Electrochemical Instruments
Filter
Showing 151–180 of 1703 results
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | BlueLine 13 pH |
| Electrolyte | KCl 3 mol/L |
| Reference System | Ag/AgCl spherical |
| Glass Type | A-glass |
| Body Material | Glass |
| Connection | Ground-joint (standard) |
| Total Length | 170 mm |
| Diameter | 12 mm |
| Temperature Range | −5 to +100 °C |
| pH Range | 0–14 |
| Compliance | ISO 8655-4, DIN 19263, ASTM D1293 |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | BlueLine 22 pH |
| Electrode Type | Combination pH Electrode |
| pH Range | 0–14 |
| Temperature Range | –5 to +80 °C |
| Body Material | Polymer (12 mm Ø, 120 mm length) |
| Reference System | Ag/AgCl |
| Reference Electrolyte | KCl 3 mol/L (gel-free, refillable) |
| Junction Type | Fibrous diaphragm |
| Sensing Membrane | Conical glass |
| Zero Point | pH 7.0 ± 0.3 |
| Membrane Resistance (25 °C) | 200 MΩ |
| Connector Options | DIN 19262, BNC, IDS, or threaded |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | CAS3070 |
| pH Range | 2.0–12.0 |
| pH Resolution | 0.01 |
| pH Accuracy | ±0.1 |
| Dissolved Oxygen Range | 0–30.0 ppm |
| DO Resolution | 0.1 ppm |
| DO Accuracy | ±1 ppm |
| Conductivity Range | 0–69.9 mS/cm |
| Conductivity Resolution | 0.1 µS/cm |
| Conductivity Accuracy | ±2% FS |
| Salinity Range | 0–42.0 ppt |
| Salinity Resolution | 0.1 ppt |
| Salinity Accuracy | ±1% FS |
| Temperature Range | 0–60.0 °C |
| Temp Resolution | 0.1 °C |
| Temp Accuracy | ±0.5 °C |
| Operating Temperature | 0–50 °C |
| Protection Rating | IP67 |
| Power Supply | 6 × AAA batteries |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | CAS9010 |
| Instrument Type | Portable |
| Parameter Types | Multi-parameter |
| Measurement Accuracy | ±0.02 pH |
| pH Range | -2.00 to 16.00 |
| mV Range | ±700.0 mV / ±2000 mV |
| Temperature Range | 0 to 120 °C |
| Resolution | 0.01 pH / 0.1 mV / 0.1 °C |
| Calibration Points | 2–5 point |
| ATC Range | 0–120 °C |
| Data Storage | 99 sets with timestamp |
| Power | 4×AAA batteries (1.5 V) |
| Operating Humidity | ≤95% RH (non-condensing) |
| Operating Temperature | 5–40 °C |
| Storage Temperature | -20–60 °C |
| Brand | ChemTron |
|---|---|
| Origin | Italy |
| Model | CAT1-1 Series |
| Instrument Type | General-Purpose Potentiometric Titrator |
| pH Range | 0–14 |
| mV Range | ±2000 mV |
| Current Range | ±10 µA |
| pH Accuracy | ±0.02 pH |
| mV Accuracy | ±2 mV |
| Current Accuracy | ±2 µA |
| Temperature Range | 0–100 °C |
| Temperature Accuracy | ±1 °C |
| Titration Tube Capacity | 10 mL (dual-mountable) |
| Titration Resolution | 12,000 steps |
| Titration Accuracy | <0.2% (2 µL for 10 mL tube) |
| Titration Repeatability | ±0.2% |
| Pump Flow Rate | 1 mL/s (up to 3 peristaltic pumps) |
| Display | 4.3″ capacitive touchscreen |
| Built-in Methods | 30 (including EP, EQ, Free SO₂, Total SO₂, Double SO₂) |
| Data Storage | 50 titration results + 10 calibration records |
| Interface | pH/mV/µA electrode ports, USB-A, USB-B, RS232, Bluetooth |
| Brand | JULABO-Chemtron |
|---|---|
| Origin | Italy |
| Model | CAT1-16 Series |
| Instrument Type | General-purpose Automatic Potentiometric Titrator |
| pH Range | 0–14 |
| mV Range | ±2000 mV |
| Current Range | ±10 µA |
| Temperature Range | 0–100 °C |
| pH Accuracy | ±0.02 pH |
| pH Resolution | ±0.01 pH |
| mV Accuracy | ±2 mV |
| mV Resolution | ±0.1 mV |
