Densitometer
Filter
Showing 151–180 of 210 results
| Brand | KRUESS |
|---|---|
| Origin | Germany |
| Model | DS7800 |
| Instrument Type | Laboratory Benchtop Oscillating U-Tube Densimeter |
| Sample Type | Liquid |
| Density Range | 0.0000–1.9999 g/cm³ |
| Density Accuracy | ±0.0001 g/cm³ |
| Density Resolution | 0.0001 g/cm³ |
| Repeatability | ±0.0001 g/cm³ |
| Temperature Control Range | 10–40 °C |
| Temperature Stability | ±0.02 °C |
| Minimum Sample Volume | 0.9 mL |
| Measurement Time | ~5 min |
| Calibration Standards | Dry air and distilled water |
| Compliance | ASTM D4052, ASTM D5002, NIST-traceable, GLP/GMP-ready |
| Data Storage | SQL database (999 results) |
| Interface Options | Ethernet, USB 2.0, RS-232 |
| Display | 5.7″ TFT color LCD (640×480 VGA) |
| Power Supply | 90–264 V AC, 50/60 Hz |
| User Management | Three-level password protection |
| Language Support | 6 languages |
| LIMS Compatibility | Yes |
| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JK-SZ2000 |
| Instrument Type | Scott Volumeter |
| Instrument Category | Benchtop Laboratory Densitometer |
| Sample Type | Free-Flowing Metallic Powders |
| Standard Compliance | GB/T 5060–1985 (equivalent to ISO 3923-2) |
| Measurement Principle | Gravimetric Volumetric Method with Controlled Flow Damping |
| Configuration | Integrated Funnel Assembly, Quadruple Baffle System, Cylindrical Receiving Cup (25.0 mL nominal volume), Stainless Steel Straightedge & Tapping Platform |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Oscillating U-Tube Densimeter |
| Portability | Portable |
| Sample Phase | Liquid |
| Application Focus | Petroleum Products Density Measurement |
| Density Range | 0.6–2.2 g/cm³ |
| Density Resolution | 0.0001 g/cm³ |
| Temperature Control Range | 15–40 °C (Peltier-regulated) |
| Temperature Accuracy | ±0.03 °C |
| Minimum Sample Volume | 1.5 mL |
| Compliance | ASTM D4052, ISO 12185, IP 365, GB/T 1884 |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Oscillating U-Tube Densimeter |
| Portability | Portable |
| Sample Phase | Liquid |
| Application Focus | Petroleum Products Density Measurement |
| Density Range | 0.6–2.2 g/cm³ |
| Density Resolution | 0.0001 g/cm³ |
| Temperature Control Range | 15–40 °C (Peltier-regulated) |
| Temperature Accuracy | ±0.03 °C |
| Minimum Sample Volume | 1.5 mL |
| Compliance | ASTM D4052, ISO 12185, IP 365, GB/T 1884 |
| Brand | LEMIS / LEMIS Baltic |
|---|---|
| Model | DM-230.2A |
| Density Range | 0.6500–1.1000 g/cm³ |
| Density Accuracy | ±0.0005 g/cm³ (typical, per ISO 12185) |
| Operating Temperature Range | −40 to +85 °C |
| Submersion Depth | Up to 30 m |
| Data Storage Capacity | 998 measurements |
| Wireless Interface | Integrated Bluetooth® 4.2 for PC and portable printer connectivity |
| Calibration Compliance | Traceable to NIST and PTB standards |
| Hazardous Area Certification | ATEX II 2G Ex ib IIB T4 Gb / IECEx Ex ib IIB T4 Gb |
| Regulatory Listing | Registered in the State Register of Measuring Instruments (Eurasian Economic Union) |
| Brand | MAYZUM |
|---|---|
| Model | MAYA203DIV2L |
| Type | Benchtop Solid Density Analyzer for Hydrogen Quantification in Aluminum Melts |
| Density Resolution | 0.0001 g/cm³ |
| Temperature Range | −30 °C to +60 °C |
| Display | Digital LCD |
| Origin | Guangdong, China |
| Manufacturer | MAYZUM (OEM/ODM Capable) |
| Compliance | GB/T 43139–2023, GB/T 5611–2017, ASTM E807 (adapted), ISO 11922 (principles) |
| Brand | MAYZUM |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | MAYB124G |
| Instrument Type | Laboratory Benchtop Buoyancy-Based Densimeter |
| Sample Type | Liquids Only |
| Density Range | 0.0001–3.0000 g/cm³ (equivalent to 0.1–100% concentration for common aqueous/organic solutions) |
| Maximum Sample Weight Capacity | 120 g |
