| Brand | BQC |
|---|---|
| Origin | Spain |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | BRS |
| Pricing | Available Upon Request |
| Brand | BRAND® |
|---|---|
| Origin | Germany |
| Model | 4760161 |
| Measurement Range | 0.2–10 mL |
| Meter Accuracy | ±0.1% |
| Meter Resolution | 0.001 mL |
| Dispensing Accuracy | ≤±0.2% |
| Dispensing Resolution | 0.001 mL |
| Compliance | DIN EN ISO 385 (Class A volumetric accuracy) |
| Key | Brand: Caikon |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic Instrument |
| Model | CKJF-4G |
| Price Range | USD 2,650 – 2,950 |
| Compliance | GB/T 4334–2020, ASTM A262–2015 |
| Heating Capacity | 2000 W total (4 × 500 W independent stations) |
| Max Operating Temperature | 400 °C |
| Simultaneous Samples | 4 |
| Control System | PLC + PID with touchscreen HMI |
| Cooling | Integrated reflux condensation system (no external water source required) |
| Safety Features | Dry-run alarm, overtemperature cutoff, power-interruption resume function |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | ScienceLine B 2220+ |
| Electrode Type | Single-Reference Electrode |
| Body Material | Glass |
| Reference System | Ag/AgCl (3 mol/L KCl) |
| Temperature Range | −5 °C to +100 °C |
| pH Range | 0–14 |
| Junction Type | Double-Liquid-Junction |
| Sensing Element | Platinum |
| Connection | L 1 N Cable |
| Compliance | ASTM D1129, ISO 7888, USP <798>, GLP-ready configuration |
| Origin | Sichuan, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | JP-2E |
| Pricing | Upon Request |
| Polarographic Sensitivity | <5×10⁻⁸ mol/L (Cd²⁺, Linear Sweep Voltammetry) |
| Polarographic Peak Resolution | <32 mV |
| Anti-Interference Capability (Pre-reduced Species) | >20,000:1 |
| Repeatability Error | <0.4% |
| Current Range | 15 nA–400 µA F.S., 23 programmable decades |
| Polarization Potential Range | ±4000 mV, minimum step: 2 mV |
| Scan Rate | 50–1600 mV/s |
| Scan Amplitude | 50–1600 mV |
| Scan Period | 2–22 s |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Weight | 15 kg |
| Interface | USB 2.0 for PC connectivity |
| Software Modes | Linear Sweep Voltammetry, Stripping Voltammetry (Anodic/Cathodic), Cyclic Voltammetry (Anodic/Cathodic), First/Second Derivative Voltammetry |
| Quantitative Methods | Calibration Curve (Linear & Quadratic Regression), Standard Addition, Standard Comparison |
| Electrode Compatibility | Glassy Carbon Electrode (GCE) interface with full Dropping Mercury Electrode (DME) functional equivalence |
| Data Export | Native CSV/Excel-compatible output, curve annotation, overlay, and statistical post-processing |
| Brand | Chengyi (scchengyi) |
|---|---|
| Origin | Sichuan, China |
| Model | CZD-1 |
| Measurement Range | pH 0.00–14.00 |
| Accuracy | ±0.06 pH (pH measurement), ±0.2% (volumetric repeatability) |
| Resolution | 0.01 pH / 1 mV |
| Stability | ±0.01 pH per 3 h |
| Endpoint Setting Range | 0.00–14.00 pH or ±1400 mV |
| Control Sensitivity | ±0.1 pH / ±5 mV |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Power Consumption | 10 W |
| Net Weight | 5 kg |
| Environmental Operating Conditions | 5–40 °C, ≤85% RH |
| Brand | Chengyi |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JP-2C |
| Price Range | USD 2,800 – 4,300 (FOB) |
| Polarographic Sensitivity | <5×10⁻⁸ mol/L (Cd²⁺, Linear Sweep Polarography) |
| Resolution of Polarographic Peaks | <32 mV |
| Tolerance to Pre-reduced Interferents | >10,000:1 |
| Repeatability Error | <0.5% |
| Range Switching Error | <0.5% |
