Electrochemical Instruments
Filter
Showing 61–90 of 473 results
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | DPH-2 Digital Portable pH Meter |
| Instrument Type | Pen-style pH Meter |
| Parameter Type | Single-parameter (pH) |
| Measurement Range | 0.0 to 14.0 pH |
| Resolution | ±0.1 pH (2.0–12.0 pH) |
| Accuracy | ±0.1 pH (2.0–12.0 pH) |
| Temperature Range | 0.0–50.0 °C with Automatic Temperature Compensation (ATC) |
| Calibration Points | 4.0, 7.0, and 10.0 pH buffer solutions |
| Ingress Protection Rating | IP67 |
| Power Supply | Four LR44 button cells |
| Dimensions | 4.5 × 3.0 × 16.3 cm |
| Weight | 90 g (without accessories) |
| Brand | ATS |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Kerr Microscope |
| Price Range | USD 68,000 – 136,000 |
| Magnetic Field | Up to 1.2 T (perpendicular), up to 0.8 T (in-plane) |
| Optical Resolution | Sub-micron (dependent on objective lens) |
| Wavelength Range | 405–1550 nm (configurable) |
| Imaging Frame Rate | Up to 100 fps (full FOV), real-time video acquisition |
| Sample Stage | Motorized XYZ + tilt, vacuum-compatible option available |
| Environmental Control | Temperature-stabilized optical platform, RH < 60 % recommended |
| Power Supply | 220 V, 50 Hz |
| Brand | Auniontech |
|---|---|
| Origin | Shanghai, China |
| Model | d-shot |
| Measurement Principle | Dispersion-Scan (D-scan) |
| Pulse Duration Range | < 50 fs |
| Repetition Rate Support | Single-shot to MHz |
| Compatible Pulse Types | Few-cycle and Multi-cycle Pulses |
| Output | Full Electric Field Reconstruction (Amplitude & Phase) |
| Software | Real-time Retrieval Algorithm with Visual Trajectory Feedback |
| Compliance | Designed for GLP/GMP-aligned ultrafast labs |
| Brand | Metrohm Autolab |
|---|---|
| Origin | Netherlands |
| Manufacturer | Metrohm Autolab B.V. |
| Model | AUT-RDE |
| Rotation Speed Range | 0–10,000 rpm (1 rpm step size, acceleration: 4,000 rpm/s) |
| Speed Control | Manual or external potentiostat-triggered (e.g., Autolab, CHI, Biologic) |
| Speed Feedback | Integrated optical encoder with closed-loop control (±2 rpm accuracy at 10,000 rpm) |
| Contact Method | Dual-seal mercury pool (liquid Hg-based conduction, no carbon brushes required) |
| Sealing | Fully sealed rotating assembly immersed in electrolyte cell |
| Electrode Head Compatibility | Interchangeable RRDE and RDE heads |
| RRDE Head Options | Pt/Pt, Au/Pt, GC/Pt |
| Collection Efficiency | 24.9% (calibrated per ASTM D3765-18 practice) |
| Disk-Ring Gap | 375 µm |
| Max Current Rating | 500 mA |
| Footprint | Compact design optimized for glovebox integration (W × D × H: 185 × 160 × 320 mm) |
| Brand | Autolab |
|---|---|
| Origin | Imported (Netherlands) |
| Instrument Type | Electrochemical Impedance Spectroscopy (EIS) Control & Analysis Software |
| Frequency Range | 10 Hz – 1 MHz (single-sweep, no segmentation required) |
| Supported Measurement Modes | Potentiostatic EIS, Galvanostatic EIS, Potential Sweep EIS, Current Sweep EIS, Time-Resolved EIS |
| Data Visualization | Nyquist, Bode ( |
| Curve Fitting Engine | EQUIVCRT-based equivalent circuit modeling |
| Validation Tools | Kramers–Kronig transform consistency testing |
| Compliance | Fully compatible with Autolab PGSTAT series potentiostats/galvanostats |
