Origin | USA |
| Model | XR-100CR |
| Detector Type | Si-PIN |
| Active Area | 6–25 mm² |
| Silicon Thickness | 500 µm |
| Energy Resolution | 145–230 eV FWHM @ 5.9 keV (⁵⁵Fe) |
| Be Window Thickness | 12.5 µm or 25 µm |
| Operating Temperature | ~−55 °C (thermoelectrically stabilized) |
| Power Consumption | <1 W total |
| Package | Hermetic TO-8 with beryllium window |
| Weight | 139 g |
| Certifications | UL 61010-1:2004, CAN/CSA-C22.2 No. 61010-1:2004, TUV CU 72072412 01 |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AquapHOx-TX |
| Pricing | Upon Request |
| Output | 4–20 mA (proportional to selected velocity range) |
|---|---|
| Accuracy | ±5% of full-scale output |
| Frequency Response | 2 Hz – 2 kHz (−3 dB) |
| Flatness | ±10% from 10 Hz – 1 kHz |
| Buffered Output | 100 mV/g (acceleration sensitivity) |
| Power Supply | 22–36 VDC via dual-conductor cable |
| Operating Temperature | −20 °C to +80 °C |
| Mounting | 1/4-28 UNC or M8 threaded stud |
| Weight (transmitter only) | 227 g |
| Compliance | Designed for industrial condition monitoring per IEC 61266-1 and ISO 10816-3 guidelines |
| Optional Accessories | CMSS 420LCD (local LCD display), CMSS 420LED (local LED display), CMSS 420BNC (buffered BNC output module) |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Pricing | Upon Request |
| Brand | Hamilton |
|---|---|
| Origin | Switzerland |
| Model | MICROLAB® 503A |
| Liquid Handling Principle | Positive Displacement Pipetting |
| Volume Range | 1 µL – 25 mL |
| Accuracy & Precision | NIST-Traceable |
| Programmability | Single-Method Storage |
| Interface | Touchscreen LCD Display |
| Footswitch Control | Yes |
| Compliance | Designed for GLP/GMP-relevant workflows |
| Sample Output Format | Direct dispensing into autosampler vials (down to 1000 µL final volume) |
| Brand | Hamilton |
|---|---|
| Origin | Switzerland |
| Model | MICROLAB® 530B |
| Liquid Handling Principle | Positive Displacement Pipetting |
| Volume Range | 1 µL – 25 mL |
| Accuracy & Precision | NIST-Traceable |
| Programmable Methods | 21 stored protocols |
| Interface | Touchscreen LCD with Footswitch Control |
| Compliance | Designed for GLP/GMP environments, supports audit-ready documentation |
| Brand | Jianhu |
|---|---|
| Origin | Shanghai, China |
| Model | JH / JH-4256 |
| Drop Height Range (Single-Arm) | 30–150 cm |
| Base Plate Dimensions | 120 × 140 cm (W × D) |
| Max Specimen Size | 100 × 80 × 100 cm |
| Impact Panel Size | 170 × 120 × 2 cm |
| Motor Power | 1.85 kW |
| Overall Dimensions (Single-Arm) | 170 × 120 × 230 cm |
| Drop Height Accuracy | ±1 cm |
| Levelness Tolerance of Drop Surface | ≤1 mm |
| Weight | 600 kg |
| Power Supply | AC 220 V, 50 Hz (Single-Arm) |
| Dual-Arm Height Range | 40–150 cm |
| Dual-Arm Load Capacity | ~60 kg |
| Dual-Arm Drive | Motorized height adjustment |
| Dual-Arm Motor Rating | 0.5 HP |
| Mobile Phone Tester Actuation | Pneumatic release mechanism |
| Compliant Standards | IEC 60068-2-32, GB/T 2423.8, JIS C 0044 |
| Brand | Jianhu |
|---|---|
| Model | JH-9008 |
| Drop Height Range | 300–1500 mm |
| Height Display | Digital |
| Height Accuracy | ±10 mm |
| Max Specimen Weight | 10 kg |
| Support Plate Dimensions | 220 × 200 × 12 mm |
| Impact Base Plate Dimensions | 550 × 650 × 20 mm |
| Overall Dimensions (approx.) | 650 × 560 × 2260 mm |
| Control Cabinet Dimensions (approx.) | 350 × 350 × 1000 mm |
| Height Adjustment | Motorized Drive |
| Drop Orientation | Face, Edge, Corner (Pneumatic Release) |
| Operating Pressure | ~0.8 MPa (8 bar) |
| Net Weight (approx.) | 70 kg |
| Power Supply | 220 VAC ±10% |
| Compliance Standard | GB/T 2423.8 |
| Brand | LabCompanion (Hongzhan) |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | LCD Series |
| Price | Upon Request |
| Temperature Range | −40 °C to +100 °C |
| Humidity Range | 20–98 %RH |
| Temperature Uniformity | ±1 °C |
| Humidity Uniformity | ±5 %RH |
| Door Configuration | Dual-front & dual-rear access doors |
| Viewing Window | 72 cm (W) × 152 cm (H), double-sided, anti-fog coated |
| Sample Mounting | Adjustable-angle LCD fixture (10″, 18″, 20″, 30″ |
| tilt angles | 0°, 30°, 45°, 60°) |