| Current Accuracy | ±2 µA |
| Current Resolution | ±0.1 µA |
| Temperature Accuracy | ±1 °C |
| Temperature Resolution | ±0.1 °C |
| Burette Volume | 10 mL (dual configurable) |
| Burette Precision | <0.2% (2 µL @ 10 mL) |
| Burette Repeatability | ±0.2% |
| Pump Flow Rate | 1 mL/s |
| Display | 4.3″ capacitive touchscreen |
| Method Storage | 30 preloaded templates (EP, EQ, Free SO₂, Total SO₂, Double SO₂) |
| Data Storage | 50 titration reports + 10 calibration records |
| Interface | pH/mV/µA electrode ports, USB-A, USB-B, RS232, Bluetooth |
| Brand | JULABO-Chemtron |
|---|---|
| Origin | Italy |
| Model | CAT2-1 Series |
| Instrument Type | General-Purpose Potentiometric Titrator |
| pH Range | 0–14 |
| mV Range | ±2000 mV |
| Current Range | ±10 µA |
| pH Accuracy | ±0.02 pH |
| pH Resolution | ±0.01 pH |
| mV Accuracy | ±2 mV |
| mV Resolution | ±0.1 mV |
| Current Accuracy | ±2 µA |
| Current Resolution | ±0.1 µA |
| Temperature Range | 0–100 °C |
| Temperature Accuracy | ±1 °C |
| Temperature Resolution | ±0.1 °C |
| Burette Capacity | 10 mL (dual mountable) |
| Burette Precision | <0.2% (2 µL @ 10 mL) |
| Burette Repeatability | ±0.2% |
| Burette Resolution | 12,000 steps |
| Peristaltic Pump Flow Rate | 1 mL/s (up to 3 modules) |
| Method Storage | 30 preloaded templates (EP, EQ, Free SO₂, Total SO₂, Double SO₂) |
| Data Storage | 50 titration reports + 10 calibration records |
| Interfaces | pH/mV/µA electrode ports, USB-A, USB-B, RS232, Bluetooth |
| Display | 4.3″ capacitive touchscreen |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | CAT2-16 |
| Instrument Type | General-purpose Potentiometric Titrator |
| pH Range | 0–14 |
| pH Accuracy | ±0.02 |
| pH Resolution | ±0.01 |
| Titration Accuracy | ±0.02 pH |
| Titration Resolution | ±0.01 pH |
| Display | 4.3″ Touchscreen |
| Burette Capacity | 10 mL (up to two mounted) |
| Burette Resolution | 12,000 steps |
| Burette Accuracy | <0.2% (2 µL for 10 mL) |
| Burette Repeatability | ±0.2% |
| Peristaltic Pump Flow Rate | 1 mL/s (up to three units) |
| mV Range | ±2000 mV, Accuracy: ±2 mV, Resolution: ±0.1 mV |
| Current Range | ±10 µA, Accuracy: ±2 µA, Resolution: ±0.1 µA |
| Temperature Range | 0–100 °C, Accuracy: ±1 °C, Resolution: ±0.1 °C |
| Pre-programmed Methods | 30 (incl. EP, EQ, Free SO₂, Total SO₂, Double SO₂) |
| Calibration Modes | Auto-buffer recognition, zero-point, zero-slope, Nernst equation, wine-specific calibration |
| Data Storage | 50 titration reports, 10 calibration records |
| Interfaces | pH/mV electrode port, µA electrode port, USB-A, USB-B, RS232, Bluetooth |
| Brand | JULABO-Chemtron |
|---|---|
| Origin | Italy |
| Model | CAT2-35 Series |
| Titration Types | Endpoint, Equivalence Point, Linear, Dynamic, Continuous pH Monitoring |
| pH Range | 0–14 |
| mV Range | ±2000 mV |
| Current Range | ±10 µA |
| Temperature Range | 0–100 °C |
| pH Accuracy | ±0.02 |
| pH Resolution | ±0.01 |
| mV Accuracy | ±2 mV |
| mV Resolution | ±0.1 mV |
| Current Accuracy | ±2 µA |
| Current Resolution | ±0.1 µA |
| Temperature Accuracy | ±1 °C |
| Temperature Resolution | ±0.1 °C |
| Burette Capacity | 10 mL (dual mountable) |
| Burette Precision | <0.2% (2 µL @ 10 mL) |
| Burette Repeatability | ±0.2% |
| Pump Flow Rate | 1 mL/s (up to 3 peristaltic pumps) |
| Display | 4.3″ capacitive touchscreen |
| Method Storage | 30 preloaded templates (EP, EQ, Free/Total SO₂, Double SO₂) |
