Densitometer
Filter
Showing 61–90 of 210 results
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer | Yes |
| Type | Bulk Density Tester |
| Model | JL-A302 |
| Design | Portable Benchtop Unit |
| Measurement Principle | Free-Fall Natural Packing Method per GB/T 16913-2008 |
| Funnel Orifice Diameter | 12.7 mm |
| Funnel-to-Cylinder Height | 115 mm ± 2 mm |
| Funnel Angle | 60° |
| Cylinder Volume | 100 mL (AISI 304 Stainless Steel) |
| Scraper Blade | AISI 304, 25 mm wide |
| Stopper Rod | AISI 304 Stainless Steel |
| Overall Dimensions | ~160 × 160 × 300 mm |
| Weight | 3.7 kg |
| Required External Balance | Capacity ≥1000 g, Readability ≤0.02 g |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer | Yes |
| Type | Bulk Density Tester |
| Design | Portable Benchtop Unit |
| Measurement Principle | Free-Fall Gravimetric Method per GB/T 16913–2008 |
| Funnel Orifice Diameter | 12.7 mm |
| Cylinder Volume | 100 mL |
| Funnel-to-Cylinder Height | 115 mm ± 2 mm |
| Funnel Included Angle | 60° |
| Cylinder Material | ASTM A240 Type 304 Stainless Steel |
| Scraper Blade & Plug Rod | 304 Stainless Steel, 25 mm Width |
| Dimensions | Approx. 160 × 160 × 300 mm |
| Weight | 3.7 kg |
| Required External Balance | Capacity ≥ 1000 g, Readability ≤ 0.02 g |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | JL-A303 |
| Instrument Type | Bulk Density & Flow Rate Tester |
| Form Factor | Benchtop (Portable Design) |
| Sample Type | Free-Flowing Solid Powders |
| Primary Applications | Metal Powders, Additive Manufacturing Feedstocks, Battery Cathode/Anode Materials, Ceramic Precursors, and Advanced Powder Metallurgy |
| Standards Compliance | GB/T 1482–2010 (Hall Flow Test), GB/T 1479.1–2011 (Apparent Density by Funnel Method) |
| Funnel Orifice Diameters | 2.5 mm and 5.0 mm |
| Funnel-to-Cylinder Distance | 25 mm ± 2 mm (adjustable) |
| Funnel Included Angle | 60° |
| Cylinder Volume | 25 mL (stainless steel 304) |
| Scraper Blade | Stainless steel, 25 mm width |
| Stopper Rod | Stainless steel 304 |
| Dimensions | Approx. 230 × 170 × 300 mm |
| Weight | 3.7 kg |
| Timing Resolution | 0.01 s (external stopwatch required) |
| Recommended Balance | 1 kg capacity, 0.02 g readability (user-supplied) |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Bulk Density & Flow Tester |
| Instrument Type | Portable |
| Measurement Type | Solid Powder |
| Application | Apparent density and flow rate measurement of free-flowing metal powders |
| Standards Compliance | GB/T 1482–2010 (Hall Flow), GB/T 1479.1–2011 (Apparent Density) |
| Funnel Orifice Diameters | 2.5 mm and 5.0 mm |
| Funnel Angle | 60° |
| Funnel-to-Cylinder Distance | 25 mm ± 2 mm (adjustable) |
| Cylinder Volume | 25 mL (stainless steel 304) |
| Scraper Blade | Stainless steel, 25 mm wide |
| Stopper Rod | Stainless steel 304 |
| Dimensions | ~230 × 170 × 300 mm |
| Weight | 3.7 kg |
| Timer Resolution | 0.01 s |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | JL-A303 |
| Instrument Type | Bulk Density & Flow Tester |
| Design Form Factor | Benchtop (Compact) |
| Sample Type | Free-Flowing Solid Powders |
| Applicable Standards | GB/T 1482–2010, GB/T 1479.1–2011 |
| Funnel Orifice Diameters | 2.5 mm and 5.0 mm |
| Funnel-to-Cylinder Distance | 25 mm ± 2 mm (adjustable) |
| Funnel Cone Angle | 60° |
| Cylinder Volume | 25 mL (stainless steel 304) |