| Controller | Q8-901 Korean-imported color touchscreen PID controller with English/Chinese/Korean UI |
| Communication Interfaces | RS-232 & RS-485 (multi-unit daisy-chain capable) |
| Optional Data Logger | 256 MB CF card module with user-defined logging interval |
| Power & Safety Interlock | Integrated power supply interface with interlocked safety cutoff for DUT |
| [Brand | LabCompanion |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | Q8/UV Series |
| UV Lamps | UVA-340 / UVB-313 / UVA-351 |
| Irradiance Control | Optional (1.0 W/m² @ 340 nm, 1.1 W/m² @ 313 nm) |
| UV Temperature Range | 50–75 °C |
| Condensation Temperature Range | 40–60 °C |
| Test Capacity | Up to 48 specimens (75 × 150 mm) |
| Water Consumption | 8 L/day (distilled water) |
| Dimensions (W×D×H) | 137 × 53 × 136 cm |
| Weight | 136 kg |
| Power Supply | 1φ, 120 V/60 Hz (16 A) or 230 V/50 Hz (9 A), max. 1800 W |
| Compliance | ASTM G153, ASTM G154, ASTM D4329, ASTM D4587, ASTM D4799, SAE J2020, ISO 4892] |
| Key | Brand: Tianjin HengAo |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HDP-01A |
| Power Supply | 220 V / 110 V, 50 / 60 Hz |
| Max. Weighing Capacity | 3000 g |
| Weighing Resolution | 0.01 g |
| Dilution Time | <20 s (for 250 mL) |
| Dilution Range | 1/2 to 1/99 (inclusive) |
| Dilution Accuracy | >98% |
| Number of Pump Heads | 2 |
| Control System | Microprocessor-based |
| Fixed-Arm Design | Yes |
| Built-in Bag Weight Logging | Yes |
| Distribution Function | Yes |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NF-333 |
| Price | Upon Request |
| Brand | Proxivision |
|---|---|
| Origin | Canada |
| Model | HR-25-X-Ray |
| Coupling | 1:1 Fiber-Optic Taper |
| Coupling Efficiency | up to 70% |
| Sensor Format | 2/3″ CCD, 752 × 582 pixels |
| Pixel Size | 11.6 µm × 11.2 µm |
| Output | CCIR analog or 8/12-bit digital |
| Frame Rate | 17–30 fps |
| Field of View | 20 mm × 15 mm (configurable) |
| Scintillator | P43 phosphor (25 mg/cm², 55 µm thick) |
| X-ray Energy Range | 20–100 keV |
| Input Window | 0.5 mm Al foil (customizable) |
| Spatial Resolution | ≤50 µm / 10 lp/mm |
| Dimensions | Ø55 mm × 68 mm |
| Compliance | RoHS, CE-marked for industrial & NDT use |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | CMVP 50 |
| Vibration Velocity (RMS) | 0.1–55 mm/s (10 Hz–1 kHz) |
| Acceleration Envelope (gE) | 0.01–45 gE (10 kHz–30 kHz) |
| Weight | 77 g (incl. battery) |
| Compliance | ISO 2372 / ISO 10816 (velocity), SKF gE Diagnostic Standard (bearing health) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Smart SpectroTM |
| Pricing | Available Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | STR4/1 |
| Pricing | Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | STR4/2 |
| Pricing | Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | STR4/3 |
| Pricing | Available Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | STR4/4 |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model Numbers | CCD296, CCD525, CCD5061, CCD8091, CCD10121 |
| Pricing | Available upon Request |
| Origin | USA |
|---|---|
| Supplier Type | Authorized Distributor |
| Import Status | Imported |
| Model | CCD 447 / CCD 486 |
| Pricing | Upon Technical Evaluation and Configuration |
| Brand | WTW |
|---|---|
| Origin | Germany |
| Model | pHotoFlex |
| Optical Wavelengths | 436, 517, 557, 594, 610, 690 nm (±2 nm) |
| Photometric Range | Absorbance –0.200 to +2.000 |
| Repeatability | ±0.005 ABS |
| Resolution | 0.001 ABS |
| Measurement Time | 2 s |
| pH Range | –2.00 to +16.00 pH (±0.01 pH) |
| mV Range | –1000 to +1000 mV (±1 mV) |
| Temperature | –5.0 to +100.0 °C (±0.3 °C) |
| Turbidity Mode (pHotoFlex Turb) | IR LED @ 860 nm per DIN EN ISO 7027 |
| Data Storage | 1000 measurement records |
| Interface | RS-232 (AK540/B cable for PC |
| Dimensions | 236 × 86 × 117 mm |
| Weight | 0.6 kg |
| Ingress Protection | IP67 |
| Operating Temp. | 0–50 °C |
| Storage Temp. | –25 to +65 °C |
| Power | 4 × AA 1.5 V alkaline (≈5000 measurements) |
| Optional Accessories | LabStation portable lab platform (251301), LSdata software, SenTix 41 pH electrode, 28 mm and 16 mm cuvettes |