| Brand | Leica |
|---|---|
| Country of Origin | Germany |
| Model | GLOW800 |
| Instrument Type | Stereoscopic Fluorescence Surgical Microscope |
| Excitation Source | High-Power LED |
| Integration Platform | Fully Integrated with Leica M530 Surgical Microscope |
| Display | Full HD 1080p CaptiView In-Eyepiece Projection System |
| Contrast Ratio | 500:1 |
| Color Rendering | Multi-spectral AR Fusion (Natural Tissue + Pseudocolor ICG Fluorescence) |
| Optional Module | 3D Visualization & Recording |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | INFINITY TIRF |
| Instrument Type | Inverted Fluorescence Microscope |
| Excitation Source | Laser (405–640 nm, 1–5 lines, 60–150 mW per line) |
| Optical Architecture | Infinity-Corrected Dual-Path TIRF/EPI/Hi-Lo Illumination Module |
| Integration Platform | Leica DMi8 Inverted Microscope Base |
| Detection | sCMOS (e.g., DFC9000) with Adaptive Focus Control (AFC) |
| Objective Compatibility | PLAN APO TIRF Series |
| Software | LAS X (with TIRF alignment assistant, multi-modal acquisition, audit trail & metadata logging per frame) |
| Regulatory Context | Compliant with GLP/GMP documentation workflows |
| Brand | Leica |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | M165 FC |
| Price Range | USD 13,500 – 40,500 (FOB) |
| Instrument Type | Fluorescence Stereo Microscope |
| Excitation Source | High-Power LED-Based Fluorescence Illumination System (Compatible with Standard Filter Sets for DAPI, FITC, TRITC, Cy5) |
| Medical Device Classification | Not a Medical Device |
| Instrument Class | Research-Grade Fluorescence Stereo Microscope |
| Optical Zoom Ratio | 16.5:1 |
| Minimum Resolvable Feature Size | 1.1 µm (at maximum magnification with Plan Apo 2.0x objective and 10x eyepieces) |
| Image Encoding | Motorized, Encoder-Integrated Zoom & Focus Drive |
| Illumination Architecture | TripleBeam™ Optical Path Separation Technology |
| Imaging Mode Compatibility | Simultaneous Stereo Observation and Parallax-Free Digital Capture via FluoCombi™ Configuration |
| Modularity | Fully Modular Stand, Illumination, Camera, and Ergonomic Accessory Platform |
| Brand | Leica |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Producer |
| Country of Origin | China |
| Model | M80-UVBGR-E |
| Instrument Type | Stereo Fluorescence Microscope |
| Excitation Source | High-Power LED (10 W) |
| Fluorescence Filter Sets | UV (DAPI), B (GFP/FITC), G (Cy3/TRITC), R (mCherry/Cy5) — customizable |
| Filter Configuration | Bandpass, Longpass, and Wideband options available |
| Control Interface | Rotary Knob, Touchscreen Display, or PC Software (RS232/USB protocol support) |
| Light Intensity Memory Function | Yes |
| Cooling Method | Active Air-Cooled Thermal Management |
| Regulatory Status | Not a Medical Device |
| Classification | Research-Grade Fluorescence Imaging System |
| Compliance | Designed for ISO/IEC 17025-aligned laboratory environments |
| Brand | Leica |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic (China-made) |
| Model | Mateo FL |
| Instrument Type | Inverted Fluorescence Microscope |
| Imaging Modes | Fluorescence + Brightfield (Transmitted Light) |
| Dual-Camera System | Integrated Monochrome + Color Cameras |
| AI-Powered Analysis | Confluence Detection, Cell Counting, Transfection Optimization |
| Compliance | FDA 21 CFR Part 11 (Audit Trail, User Management, Electronic Signatures) |
| Sterilization Compatibility | UV, 70% Ethanol, Hydrogen Peroxide (BSL-1/BSL-2 Certified) |
| Onboard Storage | 500 GB (≈3 million images) |
| Barcode & QR Code Integration | Sample Tracking & Mobile Data Transfer |
| Space-Saving Design | Compact Footprint for Laminar Flow Hood Integration |
| Brand | Leica |
|---|---|
| Country of Origin | Germany |
| Instrument Type | Inverted Fluorescence Microscope |
