| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic (China-manufactured) |
| Models | ET18 / ET28 / ET38 / ET58 / Easy Na |
| Price Range | USD 700 – 7,000 (FOB) |
| Instrument Type | General-purpose Potentiometric Titrator |
| Application Scope | Universal |
| Measurement Ranges | pH: 1–14 |
| mV | 0–2000 mV |
| Temperature | 0–100 °C |
| Meter Accuracy | ±0.2% of full scale |
| Resolution | pH: 0.01 pH |
| mV | 0.1 mV |
| Temperature | 0.1 °C |
| Titration Stability | (±0.3 mV ±1 digit) over 3 hours |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Domestic (China) |
| Models | ET18 / ET28 / ET38 / ET58 / Easy Na |
| Instrument Type | General-purpose Potentiometric Titrator |
| Application Scope | Universal |
| Measurement Ranges | pH: 1–14 |
| mV | 0–2000 mV |
| Temperature | 0–100 °C |
| Meter Accuracy | ±0.2% of full scale |
| Meter Resolution | pH: 0.01 pH |
| mV | 0.1 mV |
| Temperature | 0.1 °C |
| Titration Stability | (±0.3 mV ±1 digit) over 3 h |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | ET Series (ET08/ET12/ET15/ET18/ET28/ET38/ET58) |
| Type | Benchtop Automatic Potentiometric Titrator |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Software Interface | EasyDirect™ (PC-based), iTitrat™ intelligent calculation engine |
| Titration Drive Resolution | 12,000 steps per full stroke |
| Display | Capacitive touchscreen interface |
| Liquid Handling | Motorized burette with programmable dosing modes (fixed-volume dispensing, manual titration assist, auto-titration) |
| Brand | METTLER TOLEDO |
|---|---|
| Principle | Coulometric Karl Fischer Titration |
| Measurement Range | 1 µg – 200 mg H₂O |
| Detection Limit | ≤ 0.1 µg H₂O |
| Electrode Recognition | Integrated Smart Chip Interface |
| Cell Design | Modular Two-Part Coulometric Titration Vessel |
| Optional Accessories | Amber Cell, Thermostatted Cell, InMotion KF Oven Integration |
| Compliance | ASTM D6304, ISO 8534, USP <921>, EP 2.5.12, GLP/GMP Data Integrity Ready |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Manufactured in China (for global distribution) |
| Manufacturer Type | Authorized Distribution Channel |
| Model | EVA V1 |
| Pricing Range | USD 19,500 – 22,000 (FOB) |
| Titration Principle | Volumetric Coulometric/KF Endpoint Detection via Bipotentiometric Electrode System |
| Dispensing Resolution | 120,000 steps per burette revolution |
| Control Algorithm | Fast Feedback Algorithm (FFA) for dynamic reagent dosing |
| Software Platform | LabX™ PC-based titration software with audit trail and electronic signature support |
| Compliance | Designed to support GLP/GMP workflows |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Manufactured in China (for global distribution) |
| Manufacturer Type | Authorized Distribution Channel |
| Model | EVA V3 |
| Pricing Range | USD 24,000 – 27,000 (FOB) |
| Titration Principle | Volumetric Karl Fischer (KF) |
| Electrode Type | Dual-platinum generator and indicator electrodes |
| Reagent Delivery Precision | ±0.001 mL per 120,000-step motorized burette |
| Sample Throughput | Up to 30 samples per hour (with autosampler option) |
| Compliance | Fully compatible with FDA 21 CFR Part 11, ISO/IEC 17025, and GLP/GMP data integrity requirements |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Instrument Type | Benchtop |
| Model | FE20 |
| pH Range | 0.00–14.00 |
