Electrochemical Instruments
Filter
Showing 1141–1170 of 1703 results
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | T9 |
| Titration Type | Universal Potentiometric Titrator |
| Measurement Range | ±2000 mV / −26.0 to +40.0 pH |
| Meter Accuracy | 0.01% |
| Meter Resolution | 0.1 mV / 0.001 pH |
| Titration Precision | 0.2 mV / 0.003 pH |
| Integrated Burettes | 1 internal + 7 external |
| Parallel Titration Capability | Yes (up to 30 tasks, max 8 concurrent) |
| GLP Compliance | Yes |
| Software Logic | IF…THEN conditional method control |
| Supported Techniques | Acid-base, redox, complexometric, non-aqueous, photometric, coulometric & volumetric Karl Fischer titration |
| Auto-sampler Compatibility | InMotion™, Rondolino, Stromboli |
| Sensor Interfaces | Up to 3 sensor boards, plug-and-play sensors |
| Language Support | English, German, French, Spanish, Italian, Russian, Polish, Korean, Portuguese, Chinese |
| User Profiles | Password-protected, role-based access control |
| Connectivity | USB (printer, barcode scanner), RS-232 |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | T9 |
| Measurement Range | −2000 to +2000 mV |
| Meter Accuracy | ±0.2 mV |
| Meter Resolution | 0.01 mV |
| Titration Precision | ±0.3 µL |
| Titrant Drive Units | 1 internal + 7 external |
| Parallel Titration Capacity | up to 30 tasks, 8 concurrent |
| IF-THEN Logic Support | Yes |
| GLP Compliance | Yes |
| Language Support | English, German, French, Spanish, Italian, Russian, Polish, Korean, Portuguese, Chinese |
| Interface | USB (printer, barcode reader), RS-232 |
| SmartSample Integration | Yes |
| Auto Electrode & Burette Recognition | Yes |
| InMotion™ Auto-sampler Compatible | Yes |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | DP70 / DP90 |
| Measurement Range | ±2000 mV |
| Meter Accuracy | ±0.50% of reading |
| Meter Resolution | 0.1 mV |
| Titration Stability | ±0.2 mV over 3 h |
| Instrument Type | Universal Automatic Potentiometric Titrator |
| Compliance | Designed for ASTM E2087, ISO 8655-6, USP <541>, and GLP/GMP environments |
| Brand | 合肥科晶 |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestically Manufactured |
| Model | MgAl2O4 |
| Pricing | Upon Request |
| Crystal Structure | Cubic, Lattice Constant a = 8.085 Å |
| Growth Method | Czochralski (CZ) |
| Melting Point | 2130 °C |
| Density | 3.64 g/cm³ |
| Mohs Hardness | 8 |
| Thermal Expansion Coefficient | 7.45 × 10⁻⁶ /°C |
| Acoustic Velocity | 6500 m/s |
| [100] Shear Wave Propagation Loss (9 GHz) | 6.5 dB/µs |
| Color & Appearance | White, Transparent |
| Standard Orientations | <100>, <110>, <111> |
| Orientation Tolerance | ±0.5° |
| Standard Dimensions | 2" dia × 0.5 mm, 10 × 10 × 0.5 mm, 10 × 5 × 0.5 mm |
| Polishing | Single-side or double-side polished |
| Surface Roughness (Ra) | <5 Å |
| Packaging | Class 1000 cleanroom environment |
| Brand | Hefei Kejing |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | MgO Crystal Substrate |
| Price | Upon Request |
| Crystal Structure | Cubic |
| Lattice Constant | a = 4.216 Å |
| Growth Method | Arc Melting |
| Melting Point | 2850 °C |
| Density | 3.58 g/cm³ |
| Mohs Hardness | 5.5 |
| Thermal Expansion Coefficient | 12.8 × 10⁻⁶ /°C |