| Excitation Source | LED |
| Objective Options | 63× Water Immersion Objective with Auto-Watering |
| Fluorescence Detection | FluoSync Hyperspectral Unmixing Technology |
| Automation Level | Fully Motorized |
| Focusing Strategy | Three Intelligent Focus Modes (Adaptive, Continuous, and Z-Stack) |
| Observation Interface | Integrated Scientific CMOS Camera |
| DIC Compatibility | Compatible with Glass and Plastic Culture Vessels |
| Stage | Fully Motorized Scanning Stage |
| Filter System | FluoSync Hyperspectral Unmixing for Simultaneous Multi-Channel Acquisition |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | MICA Widefield |
| Instrument Type | Inverted Fluorescence Microscope |
| Excitation Source | High-Power LED |
| Objective Options | 63× Water Immersion Objective (CS2, NA 1.20) with Auto-Water Delivery |
| Fluorescence Detection Technology | FluoSync Hyperspectral Unmixing |
| Control Architecture | Fully Motorized & Software-Driven |
| Focusing Strategy | Three Adaptive Focus Modes (Overview, Detail, Subcellular) |
| Observation Interface | Integrated Scientific CMOS Camera |
| DIC Compatibility | Optimized for Glass and Plastic Culture Vessels |
| Stage | Fully Motorized XY Scanning Stage |
| Filter System | FluoSync-Enabled Spectral Separation Module |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Instrument Type | Research-Grade Inverted/ Upright Integrated Fluorescence Microscope |
| Excitation Source | High-Power LED |
| Configuration | Fully Automated Whole-Organism Imaging Platform with Computational Clearing |
| Optical Architecture | Stereo + Epifluorescence + Z-stack Acquisition Engine |
| Compliance | Designed for ISO/IEC 2382:2015-compliant image clarity and structural fidelity in biological imaging |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | THUNDER Imager Tissue |
| Instrument Type | Upright/Inverted Hybrid Fluorescence Microscope |
| Excitation Source | High-Power LED Illumination |
| Classification | Research-Grade Widefield Fluorescence Microscope |
| Key Technology | Computational Clearing (Real-Time Deconvolution) |
| Optical Architecture | Optimized for 3D Tissue Imaging (up to 200 µm depth) |
| Software Platform | LAS X Navigator with Integrated THUNDER Engine |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Mad City Labs (MCL Think Nano) |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | MicroMirror TIRF System |
| Instrument Type | Inverted Fluorescence Microscope |
| Excitation Source | Metal Halide Lamp |
| Eyepiece Compatibility | Universal Eyepiece Mount |
| Objective Compatibility | Universal Objective Mount |
| Fluorescence Configuration | Integrated Through-Objective Total Internal Reflection Fluorescence (TIRF) |
| Illumination Flexibility | Multi-Source Compatible |
| Observation Head | Monocular, Full-Internal-Reflection Optical Path |
| Brand | Mad City Labs |
|---|---|
| Origin | USA |
| Model | TIRF Module |
| Microscope Type | Inverted Fluorescence Microscope |
| Excitation Source | Metal Halide Lamp |
| Eyepiece | Standard Eyepiece |
| Objective | Standard Objective |
| Fluorescence Configuration | Epi-Fluorescence |
| Compatible Light Sources | Universal (Any Illumination Source) |
| Observation Head | Inverted |
| Illumination Modes | Epi-Fluorescence, Total Internal Reflection Fluorescence (TIRF), Highly Inclined and Laminated Optical (HILO) |
| Beam Steering Precision | Micrometer-Driven Mirror Translation (M2), Axial Lens Adjustment (L1), Fixed-Angle Steering Mirror (M1) |
| Output Coupling | TIRF Lock™ Interface for Z-Axis Feedback Stabilization |
| Compatibility | RM21™ and MicroMirror™ TIRF Platforms |
| Mounting | Modular, Tool-Free Alignment Design |
| Optical Path Control | Full Continuum from 0° (Epi) to >Critical Angle (TIR) |
