Emergency/Portable/Vehicle-mounted
Filter
Showing 31–60 of 200 results
| Brand | Eranntex |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | MS400-CH4 |
| Pricing | Upon Request |
| Brand | Eranntex |
|---|---|
| Origin | Shenzhen, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | TH-2000-C-C2H₆ |
| Detection Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Target Gas | Ethane (C₂H₆) |
| Measurable Gases (Optional) | NOₓ, NO, NO₂, O₂, SO₂ |
| Operating Temperature Range | −40 °C to +70 °C |
| Enclosure Rating | IP66 |
| Display | 7-inch TFT capacitive touchscreen |
| Output Signals | 4–20 mA, RS485, dry contact alarms |
| Communication Options | DTU (GPRS), Ethernet, optional MQTT/HTTP API |
| Sampling Method | Pump-suction, configurable flow (2–10 L/min) |
| Sampling Distance | Up to 40 m (standard), >70 m with vacuum pump option |
| Sample Conditioning | Dual-stage thermoelectric cooler, 0.5 m stainless steel particulate filter (flanged), automatic condensate drainage |
| Max. Sample Gas Temp. | 600 °C (custom up to 2000 °C) |
| Humidity Tolerance | 0–99 % RH (pre-conditioned) |
| Data Storage | Optional 16 GB SD card or internal 100,000-record buffer |
| Brand | EXPEC / Spectral Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | EXPEC 1920 |
| Pricing | Upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | GC-1010 |
| Pricing | Available Upon Request |
| Channel Configurations | 10-channel (GC-1010) / 2-channel (GC-1010-C) |
| Power Supply Output | 24 VDC active output (1 channel) |
| Display | LCD + high-brightness LED indicators |
| Communication Interfaces | RS-485 and Ethernet |
| Signal Input Compatibility | 2-wire and 3-wire toxic & combustible gas detectors |
| Alarm Logic | Multi-sensor intelligent voting algorithm |
| Data Acquisition | Synchronized multi-channel sampling |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | GC-1020 |
| Pricing | Upon Request |
| Channel Capacity | 10-channel |
| Display | Dual-mode — 10-digit high-brightness LED + LCD |
| Input Compatibility | 2-wire & 3-wire toxic/combustible gas sensors |
| Communication | RS485 (Modbus RTU standard), optional Ethernet interface |
| Analog Output | Optional 10-channel 4–20 mA |
| Power Output | 1-channel 24 VDC active output |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | GC-3010 |
| Pricing | Available Upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic (China) |
| Model | GC-3020 |
| Pricing | Upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | Mobile Emergency Atmospheric Monitoring Vehicle |
| Pricing | Available Upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | Domestic (China) |
| Model | Mobile Water Emergency Monitoring Vehicle |
| Pricing | Available Upon Request |
| Brand | CASP |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GA2202 |
| Detection Gases | Methane (CH₄), Ethane (C₂H₆) |
| Detection Principle | Mid-Infrared Absorption + Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Response Time | <1 s |
| Measurement Speed | Up to 60 km/h mobile survey |
| Dual-Gas Simultaneous Quantification | Yes |
| Operating Temperature Control | Active Thermostatic Stabilization |
| Measurement Range | Wide-range configurable for urban ambient monitoring, station boundary monitoring, and landfill/anaerobic digester plume tracking |
| Data Security & Support | Fully domestic R&D and manufacturing, local service network |
| Brand | Komyo Rika |
|---|---|
| Origin | Japan |
| Model | 600SP |
| Detection Range | 2.5–5 ppm and 5–100 ppm |
| Application | Respiratory gas purity verification in medical O₂ cylinders, fire service SCBA cylinders, diving air tanks |
| Brand | Komyo Rikagaku |
|---|---|
| Origin | Japan |
| Model Numbers | 106SC (CO), 126SF (CO₂), 177UR (H₂O vapor) |