| Current Range | 15 nA – 400 µA F.S., 23 programmable decades |
| Polarization Potential Range | ±3904 mV, minimum step 32 mV |
| Scan Rate | 250 mV/s |
| Scan Amplitude | 500 mV |
| Scan Period | 1 s – 1000 s |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Weight | 15 kg |
| Display | 19″ LED LCD (1366×768), USB mouse & dual USB host ports (for firmware update & data export) |
| Parameter Storage | Up to 5 user-defined methods |
| Onboard Quantification | Standard Comparison Method supported |
| ADC/DAC Resolution | 12-bit (1/4096 precision) |
| Embedded Platform | ARM-based real-time control system |
| Compliance | Designed for GLP-aligned laboratory workflows |
| Brand | Chengyi |
|---|---|
| Origin | Sichuan, China |
| Model | JP-2D |
| Polarographic Current Range | 15 nA–400 µA (F.S., 23 programmable ranges) |
| Polarization Potential Range | ±3904 mV (32 mV resolution) |
| Scan Rate | 50–1000 mV/s |
| Scan Amplitude | 50–1000 mV |
| Scan Period | 1–1000 s |
| Sensitivity | <5×10⁻⁸ mol/L (Cd²⁺, linear sweep polarography) |
| Resolution | <32 mV |
| Anti-Interference Ratio (pre-reduction substances) | >10⁴:1 |
| Repeatability Error | <0.3% |
| Range-Switching Error | <0.3% |
| ADC Precision | 18-bit |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Power Consumption | ~30 W |
| Weight | 15 kg |
| Interface | USB 2.0 |
| Integrated Control Unit | 19.5″ all-in-one industrial PC (optional external Windows PC support) |
| Software | JP-2D Polarographic Analysis Suite (Windows 7/8/10, 32/64-bit |
| Brand | Chengyi |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JP-2E |
| Price Range | USD 4,200 – 7,000 |
| Sensitivity | <5×10⁻⁸ mol/L (Cd²⁺, linear sweep polarography) |
| Resolution | <32 mV |
| Anti-interference Ratio (pre-reduction substances) | >20,000:1 |
| Repeatability Error | <0.4% |
| Range Switching Error | <0.4% |
| Current Range | 15 nA – 400 µA F.S., 23 programmable ranges |
| Polarization Potential | ±4000 mV, min. step 2 mV |
| Scan Rate | 50–1000 mV/s |
| Scan Amplitude | 50–1000 mV |
| Cycle Time | 2–22 s |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Weight | ~15 kg |
| Brand | Chengyi |
|---|---|
| Model | JP-303E |
| Origin | Sichuan, China |
| Sensitivity | <2×10⁻⁸ mol/L (Cd²⁺, linear sweep polarography) |
| Peak Resolution | <30 mV |
| Antioxidant Tolerance | >20,000:1 |
| Repeatability Error | <0.1% |
| Range Switching Error | <0.2% (≥1.5×10³ nA), <0.4% (≤1.0×10³ nA) |
| Potential Resolution | 2 mV |
| Current Resolution | 0.03% of full scale (conventional, 1st & 2nd derivative modes) |
| Current Range | (6–4×10⁵) nA, 25 programmable ranges |
| Polarization Potential Range | ±4094 mV, min. step 2 mV |
| Scan Rate | 50–1000 mV/s, continuously adjustable |
| Scan Amplitude | 0–1600 mV, min. step 2 mV |
| Scan Duration | 1–1000 s |
| Power Supply | AC 220 V, 50/60 Hz |
| Brand | Chuandi |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | pHB-09B |
| Price | Upon Request |
| Measurement Range | pH 0–14 (0.01 resolution, ±0.02 pH ±1 digit) |
| ORP | ±1999 mV (0.1 mV resolution) |
| pX | Ion-selective electrode standard curve method |
| Temperature | 0–100 °C (operational limit: 60 °C |
| Input Impedance | ≥1 × 10¹² Ω |
| Power Supply | 3.7 V rechargeable Li-ion battery |
| Dimensions | 13.5 × 7 × 2.5 cm |
| Weight | 130 g |
| Brand | COMECAUSE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | IN-D1 |
| Instrument Type | General-purpose Potentiometric Titrator |
| Application Scope | Universal |