| Density Resolution | 0.0001 g/cm³ |
| Display | Digital LCD |
| Compliance Standards | GB/T 13531, GB/T 5526, GB/T 5009, ASTM D1298, ASTM D4052, JIS K 0061, ISO 12185 |
| Measurement Principle | Archimedean buoyancy displacement method |
| Brand | Mayzum |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | MZ-Y300 |
| Instrument Category | Laboratory Benchtop Buoyancy-Based Densimeter |
| Sample Type | Solid Porous Materials |
| Density Range | 0.01–99.999 g/cm³ |
| Maximum Capacity | 300 g |
| Density Resolution | 0.001 g/cm³ |
| Display | Digital LCD |
| Application Scope | Universal Density Testing for Open- and Closed-Cell Porous Polymers |
| Compliance Context | Designed to support ASTM D3574, ISO 845, ISO 1183-1, and GB/T 6343 test protocols |
| Origin | Jilin, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | MD-J |
| Pricing | Available Upon Request |
| Measurement Range | 0.8–3.5 g/cm³ |
| Sample Mass | 5–12 g |
| Accuracy | ±1% |
| Scale Graduation | 0.01 (0.8–2.0), 0.02 (2.0–2.5), 0.05 (2.5–3.5) g/cm³ |
| Sample Requirements | Bubble-free, smooth-surfaced, oil- and contaminant-free specimens |
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | MDZ-II |
| Pricing | Available Upon Request |
| Maximum Sample Volume | 40 cm³ |
| Accuracy | ±0.15% |
| Repeatability | ±0.05% |
| Density Resolution | 0.0001 g/cm³ |
| Carrier Gas | High-Purity Helium or Nitrogen |
| Operating Pressure | ~1.25 atm |
| Dimensions | 385 × 335 × 200 mm |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | Densito 30PX |
| Instrument Type | Portable Digital Density Meter |
| Measurement Principle | Oscillating U-tube (Digital Density Determination) |
| Density Range | 0 to 2 g/cm³ |
| Density Resolution | 0.0001 g/cm³ |
| Density Accuracy | ±0.001 g/cm³ |
| Temperature Range | 5–35 °C |
| Temperature Resolution | ±0.1 °C |
| Temperature Compensation | Yes, user-selectable coefficient |
| Sample Types | Liquids and low-viscosity solutions |
| Compliance | ASTM D7777, ISO 12185, USP <841>, GLP/GMP-ready data logging |
| Data Storage | Up to 1100 measurements with timestamp, sample ID, temperature correction factor, instrument ID |
| Interface | Infrared (IR), RS232 via optional IR/RS232 converter (P/N 51325006) |
| Display | Backlit dot-matrix LCD with icon-based navigation |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | Densito / Densito Pro |
| Density Measurement Range | 0–3 g/cm³ |
| Density Accuracy | ±0.001 g/cm³ |
| Temperature Range | 0–50.0 °C |
| Minimum Sample Volume | 2 mL |
| Instrument Type | Portable Digital Density Meter (Oscillating U-tube Principle) |
| Application Scope | Liquid Density Measurement for QC/QA in Lab, Field, and Production Environments |
| Compliance | Designed to support GLP/GMP workflows with audit-trail-capable data management |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | Densito |
| Instrument Type | Portable Digital Density Meter |
| Sample Type | Solids and Liquids |
| Density Range | 0.000–3.000 g/cm³ |
| Density Accuracy | ±0.001 g/cm³ |
| Density Repeatability | ±0.0005 g/cm³ |
| Operating Temperature Range | −10 °C to +50 °C |
| Measurement Units | g/cm³, g/mL, kg/m³, °Brix, API, °Baumé, % ethanol (v/v), % H₂SO₄, US/UK Proof, Plato, specific gravity, user-defined concentration scales |
| Data Storage Capacity | 1100 measurements with sample ID, temperature correction factor, instrument ID, timestamp, and unit |
| Display | Full-color backlit LCD |
| Language Support | English, Chinese, German, Spanish, French, Italian, Portuguese, Indonesian, Korean, Polish, Russian, Thai, Turkish |
| Connectivity | USB, optional printer output, compatible with EasyDirect PC software |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | D4 / D5 / D6 |
