| Brand | Junyi |
|---|---|
| Origin | Beijing, China |
| Model | NZG-A |
| Gel Drying Area | 450 × 330 mm |
| Temperature Settings | 60 °C and 80 °C (dual fixed-point heating) |
| Timer Function | Yes |
| Dimensions (L×W×H) | 690 × 480 × 185 mm |
| Net Weight | 16.5 kg |
| Category | Gel Dryer for Electrophoresis Applications |
| Brand | Junyi |
|---|---|
| Origin | Beijing, China |
| Model | UV-II |
| Instrument Type | Portable (Handheld) |
| Wavelengths | 254 nm and 365 nm |
| Total Power | 8 W (4 W per lamp) |
| Reflective Illumination Area (W × L) | 200 × 50 mm |
| Dimensions (L × W × H) | 270 × 78 × 110 mm |
| Net Weight | 0.55 kg |
| Compliance | CE-marked for laboratory use (IEC 61010-1), RoHS compliant |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic (PRC-manufactured) |
| Models | JY200C, JY300C, JY600C, JY1000C, JY1600C |
| Instrument Type | Protein Electrophoresis Power Supply |
| Gel Format Compatibility | Standard vertical mini-gels (e.g., 8 × 10 cm), horizontal gels, and blotting modules |
| Sample Capacity | Up to 10 samples per run |
| Output Range | 1–200 W (JY200C) to 1–300 W (JY600C/JY1000C) / 1–160 W (JY1600C) |
| Voltage Range | 5–200 V (JY200C) to 20–1600 V (JY1600C) |
| Current Range | 1–2000 mA (JY200C) to 1–1600 mA (JY1600C) |
| Resolution | 1 V / 1 mA / 1 W |
| Timer | 1 min – 99 h 59 min |
| Display | Backlit LCD (128 × 64 pixels) |
| Dimensions (L×W×H) | 28×24×11 cm (JY200C/JY300C), 27×26×12 cm (JY600C/JY1000C/JY1600C) |
| Weight | 3.2 kg (JY200C/JY300C), 6.8–7.7 kg (JY600C–JY1000C) |
| Brand | Keebio |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Keebio-Blot1000 |
| Instrument Type | Semi-Dry Electrophoretic Transfer Apparatus |
| Electrophoresis Chamber | Integrated Dual-Compartment Transfer Cassette |
| Gel Format Compatibility | 1–4 × 70 × 85 mm gels or 1–2 × 135 × 85 mm gels |
| Voltage Range | 0–25 V (1 V increments) |
| Current Range | 0–2.5 A (0.1 A increments) |
| Dimensions (W×D×H) | 290 × 250 × 235 mm |
| Display | 5-inch capacitive touchscreen |
| Dual Independent Transfer Chambers | Yes |
| Predefined Protocols | 9 factory presets + 9 user-defined protocols (auto-saved) |
| Cooling | Active forced-air thermal management system |
| Weight | 3.6 kg |
| Brand | Keebio |
|---|---|
| Origin | Shanghai, China |
| Model | BP300 |
| Instrument Type | Electrophoresis Power Supply |
| Output Modes | Constant Voltage / Constant Current / Constant Power |
| Voltage Range | 10–300 V (±1 V accuracy) |
| Current Range | 4–400 mA (±1 mA accuracy) |
| Max Power | 100 W |
| Timer Range | 1–999 min (adjustable) |
| Output Ports | 4 independent DC output channels |
| Display | 3-digit LED |
| Operating Environment | 0–40 °C, 0–95% RH (non-condensing) |
| Dimensions (W×D×H) | 240 × 190 × 50 mm |
| Weight | 1.1 kg |
| Safety Certifications | Overload, short-circuit, no-load, surge, and power-fail protection |
| Input Power | AC 220 V, 50/60 Hz |
| Brand | Keebio |
|---|---|
| Origin | Shanghai, China |
| Model | HE110 |
| Gel Tray Dimensions | 75 × 60 mm |
| Max Voltage | 500 V |
| Buffer Capacity | 300 mL |
| Sample Capacity | 6–11 wells per comb (4 comb types included) |
| Electrode Material | 99.95% Pure Platinum |
| Housing Material | Injection-Molded Polycarbonate |
| Dimensions (L×W×H) | 230 × 100 × 65 mm |
| Weight | 1.2 kg |
| Compliance | CE-marked design for laboratory use under ISO/IEC 17025-aligned environments |
| Brand | Keebio |
|---|---|
| Model | HE130 |
| Instrument Type | Horizontal Nucleic Acid Electrophoresis Apparatus |