| Dielectric Constant | 9.8 |
| Optical Transmittance | >90% @ 200–400 nm, >98% @ 500–1000 nm |
| Cleavage Plane | <100> |
| Orientations Available | <100>, <110>, <111> |
| Orientation Tolerance | ±0.5° |
| Standard Dimensions | Ø2" × 0.5 mm, 10 × 10 × 0.5 mm, 10 × 5 × 0.5 mm |
| Surface Finish | Single- or Double-Polished |
| Surface Roughness | Ra <15 Å for <111>, Ra <5 Å for <100> and <110> |
| Packaging | Class 1000 Cleanroom, Class 100 Clean Bag or Individual Wafer Cassette |
| Brand | Narishige |
|---|---|
| Origin | Japan |
| Model | MHW-3 |
| Drive Mechanism | Water-Hydraulic |
| Motion Resolution (Fine) | 0.2 µm (min. scale) |
| Coarse Travel Range (X/Y/Z) | 30 mm each |
| Fine Travel per Full Knob Rotation | 50 µm |
| Coarse Travel per Full Knob Rotation | ~4 mm |
| Control Unit Dimensions | 115 × 115 × 132 mm, 1.6 kg |
| Drive Unit Dimensions | 155 × 155 × 100 mm, 900 g |
| Hydraulic Tubing Length | 900 mm |
| Joint Type | Spherical Ball Joint (B-9 Standard) |
| Electrode Holder | H-12 Type |
| Included Accessories | Hex Key Wrench, Dual Adapter, Isolation Mounting Platform |
| Brand | MinTech |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | MT-CNE200 |
| Price | Upon Request |
| Functionality | Electrode Fabrication & Thermal Annealing |
| R<sub>G</sub> Ratio | As low as 1.1 |
| Template Material | Fused Silica Quartz |
| Tip Diameter Range | 10 nm – 50 µm (Optimized for 200–500 nm) |
| Electrode Types | Carbon Nanoelectrodes, Carbon Micronelectrodes, Carbon Nanotip Electrodes, Derivative Electrodes (Metallic Nanoelectrodes, Metal Oxide Nanoelectrodes) |
| Dimensions | 480 × 340 × 320 mm |
| Weight | ~20 kg |
| Brand | MinTech |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Manufacturer |
| Regional Category | Domestic (China) |
| Model | MT-PSAM/IMMS100 |
| Pricing | Upon Request |
| Brand | MIPS |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MIPS |
| Pricing | Available Upon Request |
| Brand | MITSUBISHI CHEMICAL |
|---|---|
| Origin | Japan |
| Model | CA-200 |
| Measurement Principle | Coulometric Karl Fischer Titration |
| Detection Range | 10 µg – 100 mg H₂O |
| Accuracy | CV ≤ 0.3% for samples ≥ 1 mg H₂O (n = 10) |
| Electrolysis Current | 430 mA |
| Average Titration Speed | 2.2 mg H₂O/min (36 µg H₂O/sec) |
| Display | 5.7-inch color LCD |
| Data Storage | 20 user-defined methods × 50 sub-files each |
| Interface | RS-232C (optional), USB storage port, analytical balance input |
| Power Supply | AC 100–120 V / 230–240 V, 50/60 Hz |
| Host Dimensions & Weight | 220 × 350 × 360 mm, ~5 kg |
| Stirrer Dimensions & Weight | 120 × 180 × 148 mm, ~1 kg |
| VA-200 Sample Heater | Temp. Range 70–300 °C, N₂ carrier gas flow 0.1–0.5 L/min, max. sample mass 10 g, weight ~5.5 kg |
| Brand | Mitsubishi Chemical |
|---|---|
| Origin | Japan |
| Model | GT-200 |
| Measurement Range | 0–14 pH, −2000 to +2000 mV, 0–20 µA |
| Titrant Dispensing Accuracy | ±0.01 mL (20 mL burette) |
| Resolution | 0.002 mL |
| Titration Resolution | 1/10000 |
| Display | 5.7″ color LCD |
| Operating Temperature | 5–40 °C |
| Humidity | ≤85% RH (non-condensing) |
| Power Supply | 100–240 V AC, 100 VA |