| Detection Principle | Colorimetric Length-of-Stain |
| Pump | AP-20 Manual Bellows Pump |
| Calibration Traceability | NIST-traceable standards |
| Compliance | ASTM D3928, ISO 8573-3 (for compressed gas purity verification), JP XVIII General Chapter 2.40 |
| Origin | United Kingdom |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GA-m |
| Pricing | Upon Request |
| Brand | Ability Technology |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | PPA-6100 |
| Target Analytes | Thallium (Tl), Cadmium (Cd), Silver (Ag), Zinc (Zn) in environmental water matrices |
| Detection Limit | Tl ≤ 0.005 ppb |
| Analysis Time | < 120 s per sample |
| Power Consumption | Low |
| Form Factor | Compact, Portable, Vehicle-Mountable |
| Gas Consumption | Low |
| Interference Resistance | High |
| Positioning | Integrated High-Precision GNSS Module (enables future online monitoring integration) |
| Brand | Graywolf |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | Domestic (China) |
| Model | AdvancedSense XM |
| Detection Medium | Gases |
| Detectable Parameters | TVOC, HCHO, CO₂, SO₂, O₃, NO₂, O₂, NO, NH₃, CO, Cl₂, H₂S, H₂, HCN, F₂, HCl, PH₃, HF, AsH₃, C₂H₄O, SiH₄, ClO₂, COCl₂, B₂H₆ (20+ gases selectable) |
| Particle Measurement | PM₂.₅, PM₁₀, TSP (0.3–25 µm, 6-channel configurable) |
| Meteorological Parameters | Air velocity (hot-wire & pitot tube), volumetric flow (m³/min), static/differential pressure, temperature (ambient, surface, liquid, thermocouple), relative/humid/absolute/specific/wet-bulb humidity |
| Brand | Graywolf |
|---|---|
| Model | DSII-5 |
| Origin | Beijing, China |
| Distribution Status | Authorized Distributor |
| Detection Targets | TVOC, HCHO, NH₃, CO, CO₂, Temperature, Relative Humidity, and >20 Gaseous Parameters |
| Response Time (90%) | <1 min |
| Units | mg/m³, µg/m³, ppm, ppb, % |
| Operating System | Wolf OS |
| Data Logging | Real-time & Long-term Continuous Monitoring |
| Probe Interchangeability | Hot-swappable modular sensor architecture |
| Display Annotation | Text, voice, image tagging during measurement |
| Origin | Zhejiang, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | GT-1030 |
| Pricing | Available Upon Request |
| Brand | BCT |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | Domestic (China) |
| Model | Hapline M8800 |
| Detection Target | Volatile Organic Compounds (VOCs) |
| Detection Mode | Dual-Mode (Real-Time Single-Quadrupole MS + Stationary GC-MS Quantification) |
| Weight | <40 kg |
| Vacuum System | Non-Mechanical (Turbomolecular + Ion Pump Hybrid) |
| Operating Interface | Detachable Touchscreen Control Panel (Local & Remote Operation Supported) |
| Data Transmission | Cloud-Integrated Platform with Real-Time Telemetry |
| Compliance | Designed to Support ASTM D6348, EPA TO-15/TO-17, and GB 50325–2020 Method Requirements |
| Brand | Hexin Mass Spectrometry |
|---|---|
| Origin | Guangdong, China |
| Model | ICP-MS 1000 |
| Configuration | Vehicle-mounted integrated system with ICP-MS, sampling toolkit, power & gas supply units, communication module, and environmental control subsystem |
| Vacuum System | Dual turbo-molecular pumps (cold-start time ≈ 30 min) |
| Sample throughput | ~3–5 min per sample (post-preparation) |
| Power Supply | Dual-mode (AC grid + imported industrial-grade generator) |
| Vibration isolation | Full-vehicle active/passive damping architecture |
| Air purification | Onboard catalytic filtration compliant with GB/T 18883–2022 indoor air quality standards |
| Regulatory alignment | Designed to support EPA Method 200.8, ISO 17294-2:2016, and China HJ 680–2013 workflows |
| Brand | Hirschmann |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | COD |
| Pricing | Available Upon Request |