| Potential Range | −2000 to +2000 mV |
| Potential Resolution | 0.1 mV |
| Titration Precision | ±5 µL (for 10 mL burette) |
| Potential Resolution (display) | 0.1 mV |
| pH Range | 0–14 |
| pH Resolution | 0.01 |
| pH Accuracy | ±0.01 |
| Temperature Range | −5 to 105 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.2 °C |
| Repeatability | ≤0.2% |
| Maximum Error | ≤±1.5% |
| Burette Options | 10 mL (±5 µL), 20 mL (±10 µL) |
| Operating System | Android 10 |
| Display | 7-inch capacitive touchscreen |
| Data Storage Capacity | 100,000 records |
| Connectivity | USB, Wi-Fi, Ethernet |
| Dimensions | 310 × 226 × 233 mm |
| Weight | 3.7 kg |
| Brand | COMECAUSE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | General-Purpose Automatic Potentiometric Titrator |
| Application Scope | Universal |
| Potential Measurement Range | −2000 to +2000 mV |
| Potential Resolution | 0.1 mV |
| Titration Precision | ±5 µL (for 10 mL burette) |
| Potential Display Resolution | 0.1 mV |
| Compliance | JJG 814–2015 Class 0.05 (Max. Indication Error: ±1.5% |
| pH Range | 0–14 |
| pH Resolution | 0.01 |
| pH Accuracy | ±0.01 |
| Conductivity Range | 0.00 µS/cm–2000 mS/cm |
| Temperature Range | −5 to 105 °C |
| Resolution | 0.1 °C |
| Accuracy | ±0.2 °C |
| Operating System | Android 10 |
| Display | 7-inch capacitive touchscreen |
| Data Storage | ≥100,000 records |
| Connectivity | USB, Wi-Fi, Ethernet |
| Dimensions | 310 × 226 × 233 mm |
| Weight | 3.7 kg |
| Brand | COMECAUSE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | IN-D3 |
| Instrument Type | General-Purpose Automatic Potentiometric Titrator |
| Application Scope | Universal Laboratory Use |
| Potential Range | −2000 to +2000 mV |
| Potential Resolution | 0.1 mV |
| Titration Accuracy | ±5 µL (for 10 mL burette) |
| Potential Basic Error | ±0.25 ‰/FS |
| pH Range | 0–14 |
| pH Resolution | 0.01 |
| pH Accuracy | ±0.01 |
| Temperature Range | −5 to 105 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.2 °C |
| Data Storage Capacity | 100,000 records |
| Operating System | Android 10 |
| Display | 7-inch capacitive touchscreen |
| Connectivity | USB, Wi-Fi, Ethernet |
| Dimensions | 310 × 226 × 233 mm |
| Weight | 3.7 kg |
| Brand | COMECAUSE |
|---|---|
| Model | IN-D4 |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | General-Purpose Automatic Potentiometric Titrator |
| Application Scope | Universal |
| Potential Measurement Range | −2000 to +2000 mV |
| Potential Resolution | 0.1 mV |
| Potential Accuracy | ±0.25 ‰ of full scale |
| Potential Stability | ±0.3 mV / 3 h |
| Titration Precision | ±5 µL (for 10 mL burette) |
| Titration Resolution | 0.1 mV |
| pH Range | 0–14 |
| pH Resolution | 0.01 |
| pH Accuracy | ±0.01 |
| Conductivity Range | 0.00 µS/cm – 2000 mS/cm |
| Conductivity Accuracy | ±1.0 % FS |
| Temperature Range | −5 °C to +105 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.2 °C |
| Display | 7-inch Android 10 touchscreen |
| Data Storage | 100,000 records |
| Connectivity | USB / Wi-Fi / Ethernet |
| Dimensions | 310 × 226 × 233 mm |
| Weight | 3.7 kg |
| Brand | DC-Energies |
|---|---|
| Model | DC 780 |
| Origin | Hubei, China |
| Manufacturer | Wuhan DC-Energies New Energy Co., Ltd. |
| Type | Benchtop Electrolyzer Test System |
| H₂/O₂ Flow Measurement Accuracy | ±1% FS |
| Operating Pressure Range | 1–10 bar (adjustable via high-precision back-pressure regulator) |
| Temperature Control Stability | ±0.5 °C |
| Data Acquisition Rate | 5 Hz |