| Brand | AWSensors |
|---|---|
| Origin | Spain |
| Model | QCM-D |
| Channel Options | 1-channel or 4-channel modular system |
| Sensor Interface | AT-cut quartz crystals with Cr/Au/Ti electrodes |
| Cell Design | Patented quick-lock mechanism with FFKM or PDMS sealing |
| Measurement Modes | Static (Batch) and dynamic flow-through (Flow) |
| Software Platform | AWSensors Control & Analysis Suite |
| Compliance Framework | Designed for GLP-compliant data integrity |
| Optional Modules | Temperature control unit (±0.1 °C stability), precision flow control unit (integrated dual-position, six-port valve with degassing module), potentiostat integration for electrochemical QCM (EQCM) |
| Brand | Baltic FuelCells |
|---|---|
| Origin | Germany |
| Model | DiLiCo CURR TEMP |
| Instrument Type | Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | ±3 A/cm² |
| Current Accuracy | ±0.01 A (1% of reading) |
| Voltage Range | ≤2.5 V |
| Voltage Resolution | Not specified |
| Potentiostatic Range | 25 V |
| AC Impedance Frequency Range | 10 Hz |
| Temperature Range | ≤120 °C |
| Temperature Accuracy | ±0.5 °C |
| Temperature Scan Interval | 2.0 s |
| Sensor Array | 48 nodes (6 × 8) |
| Node Size | 7 mm × 7 mm (0.5 cm²) |
| Node Material | Gold-plated |
| Communication Interface | CAN, USB |
| External Temperature Inputs | Up to 5 (PT-100/PT-500/PT-1000) |
| Brand | Baltic FuelCells |
|---|---|
| Origin | Germany |
| Model | QCF-125 |
| Active Area per Cell | 25 cm² |
| Max. Number of Cells | 5 |
| Temperature Range | up to 140 °C |
| Contact Pressure | up to 6.28 kN (2.5 N/mm², equivalent to 8 bar) |
| Gas Inlet/Outlet Port Diameter | Ø 8 mm |
| Pneumatic Control Port Diameter | Ø 4 mm |
| Electrical Interface | 1 mm sensor wire socket, 8 mm load current terminal |
| Stack Thickness Adjustment Range | up to 0.9 mm per MEA |
| Dimensions (L×W×H) | 465 × 175 × 242 mm |
| Net Weight | 13.5 kg |
| Brand | Baltic FuelCells |
|---|---|
| Origin | Germany |
| Model | QCF25 |
| Instrument Type | Electrochemical Workstation Accessory |
| Current Range | ±5 A |
| Current Accuracy | ±0.1% of full scale |
| Potential Accuracy | ±15–32 µV |
| Potentiostatic Range | ±25 V |
| EIS Frequency Range | 10 Hz – 1 MHz (system-dependent, requires compatible potentiostat) |
| Brand | Baltic FuelCells |
|---|---|
| Origin | Germany |
| Model | QCF50 |
| Active Area | 50 cm² |
| Pressure Control | Pneumatically Actuated, Continuously Adjustable |
| Temperature Compatibility | –50 °C to +250 °C (with optional TCU) |
| Compliance | Designed for ISO/IEC 17025-compliant lab environments |
| Customization | Available for PEMFC, AEMFC, electrolysis, and metal–air cells |
| Accessories | CMD compression monitor, CSL current distribution scanner, DHRE_Pt reference electrode, HSE humidity sensors, flow-field customization, liquid-cooled/heated manifolds |
| Brand | Baltic FuelCells |
|---|---|
| Origin | Germany |
| Model | SuSy300 |
| Output Power | 300 W (nominal) |
| DC Voltage Range | 16–21 V |
| Rated Current | 18 A |
| System Efficiency | 45% @ 300 W |
| Fuel | 99.9% H₂ + ambient air |
| H₂ Inlet Pressure | 2–20 bar |
| Startup Time | <3 s |
| Safety Monitoring | Integrated H₂ pressure & temperature sensors |