| pH Resolution | 0.01 |
| Relative pH Accuracy | ±0.01 |
| mV/ORP Range | −1999 to +1999 mV |
| mV Resolution | 1 mV |
| Relative mV Accuracy | ±1 mV |
| Temperature Range | 0.0–100.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.5 °C |
| Calibration | Up to 3-point, with 4 pre-defined buffer sets |
| Display | LCD |
| Power Supply | External AC adapter |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | FE20K |
| Instrument Type | Benchtop (not portable) |
| Parameter Type | Single-parameter (pH/mV/ORP) |
| pH Range | 0.00–14.00 |
| pH Resolution | 0.01 |
| pH Accuracy | ±0.01 |
| mV Range | −1999 to +1999 mV |
| mV Resolution | 1 mV |
| mV Accuracy | ±1 mV |
| Temperature Range | 0.0–100.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.5 °C |
| Calibration | Up to 3-point, with auto-buffer recognition for 4 pre-defined IUPAC/NIST-compatible buffers |
| Data Storage | 99 measurement records |
| Interface | RS232 |
| Display | Backlit LCD showing pH/mV value, temperature, endpoint status, and calibration indicators |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | FE28 / S210-K |
| Instrument Type | Benchtop |
| Parameter Types | Dual (pH + mV/ORP) |
| pH Range | −2.00–16.00 pH (FE28) / −2.000–20.000 pH (S210-K) |
| pH Resolution | 0.01 pH (FE28) / 0.001–0.1 pH selectable (S210-K) |
| pH Accuracy | ±0.01 pH (FE28) / ±0.002 pH (S210-K) |
| mV Range | ±2000 mV (FE28) / ±2000.0 mV (S210-K) |
| mV Resolution | 1 mV (FE28) / 0.1 or 1 mV selectable (S210-K) |
| mV Accuracy | ±1 mV (FE28) / ±0.2 mV (S210-K) |
| Temperature Range | −5 to 105 °C (FE28, manual/auto) / −30.0 to 130.0 °C (S210-K, manual) |
| Temperature Accuracy | ±0.1 °C (S210-K) |
| Calibration Points | Up to 5-point pH calibration |
| Buffer Recognition | Automatic (NIST, DIN, JIS, ISO, METTLER TOLEDO standard buffers) |
| Data Storage | 200 measurement records |
| Connectivity | RS232 and USB |
| Electrode Interface | Standard BNC (FE28) / ISM-enabled Smart Socket (S210-K) |
| Temperature Compensation | Automatic and manual |
| Compliance | Designed for GLP/GMP environments |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Germany |
| Model | FE28-Meter |
| Instrument Type | Portable |
| Parameter Types | pH, Conductivity, Dissolved Oxygen |
| pH Measurement Range | −2.00 to 16.00 |
| pH Resolution | 0.01 |
| pH Accuracy | ±0.01 (at 25 °C) |
| pH Calibration Points | Up to 5 |
| Predefined Buffer Sets | 4 |
| Temperature Range | 0 to 105 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.3 °C |
| Temperature Compensation | Automatic (ATC) and Manual (MTC) |
| Data Storage | 200 measurement records + active calibration data |
| Interface | RS232 and USB |
| Reference Input | Yes |
| Audible Signal | Yes |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Italy |
| Model | FE28 |
| Instrument Type | Benchtop |
| Parameter Types | pH and mV (single-channel) |
| pH Measurement Range | -2 to 16 |
| pH Resolution | 0.01 / 0.1 |
| pH Accuracy | ±0.01 |
| mV Measurement Range | 0 mV |
| mV Resolution | 1 mV |
| mV Accuracy | ±1 |
| Temperature Range | -5 °C to 105 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.3 °C |
| Data Storage Capacity | 200 measurements |
| Connectivity | RS232 and USB |
| Electrode Included | LE438 pH electrode |
| ISM Support | Not supported |
| Calibration Solution Compatibility | China-specific calibration buffers |
