Showing 181–200 of 200 results
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | XHBX6003 |
| Detection Target | Gaseous Pollutants |
| Measured Parameters | NO, NO₂, NOₓ |
| Response Time | ≤100 s |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | XHBX6004 |
| Detection Target | Gaseous Analytes |
| Measured Parameters | SO₂, CO |
| Response Time | ≤120 s |
| Environmental Sensors Integrated | Ambient Temperature, Atmospheric Pressure |
| Compliance Basis | GB/T 15439–1995, HJ 693–2014, HJ 973–2018 |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | XHBXI9100 |
| Pricing | Upon Request |
| Brand | Senbe |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | EDXP3600 |
| Price | Upon Request |
| Excitation Source | 50 kV / 200 µA Ag-target micro-focus X-ray tube, end-window configuration, ≤4 W power match |
| Detector | 25 mm² fast Silicon Drift Detector (SDD), 0.3 mil Be window, energy resolution ≤125 eV (Mn Kα), Peltier-cooled |
| MCA | 4096-channel digital pulse processor |
| Elemental Range | Na (11) to U (92) |
| Analysis Modes | Alloy, RoHS, Soil, Water |
| Soil LODs (SiO₂ matrix) | Pb <5 mg/kg, As <3 mg/kg, Cr <15 mg/kg, Cu <10 mg/kg, Zn <2 mg/kg, Ni <5 mg/kg, Mn <10 mg/kg, Hg <1 mg/kg, Cd <3 mg/kg |
| Water LODs (aqueous matrix) | Pb <1 mg/L, As <0.5 mg/L, Cr <2 mg/L, Cu <1 mg/L, Zn <2 mg/L, Ni <1 mg/L, Mn <2 mg/L, Hg <1 mg/L, Cd <1 mg/L |
| Quantification Time | 3–60 s (user-adjustable) |
| Repeatability | RSD <4% (for major elements in homogeneous alloys) |
| Collimation & Filters | 6 interchangeable filters + multiple collimators → 18 automatic combinations |
| Display | 5.5″ high-brightness capacitive touchscreen LCD |
| Processor | Intel quad-core @ 1.33 GHz |
| Memory | 2 GB RAM, 32 GB internal storage (expandable via microSD) |
| Connectivity | Wi-Fi 802.11 b/g/n, Bluetooth 4.0, USB 2.0, GPS module |
| Safety | Beam-on detection sensor, auto X-ray cutoff during air measurement |
| Weight | 1.5 kg (with battery) |
| Operating Environment | –20 °C to +50 °C, RH <90% non-condensing |
| Power | Rechargeable Li-ion, 6700 mAh, >6 h typical operation |
| Data Output | Excel, BMP, PDF reports |
| Compliance | Meets IEC 62471 (LED/X-ray safety), ISO 12885 (XRF safety guidance), and supports GLP/GMP audit trail requirements via timestamped, user-logged data export |
| Brand | SenTinain |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | N/A |
| Price | USD 6,850 (FOB Beijing) |
| Brand | Shengaohua |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Model | SH-9007 |
| Detection Parameters | COD (high/low range), Ammonia Nitrogen, Total Phosphorus, Total Nitrogen, Heavy Metals (Cr⁶⁺, Cr-total, Zn, Ni, Fe, Cu, Mn, Al, Ag, Cd, CN⁻, S²⁻), Free Chlorine, Total Chlorine, ClO₂, Formaldehyde, Turbidity, Color, SO₄²⁻, NO₃⁻-N, Anionic Surfactants, Volatile Phenols, O₃, Fluoride, KMnO₄ Index, pH, Dissolved Oxygen, Conductivity, Temperature |
| Wavelength Range | 400–860 nm |
| Measurement Repeatability | ≤ ±5% |
| Accuracy | ≤ ±5% |
| Display | 5-inch IPS Touchscreen |
| Dimensions | 247 × 105 × 59 mm |
| IP Rating | IP43 |
| Battery | Built-in Li-ion, Type-C Charging |
| Data Storage | 16 GB MicroSD (≥10 years of typical field data) |
| Preloaded Calibration Curves | 100 fixed + user-definable slots |
| Response Time | ≤10 seconds per parameter |
| Brand | Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (PRC) |
| Model | Shimadzu Mobile Laboratory |
| Pricing | Upon Request |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | VOCs-800P |
| Detection Target | NMHC (Non-Methane Hydrocarbons) |
| Detection Limit | ≤0.07 mg/m³ |
| Response Time | ≤60 s |
| Brand | Starwood |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Origin Category | Domestic (China) |
| Model | K55 |
| Pricing | Available Upon Request |
| Detector Resolution | 320 × 240 pixels |
| Thermal Sensitivity (NETD) | ≤30 mK |
| Display | 4-inch LCD, 320 × 240 resolution |
| Frame Rate | 60 Hz |
| Spectral Range | 7.5–13 µm |
| Temperature Range | –20 °C to +650 °C |
| Operating Temperature | –20 °C to +85 °C (15 min at +150 °C |
| IP Rating | IP67 |
| Weight | 1.1 kg (with battery) |
| Dimensions | <120 × 125 × 280 mm |
| Battery Life | 4 hours continuous operation |
| Video Format | MPEG-4 |
| Internal Storage | Up to 200 video files, total recording time up to 600 minutes, max clip length 5 minutes |
| Digital Zoom | 2× |
| Wake-up Time from Sleep Mode | <4 s |
| Startup Time | <17 s |