| Gas Port | 1/8" internal thread |
| Control Interface | SUB-D9 connector, RS-232 protocol |
| Dimensions | 244 × 155 × 180 mm |
| Weight | 3.9 kg |
| Brand | Bigdipper |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | T-BD5-MS1200 |
| Price | Upon Request |
| Measurement Principle | Microwave Attenuation at 100 MHz |
| Range | 0.5–100 vol% |
| Accuracy | ±1–5% FS |
| Resolution | <0.01 vol% |
| Sensor Operating Temp. | −10 to 80 °C |
| Max. Process Pressure | 1.6 MPa |
| Output | 4–20 mA (linear) |
| Power Supply | DC 12–24 V |
| Power Consumption | <1.40 W (typ. <0.5 W) |
| Enclosure Rating | IP65 |
| Explosion Protection | Ex d ia IIC T5 |
| Installation Options | NPT 1", DN50 flange, tri-clamp |
| Insertion Depth | 60–230 mm (customizable) |
| Wetted Materials | PTFE, SS304, SS316 |
| Compliance | Designed for GLP/GMP-aligned process monitoring environments |
| Brand | Bio-Logic |
|---|---|
| Origin | France |
| Model | FlexP 0160 |
| Current Range | ±50 A per channel (up to ±200 A with 4-channel parallel configuration) |
| Current Accuracy | ±20 nA on 10 μA range |
| Potential Accuracy | <5 mV on ±2.5 V range |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 10 μHz – 1 MHz |
| Voltage Compliance Range | 1–60 V |
| Voltage Accuracy | 0.2% of reading ± 0.1% FS |
| Current Accuracy (high-current mode) | 0.2% of reading ± 0.1% FS up to 50 A |
| Slew Rate | 1 V/μs |
| Rise/Fall Time | 20 μs |
| Brand | Bio-Logic |
|---|---|
| Origin | France |
| Model | HCP-803 |
| Current Range | ±80 A |
| Current Resolution | 760 pA (1 nA–400 nA range) |
| Current Accuracy | ±20 nA on 10 μA range |
| Potential Accuracy | <5 mV on ±2.5 V range |
| Potentiostatic Range | ±10 V |
| Dynamic Potential Resolution | 300 µV (adjustable down to 5 µV) |
| EIS Frequency Range | 10 µHz–1 MHz (standard), 10 µHz–10 kHz (with 80 A booster) |
| Booster Module | Removable high-current extension unit |
| Brand | Bio-Logic |
|---|---|
| Origin | France |
| Model | HCV-3048 |
| Current Range | ±30 A (per channel), up to ±120 A (4-channel parallel operation) |
| Current Accuracy | 0.1–0.3% (range + reading) |
| Potential Accuracy | <5 mV (on ±2.5 V range) |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 10 µHz – 1 MHz |
| Voltage Range | 0–48 V |
| Voltage Accuracy | 0.03% (range + reading) |
| Slew Rate | >20 V/µs |
| Rise/Fall Time | <3 µs (0–48 V step) |
| Input Impedance | 100 GΩ |
| Bandwidth | 800 kHz |
| Brand | Bio-Logic |
|---|---|
| Origin | France |
| Model | M470 |
| Instrument Type | Scanning Electrochemical Workstation |
| Current Range | 1 pA – 10 A |
| Current Accuracy | ±0.0033% of reading |
| Potential Accuracy | ±1 µV |
| Potentiostatic Range | ±30 V |
| EIS Frequency Range | 10 µHz – 7 MHz |
| Scan Range (X/Y/Z) | >100 mm |
| Closed-Loop Positioning Resolution | 0.1 nm |
| Spatial Resolution (X/Y/Z) | 20 nm |
| Max Scan Speed | 12.5 mm/s |
| ADC/DAC Resolution | 32-bit @ up to 40 MHz |
| Piezo Vibration Range | 20 nm – 2 µm (peak-to-peak, 1 nm step) |
| Piezo Minimum Vibration Resolution | 0.12 nm (16-bit DAC, 4 µm range) |
| Piezo Extension | 100 µm |
| Piezo Positioning Resolution | 0.09 nm (20-bit DAC, 100 µm range) |
| Brand | Bio-Logic |
|---|---|
| Origin | France |
| Model | MPG-2XX |