| Data Storage | 50 titration reports + 10 calibration records |
| Interfaces | pH/mV/µA electrode ports, USB-A, USB-B, RS232, Bluetooth |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | CON600 |
| Configuration | Benchtop |
| Application | Laboratory Use |
| Conductivity Range | 0–199.9 mS/cm (5 ranges: 0–19.99 µS/cm, 0–199.9 µS/cm, 0–1999 µS/cm, 0–19.99 mS/cm, 0–199.9 mS/cm) |
| TDS Range | Adjustable factor 0.3–1.00 |
| Temperature Range | 5–40 °C (measurement), 0–80 °C (auto-compensation) |
| Accuracy | ±1% F.S. + 1 digit |
| Minimum Resolution | 0.01 µS/cm |
| Data Storage | 99 sets with timestamp |
| Interface | RS232 (optional AX30-232-RS232PC kit) |
| Dimensions | 217 × 168 × 58 mm |
| Weight | 2.1 kg |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | CON90 |
| Portability | Portable |
| Conductivity Range | 0–19.99 mS/cm |
| Salinity Range | 0–100 ppt |
| Temperature Range | 0–120 °C |
| Minimum Resolution | 0.01 µS/cm / ppm |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | HandyLab 200 |
| Portability | Portable |
| Application | Laboratory |
| TDS Range | 0–1999 mg/L, 0–199.9 g/L |
| Resistivity Range | 1.000 Ω·cm – 199.9 MΩ·cm |
| Salinity Range | 0.0–70.0 (IOT) |
| Temperature Range | −5.0–+105.0 °C |
| Conductivity Range | 0.000–1999 mS/cm (with K=0.01, 0.1, 1.0 cm⁻¹ electrodes) |
| Accuracy | ±0.5% of reading (typical) |
| Data Storage | 200 manual entries |
| IP Rating | IP67 |
| Display | Backlit monochrome LCD |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | HandyLab 600 |
| pH Range | -0.000–14.000, ±0.004 pH |
| mV Range | -1200.0–+1200.0 mV, ±0.2 mV |
| Temperature Range | -5.0–+105.0 °C, ±0.2 °C |
| Data Storage | 500 manual + 5,000 automatic datasets |
| Calibration | 1–5 points, with 22 built-in standard buffer sets |
| Display | Backlit monochrome LCD |
| Interface | USB-B (Mini) |
| Ingress Protection | IP67 |
| Power | Rechargeable battery operation |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | HandyLab 680 |
| IP Rating | IP67 |
| Electrode Interface | IDS Digital Signal |
| Channels | Dual-channel (simultaneous measurement) |
| pH Range & Accuracy | –0.000 to 14.000, ±0.004 pH |
| mV Range & Accuracy | –1200.0 to +1200.0 mV, ±0.2 mV |
| Conductivity Range & Accuracy | 0.00 to 2000 mS/cm, ±0.5% of mean value |
| Resistivity Range & Accuracy | 0.00 Ω·cm to 100 MΩ·cm, ±0.5% of mean value |
| Salinity Range & Accuracy | 0.0 to 70.0 ppt (IOT), ±0.5% of mean value |
| TDS Range & Accuracy | 0 to 1999 mg/L or 0 to 199.9 g/L, ±0.5% of mean value |
| Temperature Range & Accuracy | –5.0 to +105.0 °C, ±0.2 °C |
| Dissolved Oxygen (DO) Range & Accuracy | 0.00 to 20.00 mg/L, ±0.5% of reading |
| Oxygen Saturation Range & Accuracy | 0.0 to 200.0%, ±0.5% of reading |
| Oxygen Partial Pressure Range & Accuracy | 0 to 400 hPa, ±0.5% of reading |
| Calibration | 1–5 point, 22 preconfigured buffer sets |
| CMC (Continuous Measurement Control) | Yes |
| QSC (Quality Sensor Check) | Yes |
| Data Storage | 500 manual + 10,000 automatic datasets |
| User Management | Role-based access control |
| Connectivity | USB-B (Mini-B) and USB-A ports |
| Power | Rechargeable battery (operational without external power) |
| Display | Backlit high-contrast LCD |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Type | pH Combination Electrode |
| pH Range | 0–14 |