| Dimensions (main unit) | 175 × 408 × 176 mm (W×D×H) |
| Weight | 4 kg |
| GLP Compliance | Full audit trail for calibration, electrode validation, titrant standardization, and user access logs |
| Brand | MITSUBISHI CHEMICAL |
|---|---|
| Origin | Japan |
| Model | GT-310 |
| Display | 8.4-inch color touchscreen |
| Channels | up to 4 simultaneous potentiometric and/or Karl Fischer titration channels |
| Modularity | supports solvent dispensers, autosamplers, analytical balances, and printers |
| Compliance | Designed for GLP/GMP environments |
| Pricing | Available upon request |
| Brand | MITSUBISHI CHEMICAL |
|---|---|
| Origin | Japan |
| Model | GT-310 |
| Instrument Type | General-purpose Potentiometric Titrator |
| pH Range | 0–14 |
| mV Range | –2000 to +2000 mV |
| Meter Accuracy | ±0.2% of full scale |
| pH Resolution | 0.001 pH unit |
| Titration Endpoint Precision | ±0.3 mV |
| Maximum Simultaneous Modules | 4 titration units (potentiometric and/or Karl Fischer) |
| Endpoint Detection Modes | First Derivative (Inflection Point), Fixed Potential, Pre-/Post-Intersection, V-Crosspoint, and Second Derivative |
| Brand | Mitsubishi Chemical |
|---|---|
| Origin | Japan |
| Model | MCP-HT800 |
| Portability | Portable |
| Impedance Measurement Range | 10⁴ Ω to 10²⁰ Ω |
| Accuracy | ±2% (10⁴–10⁹ Ω), ±3% (up to 10²⁰ Ω) |
| Test Voltage Range | 1 V to 10 V (programmable, DC or low-frequency AC) |
| Compliance | CE, JIS C 1302, IEC 60068-2 (environmental robustness for lab/field use) |
| Brand | Mitsubishi Chemical |
|---|---|
| Origin | Japan |
| Model | MCP-T370 |
| Portability | Portable |
| Measurement Principle | Four-terminal (Kelvin) DC resistance / low-impedance ohmic measurement |
| Probe Interface | 4-pin coaxial connector |
| Data Output | RS-232C |
| Dimensions | 100 mm (W) × 230 mm (D) × 45 mm (H) |
| Weight | 500 g |
| Power Supply | DC 6.5 V, 350 mA |
| Display | LCD |
| Brand | NARISHIGE |
|---|---|
| Origin | Japan |
| Model | MM-3 |
| Gross Weight | 790 g |
| Dimensions (W×D×H) | 105 × 70 × 145 mm |
| Coarse Movement Range (X/Y/Z) | 30 / 20 / 35 mm |
| Fine Movement Range (X-axis only) | 7 mm |
| Fine Adjustment Resolution | 10 µm per click (250 µm per full rotation) |
| Electrode Holder | Compatible with H-1 holder and standard 1.2–1.5 mm diameter electrode shafts |
| Ergonomic Design | Dual-handled X/Z control, rack-and-pinion coarse drive, gravity-compensated tension adjustment |
| Brand | NARISHIGE |
|---|---|
| Origin | Japan |
| Model | MMN-33 |
| Axis Configuration | Single-axis coarse/fine adjustment (X-Z dual-hand control) |
| Coarse Travel Range | X 40 mm, Y 20 mm, Z 35 mm |
| Fine Travel Range | X 7 mm |
| Minimum Step Size | 10 µm |
| Maximum Rotation Speed | 250 µm/rev |
| Electrode Holder Compatibility | H-1 electrode holder included |
| Dimensions (W×D×H) | 105 × 70 × 155 mm |
| Weight | 880 g |
| Brand | Narishige |
|---|---|
| Origin | Japan |
| Model | MMO-220A |
| Drive Principle | Oil-Hydraulic |
| Axis Configuration | Single-Axis (Z-axis fine adjustment) |
| Fine Adjustment Range | 10 mm |
| Minimum Step Resolution | 1 µm |
| Coarse Rotation per Full Turn | 250 µm |
| Control Unit Dimensions (W×D×H) | 65 × 88 × 93 mm, 630 g |