| Compliance | Designed for GLP-compliant routine lab use |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Germany |
| Model | FE28-Standard |
| Instrument Type | Benchtop (not portable — corrected per technical specification) |
| Parameter Types | pH, mV, Temperature |
| Measurement Range | -2.00 to 16.00 pH |
| Resolution | 0.01/0.1 pH, 1 mV, 0.1 °C |
| Accuracy | ±0.01 pH, ±1 mV, ±0.3 °C |
| Temperature Compensation | Automatic and Manual |
| Calibration Points | Up to 5-point |
| Calibration Modes | Linear and Segmented |
| Predefined Buffers | 4 sets (including US, NIST, DIN, and Chinese standards) |
| Data Storage | 200 measurement records + current calibration data |
| Connectivity | BNC, Cinch, NTC 30 kΩ, RS232, USB |
| Display | 4.3-inch segmented LCD |
| Housing Material | ABS |
| Dimensions / Weight | 227 × 147 × 70 mm / 0.63 kg |
| Power Supply | 100–240 V AC, 50–60 Hz / 12 V DC |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | FE30 / FE30K |
| Instrument Type | Benchtop |
| Parameter Types | Conductivity, TDS, Salinity, Resistivity, Temperature |
| Measurement Range | 0.00 µS/cm – 199.9 mS/cm (equivalent to 0.00 mg/L – 199.9 g/L TDS) |
| Resolution | Automatic, 0.01 µS/cm to 0.1 mS/cm (conductivity) |
| Accuracy | ±0.5% of reading |
| Calibration Solutions | Standardized US-type conductivity standards (e.g., 84 µS/cm, 1413 µS/cm, 12.88 mS/cm) |
| Temperature Compensation | Linear, with selectable reference temperature (15–25 °C default) |
| Compliance | Designed per IEC 61010-1 for laboratory electrical safety |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | FE30 |
| Temperature Range | 0.0–100.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.3 °C |
| Conductivity Range | 0.00 µS/cm to 199.9 mS/cm |
| TDS Range | 0.00 mg/L to 199.9 g/L |
| Conductivity Accuracy | ±0.5% of reading |
| Display | LCD |
| Power Supply | External AC adapter |
| Operating Environment | 5–40 °C, 5–80% RH |
| Compliance | Designed for GLP-compliant workflows |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Model | FE30K |
| Form Factor | Benchtop |
| Conductivity Range | 0.1 μS/cm to 199.9 mS/cm |
| TDS Range | 0.1 mg/L to 199.9 g/L |
| Resistivity Range | 0.1 Ω·m to 19.99 MΩ·cm |
| Salinity Range | 0.00 to 19.99 psu |
| Temperature Range | 0.0 to 100.0 °C |
| Conductivity Accuracy | ±0.5% of reading |
| Temperature Accuracy | ±0.1 °C |
| Temperature Compensation | Linear, adjustable from 0.000 to 10.000 %/°C |
| reference temperatures | 20 °C and 25 °C |
| Calibration | Single-point with three pre-stored standard solutions (84 μS/cm, 1413 μS/cm, 12.88 mS/cm) |
| Display | Backlit LCD showing conductivity/TDS/salinity/resistivity, temperature, stability indicator, calibration status, and compensation settings |
| Power Supply | 100–240 V AC, 50–60 Hz |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Germany |
| Instrument Type | Portable |
| Parameter Capability | Multi-parameter (pH, mV, °C, Conductivity) |
| pH Range | –2.00 to 16.00 |
| mV Range | –2000 to +2000 mV |
| Temperature Range | 5 to 105 °C |
| pH Resolution | 0.01 / 0.1 |
| mV Resolution | 1 mV |
| Temperature Resolution | 0.1 °C |
| pH Accuracy | ±0.01 |
| mV Accuracy | ±1 mV |
| Temperature Accuracy | ±0.3 °C |
| Calibration Points | Up to 5-point (linear or segmented) |
| Predefined Buffers | 4 sets |