| Temperature Range | −5 to 100 °C |
| Reference System | Iodine/Iodide |
| Zero Point | pH 7.00 ± 0.25 |
| Shaft Material | Glass |
| Membrane Resistance | 200–400 MΩ |
| Junction Types | Platinum or Ceramic |
| Membrane Shape | Spherical, Cylindrical, or Spear-shaped |
| Connector Options | DIN, BNC, S7 Thread, Metrohm (R-type), BNC+Cinch, DIN+baa, BNC+baa, Metrohm+2baa |
| Integrated Temperature Sensor | Pt1000 (standard), NTC30 (select models) |
| Auto-ID Recognition | Yes (for compatible meters) |
| Compliance | Designed for GLP/GMP-compliant workflows |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | Lab 855 |
| Instrument Type | Benchtop |
| Parameter Types | Multi-parameter |
| Measurement Precision | 0.001 pH |
| Resolution | 0.01 pH |
| Accuracy | ±0.1 pH |
| pH Range | –2.000 to 19.999 |
| pH Accuracy | ±0.005 pH (at 25 °C, calibrated) |
| mV Range | ±1200.0 mV / ±2000 mV |
| mV Accuracy | ±0.3 mV / ±1 mV |
| Temperature Range | –5.0 to 105.0 °C |
| Temperature Accuracy | ±0.1 °C |
| Calibration Points | 1–3 point automatic or manual |
| Auto-Read Function | Yes |
| Temperature Compensation | Automatic & Manual |
| Calibration Memory | 1 set stored |
| Data Storage Capacity | 500 or 5000 readings (configurable) |
| Display | LCD |
| Electrode Interface | DIN |
| Connectivity | Mini USB-B |
| Compliance | GLP/AQS compliant |
| Power Supply | AC adapter or battery operation |
| CMC Detection | Supported |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | Lab 865 |
| Instrument Type | Benchtop |
| Parameter Types | Multi-parameter |
| pH Accuracy | ±0.1 pH (range –2.0 to 20.0) / ±0.01 pH (range –2.00 to 20.00) / ±0.005 pH (range –2.000 to 19.999) |
| pH Resolution | 0.001 pH |
| mV Accuracy | ±0.3 mV (±1200.0 mV range) / ±1 mV (±2500 mV range) |
| Temperature Accuracy | ±0.1 °C (–5.0 to 105.0 °C) |
| Temperature Compensation | Automatic or Manual |
| Calibration Points | Up to 5-point pH, 2- to 7-point ISE |
| Calibration Memory | 10 calibrations |
| Calibration Timer | Built-in |
| Data Storage | 500 or 5000 readings* |
| Communication Interface | Mini USB-B |
| GLP/AQS Compliance | Yes |
| Display | Graphic monochrome backlit LCD |
| Electrode Interface | DIN |
| Power Supply | AC adapter or battery operation |
| CMC Measurement | Supported |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | Lab 875 / Lab 875P |
| Measurement Parameters | pH, mV, Dissolved Oxygen (DO) Saturation & Concentration & Partial Pressure, Conductivity, Resistivity, Salinity, TDS, Temperature |
| Electrode Compatibility | IDS (Intelligent Digital Sensor) electrodes |
| pH Calibration Points | 1–5 |
| DO Calibration | 1-point (air saturation or zero) |
| Conductivity Calibration | 1-point |
| Calibration Records Stored | ≤10 sets |
| Calibration Timer | 1–999 days |
| Data Storage | 500 manual + 4,500 automatic entries |
| Temperature Compensation | Automatic for all parameters except ORP |
| GLP/AQS Compliance | Yes |
| Printer Support | External printer (Lab 875P includes integrated thermal printer) |
| Communication Interface | Mini USB-B |
| Power Supply | 4 × 1.5 V AA batteries or AC adapter |
| Additional Features | CMC (Continuous Measurement Control), QSC (Quick Sensor Check) |
| Software Export Format | CSV |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | Lab 955 |
| Instrument Type | Benchtop |