| Instrument Type | Benchtop Laboratory Density Meter |
| Sample Type | Solid and Liquid |
| Temperature Range | 0–95 °C (32–203 °F) |
| Repeatability | ±0.00005 g/cm³ |
| Resolution | 0.0001 g/cm³ |
| Density Range | 0.000–3.000 g/cm³ |
| Accuracy | ±0.0001 / ±0.00005 / ±0.000005 g/cm³ (model-dependent) |
| Temperature Accuracy | ±0.03 / ±0.02 / ±0.01 °C (model-dependent) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | D4/D5/D6 |
| Instrument Type | Laboratory Benchtop Digital Density Meter |
| Measurement Principle | Oscillating U-tube (ASTM D4052, ISO 12185, USP <841>) |
| Sample Type | Liquids and Low-Viscosity Solutions |
| Density Range | 0 to 3 g/cm³ |
| Density Resolution | 0.0001 g/cm³ |
| Temperature Control Range | 0 °C to 95 °C |
| Minimum Sample Volume | 1.5 mL |
| Compliance | 21 CFR Part 11 Ready (with LabX software), GLP/GMP Audit Trail Capable |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | Densito / DensitoPro |
| Density Range | 0.000–3.000 g/cm³ |
| Accuracy | ±0.001 g/cm³ |
| Repeatability | ±0.0005 g/cm³ |
| Sample Temperature Range | 0–50 °C |
| Ambient Temperature Range | Densito: −10–50 °C |
| DensitoPro | 0–50 °C |
| Data Storage Capacity | 1,100 results |
| Supported Units | Density, Specific Gravity, Brix, API Gravity, Baumé, Ethanol (% v/v), H₂SO₄ Concentration, US/UK Proof, Plato, User-Defined Concentrations |
| Display | Full-color backlit LCD |
| Languages | English, Chinese, German, Spanish, French, Italian, Portuguese, Indonesian, Korean, Polish, Russian, Thai, Turkish |
| Connectivity | USB, Bluetooth (DensitoPro), RFID/Barcode Reader (DensitoPro only) |
| Software Integration | EasyDirect PC Software |
| Compliance | Designed for GLP/GMP environments with audit-trail-ready data export |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | DM40 |
| Density Measurement Range | 0.0000–3.0000 g/cm³ |
| Density Repeatability (SD, n=10) | 0.00005 g/cm³ |
| Density Accuracy | 0.0001 g/cm³ (typical) |
| Temperature Control Range | 0–91 °C |
| Minimum Sample Volume | 1 mL |
| Instrument Type | Laboratory Benchtop Digital Density Meter |
| Measurement Principle | Oscillating U-tube (vibrating tube) densitometry |
| Compliance | ASTM D4052, ISO 12185, USP <841>, IP 270, DIN 51757 |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | D30/D40 |
| Instrument Type | Laboratory Benchtop Digital Density Meter |
| Measurement Principle | Oscillating U-tube (Digital Vibrating Tube) |
| Sample Type | Liquids |
| Density Range | 0 to 3 g/cm³ |
| Density Resolution | 0.00001 g/cm³ |
| Density Accuracy | ±0.00002 g/cm³ |
| Temperature Control Range | 0 to 91.0 °C |
| Temperature Stability | ±0.01 °C |
| Minimum Sample Volume | 1 mL |
| Compliance | ASTM D4052, ISO 12185, USP <841>, IP 160, DIN 51757 |
| Data Management | FDA 21 CFR Part 11 compliant software support (via EasyDirect™), GLP/GMP audit trail capable |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | Easy D30, Easy D40 |
| Instrument Type | Benchtop Digital Density Meter |
| Sample Type | Solid and Liquid |
| Density Range | 0–3 g/cm³ |
| Temperature Range | 15–25 °C (Easy D30), 15–50 °C (Easy D40) |
| Density Resolution | 0.001 g/cm³ (Easy D30), 0.0001 g/cm³ (Easy D40) |
| Density Accuracy | ±0.001 g/cm³ (Easy D30), ±0.0005 g/cm³ (Easy D40) |
| Temperature Accuracy | ±0.2 °C (Easy D30), ±0.1 °C (Easy D40) |
| Minimum Sample Volume | 1.2 mL |
| Measurement Units | Density, Specific Gravity, Alcohol % v/v, Brix, API Gravity, Acidity, Urea Concentration, Custom Concentration |
| Built-in Methods | 16 |
| Bubble Detection | BubbleCheck™ (Easy D40 only) |
| Viscosity Correction | Automatic (both models) |
| Cleaning Check | Yes (both models) |
| Dimensions (W × H × D) | 170 × 156 × 273 mm |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | SC1 / SC30 |