| Data Storage Capacity | 200 measurement records |
| Electrode Interfaces | BNC, Cinch, NTC 30 kΩ |
| Connectivity | RS232, USB |
| ATC Support | Yes (optional probe, P/N 12997876) |
| Display | 4.3-inch segment LCD |
| Housing Material | ABS |
| Dimensions (W × H × D) | 227 × 147 × 70 mm |
| Weight | 0.63 kg |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | FG2 |
| Instrument Type | Portable |
| pH Range | 0.00–14.00 |
| pH Resolution | 0.01 |
| pH Accuracy (relative) | ±0.01 |
| mV Range | −1999 to +1999 mV |
| mV Resolution | 1 mV |
| mV Accuracy (relative) | ±1 |
| Temperature Range | 0.0–100.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.5 °C |
| Calibration | Up to 3-point, with 4 predefined buffer sets |
| Data Storage | 30 measurements |
| Display | LCD |
| Power Supply | 4 × AAA 1.5 V batteries |
| IP Rating | IP54 |
| Operating Environment | 0–40 °C, 5–80 % RH |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | FG3 |
| Conductivity Range | 0.01 µS/cm to 199.9 mS/cm |
| TDS Range | 0.01 mg/L to 199.9 g/L |
| Salinity Range | 0.00–19.99 psu |
| Temperature Range | 0.0–100.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.3 °C |
| Conductivity Accuracy | ±0.5 % of reading |
| Calibration | Single-point automatic calibration |
| Display | LCD with simultaneous readout of conductivity/TDS/salinity, temperature, endpoint status, and system symbols |
| Protection Rating | IP54 |
| Power Supply | 4 × AAA 1.5 V batteries |
| Operating Environment | 0–40 °C, 5–80 % RH |
| Data Storage | 30 measurement records |
| Compensation | Linear temperature compensation with selectable reference temperature (e.g., 20 °C or 25 °C) |
| Auto-Endpoint Detection | Yes |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Instrument Type | Benchtop |
| Parameter Type | Single-Parameter (pH) |
| Measurement Range | −2.00 to 16.00 pH |
| Resolution | 0.01 pH |
| Accuracy | ±0.01 pH |
| Calibration Standards | Chinese JJG 119 / USP |
| Display | Large backlit LCD |
| Connectivity | RS232 and USB ports |
| Electrode Holder | Removable and stowable |
| Dimensions | 227 × 147 × 70 mm |
| Weight | 0.63 kg |
| Compliance | Designed for GLP-compliant workflows |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Model | FE30, FG3 |
| Conductivity Range | 0.00 µS/cm to 199.9 mS/cm |
| Resolution | 0.01 µS/cm to 0.1 mS/cm (auto-ranging) |
| Accuracy | ±0.5% of reading |
| Temperature Range | 0.0–100.0 °C |
| Temp. Resolution | 0.1 °C |
| Temp. Accuracy | ±0.3 °C |
| TDS Range | 0.0 mg/L to 199.9 g/L |
| Calibration | Single-point with three pre-programmed standards (84 µS/cm, 1413 µS/cm, 12.88 mS/cm) |
| Data Storage | 30 readings (FG3 only) |
| Ingress Protection | IP54 (FG3) |
| Power Supply | AC adapter (FE30) |
| Form Factor | Benchtop (FE30), Portable (FG3) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | FE38-Standard |
| Form Factor | Benchtop |
| Application Environment | Laboratory |
| Conductivity Range | 0.01 µS/cm to 500 mS/cm |
| TDS Range | 0.01 mg/L to 300 g/L |
| Salinity Range | 0.00–42 PSU |
| Temperature Range | −5 °C to 105 °C |
| Accuracy | ±0.5% of full scale |
| Minimum Conductivity Resolution | 0.01 µS/cm |
| Temperature Accuracy | ±0.3 °C |
| Temperature Compensation | Linear (0.00–10.00 %/°C), Reference Temp: 20 °C or 25 °C |
| Calibration | 1–3 point, with preset standards and manual cell constant entry |