| Instrument Type | Electrochemical Workstation |
| Current Range | ±40 A |
| Current Accuracy | ±20 nA on 10 μA |
| Potential Accuracy | <5 mV on ±2.5 V |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 10 μHz – 1 MHz |
| Brand | Bio-Logic |
|---|---|
| Origin | France |
| Model | MPG2 |
| Instrument Type | Electrochemical Workstation |
| Current Range | ±10 A (per channel with optional high-current modules) |
| Current Resolution | 760 pA |
| Potential Accuracy | ±5 µV |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 10 µHz – 20 kHz |
| Data Acquisition Rate | 200,000 points/s |
| Channels | 16 independent, fully isolated |
| Voltage Resolution | 300 µV (dynamic range adjustable down to 5 µV) |
| Brand | Bio-Logic |
|---|---|
| Origin | France |
| Model | SP-150e |
| Instrument Type | Portable Electrochemical Workstation |
| Number of Channels | Dual-Channel |
| Current Range | ±1 A |
| Current Resolution | 760 pA (optional 76 fA) |
| Current Accuracy | ±20 nA on 10 μA range |
| Potential Accuracy | <5 mV on ±2.5 V range |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 10 μHz to 1 MHz |
| Voltage Resolution | 300 μV (dynamically adjustable down to 5 μV) |
| Data Acquisition Rate | 200,000 points/s |
| Compliance | CE, RoHS, IEC 61010-1 |
| Brand | Bio-Logic |
|---|---|
| Origin | France |
| Model | SP-200 |
| Instrument Type | Portable Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | ±500 mA |
| Current Resolution | 76 aA |
| Potential Accuracy | ±0.1% of full scale |
| Potentiostatic Range | ±12 V |
| EIS Frequency Range | 10 µHz – 7 MHz |
| Voltage Resolution | 1 µV (dynamic range adjustable down to 1 µV) |
| Data Acquisition Rate | 1,000,000 points/second |
| Optional ULC Module | 100 pA (down to 1 pA) |
| Brand | Bio-Logic |
|---|---|
| Origin | France |
| Model | SP-300 |
| Channel Count | Dual-channel |
| Current Range | ±500 mA |
| Current Resolution | 76 aA |
| Potential Accuracy | ±1 mV |
| Potentiostatic Range | ±48 V |
| EIS Frequency Range | 10 µHz – 7 MHz |
| Data Acquisition Rate | 1,000,000 pts/s |
| Voltage Resolution | 1 µV (dynamic range adjustable) |
| Optional Modules | ULC (1 pA), High-Current (4 A/14 V), High-Voltage (1 A/48 V) |
| Brand | Bio-Logic |
|---|---|
| Origin | France |
| Model | SP-50e |
| Instrument Type | Portable Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | ±1 A |
| Current Accuracy | ±20 nA (on 10 μA range) |
| Potential Accuracy | <5 mV (on ±2.5 V range) |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 10 μHz to 1 MHz |
| Current Resolution | 760 pA |
| Voltage Resolution | Adjustable from 300 μV down to 5 μV |
| Data Acquisition Rate | 200,000 points/s |
| Brand | Bio-Logic |
|---|---|
| Origin | France |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | Uniscan M370 |
| Instrument Type | Electrochemical Workstation |
| Current Range | ±1 A |
| Current Accuracy | ±0.1% of reading |
| Potential Accuracy | ±10 mV |
| Potentiostatic Range | ±20 V |
| AC Impedance Frequency Range | 10 µHz – 1 MHz |
| Brand | Bio-Logic |
|---|---|
| Origin | France |
| Model | VMP-300 |
| Number of Channels | 16 |
| Current Range | ±500 mA |
| Current Accuracy | ±0.1% |
| Potential Accuracy | ±0.1% |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 10 µHz – 7 MHz |