| Gel Dimensions (mm) | 130 × 200, 130 × 150, 60 × 120, 60 × 60 |
| Max Voltage | 500 V |
| Buffer Capacity | 800 mL |
| Sample Wells | 2–25 wells (configurable via comb selection) |
| Comb Options | 1.0 mm (25 teeth), 1.5 mm (13/18 teeth), 2.0 mm (3 teeth) |
| Max Sample Volume per Well | 15–550 µL |
| External Dimensions (mm) | 320 × 180 × 85 |
| Weight | 1.2 kg |
| Electrode Material | 99.95% Pure Platinum |
| Housing Material | Injection-Molded Polycarbonate |
| Gel Casting | Integrated Multi-Size Gel Tray System (no tape sealing required) |
| Operating Temperature Range | Up to 135 °C (tray material) |
| Brand | Keebio |
|---|---|
| Origin | Shanghai, China |
| Model | HE260 |
| Electrophoresis Tank Type | Horizontal |
| Max Gel Dimensions (mm) | 245 × 250 / 245 × 125 |
| Max Sample Capacity | 350 samples per run |
| Max Voltage | 500 V |
| Buffer Volume Capacity | 1660 mL |
| Gel Casting Volume | 350–400 mL (245×250 mm) or 175–200 mL (245×125 mm) |
| Dimensions (L×W×H, mm) | 440 × 280 × 130 |
| Weight | 3 kg |
| Electrode Material | 99.99% Pure Platinum |
| Adjustable Leveling Feet | Yes |
| Replaceable Electrode Assembly | Yes |
| Comb Options | 1.0 mm & 1.5 mm thickness |
| Brand | Keebio |
|---|---|
| Origin | Shanghai, China |
| Model | Keebio-600C, Keebio-600D |
| Output Modes | Constant Voltage / Constant Current / Constant Power |
| Voltage Range | 5–600 V |
| Current Range (600C/600D) | 1–600 mA / 1–1200 mA |
| Power Range (600C/600D) | 5–300 W / 5–500 W |
| Resolution | 1 V / 1 mA / 1 W |
| Timer Range | 1 min – 99 h 59 min |
| Timer Steps | Up to 10 steps per program, 10 programs stored |
| Display | 7-inch capacitive touchscreen (128×64 pixel backlight LCD) |
| Output Ports | 4 independent DC output channels |
| Temperature Monitoring Range | −20 °C to +85 °C |
| Dimensions (W×D×H) | 340 × 300 × 130 mm |
| Weight | 3.6 kg |
| Input Power | AC 220 V, 50/60 Hz |
| Safety Protections | Over-current, over-load, over-temperature, no-load, short-circuit, load variation, and micro-current hold protection |
| Brand | Keebio |
|---|---|
| Model | KEEBIO-600N |
| Output Type | Constant Voltage / Constant Current / Constant Power |
| Voltage Range | 0–600 V |
| Current Range | 0–600 mA |
| Power Range | 0–300 W |
| Resolution | 1 V / 1 mA / 1 W |
| Timer Range | 1 min – 99 h 59 min |
| Display | Backlit LCD (128×64 pixels) |
| Output Channels | 4 independent ports (supports simultaneous connection to four electrophoresis tanks) |
| Gel Tray Compatibility | Up to 120 × 120 mm |
| Dimensions (W×D×H) | 340 × 200 × 280 mm |
| Weight | 3.1 kg |
| Input Power | AC 220 V, 50/60 Hz |
| Safety Features | Overload, no-load, leakage current, and auto-recovery protection |
| Memory Capacity | 10 programmable protocols (0–9) |
| Housing | Stackable, anti-slip chassis |
| Brand | Keebio |
|---|---|
| Origin | Shanghai, China |
| Model | Keebio-600S |
| Output Modes | Constant Voltage / Constant Current / Constant Power |
| Voltage Range | 3–600 V |
| Current Range | 4–800 mA |
| Power Range | 1–300 W |
| Display Resolution | 0.1 V / 0.1 mA / 0.1 W |
| Timer Range (Single Step) | 1–9999 min |
| Timer Range (Multi-Step, 10 steps × 10 programs) | 1–999 min per step |
| Output Ports | 4 independent DC outputs |
| Input | AC 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 250 × 230 × 90 mm |
| Weight | 1.5 kg |
| Brand | Keebio |
|---|---|
| Origin | Shanghai, China |
| Model | KEEBIO-HE120 |
| Gel Dimensions | 60×60 mm, 120×60 mm, 120×120 mm (max) |
| Sample Capacity | Up to 2 gels simultaneously |