| Brand | MCL Think Nano |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | RM21™ Microscope Platform |
| Instrument Type | Inverted Fluorescence Microscope |
| Excitation Source | Metal Halide Lamp |
| Eyepiece Compatibility | Standard 23.2 mm or 30 mm Mounts |
| Objective Compatibility | Standard RMS or M25 Thread Mounts |
| Fluorescence Configuration | Epi-illumination (Reflected Light) |
| Illumination Flexibility | Compatible with Broadband, LED, and Laser Sources |
| Observation Geometry | Inverted Optical Layout |
| Z-Axis Travel | 50 mm (2 in) with 95 nm Step Resolution |
| XY Positioning | Manual or Motorized Micropositioner (Optional) |
| Encoder Option | Closed-Loop Encoders Available for X, Y, and Z Axes |
| Integration Ready | Fully Compatible with Nano-Cyte® 3D Stability System, Nano-LPS/Nano-LPQ Linear Positioners, Nano-OP/Nano-F Objective Positioners, and LCC-Focus™ Autofocus Modules |
| Brand | MCL Think Nano |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | TIRF Lock™ |
| Instrument Type | Inverted Fluorescence Microscope Add-on Module |
| Excitation Source | Metal Halide Lamp |
| Eyepiece | Standard |
| Objective | Standard |
| Fluorescence Configuration | Epi-Fluorescence |
| Compatible Light Sources | Any Illumination Source |
| Observation Head | Inverted |
| Wavelength Range | 400–1000 nm |
| Peak Responsivity | 0.4 A/W @ 635 nm, 0.67 A/W @ 900 nm |
| Recommended Input Beam Diameter | 300 µm – 1.5 mm |
| Sensor Active Area | 2.4 mm × 2.4 mm |
| Clear Aperture | 12.5 mm (0.5 inch) |
| Aperture Threading | SM05 (0.535-40) |
| Detector Head Mounting Thread | 8-32 or M4 |
| Base Mounting Thread | 1/4-20 or M6 (magnetic base & clamping fork included) |
| Detector Cable Length | 1.83 m (6 ft) |
| Power Supply | 90–260 V AC |
| Controller Dimensions | 212.7 mm × 88.9 mm × 304.8 mm (8.375″ × 3.5″ × 12″) |
| PC Interface | USB 2.0 |
| OS Compatibility | Windows XP Pro / Vista / 7 / 8 (32- or 64-bit) |
| Brand | Nikon |
|---|---|
| Origin | Japan |
| Model | ECLIPSE Ji |
| Optical System | CFI Infinity Optics |
| Microscope Type | Inverted Fluorescence Microscope |
| Observation Modes | Brightfield & Epi-Fluorescence |
| Field Number | 25 |
| Camera | 7.8 MP Monochrome CMOS Sensor |
| Bit Depth | 12-bit / 8-bit |
| Max Frame Rate | 18 fps |
| Output Resolution | 2800 × 2800 pixels |
| Focus Drive | Motorized PFS (Perfect Focus System) |
| Focus Travel | ~10 mm |
| Max Focus Speed | 2.5 mm/sec |
| PFS Method | Infrared Projection-Based Focus Maintenance |
| Stage Travel (X/Y) | ±59 mm / ±39.5 mm |
| Max Stage Speed | ~25 mm/sec |
| Objective Turret | 6-position, Motorized |
| Filter Cube Capacity | 6 positions (wide-field compatible) |
| Filter Turret Drive | Motorized |
| Light Source | D-LEDI2 LED Fluorescence Illuminator |
| Illumination | Köhler LED Transmitted Light |
| Interface | USB 3.0 (SuperSpeed), USB-B connector |
| Input Voltage | 100–240 VAC ±10%, 50/60 Hz |
| Power Consumption | 320 W |
| Compliance | UL, CE, RoHS |
| Brand | Nikon |
|---|---|
| Origin | Japan |
| Model | ECLIPSE Ti2-A |
| Optical System | CFI60 Infinity-Corrected |
| Intermediate Magnification | 1.0× / 1.5× (field-replaceable to 2.0×) |
| Focus Mechanism | Motorized coarse/fine focus with 10 mm travel, minimum step size: 0.01 µm (encoder-controlled) |
| Condenser | Motorized turret (TI2-C-TC-E) supporting 7 positions (ø37 mm × 4, ø39 mm × 3), including LWD, ELWD, CLWD, HNA dry/oil, and NAMC objectives |
| Stage | Motorized XY stage (TI2-S-SE-E): ±57 mm X, ±36.5 mm Y, max speed 25 mm/s |
| Objective Turret | 6-position motorized nosepiece with Perfect Focus System (PFS) and DIC compatibility |
| Epi-Fluorescence Filter Turret | 6-position motorized filter cube turret (TI2-F-FLT-E) with integrated shutter |
| Illumination | LED-based transmitted illumination (TI2-D-LHLED), optional 100 W halogen or pre-centered D-LH/LC lamp housing |