| Data Storage | 200 measurement records + current calibration data |
| Interfaces | Mini-DIN electrode port, RS232, USB |
| Display | 4.3-inch segmented LCD |
| Dimensions | 227 × 147 × 70 mm |
| Weight | 0.63 kg |
| Housing Material | ABS |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | FE20 / FE30 |
| pH Range | 0.00–14.00 |
| Conductivity Range | 0.00 µS/cm–199.9 mS/cm |
| mV Range | −1999–+1999 mV |
| TDS Range | 0.0 mg/L–199.9 g/L |
| Temperature Range | 0.0–100.0 °C |
| Salinity Range | 0.00–19.99 psu |
| pH Resolution | 0.01 pH |
| Conductivity Resolution | 0.01 µS/cm–0.1 mS/cm (auto-ranging) |
| mV Resolution | 1 mV |
| TDS Resolution | 0.1 mg/L–0.1 g/L (auto-ranging) |
| Temperature Resolution | 0.1 °C |
| pH Accuracy | ±0.01 pH |
| Conductivity Accuracy | ±0.5 % of full scale |
| mV Accuracy | ±1 mV |
| TDS Accuracy | ±0.5 % of full scale |
| Temperature Accuracy | ±0.5 °C (±0.3 °C for built-in sensor) |
| Calibration | Up to 3-point pH with 4 predefined buffer sets |
| Power Supply | 220 V/50 Hz AC adapter or 9 V DC battery |
| Data Storage | 99 measurement records |
| Interface | RS232 |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | FE28-Standard |
| Instrument Type | Benchtop |
| Parameter Types | Dual (pH/mV) |
| pH Measurement Range | -2.00 to 16.00 pH |
| pH Resolution | 0.01 pH |
| pH Accuracy | ±0.01 pH |
| mV Range | -2000 to +2000 mV |
| mV Resolution | 1 mV |
| mV Accuracy | ±1 mV |
| Temperature Range | -5 °C to 105 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.3 °C |
| Temperature Compensation | Automatic (ATC) and Manual (MTC) |
| Calibration Standards | NIST-traceable buffers |
| Interface | RS232 and USB |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | FiveEasyPlus™ |
| Form Factor | Benchtop |
| Application Environment | Laboratory |
| Conductivity Range | 0.01 µS/cm to 500 mS/cm |
| Salinity Range | 0.00–42 psu |
| Temperature Range | 0–105 °C |
| Minimum Conductivity Resolution | 0.01 µS/cm |
| TDS Range | 0.01 mg/L to 300 g/L |
| Temperature Resolution/Accuracy | 0.1 °C / ±0.3 °C |
| Temperature Compensation | Linear, 0.00–10.00 %/°C, reference temperatures 20 °C and 25 °C |
| Data Storage | 200 measurement records + current calibration data |
| Interface | RS232 and USB |
| Electrode Compatibility | LE703 (included) |
| Compliance | Designed for GLP-compliant workflows with audit-ready calibration logging |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | FiveEasyPlus™ Benchtop |
| Conductivity Range | 0.01 µS/cm to 500 mS/cm |
| Resolution (Conductivity) | 0.01 µS/cm (auto-ranging) |
| Accuracy (Conductivity) | ±0.5% of reading |
| Temperature Range | 0–105 °C |
| Temperature Resolution/Accuracy | 0.1 °C / ±0.3 °C |
| Temperature Compensation | Linear, 0.00–10.00 %/°C |
| Reference Temp | 20 °C or 25 °C |
| TDS Range | 0.01 mg/L to 300 g/L |
| Salinity Range | 0.00–42 psu |
| Data Storage | 200 measurement records + current calibration data |
| Interfaces | RS232 and USB |
| Electrode Included | LE703 (for aqueous samples, medium-to-high conductivity) |
| Calibration Standards Supplied | 1413 µS/cm and 12.88 mS/cm pre-filled pouches |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | FiveEasyPlus™ |
| pH Range | −2.00 to 16.00 |
| pH Resolution/Accuracy | 0.01 / ±0.01 |
| Temperature Range | 0 to 105 °C |