| Voltage Input | 220 V AC |
| Buffer Volume Capacity | 660 mL |
| Electrode Material | 99.95% pure platinum |
| Housing Material | Injection-molded polycarbonate |
| Weight | 1.2 kg |
| External Dimensions | 310 × 155 × 70 mm |
| Comb Options | 8 types (1.0 mm, 1.5 mm, 2.0 mm thickness |
| Max Loading Volume per Well | 15–550 µL (depending on comb configuration) |
| Gel Casting | Compatible with multi-purpose casting trays (no tape sealing required) |
| Thermal Stability of Casting Tray | Up to 135 °C |
| Brand | Keebio |
|---|---|
| Origin | Shanghai, China |
| Model | KEEBIO-VE180 |
| Instrument Type | Vertical Electrophoresis Apparatus |
| Gel Dimensions (Hand-cast) | 83 × 73 mm |
| Gel Thickness Options | 0.75 mm / 1.0 mm / 1.5 mm (default: 1.0 mm) |
| Max Gel Capacity | 2 gels (standard), upgradable to 4 gels (optional) |
| Voltage Input | 220 V AC |
| External Dimensions | 170 × 120 × 120 mm |
| Electrode Material | 99.95% Pure Platinum |
| Weight | 2.56 kg |
| Compliance | CE-marked design principles |
| Sample Capacity | 1 gel unit per run (dual-gel configuration supported) |
| Brand | Keebio |
|---|---|
| Model | MiniES |
| Type | Horizontal Submarine Electrophoresis Apparatus |
| Gel Tray Dimensions | 120 × 60 mm and 60 × 60 mm (included) |
| Max Gel Size | 126 × 126 mm |
| Buffer Capacity | 230 mL |
| Output Voltage Options | DC 35 V / 50 V / 100 V (fixed, user-selectable) |
| Timer Range | 1–99 min |
| Input Power | AC 100–240 V, 50–60 Hz |
| Power Consumption | 40 W |
| Chamber Internal Dimensions (W×D×H) | 110 × 121 × 43 mm |
| Housing Material | High-Temperature-Resistant Alloy Polymer |
| Overall Dimensions (W×D×H) | 205 × 140 × 60 mm |
| Weight | 0.8 kg |
| Safety | Lid-Interlocked Auto-Shutoff Circuit |
| Included Comb Sets | 3 × 1 × 22 mm, 5.6 × 1 × 12 mm, 3 × 1 × 18 mm, 5.6 × 1 × 10 mm |
| Brand | Keebio |
|---|---|
| Model | VE186 |
| Type | Semi-dry electroblotting transfer apparatus |
| Max Gel Size | 110 × 90 mm |
| Gel Capacity | 2 gels simultaneously |
| Electrode Spacing | 40 mm |
| Buffer Volume | 450 mL |
| Dimensions (L×W×H) | 180 × 140 × 155 mm |
| Weight | 1 kg |
| Electrode Material | 99.95% pure platinum wire |
| Cooling | Integrated ice chamber for temperature control during transfer |
| Compatible With | Keebio VE180 vertical electrophoresis system |
| Transfer Time Range | 30–60 min (standard) or low-voltage overnight protocol |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | A160WE |
| Price | Upon Request |
| Brand | Kylin-Bell |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Regional Category | Domestic (PRC) |
| Model | GL-1000 |
| Instrument Type | Benchtop |
| Wavelength Type | Single Wavelength |
| Blue Light Peak Emission | 470 nm |
| Excitation Area | 100 × 150 mm |
| Illumination Source | 108 high-output, long-life LEDs |
| Filter Cover | Full-size transparent acrylic filter lid |
| Power Input | DC 24 V via external adapter |
| Dimensions (W×D×H) | 210 × 210 × 30 mm |
| Net Weight | 1.3 kg |
| LED Lifetime | ≥10,000 hours |
| Compliance | CE-marked, RoHS-compliant, GLP-supportive design |
| Brand | Kylin-Bell |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | GL-312 |
| Instrument Type | Benchtop |
| Wavelength Type | Single Wavelength |
| UV Wavelength | 312 nm |
| Number of UV Lamps | 6 |
| UV Filter Size | 200 × 150 mm |
| UV Transillumination Area | 200 × 150 mm |
| UV Lamp Specification | 312 nm, 8 W each |
| Total Power Consumption | 48 W |
| Input Voltage | AC 220 V |