| Software Integration | Compatible with NIS-Elements AR/VR/CV platforms |
| Environmental Rating | Indoor use only |
| Brand | Nikon |
|---|---|
| Origin | Japan |
| Model | ECLIPSE Ti2-E |
| Type | Inverted Research Microscope with Motorized Precision Optomechanics |
| Optical System | CFI60 Infinity-Corrected, Field Number 22 (Eyepiece), Field Number 16 (Camera Port) |
| Intermediate Magnification | 1.0× / 1.5× (field-upgradable to 2.0×) |
| Focus Drive | Motorized coarse/fine focusing, 10 mm travel, minimum step size 0.01 µm (encoder-controlled) |
| Condenser Turret | Motorized 7-position (TI2-C-TC-E), supporting LWD, ELWD, CLWD, HNA dry/oil, and NAMC objectives |
| Objective Nosepiece | 5-position motorized with Perfect Focus System (PFS) and correction collar control |
| Epi-Fluorescence Filter Turret | 6-position motorized (TI2-F-FLT-E) with integrated shutter |
| Stage | Motorized XY stage (±57 mm X, ±36.5 mm Y), max speed 25 mm/s, magnetic sample holder |
| Illumination | LED-based transmitted illumination (TI2-D-LHLED), optional 100 W halogen or pre-centered D-LH/LC lamp |
| Software Compatibility | NIS-Elements AR/C/VR, supports FDA 21 CFR Part 11 compliance modules, GLP/GMP audit trail logging |
| Brand | Nikon |
|---|---|
| Origin | Japan |
| Model | ECLIPSE Ti2-U |
| Optical System | CFI60 Infinity-Corrected |
| Intermediate Magnification | 1.0× / 1.5× (field-replaceable to 2.0×) |
| Focus Mechanism | Motorized coarse/fine focus with 10 mm travel, minimum step size: 0.01 µm (encoder-controlled) |
| Condenser | Motorized turret (7-position, supports LWD/ELWD/CLWD/HNA/NAMC objectives) |
| Stage | Motorized XY stage (±57 mm X, ±36.5 mm Y, max speed 25 mm/s) |
| Nosepiece | 6-position motorized objective revolver with Perfect Focus System (PFS) and DIC compatibility |
| Epi-Fluorescence Turret | 6-position motorized filter turret with integrated shutter |
| Illumination | LED-based transmitted illumination (TI2-D-LHLED) and fiber-coupled epi-fluorescence modules |
| Environmental Rating | 0–40 °C, ≤60% RH (non-condensing), indoor use only |
| Brand | Nikon |
|---|---|
| Origin | Japan |
| Model | ECLIPSE Ts2 |
| Optical System | CFI60 Infinity-Corrected |
| Observation Modes | Brightfield, Phase Contrast (including Plan Apochromat Phase), DIC-like Relief Contrast*¹ |
| Fluorescence Capability | Yes (Ts2-FL variant) |
| Illumination | High-Brightness White LED Transmitted Light (with Köhler illumination via built-in fly-eye lens) |
| Eyepiece Angle | 45°, Interpupillary Distance: 50–75 mm (Siedentopf), Port Split: 100/0 or 0/100 |
| Focusing Mechanism | Objective Nosepiece Movement (7 mm up / 1.5 mm down), Coarse Focus: 37.7 mm/rev, Fine Focus: 0.2 mm/rev, Adjustable Coarse Focus Torque |
| Objective Turret | 5-Position |
| Condenser | ELWD (NA 0.3, WD 75 mm) |
| Stage | Flat Stage (170 × 247 mm) |
| Dimensions (W×D×H) | 236 × 548 × 471 mm (Ts2), 236 × 564 × 471 mm (Ts2-FL) |
| Weight | ~13 kg (Ts2), ~14.5 kg (Ts2-FL) |
| Power Supply | 100–240 V AC ±10%, 50/60 Hz, 0.35 A |
| Power Consumption | 15 W |
| Brand | Nikon |
|---|---|
| Origin | Japan |
| Model | ECLIPSE Ts2-FL |
| Optical System | CFI60 Infinity-Corrected |
| Observation Modes | Brightfield, Phase Contrast (T-PH), Differential Interference Contrast (DIC)-like Relief Contrast, Epifluorescence |
| Illumination | High-Brightness White LED Transmitted Light + Modular LED Epifluorescence (385, 455, 470, 505, 525, 560, 590, 625 nm) |
| Eyepiece Field Number | 22 (10×), 16 (15×), 12.5 (20×) |
| Tube Angle | 45°, Interpupillary Distance: 50–75 mm (Siedentopf), Trinocular Port (100/0 or 0/100 beam splitter) |
| Focus Travel | 8.5 mm total (7 mm upward, 1.5 mm downward) |
| Coarse Focus | 37.7 mm/rev, Fine Focus: 0.2 mm/rev, Adjustable Coarse Focus Torque |
| Objective Turret | 5-Position |