| Parameter Types | Dual (pH & Conductivity) |
| pH Range | –2.0 to 20.0 (±0.1), –2.00 to 20.00 (±0.01), –2.000 to 19.999 (±0.005) |
| mV Range | ±1200.0 mV (±0.3 mV), ±2000 mV (±1 mV) |
| Conductivity Range | 0.00–1000 mS/cm (±0.5% of reading) |
| Resistivity | 0.00–99.9 MΩ·cm |
| Salinity | 0.0–70.0 (IOT standard) |
| TDS | 1–999 mg/L |
| Temperature Range | –5.0 to +105.0 °C (±0.1 °C) |
| Temperature Compensation | None, Nonlinear (nlF), Linear (0.000–3.000 %/K), Auto or Manual |
| Cell Constants | Fixed K = 0.01 cm⁻¹ |
| Calibration Range | 0.450–0.500 cm⁻¹, 0.800–0.880 cm⁻¹ |
| Memory Capacity | 500 / 5000 readings* |
| Calibration Points | 1-point pH |
| GLP/AQS Compliance | Yes |
| CMC Function | Yes |
| Interface | Mini USB-B |
| Electrode Connector | DIN pH-2.0 |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Type | pH and ORP Composite Electrodes |
| Connection | BNC |
| Cable Length | 1 m |
| Housing Material | Plastic or Glass (model-dependent) |
| Temperature Range | −5 °C to 130 °C (varies by model) |
| pH Range | 0–14 pH |
| ORP Range | ±1200 mV |
| Pressure Rating | Up to 6 bar (glass models) |
| Compliance | CE, RoHS, ISO/IEC 17025-compatible calibration traceability |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | pH610 |
| Measurement Range | 0–14 pH |
| Resolution | 0.01 pH |
| Accuracy | ±0.02 pH |
| Calibration Points | 5-point |
| Calibration Standards | ASTM, ISO (pH 4.01, 7.00, 10.01), NIST (pH 4.01, 6.86, 9.18) |
| Temperature Range | 0–90 °C |
| Temperature Accuracy | ±0.5 °C |
| mV Range | ±1999 mV |
| mV Accuracy | ±0.2 mV (±2 mV for full scale) |
| Power Supply | 9–12 V DC, min. 650 mA |
| Dimensions | 217 × 168 × 58 mm |
| Weight | 2.1 kg |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | ProLab 2500 |
| Measurement Channels | 3 |
| Display | Color Graphic LCD |
| Electrode Interface | IDS (Intelligent Digital Sensor) compatible |
| pH Calibration Points | 1–5 |
| ISE Calibration Points | 2–7 (with adapter) |
| DO & Conductivity Calibration | 1-point each |
| Temperature Compensation | Automatic for all parameters except ORP |
| Data Storage | 500 manual + 10,000 automatic entries |
| Connectivity | USB-A, Mini USB-B |
| Compliance | GLP/AQS compliant |
| Power Supply | Mains-powered (no battery) |
| Keyboard | Antimicrobial membrane keypad |
| Firmware | Field-upgradable |
| Printer Support | Yes (external) |
| Additional Features | CMC (Continuous Measurement Control), QSC (Quality Sensor Check), Zinc die-cast housing |
| Brand | ChemTron |
|---|---|
| Origin | Italy |
| Model | RFOZNO |
| Type | Reference Electrolyte Solution (Ag/AgCl-free) |
| Volume Options | 125 mL, 500 mL |
| Compliance | ISO 3696 Grade 2, ASTM E200-22, NIST-traceable pH certification available per batch |
| Packaging | Amber glass bottles with PTFE-lined caps |
| Shelf Life | 24 months unopened, 6 months after opening (stored at 15–25 °C, protected from light and CO₂) |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | ScienceLine A 1180 |
| Electrode Type | pH Glass Indicator Electrode |
| Body Material | Borosilicate Glass (Ø12 mm) |
| Sensing Membrane | Spherical Bulb |
| Zero Point | pH 7.0 ± 0.3 |
| pH Range | 0–14 |
| Temperature Range | 0–80 °C |
| Connection | L 1 A Cable |
| Interface | Standard Threaded Connector (DIN 19217) |
| Compliance | ISO 3696 Class 3 water compatibility, ASTM E70, DIN 19265 |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | ScienceLine A 161 1M-DIN-ID |