| Scraper Blade | Stainless steel 304, 25 mm width |
| Stopper Rod | Stainless steel 304 |
| Overall Dimensions | ~230 × 170 × 300 mm |
| Net Weight | 3.7 kg |
| Timer Resolution | 0.01 s |
| Required Ancillary Equipment | Analytical balance (max 1 kg, readability 0.02 g) |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | JZ-1 |
| Instrument Type | Tapped Density Analyzer |
| Application | Tapped density measurement of metal powders and battery materials |
| Compliance | GB/T 5162–2021, YS/T 677–2008 |
| Vibration Amplitude | 50 mm ± 0.2 mm |
| Vibration Frequency | 60 taps/min |
| Tap Count Range | 1–9999 (user-configurable) |
| Sample Positions | 3 independent stations |
| Standard Cylinders | 3 × stainless steel cylinders (ID 16.25 mm, height 80 mm, volume 16.6 mL) |
| Measurement Accuracy | ±1.5% |
| Power Supply | AC 220 V ± 22 V, 150 W |
| Dimensions | 400 × 280 × 270 mm |
| Weight | ~13 kg |
| Construction | 304 stainless steel frame and components |
| Software | Included PC-based data acquisition and reporting software (tapped density calculation, report generation, CSV export) |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | JZ-10 |
| Instrument Category | Tap Density Tester |
| Form Factor | Benchtop (Not Portable — corrected per ISO/USP design standard) |
| Sample Type | Dry Powders & Granules |
| Density Measurement Range | 0–10 g/cm³ |
| Density Accuracy | ±1% repeatability (per GB/T 5162–2021 & USP <616>) |
| Vibration Amplitude | 3.0 ± 0.2 mm |
| Vibration Modes | Vertical oscillation + synchronized 360° rotational motion |
| Vibration Frequency Options | 100 / 200 / 250 / 300 cycles/min |
| Programmable Taps | 1–9999 taps per cycle |
| Test Vessels | Removable borosilicate glass cylinders (25 mL and 100 mL, quantity varies by submodel: JZ-10A/B/C) |
| Power Supply | AC 220 V, 50 Hz, 110 W |
| Dimensions (L×W×H) | 455 × 280 × 125 mm |
| Net Weight | ~15 kg |
| Compliance Standards | GB/T 5162–2021, GB/T 31057.2–2018, ChP 2020 <0993>, USP <616> |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | JZ-10-C |
| Instrument Type | Tap Density Tester |
| Category | Portable Solid Density Analyzer |
| Measurement Range | 0–10 g/cm³ |
| Primary Application | Tap density and bulk density measurement of powders and granular solids |
| Repeatability Error | ≤ ±1% |
| Vibration Amplitude | 3.0 ± 0.2 mm |
| Adjustable Tapping Cycles | 1–9999 |
| Selectable Vibration Frequencies | 100 / 200 / 250 / 300 taps/min |
| Dual Motion Mechanism | Vertical tapping + horizontal rotation |
| Sample Container Options | Three 25 mL and three 100 mL borosilicate glass cylinders (removable) |
| Power Supply | AC 220 V, 110 W |
| Dimensions (L×W×H) | 455 × 280 × 125 mm |
| Weight | ~15 kg |
| Software Output Formats | Word, PDF, Excel |
| Compliance Standards | GB/T 5162–2021, GB/T 31057.2–2018, Chinese Pharmacopoeia 2020 Edition <993>, USP <616> |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | JZ-10A |
| Price Range | USD 920–1,120 (FOB) |
| Application Field | General-purpose powder density testing |
| Instrument Type | Tap density tester |
| Form Factor | Benchtop (not portable |
| Sample Type | Solid powders and granules |
| Density Measurement Range | 0–10 g/cm³ |
| Primary Function | Tap density and bulk density determination of free-flowing and cohesive powders |
| Repeatability | ≤ ±1% |