| Brand | Hirschmann |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | COD-Cr |
| Pricing | Available Upon Request |
| Brand | Honegeagle |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | HNAG1000-4SX-T |
| Price Range | USD 2,800 – 3,900 |
| Key | Brand: Honeywell |
|---|---|
| Origin | USA |
| Model | LP-1200 |
| Type | Manual piston sampling pump (not a standalone gas analyzer) |
| Compatible With | Standard-length colorimetric gas detection tubes (e.g., Honeywell, Dräger, Gastec) |
| Sampling Volumes | 50 mL or 100 mL per stroke |
| Sealing Mechanism | Plug-type vacuum seal cylinder with conical rubber inlet tip |
| Visual Indicators | Gray-to-white window transition during sampling |
| Leak Check Procedure | Built-in 2-minute vacuum hold test (≤3 mm piston drift) |
| Maintenance | Replaceable rubber inlet tip, washable/replacement inlet filter, vacuum-lubricated piston assembly, serviceable one-way valve |
| Brand | Junray |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | ZR-3110C |
| Detection Target | VOCs (Volatile Organic Compounds) |
| Sensor Technologies | Electrochemical (EC), Catalytic Bead (LEL), Photoionization Detection (PID) |
| Compliance Standards | GB 12358–2006, HJ 872–2017, GBZ 2.1–2019, GB/T 36198–2018, JJF 1172–2007, JJG 915–2008, JJG 635–2011, JJG 551–2003, JJG 695–2003, JJG 693–2011, Q/0214 ZRB008–2017 |
| Brand | Junray |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | ZR-7600 |
| Detection Medium | Gaseous |
| Detection Capability | Multi-gas |
| Response Time | < 30 seconds (typical for electrochemical & PID sensors) |
| Brand | Meiko Rikka |
|---|---|
| Origin | Japan |
| Model | 602SP |
| Detection Principle | Colorimetric Reaction via Impregnated Reagent Layer |
| Target Analyte | Oil Mist (Hydrocarbon Aerosol) |
| Measurement Range | 0.3–5 mg/m³ |
| Response Time | 25 min |
| Operating Temperature | 0–40 °C |
| Storage Condition | 0–25 °C, dark and dry |
| Required Accessories | Kawakami P-40R Compressed Air Sampling Kit with Regulator & Flow Control |
| Compliance Reference | DIN 3188, CSA Z180.1, BS EN 12021, ISO 8573-1 Class 2 (for oil aerosol), CGA G-4.1 |
| Brand | Kohei Rikka |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 603SP |
| Pricing | Upon Request |
| Brand | Meikō Rika |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 290Pǁ |
| Price | USD 55 |
| Brand | Kikuchi |
|---|---|
| Origin | Japan |
| Model | 171SA, 171SB, 171SC |
| Detection Principle | Colorimetric Reaction with Pre-calibrated Glass Tube |
| Measurement Unit | ppm (parts per million) |
| Sampling Device | Manual Bellows Pump AP-20 |
| Compliance | JIS K 0321 (Japanese Industrial Standard for Air Quality Testing), ISO 16000-23 (Indoor Air – Determination of Formaldehyde – Active Sampling Using Chromatographic Methods – Reference for Validation of Screening Methods) |
| Packaging | Individually sealed in aluminum pouches with desiccant |
| Shelf Life | 24 months from manufacture date when stored at ≤25°C and <60% RH |
| Operating Temperature Range | 10–35°C |
| Relative Humidity Limit | ≤80% RH (non-condensing) |
| Calibration Traceability | NIST-traceable reference standards used during production batch validation |
| Brand | Meiko Rikka |
|---|---|
| Origin | Japan |
| Model | 710 / 710A / 713 |
| Detection Range (710) | 0.01–0.48 ppm |
| Detection Range (710A) | 0.05–2.0 ppm |
| Detection Range (713) | 0.01–0.50 ppm |
| Detection Range (171SA) | 20–1500 ppm |
| Detection Range (171SB) | 1–35 ppm |
| Detection Range (171SC) | 0.05–4.0 ppm |
| Format | Colorimetric Glass Tube |
| Required Sampling Device | ASP-1200 Electric Pump (for 710/710A/713) or AP-20 Manual Pump (for 171-series) |
| Pack Size | 710/710A/713: 20 tubes/box |
| 171SA/SB | 10 tubes/box (5×2) |
| 171SC | 10 tubes/box |