| Sample Capacity | 1 vial (20 mL, 9 mL, or 6 mL) |
| Maximum Sample Viscosity | ≤ 30,000 mPa·s |
| Sample Introduction Method | Positive-pressure pumping |
| Cleaning Protocol | Dual-solvent automated rinse and dry |
| Drying Method | Pneumatic-assisted air-drying |
| Temperature Control | Optional electric heating module (for sample pre-conditioning) |
| Sample Recovery | Optional automatic return to source vial |
| Compliance | Designed for integration with METTLER TOLEDO DE (density), RE (refractometry), and DR (combined density/refractometry) instruments |
| Brand | Malvern Panalytical |
|---|---|
| Origin | USA |
| Manufacturer | Micromeritics Instrument Corporation |
| Model | AccuPyc III 1350 |
| Instrument Type | True Density Analyzer |
| Form Factor | Benchtop Laboratory System |
| Sample Type | Solid Materials |
| Density Range | 0.1–100 cm³ (sample volume) |
| Density Accuracy | ±0.02% |
| Temperature Control Range | 4 °C to 60 °C, stability ±0.025 °C |
| Repeatability | ±0.01% |
| Minimum Sample Volume | 0.1 cm³ |
| Brand | Micromeritics |
|---|---|
| Origin | USA |
| Model | AccuPyc III 1350 |
| Instrument Type | True Density Analyzer |
| Configuration | Benchtop Laboratory System |
| Sample Form | Solid Powders, Granules, Monoliths |
| Measurement Principle | Gas Displacement (Helium/Nitrogen/Air) |
| Density Range | 0.1–100 cm³ (Sample Volume Capacity) |
| Accuracy | ±0.02% |
| Repeatability | ±0.01% |
| Temperature Control Range | 4 °C to 60 °C |
| Temperature Stability | ±0.025 °C |
| Minimum Sample Volume | 0.1 cm³ |
| Compliance | ASTM D5550, ISO 12154, USP <699>, GLP/GMP-ready audit trail support |
| Brand | Micromeritics |
|---|---|
| Origin | USA |
| Model | GeoPyc 1365 |
| Instrument Type | Benchtop Envelope Density Analyzer |
| Sample Form | Solids (powders, granules, irregular solids, tablets, foams) |
| Measurement Principle | Solid displacement using Dry Flo™ quasi-fluid medium |
| Envelope Volume Range | 0.3–25 cm³ (via interchangeable sample cups) |
| Density Accuracy | <0.15% deviation vs. ASTM D1895, D6342, D7481 |
| Operating Temperature | 15–35 °C |
| Minimum Sample Requirement | ≥25% of selected cup volume |
| Compliance | ASTM D1895 (Type A), D6342, D7481, ISO 697, USP <699>, FDA 21 CFR Part 11 (with optional audit trail module) |
| Optional T.A.P. Density Module | Programmable consolidation force (0.5–10 N), stepwise compression cycles, real-time force & displacement monitoring |
| Brand | Microtrac |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BELPYCNO L |
| Instrument Type | True Density Analyzer |
| Instrument Class | Benchtop Laboratory Analyzer |
| Sample Type | Solids, Powders, Pastes, Liquids |
| Measurement Principle | Gas Displacement Pycnometry (Helium-Based) |
| Pressure Range | Vacuum to 2.5 bar |
| Temperature Control Range | 14–40 °C (Peltier-Driven, Optional) |
| Temperature Stability | ±0.01 °C |
| Density Accuracy | ±0.01% |
| Density Repeatability | ±0.01% |
| Resolution | 0.01% |
| Minimum Sample Volume | 0.3 cm³ |
| Standard Sample Cell Volumes | 20 mL, 40 mL, 60 mL |
| Optional Sample Cell Volumes | 4 mL, 100 mL |
| Reference Cell Configuration | Three Integrated Reference Cells |
| Pressure Sensor | High-Stability Absolute Sensor (0–2.5 bar), 19-bit A/D, Drift ≤ ±0.02 mbar |
| Gas Options | He (standard), N₂, SF₆ |
| Inlet Pressure Range | 160–240 kPa (1.6–2.4 bar) |
| Compliance | ASTM D5550, ISO 12154, USP <699>, ISO 4590, ASTM D6226-10 |
| Interface | RS-232 (COM) or USB |
| Dimensions (W×H×D) | 25 × 33 × 45 cm |
| Weight | 17 kg |
| Operating Environment | 15–30 °C, 20–80% RH |
| Power | 85–264 VAC, 50/60 Hz, 240 W |
| Brand | Microtrac |
|---|---|
| Model | BELPYCNO |
| Type | Benchtop True Density Analyzer for Solids |