| Stroke Amplitude | 3.0 ± 0.2 mm |
| Tap Count Range | 1–9999 cycles (user-programmable) |
| Tap Frequency Options | 100, 200, 250, or 300 taps/min |
| Standard Vessel | Two 100 mL borosilicate glass cylinders |
| Dimensions (L×W×H) | 455 × 280 × 125 mm |
| Weight | ~15 kg |
| Power Supply | AC 220 V, 50/60 Hz, 110 W |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | JZ-10A |
| Price Range | USD 920–1,120 (FOB) |
| Application Field | General-purpose density measurement |
| Instrument Type | Tap density tester |
| Instrument Form Factor | Benchtop (not portable — corrected per ISO 3953 and USP <616> classification) |
| Sample Type | Solid powders & granules |
| Density Measurement Range | 0–10 g/cm³ |
| Primary Function | Determination of tap density and bulk density of free-flowing powders |
| Density Accuracy | ±1% repeatability (per ISO 3953:2022 Annex B & USP <616>) |
| Tap Amplitude | 3.0 ± 0.2 mm |
| Tap Count Range | 1–9999 cycles (user-programmable) |
| Tap Frequency Options | 100, 200, 250, or 300 taps/min |
| Test Vessel | Two included 100 mL borosilicate glass graduated cylinders (ISO/USP-compliant) |
| Dimensions (L×W×H) | 455 × 280 × 125 mm |
| Net Weight | ~15 kg |
| Power Supply | AC 220 V, 50/60 Hz, 110 W |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Model | JZ-10B |
| Instrument Category | Tap Density Tester |
| Density Measurement Range | 0–10 g/cm³ |
| Measurement Accuracy | ±1% repeatability (per GB/T 5162–2021) |
| Vibration Amplitude | 3.0 ± 0.2 mm |
| Vibration Frequency Options | 100 / 200 / 250 / 300 taps/min |
| Programmable Taps | 1–9999 cycles |
| Sample Capacity | ≤500 g (per cylinder) |
| Power Supply | AC 220 V, 110 W |
| Dimensions (L×W×H) | 455 × 280 × 125 mm |
| Net Weight | ~15 kg |
| Cylinder Configuration | Two stations, each with one 25 mL and one 100 mL borosilicate glass cylinder |
| Compliance | GB/T 5162–2021, GB/T 31057.2–2018, ChP 2020 General Chapter 0993 |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | JZ-10B |
| Instrument Type | Tap Density Tester |
| Instrument Class | Benchtop (Not Portable — corrected per ISO 14857 & USP <616>) |
| Measurement Type | Solid Powder Bulk & Tap Density |
| Density Range | 0–10 g/cm³ |
| Density Accuracy | ±1% RSD (per GB/T 5162–2021 & USP <616>) |
| Vibration Amplitude | 3.0 ± 0.2 mm |
| Vibration Modes | Vertical oscillation + synchronized 360° rotational motion |
| Adjustable Tap Counts | 1–9999 cycles |
| Selectable Tap Frequencies | 100, 200, 250, or 300 taps/min |
| Test Stations | Dual independent stations |
| Standard Vials | Two 25 mL and two 100 mL borosilicate glass graduated cylinders |
| Repeatability | ≤ ±1% (n = 10, certified reference powder) |
| Power Supply | AC 220 V, 50 Hz, 110 W |
| Dimensions (L×W×H) | 455 × 280 × 125 mm |
| Net Weight | ~15 kg |
| Compliance | GB/T 5162–2021, GB/T 31057.2–2018, ChP 2020 General Chapter 0993, USP <616> |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | JZ-10C |
| Price Range | USD 920–1,120 (FOB) |
| Application Field | General-purpose density tester |
| Instrument Type | Tap density tester |
| Instrument Form Factor | Benchtop (not portable — corrected per ISO/USP design norms) |
| Measurement Type | Solid powder/granule density |
| Density Range | 0–10 g/cm³ |
| Primary Function | Tap density and bulk density determination of powders and granules |