| Actuator Unit Dimensions (W×D×H) | 52 × 20 × 35 mm, 38 g |
| Hydraulic Tubing Length | 0.9 m |
| Compatibility | Mounts to standard 3-axis micromanipulators (e.g., MO-202, MN-4, or equivalent ball-joint platforms) |
| Operating Principle | Continuous hydrostatic pressure transmission via incompressible silicone oil |
| Brand | Hefei Kejing |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Origin Classification | Domestic |
| Model | Mo Foil |
| Price Range | USD 0.15–1,500 (FOB) |
| Thickness | 0.01–1 mm |
| Packaging | Vacuum-sealed in Class 100 cleanroom bags, stored and shipped from Class 1000 cleanroom environment |
| Brand | Narishige |
|---|---|
| Origin | Japan |
| Model | MO-10 |
| Actuation Principle | Oil-hydraulic displacement amplification |
| Control Mechanism | Drum-type rotary actuator |
| Total Travel Range | 10 mm |
| Fine Adjustment per Full Knob Rotation | 500 µm |
| Minimum Graduation | 2 µm |
| Hydraulic Tubing Length | 1.5 m |
| Control Unit Dimensions (W×D×H) | 65 × 88 × 93 mm |
| Control Unit Weight | 630 g |
| Drive Unit Dimensions (W×D×H) | 30 × 20 × 125 mm |
| Drive Unit Weight | 50 g |
| Mounting Compatibility | Standard 3-axis manual micromanipulator rails (e.g., Narishige MMO-2, MN-4, or equivalent) |
| Brand | Teledyne Princeton Instruments |
|---|---|
| Origin | UK |
| Model | Modulab XM PhotoEchem |
| Instrument Type | Electrochemical Workstation |
| Current Range | ±300 mA |
| Current Accuracy | 0.1% reading + 0.05% range + 30 fA |
| Potential Accuracy | 0.1% reading + 0.05% range + 100 µV |
| Potentiostatic Range | ±8 V |
| AC Impedance Frequency Range | 10 µHz – 1 MHz |
| Brand | Narishige |
|---|---|
| Origin | Japan |
| Model | MP-2 |
| Motion Range (Coarse) | X 60 mm, Z 50 mm |
| Motion Range (Fine) | X 4 mm, Z 4 mm, Y 40 mm |
| Fine Adjustment Resolution | 10 µm per click (X/Z/Y) |
| Coarse Knob Travel per Full Rotation | X/Z 250 µm, Y 500 µm |
| Pivot & Tilt Functionality | Integrated |
| Electrode Holder Included | H-1 |
| Dimensions (W×D×H) | 150 × 130 × 210 mm |
| Weight | 4.8 kg |
| Brand | MTI Corporation (formerly Hefei Kejing) |
|---|---|
| Origin | Anhui, China |
| Model | MSK-PN110-S |
| Drive Gas Pressure Range | 0.7–1.2 MPa (recommended: 0.9 MPa) |
| Stroke Distance | 20 mm |
| Gas Consumption per Cycle | 490 mL |
| Standard Die Set | 20-series (2016, 2025, 2032) |
| Optional Dies | 24-series, Disassembly Dies |
| Die Material | Hardened Tool Steel |
| Housing Material | Heavy-Duty Steel |
| Dimensions (L×W×H) | 290 × 260 × 350 mm |
| Weight | ~28 kg |
| Warranty | 12 months, lifetime technical support |
| Compliance | Designed for inert-atmosphere glovebox integration (O₂/H₂O < 1 ppm), compatible with ISO 14644-1 Class 5 cleanroom practices when installed in controlled enclosures |
| Brand | PalmSens |
|---|---|
| Origin | Netherlands |
| Model | MultiPalmSens4 |
| Channel Count | 4–10 configurable channels |
| Current Range | ±30 mA |
| Current Accuracy | ≤ 0.1% of full scale |
| Potential Accuracy | 0.01% of full scale |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 10 μHz to 1 MHz |
| ADC Resolution | 18-bit (76.3 µV potential resolution, 5 fA current resolution at 100 pA range) |