| Temperature Resolution/Accuracy | 0.1 °C / ±0.3 °C |
| Temperature Compensation | Automatic (ATC) and Manual (MTC) |
| Data Storage | 200 measurement records + current calibration data |
| Buffer Sets | Predefined 4-point calibration sets |
| Interfaces | RS232 and USB |
| Electrode Compatibility | LE438, LE410, LE422, LE420, and other standard BNC-compatible pH electrodes |
| Display | Large backlit LCD with intuitive icon-based interface |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | FE28 |
| Instrument Type | Benchtop |
| Parameter Types | pH and mV |
| Measurement Range | –2.00 to 16.00 pH |
| Resolution | 0.01 pH / 0.1 mV |
| Accuracy | ±0.01 pH |
| Calibration | Manual 1–3 point calibration with standard buffers (e.g., pH 4.01, 7.00, 10.01) |
| Connectivity | RS232 and USB interfaces |
| Display | Large backlit LCD with icon-based status indicators |
| Electrode Holder | Integrated retractable holder |
| Compliance | Designed in accordance with IEC 61010-1 for laboratory electrical safety |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | FiveEasyPlus™ pH/mV |
| Form Factor | Benchtop |
| Application Environment | Laboratory |
| pH Measurement Range | -2.00 to 16.00 |
| mV Measurement Range | ±2000 mV |
| Conductivity Range | -2.00 to 16.00 mS/cm (as configurable parameter) |
| Salinity Range | 0.00–42.00 psu |
| Temperature Range | 0.0 to 105.0 °C |
| Temperature Resolution/Accuracy | 0.1 °C / ±0.3 °C |
| pH Resolution/Accuracy | 0.01 / ±0.01 |
| Data Storage Capacity | 200 measurement records + current calibration data |
| Calibration Points | Up to 5-point pH calibration |
| Temperature Compensation | Automatic (ATC) and Manual (MTC) |
| Interface | RS232 and USB |
| Predefined Buffer Sets | 4 standard groups (e.g., DIN, NIST, US, TECH) |
| Electrode Compatibility | Universal BNC + reference input |
| Audible Signal | Yes |
| Display | High-contrast monochrome LCD with icon-based status indicators |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | F2 |
| Instrument Type | Portable |
| IP Rating | IP67 |
| pH Range | 0.00–14.00 |
| pH Resolution | 0.01 |
| pH Accuracy | ±0.01 |
| mV Range | −1999 to +1999 mV |
| mV Resolution | 1 mV |
| mV Accuracy | ±1 mV |
| Temperature Range | 0 °C to 100 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.5 °C |
| Calibration | Up to 3-point with 4 preset buffer sets |
| Endpoint Detection | Auto/manual with audible and visual indication |
| Temperature Compensation | Automatic/manual |
| Electrode Interfaces | BNC, Cinch, NTC 30 kΩ |
| Data Storage | 200 measurement records |
| Display | 3.1-inch segmented LCD |
| Power Supply | 4 × AAA batteries (>200 h battery life) |
| Housing Material | ABS |
| Dimensions | 188 × 77 × 33 mm |
| Weight | 0.26 kg |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | FiveGo F2 |
| Instrument Type | Portable |
| Parameter Type | Single-parameter (pH/mV/°C) |
| pH Range | 0.00–14.00 |
| pH Resolution | 0.01 |
| pH Accuracy | ±0.01 |
| mV Range | −1999 to +1999 mV |
| Temperature Range | 0.0–100.0 °C |
| Temperature Compensation | Automatic or Manual |
| Calibration | Up to 3-point calibration with 4 built-in buffer sets |
| Data Storage | 200 measurement records |
| Protection Rating | IP67 |
| Power Supply | Standard AA batteries |
| Compliance | International buffer standards (DIN, NIST, JIS, etc.) |