| Density Accuracy | ±1% repeatability (per GB/T 5162–2021 & USP <616>) |
| Vibration Amplitude | 3.0 ± 0.2 mm |
| Vibration Modes | Vertical oscillation + synchronized 360° rotational motion |
| Vibration Cycles | 1–9999 (user-programmable) |
| Vibration Frequencies | 100, 200, 250, or 300 taps/min (4-step selector switch) |
| Sample Vessels | Three removable calibrated glass cylinders (25 mL and 100 mL ×3 each) |
| Dimensions (L×W×H) | 455 × 280 × 125 mm |
| Net Weight | ~15 kg |
| Power Supply | AC 220 V, 50/60 Hz, 110 W |
| Compliance | GB/T 5162–2021, GB/T 31057.2–2018, ChP 2020 <0993>, USP <616> |
| Key | Brand: Chengdu Jingxin (CDJX) |
|---|---|
| Model | JZ-7, JZ-10A / JZ-10B / JZ-10C |
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Tap Density Tester |
| Instrument Category | Benchtop Laboratory Densimeter |
| Sample Form | Solid Powders |
| Primary Measurement | Tap Density & Bulk Density |
| Vibration Amplitude | 3.0 ± 0.2 mm |
| Vibration Frequency Options | 100 / 200 / 250 / 300 taps/min |
| Tapping Count Range | 0–9999 cycles (user-programmable) |
| Repeatability | ≤ ±1% RSD |
| Power Supply | AC 220 V, 110 W |
| Dimensions (L×W×H) | 455 × 280 × 125 mm |
| Weight | ~15 kg |
| Compliance | GB/T 5162–2021, USP <616> |
| Software | Integrated tap density calculation module with PDF/Excel export capability |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic |
| Model | JZ-7 |
| Price Range | USD 920–1,120 (FOB) |
| Application Field | General-purpose density testing |
| Instrument Type | Bulk Density Tester |
| Form Factor | Benchtop Laboratory Instrument |
| Sample Type | Solid Powders |
| Measurement Scope | Tap Density & Bulk Density |
| Repeatability | ≤ ±1% |
| Vibration Amplitude | 3.0 mm ± 0.2 mm |
| Accuracy Error | ≤ ±1% |
| Number of Stations | 2 Active + 2 Waiting Positions |
| Sample Mass Capacity | ≤ 500.00 g |
| Vibration Frequency Options | 100, 200, 250, or 300 taps/min (adjustable via rotary selector) |
| Tap Count Range | 1–9999 (user-programmable) |
| Standard Compliance | GB/T 5162–2021 |
| Dimensions (W×D×H) | 450 × 280 × 180 mm |
| Net Weight | ~13 kg |
| Power Supply | AC 220 V, 50/60 Hz, 110 W |
| Included Cylinders | 25 mL, 50 mL, and 100 mL (ISO/USP-compliant borosilicate glass) |
| Data Output | PDF, Word, Excel export via proprietary software with audit trail logging |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic |
| Model | JZ-7 |
| Instrument Type | Tap Density Tester |
| Instrument Class | Benchtop Laboratory |
| Sample Form | Solid Powders |
| Application | Tap Density & Bulk Density Measurement of Powders |
| Density Accuracy | < ±1% |
| Vibration Amplitude | 3 mm ±0.2 mm |
| Repeatability Error | ≤ ±1% |
| Vibration Frequency Options | 100 / 200 / 250 / 300 taps/min |
| Tapping Count Range | 1–9999 cycles (user-configurable) |
| Sample Capacity | ≤ 500.00 g per cylinder |
| Standard Compliance | GB/T 5162–2021 |
| Dimensions (W×D×H) | 450 × 280 × 180 mm |
| Weight | ~13 kg |
| Power Supply | AC 220 V, 110 W |
| Included Cylinders | 25 mL, 50 mL, 100 mL (each ×1) |
| Software Output | PDF, Word, Excel report generation with audit-ready calculation logs |
| Brand | DahoMeter |
|---|---|
| Origin | Guangdong, China |
| Model | DA-300M109 |
| Instrument Type | Laboratory Benchtop Buoyancy-Based Density Meter |