| Flow Control | Mass Flow Controllers (MFCs) for H₂ and O₂ |
| Software Compliance | Audit Trail Ready, User Access Levels, Test Parameter Locking (GLP/GMP-aligned architecture) |
| Brand | dc-energies |
|---|---|
| Model | DC TP-100 |
| Max. Hydraulic Force | 10 t (≈39.2 MPa on 5×5 cm² area) |
| Temperature Range | 50–350 °C (dual-zone heating) |
| Pressure Control | Digital Display, Four-Column Uniform Load Architecture |
| Compliance | Designed for PEM Fuel Cell MEA Fabrication per ASTM D7263, ISO 14687, and DOE Hydrogen Program Best Practices |
| Brand | DELEITE |
|---|---|
| Origin | Shanghai, China |
| Model | APT300 |
| Instrument Type | General-Purpose Potentiometric Titrator |
| Measurement Range | 0 to ±1999 mV, 0 to 14.00 pH |
| Accuracy | 0.1% F.S. (mV), ±0.01 pH |
| Control Precision | ±0.03 pH, ±3 mV |
| Input Impedance | >10¹² Ω |
| Operating Temperature | 5–40 °C |
| Relative Humidity | <85% RH |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Power Consumption | 20 W |
| Weight | 6 kg |
| Brand | Doctor Water |
|---|---|
| Origin | Hunan, China |
| Model | Dr-M1901 |
| Instrument Type | Portable |
| Parameter Type | Multi-parameter |
| pH Range | -2.00 to 20.00 pH |
| Display Resolution | 0.01 pH |
| Accuracy | ±0.01 pH |
| Calibration Points | 1–3 point |
| Temperature Range | 0–105 °C |
| Temp. Resolution | 0.1 °C |
| Temp. Accuracy | ±0.5 °C |
| Temperature Compensation | Automatic (0–100 °C) |
| Data Storage | 100 sets |
| Interface | USB, BNC, 3.5 mm audio jack |
| Power | 3 × AA batteries or DC 5 V adapter |
| Brand | DoctorWater |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Dr-W1000 |
| Instrument Type | Universal Automatic Potentiometric Titrator |
| Application Scope | General-purpose |
| Titration Accuracy | ≤0.01 mL |
| Titration Resolution | 0.01 mL |
| Burette Capacity Options | 10 mL / 25 mL |
| Maximum Error | ±0.05% |
| Liquid Handling | Medical-grade precision syringe pump |
| Mixing Method | Magnetic stirring |
| Display | 7-inch HD capacitive touchscreen |
| Interface Language | Default Chinese, optional English firmware |
| Data Storage | 10,000 test records with timestamp, operator ID, and location metadata |
| Built-in Thermal Printer | Yes |
| Operating Environment | 5–40 °C, RH <85% (non-condensing) |
| Power Supply | AC 100–240 V input, DC 24 V output |
| Brand | DoctorWater |
|---|---|
| Origin | Hunan, China |
| Model | Dr-M1902 |
| Portability | Portable |
| Conductivity Range | 0.01–20.00 µS/cm, 200.0 µS/cm, 2000 µS/cm, 20.00 mS/cm, 200.0 mS/cm |
| Temperature Range | 0–105°C (32–221°F) |
| Conductivity Accuracy | ±0.5% of full scale |
| Conductivity Resolution | 0.001 / 0.01 / 0.1 / 1 (auto-ranging) |
| Temperature Accuracy | ±0.5°C |
| Temperature Resolution | 0.1°C |
| Calibration Points | 1–3 points |
| Supported Standard Solutions | 10, 84, 1413 µS/cm |
| Temperature Compensation | Automatic or manual (linear: 0.0–10.0%/°C |
| Reference Temperature | 20°C or 25°C |
| Cell Constant Options | K = 0.1, 1.0, 10.0 cm⁻¹ |
| Data Storage | 100 measurement records |
| Interface | USB Type-A (data export & DC5V power input) |
| Power | 3× AA batteries (≈150 h runtime, backlight off) or external 5V adapter |
| Operating Temperature | 0–50°C |
| Connector | 6-pin DIN |
| Brand | EMCEE |
|---|---|
| Origin | USA |
| Model | 1152 |
| Portability | Portable |
| Application Environment | Laboratory & Field |
| Conductivity Range | 0–1999 pS/m |
| Temperature Range | 0 °C to 75 °C |