| Electrode Type | Combination pH/temperature sensor |
| Reference System | Silamid® |
| Body Material | Glass |
| pH Range | 0–14 |
| Zero Point | pH 7.0 ± 0.3 |
| Filling Solution | 3 mol/L KCl |
| Temperature Sensor | Pt1000 |
| Sensing Membrane Shape | Spherical |
| Junction Type | Platinum wire (A-5) |
| Temperature Range | –5 to +100 °C |
| Connector | DIN 19262 + 4-mm pin, with automatic electrode ID recognition |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | ScienceLine A 157 |
| Electrode Type | pH Combination Electrode |
| Reference System | Silamid Ag/AgCl |
| Electrode Body Material | Glass (L39 variant: Polypropylene) |
| Zero Point | pH 7.0 ± 0.3 |
| Filling Solution | 3 mol/L KCl (L8880 variant: Referid electrolyte) |
| Sensing Membrane Type | A |
| Connector | SMEK threaded (optional: LS1 ANN, DIN, BNC) |
| Sensing Element Geometry | Cylindrical |
| Temperature Range | –5 to +100 °C |
| pH Measurement Range | 0–14 |
| Membrane Material | Platinum-doped glass |
| Diaphragm Material | Ceramic (standard), porous polyethylene (L8880), or fiber (L39) |
| Integrated Temperature Sensor | Pt1000 (models marked “1M-ID”) |
| Auto-ID Recognition | Yes (DIN/BNC-ID variants) |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | ScienceLine A7780 |
| Electrode Type | pH Combination Electrode |
| Reference System | Silamid® |
| Body Material | Glass |
| Zero Point | pH 7.0 ± 0.3 |
| Filling Electrolyte | KCl 3 mol/L (Gel) |
| Sensing Membrane Shape | Spherical |
| pH Range | 0–14 |
| Temperature Range | –5 °C to +80 °C |
| Junction Type | Ceramic |
| Shaft Diameter | 12 mm |
| Length | 120 mm |
| Connector | Standard Threaded (BNC/DIN compatible via adapter) |
| Compliance | ISO 3696, ASTM D1193 (Type II water for calibration), GLP-ready documentation support |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | ScienceLine Ag 42 A |
| Electrode Type | Reference and Working Electrodes for Electrochemical Analysis |
| Temperature Range | −5 to +100 °C (Pt 6140: +10 to +40 °C) |
| Reference System | Silamid® Ag/AgCl |
| Electrode Body Material | Glass |
| Electrolyte | KCl 3 mol/L |
| Junction Type | Ceramic Frit |
| Sensor Geometry | Cap-type (Ag), Rod-type (Pt), Ring-type (Pt), or Disc-type (Au/Pt) |
| Diameter Options | 5 mm (Ag), 1–6 mm (Pt/Au), 12 mm (body) |
| Length Options | 103–170 mm |
| Connector Options | DIN, BNC, or Standard Threaded (M8×0.75 or L1A) |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | ScienceLine B 2220+ |
| Electrode Type | Single-Reference Electrode |
| Body Material | Glass |
| Reference System | Ag/AgCl (3 mol/L KCl) |
| Temperature Range | −5 °C to +100 °C |
| pH Range | 0–14 |
| Junction Type | Double-Liquid-Junction |
| Sensing Element | Platinum |
| Connection | L 1 N Cable |
| Compliance | ASTM D1129, ISO 7888, USP <798>, GLP-ready configuration |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | ScienceLine LF 213 T |
| Cell Constant | 0.01 cm⁻¹ |
| Electrode Material | Stainless Steel Ring |
| Temperature Sensor | NTC 30 kΩ |
| Operating Temp. Range | 0–100 °C |
| Conductivity Range | 0.03–1000 µS/cm |
| Electrode Body Diameter | 12 mm |
| Cable Length | 1.5 m |
| Housing | Stainless Steel |
| Compliance | ASTM D1125, ISO 7888, USP <645>, EN 27888 |
| Features | Integrated Flow-Through Cell, Fixed Connector |