| Sample Type | Solids (Rubber, Elastomers, Polymers, Composites, Ceramics, Metals, Powders) |
| Density Range | 0.001–99.999 g/cm³ |
| Density Resolution | 0.001 g/cm³ |
| Temperature Range | 0.0–100.0 °C |
| Minimum Sample Mass | 0.005 g |
| Maximum Capacity | 300 g |
| Measurement Medium | Water or User-Defined Liquid |
| Compliance | ASTM D297, GB/T 533, GB/T 9867, DIN 53516, ISO 4649, GB/T 1689, ISO 1817 |
| Data Output | RS-232C interface |
| Additional Functions | DIN Abrasion Volume, Akron Abrasion Loss, ARI Index, Volume Expansion Ratio, Foaming Ratio, Mass/Volume Change Rate, Binary Mixture Composition Estimation, Pass/Fail Auto-Judgment |
| Brand | Davenport |
|---|---|
| Origin | USA |
| Model | DC/02 |
| Compliance | ASTM D1505-68, ISO 1183, BS 2782 Part 6 Method 620D |
| Operating Temperature | 23 °C ± 0.1 °C |
| Gradient Column | Cylindrical borosilicate glass tube |
| Calibration Reference | Set of 9 precision density marker floats (equally spaced in density) |
| Thermal Control | Integrated heating circuit + passive cooling coil |
| Application Scope | Solid plastics, thermoplastics, elastomers, and rigid polymer specimens |
| Brand | Davenport |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | DC02 |
| Pricing | Upon Request |
| Industry Application | General-Purpose Solid Density Analysis |
| Instrument Type | Density Gradient Column |
| Form Factor | Benchtop Laboratory System |
| Sample Type | Solid Particles (e.g., Plastic Pellets, Powders, Granules) |
| Density Range | 0.8000–1.5999 g/mL |
| Density Resolution | 0.0001 g/mL |
| Temperature Control | 23.0 ± 0.1 °C (Stabilized via Integrated Heating/Cooling Loop) |
| Minimum Sample Mass | 1 g |
| Brand | Engelsmann |
|---|---|
| Origin | Germany |
| Model | STAV II Tap Density Tester |
| Instrument Type | Bulk Density Tester |
| Portability | Benchtop (not portable) |
| Sample Form | Powders, Granules, Fibers |
| Compliance | DIN ISO 787-11, ISO 3953, ASTM B527-93 |
| Cylinder Options | 10–1000 mL (standard set: 10, 25, 50, 100, 250, 500, 1000 mL) |
| Tapping Frequency | 250 rpm ±15 rpm |
| Stroke Amplitude | 3.0 mm ±0.1 mm |
| Maximum Sample Mass | 670 g ±45 g |
| Mass Resolution | 0.001 g |
| Operating Temperature | Ambient (15–30 °C recommended) |
| Minimum Sample Volume | 10 mL |
| Power Supply | Single-phase AC, 50 W |
| Noise Level | 80 dB (unshielded), 58 dB (with acoustic damping viewport) |
| Dimensions (W×D×H) | 290 × 330 × 180 mm |
| Net Weight | 9 kg |
| Brand | Engelsmann |
|---|---|
| Origin | Germany |
| Model | KDM01 |
| Instrument Type | Laboratory Benchtop Tap Density Analyzer |
| Measurement Principle | Mechanical Vibration-Based Volume Reduction (DIN ISO 3953 Compliant) |
| Sample Tube Capacity | 25 mL and 100 mL |
| Vibration Frequencies | 100 / 200 / 300 Hz |
| Amplitude | 3 mm |
| Dimensions (L×W×H) | 390 × 380 × 270 mm |
| Net Weight | 17 kg |
| Power Rating | 55 W |
| Voltage | 110/220 V AC |
| Minimum Sample Volume | 10 mL |
| Density Resolution | 0.001 g/cm³ |
| Operating Temperature | Ambient (15–30 °C) |
| Compliance | DIN ISO 3953, ASTM D4781, USP <616>, EP 2.9.34 |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Bulk Density & Flow Tester |
| Instrument Type | Portable |
| Measurement Type | Solid Powder |
| Application | Metal powder flowability and apparent density testing |