| Accuracy | ±2% of reading or ±1 pS/m (whichever is greater) |
| Resolution | 1 pS/m |
| Display | LCD |
| Calibration | Auto-calibration via field-adjustable circuitry |
| Power Supply | 3 × AA alkaline batteries |
| Enclosure | Anodized aluminum housing with corrosion-resistant coating |
| Probe | Removable stainless-steel electrode |
| Safety Certification | UL, CSA, LCIE certified for Class I, Division 1 hazardous locations |
| Compliance | ASTM D2624–22 (Standard Test Method for Electrical Conductivity of Aviation Turbine Fuels) |
| Brand | EMCEE |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Imported |
| Model | 1154 |
| Detection Parameter | Single (Conductivity) |
| Portability | Benchtop |
| Application Environment | Laboratory |
| Conductivity Range | 0–20,000 pS/m |
| Accuracy | ±½% of reading |
| Minimum Resolution | 0.01 pS/m |
| Brand | Eutech |
|---|---|
| Origin | USA |
| Model | ORPTEST10 |
| Instrument Type | Laboratory & Field-Portable ORP Meter |
| Measurement Range | −999 to +1000 mV |
| Resolution | 1 mV |
| Accuracy | ±2 mV |
| Calibration | Manual 1-point |
| Electrode Type | Replaceable Double-Junction Ag/AgCl |
| Power Supply | 4 × A76/LR44 batteries |
| Battery Life | >500 hours |
| Auto-Off | 8.5 min idle |
| Operating Temperature | 5–45 °C |
| IP Rating | IP67 |
| Display | Dual-line LCD (2.1 × 2.7 cm) |
| Dimensions | 16.5 × 3.8 cm |
| Weight | 90 g |
| Data Hold & Low-Battery Indication | Yes |
| Temperature Compensation | None (ORP-only measurement) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Singapore |
| Manufacturer | Eutech Instruments (a Thermo Fisher Scientific brand) |
| Type | Portable Multi-parameter Electrochemical Analyzer |
| Model | pH450 |
| Measurement Range | –2.00 to 16.00 pH |
| Resolution | 0.01 pH |
| Accuracy | ±0.01 pH |
| Calibration Points | Up to 5 (USA/NIST), up to 6 (DIN), or up to 5 user-defined points |
| Buffer Recognition | Automatic (USA/NIST/DIN) |
| Calibration Expiry Alert | Configurable |
| Data Storage | 500 datasets with timestamp (RTC) |
| Connectivity | USB and RS232 |
| Power | 2 × AA batteries (typical life >2000 hours) or optional AC adapter |
| Enclosure Rating | IP67 |
| Electrode Interface | BNC |
| Temperature Unit | °C/°F selectable |
| GLP Compliance | Yes (time-stamped calibration & measurement records) |
| Heating Temperature Range | Ambient to 350 °C |
|---|---|
| Heater Type | Cartridge Heater |
| Max. Sample Volume | <10 mL |
| Carrier Gas | Nitrogen or Dry Air (dry air compressor optional) |
| Gas Flow Rate | 30–300 L/min |
| Inlet Pressure | ≤0.8 MPa |
| Desiccant | Molecular Sieve |
| Power Supply | AC 100–240 V, 50/60 Hz, 100 VA |
| Dimensions (W×D×H) | 220 × 430 × 200 mm |
| Weight | Approx. 8 kg |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | EV-2000L |
| Pricing | Available Upon Request |
| Moisture Evaporation Method | Azeotropic Distillation with Inert Carrier Gas |
| Heating Range | Ambient to 200 °C |
| Heater Type | Band Heater |
| Max Sample Volume | ≤10 mL |
| Azeotropic Solvent | Toluene or Xylene (5–10 mL per analysis) |
| Carrier Gas | Nitrogen or Dry Compressed Air (optional integrated air dryer/pump available) |
| Gas Flow Rate | 30–300 L/min |
| Inlet Pressure | ≤0.8 MPa |
| Desiccant | Molecular Sieve (4 Å) |
| Power Supply | AC 100–240 V, 50/60 Hz, 150 VA |
| Dimensions (W×D×H) | 220 × 370 × 265 mm |
| Net Weight | ~7 kg |
| Brand | EWIN-TECH |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | Nova UC1000 |
| Pricing | Upon Request |