| Charging | Dual-bay desktop charger |
| Brand | TCT |
|---|---|
| Origin | Fujian, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Handset OBD |
| Response Time | 0.01 s |
| Compliance | GB 3847–2018, GB 18285–2018 |
| Connectivity | Bluetooth (BLE 4.2+), USB-C, 4G LTE Cat-4 |
| Integrated Hardware | VCI Diagnostic Interface + Rugged Industrial PDA (Android 11, IP65-rated) |
| Data Transmission | Secure HTTPS/FTP upload to Environmental Protection Bureaus’ OBD Remote Supervision Platforms |
| Brand | TCT (Xiamen Tongchuang) |
|---|---|
| Origin | Fujian, China |
| Model | VEMEIS1.0 |
| Application | In-Use Vehicle Emission Compliance Testing (Gasoline, Diesel, Motorcycle) |
| Regulatory Compliance | GB 18285–2018, GB 3847–2018, GB 19758–2005, GB 14621–2002, GB 18352.6–2016 |
| Measurement Principles | NDIR (HC, CO, CO₂), Electrochemical (NO, NO₂, O₂), Lambda Calculation, Opacity (N, K), Charged Particle Counting (PN), Thermal & Inductive Sensing (Oil Temp, RPM) |
| Detection Range | HC 0–20,000 ppm |
| Resolution & Accuracy | As per GB standards (e.g., HC ±4 ppm or ±3% rel., Opacity ±1% abs., PN ±1% FS) |
| Data Transmission | Wireless (4G/LTE), Cloud-Ready API Interface |
| Software | Integrated Emission Database Management, Audit-Trail Logging, GLP-Compliant Reporting |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrumentation |
| Model | AQ4EK1 |
| Pricing | Available Upon Request |
| Conductivity Range | 0–20.00 / 200.0 / 2000 µS/cm |
| Conductivity Resolution | 0.01 / 0.1 / 1 µS/cm |
| Conductivity Accuracy | ±1% of Full Scale |
| pH Range | 0.00–14.00 pH |
| pH Resolution | 0.01 pH |
| pH Accuracy | ±0.01 pH |
| pH Electrode Slope | 80–120% |
| mV Range | –1000 to +1000 mV |
| mV Resolution | 1 mV |
| mV Accuracy | ±2 mV |
| Temperature Range (pH/Conductivity) | –10.0–110.0 °C (Conductivity), 0.0–100.0 °C (pH) |
| Temperature Resolution/Accuracy | 0.1 °C / ±0.5 °C |
| Temperature Compensation | Automatic or Manual (0–50 °C for conductivity |
| Cell Constant Options | 0.1, 1.0, 10.0 cm⁻¹ |
| Reference Temperature Options | 20.0 °C or 25.0 °C |
| Conductivity Calibration Points | Up to 1 per range, max 5 total |
| pH Calibration Points | 1–3 points |
| Buffer Standards | USA (pH 4.01, 7.00, 10.01), NIST (pH 4.01, 6.88, 9.18), Pb (pH 4.10, 6.97) |
| Auto-Range Switching | Yes |
| Data Hold Function | Yes |
| Auto-Power-Off | 17 min (pH/mV), 20 min (conductivity) |
| Low-Battery Indicator | Yes (“LO” display) |
| Power Supply | 4 × AAA alkaline batteries |
| Battery Life | >500 h (pH/mV mode), >100 h (conductivity mode) |
| Dimensions | 14 × 7 × 3.5 cm |
| Weight | 200 g |
| Interface | BNC (conductivity sensor), needle-type thermistor port (temperature probe) |
| Display | Custom monochrome LCD |
| Brand | Torion |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TRIDION™-9 GC-TMS |
| Price | Upon Request |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | BCNX-AQ05 |
| Pricing | Upon Request |
| Brand | BCNX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Regional Category | Domestic (China) |
| Model | BCNX-AQ05 |
| Pricing | Available Upon Request |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (PRC) |
| Price Range | USD 7,000 – 70,000 |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | Reflectance-Transmittance Measurement System |
| Price Range | USD 7,000 – 70,000 |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Welcome Light Automated Inspection System |
| Price Range | USD 7,000 – 70,000 |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | Assembly Auto-Measurement System |
| Price Range | USD 7,000 – 70,000 |
| Motion Stage Accuracy | ±0.01 mm |
| Max Test Area | 2000 mm × 1500 mm |
| Measurement Parameters | Luminance, Luminance Distribution, Chromaticity (CIE x,y & u'v'), Chromaticity Uniformity, Defect Detection (pixel-level anomaly), Antenna Resistance (4-wire Kelvin) |
| Data Traceability | Full Audit Trail with Timestamped Metadata |
| Automation | Automatic Power-on/Power-off via Relay-Controlled Socket & Motorized Connector Actuation |
| Software | Region-of-Interest (ROI) Customization, Arbitrary Shape Definition, Large-Area Image Mosaic & Photometric Calibration Integration |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Model | Light Color Measurement and Calibration System |
| Price Range | USD 7,000 – 70,000 |
| Core Components | Integrating Sphere + Light-Tight Enclosure + Fiber-Optic Spectrometer + Dedicated Calibration Software + Host PC |