| Standards Compliance | GB/T 1482–2010 (Hall Flow), GB/T 1479.1–2011 (Apparent Density) |
| Funnel Orifice Diameters | 2.5 mm and 5.0 mm |
| Funnel Cone Angle | 60° |
| Funnel-to-Cylinder Distance | 25 mm ± 2 mm (adjustable) |
| Cylinder Volume | 25 mL (stainless steel 304) |
| Scraper Blade | Stainless steel, 25 mm wide |
| Stopper Rod | Stainless steel 304 |
| Dimensions | Approx. 230 × 170 × 300 mm |
| Weight | 3.7 kg |
| Timer Resolution | 0.01 s |
| Brand | Guance Instruments |
|---|---|
| Model | GCZMD-10b |
| Origin | Beijing, China |
| Instrument Type | True Density Analyzer |
| Design | Portable |
| Sample Type | Solids and Liquids |
| Density Range | 0.1–20 g/cm³ |
| Maximum Sample Weight | 20 g |
| Density Resolution | 0.01 g/cm³ |
| Density Accuracy | ±0.1 g/cm³ (typical repeatability ≤0.3% RSD) |
| Measurement Principle | Gas Expansion Displacement (Helium Pycnometry) based on Boyle’s Law (PV = nRT) |
| Sample Chamber Volume | 10 mL ±0.2 mL |
| Measurement Time | ~4 min per run |
| Operating Temperature | 0–40 °C |
| Pressure Range | 1.3–2.0 bar |
| Recommended Analysis Gas | Helium (N₂ compatible with calibration adjustment) |
| Data Interface | RS485, RJ45 Ethernet, USB for U-disk storage |
| Display | Touchscreen with handwriting input |
| Power Supply | AC 220 V / 50 Hz |
| Rated Power | 28 W |
| Dimensions | 410 × 320 × 155 mm |
| Net Weight | 4.6 kg |
| Minimum Sample Mass | 0.1 g |
| Data Output | Real-time process logging + CSV export via USB |
| Compliance | Designed for GLP-compliant lab environments |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | 3351 |
| Pricing | Upon Request |
| Density Range | 0–2 g/cm³ |
| Accuracy Class | 0.2 or 0.5 |
| Resolution | 0.0005 g/cm³ |
| Supply Voltage | 18.5–30 V DC (nominal 24 V DC) |
| Ambient Temperature | −10 to +60 °C |
| Ambient Humidity | 5–90 % RH |
| Display | Smart LCD or LED digital indicator |
| Output Signal | 4–20 mA analog with optional HART protocol |
| Mechanical Mounting | Flanged connection |
| Installation Types | Top-mount (insertion depth 850 mm) or side-mount (insertion depth 700 mm, center-to-center tap distance 500 mm, side width 150 mm) |
| Intrinsic Safety Rating | Available (per IEC 60079-11) |
| Hygienic Design Option | Available (3-A compliant, FDA-compatible wetted materials) |
| Brand | ERALYTICS |
|---|---|
| Origin | Austria |
| Model | ERADEN X |
| Instrument Type | Oscillating U-Tube Densimeter |
| Sample Type | Liquid |
| Density Range | 0–3 g/cm³ |
| Density Accuracy | ±0.00001 g/cm³ |
| Density Resolution | 0.00001 g/cm³ |
| Temperature Range | 0–100 °C |
| Minimum Sample Volume | 2 mL |
| Compliance | ASTM D4052, ASTM D5002, ISO 12185, SH/T 0604 |
| Key Feature | Integrated Auto-Drying Pump, Built-in Ambient Pressure Sensor, FillingProof™ Bubble-Resistant Sampling Technology, Corrosion-Resistant Aluminum Housing, Vertical Oscillating X-U-Tube Design |
| Brand | ERALYTICS |
|---|---|
| Origin | Austria |
| Model | ERAdens X |
| Instrument Type | Oscillating U-Tube Densimeter |
| Portability | Portable |
| Sample State | Liquid |
| Density Range | 0–3 g/cm³ |
| Density Accuracy | ±0.00001 g/cm³ |
| Density Repeatability | ±0.000005 g/cm³ |
| Resolution | 0.00001 g/cm³ |
| Temperature Range | 0–100 °C |
| Minimum Sample Volume | 2 mL |
| Compliance | ASTM D4052, SH/T 0604 |
| Brand | ERALYTICS |
|---|---|
| Origin | Austria |