| External Dimensions | 420 × 300 × 65 mm |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | UV-2000F |
| Instrument Type | Benchtop |
| Wavelength Range | 250–450 nm |
| Optical Resolution | ±1 nm |
| Measurement Area | 0.67 cm² |
| Dynamic Range | 2.7 AU |
| Light Source | Pulsed Xenon Flash Lamp |
| Detector | Custom Concave Holographic Grating Diode Array Spectrometer |
| Compliance Standards | AS/NZS 4399:2017, EN 13758-1:2007, AATCC TM183-2014, GB/T 18830:2009, JIS L 1096 & JIS L 1925 |
| Software Platform | Windows XP/7 Compatible, FDA 21 CFR Part 11–Ready Audit Trail Mode (Optional), GLP/GMP-Compliant Reporting |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | UV-2000S |
| Instrument Type | Benchtop |
| Wavelength Range | 250–450 nm |
| Measurement Speed | <5 seconds per sample |
| Compliance | COLIPA UVA-PF, ISO 24443:2012, FDA 2011 Sunscreen Final Rule, Revised Boots Star Rating |
| Optical Configuration | Double-beam spectrophotometric transmittance system with integrating sphere detection |
| Sample Platform | Manual precision XYZ stage with pre- and post-irradiation baseline capture |
| Calibration Standards | NIST-traceable wavelength and transmittance standards covering six critical UV bands |
| Software | UV-2000S Control & Analysis Suite (v5.x) with 21 CFR Part 11-compliant audit trail and electronic signature support |
| Ozone Generation | None |
| Fluorescence Interference Rejection | Enabled via spectral deconvolution algorithm |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | UV2000 |
| Instrument Type | Benchtop |
| Wavelength Range | 250–450 nm |
| Light Source | Pulsed Xenon Lamp |
| Detector | High-Performance Diode Array Spectrometer |
| Optical Integration | Spectralon® Integrating Sphere |
| Wavelength Accuracy | ±1 nm |
| Measurement Time | <5 s per sample |
| UV Band Calculation | UVA (315–400 nm), UVB (280–315 nm) |
| Compliance Standards | AS/NZS 4399:1996, EN 13758-1:2001, AATCC TM 183-2000, ISO 17166:2019, GB/T 18830, CIE S107/E |
| Brand | Leopard |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | POWER 600H |
| Instrument Type | Protein Electrophoresis Power Supply |
| Voltage Range | 5–1000 V |
| Current Range | 1–1000 mA |
| Power Output | 1–300 W |
| Dimensions | 320 × 220 × 80 mm (L × W × H) |
| Display | LCD with simultaneous real-time readout of voltage, current, power, and timer |
| Output Modes | Constant Voltage, Constant Current, Constant Power |
| Timer Range | 1 min – 99 h 59 min |
| Weight | 3.5 kg |
| Safety Features | Overvoltage, arc, open-circuit, and load-surge detection |
| Thermal Management | Integrated temperature control (standard) |
| Parallel Output | Four independent output channels for concurrent multi-gel operation |
| Brand | Longlight |
|---|---|
| Model | EP-300 |
| Output Modes | Constant Voltage / Constant Current |
| Timer Range | 0–999 min |
| Max Output | 300 V / 400 mA / 120 W |
| Input Voltage | 100–240 V AC, 50/60 Hz |
| Safety Features | Overload, Overheat, and Short-Circuit Protection |
| Memory Function | Yes |
| Multi-Channel Capability | Supports up to four identical electrophoresis tanks simultaneously |
| Compliance | CE, RoHS, ISO 9001-certified manufacturing |
| Brand | LUM |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Instrument Category | Imported |
| Model | Capel 205 |
| Instrument Type | U-Tube Capillary Electrophoresis System |
| Primary Unit | Electrophoresis System with Integrated Separation Chamber |
| Capillary Dimensions | 30–120 cm length × 50 or 75 µm ID |
| Sample Capacity | 59-position autosampler (Eppendorf 2 mL tubes) |