| Measurement Principle | Gas Pycnometry (Helium/Nitrogen/SF₆) |
| Density Range | All Solid Materials |
| Density Accuracy | ±0.0001 g/cm³ |
| Repeatability | ±0.01% (RSD) |
| Resolution | 0.01% |
| Minimum Sample Volume | 0.3 cm³ |
| Temperature Range | 15–35 °C (standard) |
| Pressure Range | Atmospheric to 150 kPa |
| Safety Features | Integrated pressure relief valve |
| Calibration Standards | Internal calibration spheres (multiple sizes) |
| Compliance | ASTM D5550, ISO 12154, USP <699>, ISO 18857-1 |
| Software | BELPyCNOSoft v3.x with audit trail, user management, and 21 CFR Part 11 compliance options |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | ND-11 |
| Pricing | Upon Request |
| Measurement Parameters | Reflectance Density (OD), Reflectance (%) |
| Measurement Range | 0.00–100.0% (Reflectance), 0.00–3.00 D (Optical Density) |
| Aperture Sizes | Φ3.0 mm, Φ1.7 mm, Φ1.0 mm |
| Illumination/Reception Geometry | 0° vertical illumination / 45° annular edge reception |
| Accuracy (Repeatability) | ±0.01 D (≤2.0 D, Φ3.0 mm) |
| Data Compensation Function | Yes, for cross-model result compatibility |
| Averaging Function | 2–9-point reflectance intensity averaging |
| Data Storage Capacity | Up to 500 measurements |
| Dimensions | 210 × 72 × 50 mm (L × D × H) |
| Weight | 530 g (including Ni-Cd battery) |
| Power Supply | Built-in 4.8 V / 800 mAh Ni-Cd rechargeable battery |
| Light Source | Tungsten-halogen lamp (CCT ≈ 2856 K) |
| Optional Accessories | Serial printer PR-95, RS-232 cable, PC software for Excel-compatible data export, calibration standard plates |
| Brand | Ortelli |
|---|---|
| Origin | Italy |
| Model | MVS2pro |
| Instrument Type | Buoyancy-Based Density Analyzer |
| Configuration | Benchtop Laboratory System |
| Sample Type | Solids (films, rods, granules) |
| Density Range | 0–2 g/cm³ |
| Temperature Control Range | 10–40 °C (standard test temp: 23 °C) |
| Cycle Time | ~3–5 min per sample |
| Auto-sampler Capacity | 16-position robotic arm |
| Compliance | ISO 1183-1, ISO 9001 |
| Brand | Pharma Test |
|---|---|
| Origin | Germany |
| Model | PT-TD300 |
| Standards Compliance | USP <616> Method 1 & 2, EP <2.9.34>, DIN EN ISO 787-11, ASTM B527 |
| Sample Weight Input | Via Connected Balance (RS-232 or USB) |
| Density Calculation | Apparent Density, Tapped Density, Hausner Ratio, Carr Index |
| Output | Integrated Thermal Printer, USB Flash Drive Export (Methods & Reports) |
| Software Architecture | Standalone Embedded System with GLP-Compliant Audit Trail |
| Regulatory Alignment | Designed for GMP/GLP Laboratories, Supports 21 CFR Part 11 Readiness (User Authentication, Electronic Signatures Optional via Firmware Update) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | DMA-135D |
| Instrument Type | Portable Oscillating U-Tube Densimeter |
| Sample Type | Liquids |
| Density Range | 0.001–1.999 g/cm³ |
| Density Accuracy | ±0.01 g/cm³ |
| Temperature Range | 0–50 °C |
| Repeatability | ±0.01 g/cm³ |
| Resolution | 0.001 g/cm³ |
| Minimum Sample Volume | 10 mL |
| Compliance Standards | GB/T 29617–2013, GB/T 2013–2010, SH/T 0604–2000, SN/T 2383–2009, ASTM D4052–11, ASTM D5002–13, ASTM D3505–12e1, ISO 12185:1996, IP 559–2008 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PDM-301A |
| Instrument Type | Laboratory Benchtop Digital Densimeter |
| Measurement Principle | Oscillating U-Tube Method |
| Sample Type | Liquids Only |
| Density Range | 0.0000–3.0000 g/cm³ |
| Density Resolution | ±0.0001 g/cm³ |
| Density Repeatability | ±0.0002 g/cm³ |
| Temperature Control Range | 15–30 °C |
| Temperature Stability | ±0.1 °C |
| Minimum Sample Volume | 10 mL |
| Compliance | ASTM D4052, ASTM D5002, ASTM D3505, ISO 12185, GB/T 29617, GB/T 2013, SH/T 0604, SN/T 2383, DB/T 1231, JJG 1058 |