| Data Acquisition Rate | up to 150,000 points/s |
| Onboard Memory per Channel | 8 GB |
| Compliance | CE, RoHS, ISO/IEC 17025-compatible operation environment |
| Brand | MYRON L |
|---|---|
| Origin | USA |
| Model | Ultrameter 6P |
| Instrument Type | Portable |
| Parameter Count | 6 |
| Measurement Accuracy | ±0.01 pH |
| pH Range | 0–14 |
| pH Resolution | 0.01 |
| pH Accuracy | ±0.01 pH |
| Calibration Solution | pH 7 buffer |
| Conductivity Range | Auto-ranging 0–9999 µS/cm, 10–200 mS/cm |
| TDS Range | 0–9999 ppm, 10–200 ppt |
| Resistivity Range | 10 kΩ·cm – 30 MΩ·cm |
| ORP Range | ±999 mV |
| Temperature Range | 0–71 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.1 °C |
| Auto Temperature Compensation | Yes (0–71 °C) |
| IP Rating | IP67 (NEMA 6) |
| Data Storage | 20 points with timestamp |
| Enclosure | Fully sealed, buoyant, submersible to 1 m |
| Brand | MYRONL |
|---|---|
| Origin | USA |
| Model | 532T1 |
| Measurement Principle | Two-electrode conductivity cell with linear TDS conversion (NaCl equivalence) |
| TDS Range | 0–50 / 0–500 / 0–5000 ppm (auto-ranging) |
| Resolution | 1 ppm (0–50 ppm), 10 ppm (0–500 ppm), 100 ppm (0–5000 ppm) |
| Accuracy | ±2% of full scale |
| Temperature Compensation | Automatic, 10–71 °C |
| pH Range | 0.0–14.0 (with replaceable pH electrode) |
| Power | 9 V alkaline battery (approx. 2,000 measurements/year) |
| Electrode Type | Maintenance-free graphite conductivity cell |
| Enclosure | IP65-rated rugged ABS housing |
| Compliance | Designed for field and lab use per ASTM D1125 and ISO 7888 guidelines for conductivity/TDS estimation |
| Brand | MyronL |
|---|---|
| Origin | USA |
| Model | EP/512M5/EP10 |
| Conductivity Ranges | 0–0.5 µS, 0–5 µS, 0–50 µS, 0–500 µS, 0–5000 µS, 0–10 mS, 0–100 mS, 0–1000 mS, 0–10,000 µS |
| Resistivity Range | 2–30 MΩ |
| Accuracy | ±2% of full scale (all ranges) |
| Automatic Temperature Compensation | 10–71 °C |
| Power | 9 V alkaline battery (≈2000 measurements/year) |
| Electrode Type | Maintenance-free conductive cell |
| Compliance | Designed for field and lab use in accordance with ASTM D1125 and ISO 7888 principles |
| Brand | MYRONL |
|---|---|
| Origin | USA |
| Model | Ultrameter 4P |
| Portability | Portable |
| Conductivity Range | 0–200 mS/cm |
| TDS Range | 0–9999 ppm |
| Resistivity Range | 10 kΩ·cm – 30 MΩ·cm |
| Salinity Range | Not applicable (dedicated conductivity/TDS/resistivity/temperature model) |
| Temperature Range | 0–71 °C |
| Accuracy | ±1% of reading |
| Minimum Conductivity Resolution | 0.01 µS/cm |
| Enclosure Rating | IP67 (NEMA 6) |
| Data Storage | 20 points with timestamp |
| Auto-Temperature Compensation | Yes (0–71 °C) |
| Electrode Design | Integrated, field-replaceable dual-cell conductivity sensor with built-in temperature probe |
| Brand | Narishige |
|---|---|
| Origin | Japan |
| Model | M-3333 |
| Dimensions (W×D×H) | 126 × 43 × 145 mm |
| Weight | 340 g |
| Coarse Motion Range (X/Y/Z) | 40 / 12 / 30 mm |
| Fine Motion Range (X) | 7 mm |
| Minimum Step Size | 10 µm |
| Maximum Step Size | 250 µm |
| Compatible Electrode Holder | H-1 |
| Drive Mechanism | X-4 Rotational X-Block |
| Construction | Compact, Low-Profile Monoblock Design |