| Voltage Range | ±30 kV (0.1 kV step, polarity auto-switching) |
| Current Range | 0–300 µA |
| Separation Power | Up to 9 W |
| Pressure Range | −100 to +2000 mbar (injection), 500–8000 mbar (flushing, 1 mbar step) |
| Detection Wavelength | 190–600 nm (Xenon lamp, ±1 nm accuracy) |
| Capillary Temperature Control | −10 °C to +65 °C (±0.1 °C stability, water-cooled) |
| Software | Elforun-205 (PC-based, GLP-compliant data acquisition & reporting) |
| Brand | LY |
|---|---|
| Origin | Beijing, China |
| Model | DYCP-31CN |
| Instrument Type | Nucleic Acid Electrophoresis Apparatus |
| Gel Tray Dimensions (L × W) | 100 × 70 mm |
| Sample Combs | 8-well and 15-well, 1.0 mm and 1.5 mm thickness |
| Overall Dimensions (L × W × H) | 270 × 115 × 110 mm |
| Buffer Capacity | 260 mL |
| Weight | 1 kg |
| Brand | LY (Beijing Liuyi) |
|---|---|
| Origin | Beijing, China |
| Model | DYCP-31DN |
| Instrument Type | Nucleic Acid Electrophoresis Apparatus |
| Gel Tray Dimensions (L×W) | 120×120 mm (large), 120×60 mm (wide), 60×120 mm (long), 60×60 mm (small) |
| Sample Combs | 2+3 teeth (2.0 mm thickness), 6+13 teeth, 8+18 teeth (1.0 mm & 1.5 mm thickness), 11+25 teeth (1.0 mm thickness) — compatible with multichannel pipettes |
| External Dimensions (L×W×H) | 310 × 150 × 120 mm |
| Buffer Capacity | 650 mL |
| Weight | 1 kg |
| Brand | LY |
|---|---|
| Origin | Beijing, China |
| Model | DYCP-31E |
| Instrument Type | Nucleic Acid Electrophoresis Apparatus |
| Gel Tray Dimensions (L × W) | 200 × 160 mm and 150 × 160 mm |
| Overall Dimensions (L × W × H) | 360 × 195 × 135 mm |
| Buffer Capacity | 1000 mL |
| Sample Combs | 17- and 34-well, 1.0 mm and 1.5 mm thickness |
| Weight | 1.5 kg |
| Construction Material | Polycarbonate injection-molded body |
| Electrode Assembly | Removable platinum-coated stainless steel electrodes |
| Safety Features | Insulated flexible leads, built-in comb positioning stops, bridge-style buffer chamber design |
| Brand | LY |
|---|---|
| Origin | Beijing, China |
| Model | DYCP-32B |
| Instrument Type | Nucleic Acid Electrophoresis Apparatus |
| Gel Tray Dimensions (L × W) | 200 × 130 mm, 150 × 130 mm |
| Overall Dimensions (L × W × H) | 365 × 165 × 130 mm |
| Buffer Capacity | 800 mL |
| Weight | 1.5 kg |
| Sample Comb Options | 14-, 26-, and 18-tooth combs |
| thicknesses | 1.0 mm and 1.5 mm |
| Material | Polycarbonate (injection-molded, leak-proof) |
| Design Features | Bridge-type electrode configuration, removable electrode assembly, transparent lid, integrated gel caster |
| Brand | LY |
|---|---|
| Origin | Beijing, China |
| Model | DYCP-37B |
| Instrument Type | Isoelectric Focusing (IEF) Electrophoresis Apparatus |
| Gel Plate Dimensions (L × W) | 140 × 190 mm and 60 × 190 mm |
| Thickness Options | 0.4 mm and 1.0 mm |
| External Dimensions (L × W × H) | 330 × 290 × 115 mm |
| Buffer Capacity | 750 mL |
| Weight | 3.5 kg |
| Brand | LY |
|---|---|
| Origin | Beijing, China |
| Model | DYCP-38C |
| Instrument Type | Cellulose Acetate Membrane Protein Electrophoresis System |
| Sample Capacity | 6–8 cellulose acetate membranes (1–2 samples per membrane) |
| Voltage Range | 0–600 V |
| Current Range | 0–100 mA |
| Operating Modes | Constant Voltage / Constant Current / Constant Power |
| Dimensions (L × W × H) | 370 × 270 × 110 mm |
| Buffer Volume | 1000 mL |
| Electrode Material | Triple Platinum Wire Electrodes |
| Gel/Matrix Compatibility | Cellulose acetate membranes (70 or 90 mm length × 250 mm width, dual-lane format) |