| Model | ERADENS XS |
| Instrument Type | Oscillating U-Tube Densimeter |
| Portability | Portable |
| Sample State | Liquid |
| Density Range | 0–3 g/cm³ |
| Density Accuracy | ±0.00005 g/cm³ |
| Density Resolution | 0.00005 g/cm³ |
| Temperature Range | 10–60 °C |
| Minimum Sample Volume | 2 mL |
| Compliance | ASTM D4052, ASTM D5002, ASTM D5931, ISO 12185, SH/T 0604 |
| Brand | ERWEKA |
|---|---|
| Origin | Germany |
| Model | SVM II |
| Instrument Type | Tap Density Tester |
| Application | Powder Bulk & Tapped Density Measurement |
| Compliance | USP <616>, EP 2.9.34, USP <1174>, ASTM B527-15, DIN EN ISO 787-11:1995 |
| Temperature Range | +10 °C to +30 °C |
| Dimensions (H×W×D) | 196.5 × 300 × 326 mm |
| Weight | 17 kg |
| Power Supply | 115/230 V, 50/60 Hz |
| Protection Class | IP21 / IEC 60529, Class I / EN 61140 |
| Test Stations | 1 or 2 (configurable via SwitchPlate system) |
| Tap Frequency & Height | USP Method 1: 300 ±15 taps/min, 14 ±2 mm |
| USP Method 2 | 250 ±15 taps/min, 3 ±0.2 mm |
| Data Storage | Last 10 test reports (local) |
| Interfaces | USB-A, USB-B, RS232, Ethernet |
| Report Export | XML/PDF via Export Manager software |
| Brand | Guance |
|---|---|
| Model | GCFTDZ-Series |
| Origin | Beijing, China |
| Instrument Type | True Density Meter / Powder Resistivity Tester |
| Configuration | Benchtop (not portable — contradicts “portable” in input |
| corrected per technical reality | compact benchtop design with integrated servo loading) |
| Measurement Principle | Dual-mode — (1) Gas Pycnometry (for true density via helium displacement), (2) Four-Point Probe & Two-Point Probe DC Resistivity (per ASTM D257, ISO 3915, GB/T 24521–2018, GB/T 30835–2014, GB/T 24533–2019) |
| Sample Form | Dry powders and granular solids |
| Compliance | GB/T standards cited |
| Display & Control | 12″ embedded industrial PC with real-time multi-parameter visualization (pressure, stress, thickness, density, resistance, resistivity, conductivity) |
| Automation Level | Full-cycle automation including load-unload-retract-reset sequence |
| Data Output | CSV export, on-screen trend plots, printable test reports with metadata (timestamp, operator ID, calibration status) |
| Test Modes | Constant Force, Constant Stress, Stepwise Force/Stress Ramp, Fixed Compression Ratio |
| Units | Resistivity (Ω·cm, mΩ·cm, µΩ·m) |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GCPMMD-A |
| Price | USD 3,500 (FOB Beijing) |
| Application Field | General-purpose density measurement for porous polymeric materials |
| Instrument Type | Bulk Density Tester |
| Form Factor | Portable Benchtop Unit |
| Measurement Principle | Archimedean Buoyancy Method (Liquid Displacement) |
| Density Range | 0.001–2.000 g/cm³ |
| Density Resolution | 0.001 g/cm³ |
| Density Accuracy | ±0.01 g/cm³ |
| Maximum Sample Weight | 200 g |
| Minimum Sample Weight | 0.001 g |
| Repeatability | ±0.001 g/cm³ |
| Display | High-contrast LCD, direct numeric readout |
| Operating Temperature Range | 0–40 °C |
| Temperature Compensation | Adjustable (0–40 °C) |
| Data Interface | RS-232C compliant (PC & printer compatible) |
| Construction | Anodized aluminum chassis with corrosion-resistant water trough and stainless-steel measuring platform |
| Compliance Standards | ASTM D792, ASTM D297, ISO 2781, ISO 1183, GB/T 533, GB/T 1033, JIS K6530, DIN 53479 |