| Voltage Compliance | ±12 V |
| Control Voltage Range | ±10 V |
| Current Resolution (standard board) | 760 fA |
| Floating Mode | Yes |
| Analog Filtering | Built-in |
| Calibration Board | Integrated |
| Control Stability | Digital PID with adaptive tuning |
| Brand | Bio-Logic |
|---|---|
| Origin | France |
| Model | VMP-3e |
| Channel Count | 16 independent channels |
| Current Range | 76 fA to 100 A (with external amplifiers) |
| Current Accuracy | ±0.1% |
| Potential Range | ±10 V (DC), 0–20 V (galvanostatic mode) |
| Potentiostatic Range | ±20 V |
| EIS Frequency Range | 10 µHz to 1 MHz |
| Data Acquisition Rate | 200,000 points/sec |
| Potential Resolution | 300 µV (dynamic range adjustable down to 5 µV) |
| Switching Time (Potentiostatic ↔ Galvanostatic) | <10 µs |
| Input Impedance | >10^14 Ω |
| Brand | Bio-Logic |
|---|---|
| Origin | France |
| Model | VSP |
| Channel Count | 5 independent channels |
| Current Range | 1 nA to 100 A (with external amplifier) |
| Current Resolution | 76 fA |
| Potential Accuracy | ±5 µV |
| Potentiostatic Range | ±10 V |
| Galvanostatic Range | ±4 A (built-in), up to ±100 A (with external current booster) |
| EIS Frequency Range | 10 µHz – 1 MHz |
| Data Acquisition Rate | 200,000 points/s |
| Voltage Resolution | 300 µV (dynamic adjustment down to 5 µV) |
| Supported Techniques | CV, LSV, CA, CP, EIS (potentiostatic/galvanostatic/step-mode), DPV, SWV, NPV, Mott-Schottky, ZRA/ZVC, corrosion polarization, GITT, PITT, constant-power discharge, potentiometric titration, and multi-step sequence protocols |
| Brand | Bio-Logic |
|---|---|
| Origin | France |
| Model | VSP-300 |
| Channel Count | 6 |
| Current Range | ±500 mA |
| Current Resolution | down to 76 aA (with ULC option) |
| Current Accuracy | ±20 nA on 10 µA range |
| Potential Accuracy | <5 mV on ±2.5 V range |
| Potentiostatic Range | ±10 V |
| Galvanostatic Range | ±1 A (extendable to ±20 A) |
| EIS Frequency Range | 10 µHz – 7 MHz |
| Sampling Rate | up to 1 µs |
| Compliance | CE, RoHS, ISO 9001-certified manufacturing |
| Software | EC-Lab® v12+ with FDA 21 CFR Part 11-compliant audit trail option |
| Brand | Bio-Logic |
|---|---|
| Origin | France |
| Model | VSP-3e |
| Channel Count | 8 |
| Current Range | ±1 pA to ±1 A |
| Current Accuracy | ±0.0033% of reading |
| Potential Accuracy | ±1 µV |
| Potentiostatic Range | ±10 V (adjustable up to ±20 V) |
| EIS Frequency Range | 10 µHz to 1 MHz |
| Voltage Resolution | 5 µV (within ±200 mV range) |
| Current Resolution | 0.76 nA |
| Minimum Sampling Interval | 200 µs |
| Control Bandwidth | 7 adjustable bandwidths |
| Connectivity | Ethernet (LAN), USB, optional EIS module |
| Brand | BioLight |
|---|---|
| Model | Lux-T020 |
| Origin | Guangdong, China |
| Detector Type | Electrochemiluminescence & Bioluminescence Luminometer |
| Photomultiplier Tube (PMT) | Single-Photon Counting PMT |
| Max Count Rate | >100 million pulses/sec |
| Detection Sensitivity | ≤10 amol ATP or 20 zmol firefly luciferase |
| Dynamic Range | 7 decades (linear) |
| Sample Format | 12 × 55 mm test tubes or standard 0.5–2.0 mL microcentrifuge tubes |
| Interface | Touchscreen GUI with USB data export |
| Compliance | Designed for GLP-compliant workflows |