| Condenser | ELWD (NA 0.3, WD 75 mm) with Pre-centered and Centerable Phase Contrast Sliders (for 10×, 20×, 40×) and Relief Contrast Sliders (dual-side configuration required) |
| Stage | Fixed Plate Stage (170 × 247 mm) with Acrylic Circular Cover Slip |
| Compatible with Multiple Sample Holders | CS-HP35 (35 mm dish), CS-HLP100 (100 mm dish), CS-HT (Terasaki plate & Ø65 mm dish), CS-HS (slide, Ø54 mm dish, hemocytometer), C-S-HU (universal holder for Terasaki, slides, Ø35–65 mm dishes, hemocytometer), C-S-HG (circular glass slide holder), C-S-HLS (circular cover slip kit) |
| Fluorescence Attachment | Motorized Filter Cube Turret (3 positions + brightfield slot), Integrated Noise-Reduction Mechanism, Optional Light Shield |
| Dimensions (W×D×H) | 236 × 548 × 471 mm (Ts2), 236 × 564 × 471 mm (Ts2-FL) |
| Weight | ~13 kg (Ts2), ~14.5 kg (Ts2-FL) |
| Power Supply | 100–240 VAC ±10%, 50/60 Hz, 0.35 A |
| Power Consumption | 15 W |
| Brand | Nikon |
|---|---|
| Origin | Japan |
| Model | ECLIPSE Ts2R |
| Optical System | CFI60 Infinity-Corrected |
| Observation Modes | Brightfield, Phase Contrast (including TMC), DIC, NAMC (Nikon Advanced Modulation Contrast), Relief Contrast, Fluorescence Epi-Illumination, Spindle Observation |
| Illumination | High-Brightness White LED Transmitted Light (with Homogenizing Lens), LED Epi-Illumination (up to 4 interchangeable units |
| wavelengths | 385, 455, 470, 505, 525, 590, 625 nm) |
| Eyepiece Options | 10× (22 mm FOV), 12.5× (16 mm), 15× (14.5 mm) |
| Binocular Tube | Siedentopf-type, interpupillary distance 50–75 mm, tilt angle 35° (standard) or 15–45° (ergonomic) |
| Camera Port Split Ratios | 100:0 / 0:100, 100:0 / 20:80, 100:0 / 50:50 |
| Focus Mechanism | Objective nosepiece-driven Z-movement |
| coarse focus | 5.0 mm/rev, fine focus: 0.1 mm/rev |
| Objective Turret | 6-position, with DIC prism slots |
| Condenser | Rotating condenser turret (7-slot), compatible with ELWD, LWD, and NAMC condensers |
| Stage | Flat stage (260 × 300 mm) |
| Stage Adapters | C-S-HP35 (35 mm dish), C-S-HLP100 (100 mm dish), C-S-HT (Terasaki plates & Ø65 mm dishes), C-S-HS (slide, Ø54 mm dish, hemocytometer), C-S-HU (universal for Terasaki, slides, Ø35–65 mm dishes, hemocytometer), C-S-HG (circular glass slide), C-S-HLS (circular slide kit), TC-S-HA (acrylic stage plate) |
| Fluorescence Accessories | Motorized filter cube turret (body-integrated, noise-reduction design) |
| Dimensions (W×D×H) | 286 × 466 × 542 mm |
| Weight | ~17–18 kg |
| Power Supply | 100–240 V AC, <0.65 A |
| Power Consumption | 30 W |
| Brand | Nikon |
|---|---|
| Origin | Japan |
| Model | ECLIPSE Ts2R-FL |
| Optical System | CFI60 Infinity-Corrected |
| Observation Modes | Brightfield, Phase Contrast (including TIRF-capable phase), DIC, NAMC (Nikon Advanced Modulation Contrast), Relief Contrast, Spindle Observation, Epifluorescence |
| Illumination | High-Intensity White LED Transmitted Light (with Köhler illumination and built-in fly-eye lens) |
| wavelengths | 385, 455, 470, 505, 525, 590, 625 nm) |
| Eyepiece Options | 10×/22, 12.5×/16, 15×/14.5 field number |
| Trinocular Port Split Ratios | 100:0 / 0:100, 100:0 / 20:80, 100:0 / 50:50 |
| Focus Mechanism | Objective nosepiece-driven Z-axis movement (8 mm upward, 3 mm downward travel) |
| coarse focus | 5.0 mm/rev, fine focus: 0.1 mm/rev |
| Nosepiece | 6-position revolver with DIC prism slots |
| Condenser | Multi-position condenser turret (7-slot), compatible with ELWD, LWD, and NAMC condensers |
| Stage | Flat stage (260 × 300 mm) |
| Fluorescence Accessories | Motorized filter cube turret (with noise-reduction mechanism) |
| Dimensions (W×D×H) | 286 × 466 × 542 mm |
| Weight | ~17–18 kg |
| Power Supply | 100–240 V AC, <0.65 A, 30 W max |
| Brand | OLYMPUS |
|---|---|
| Origin | Japan |
| Manufacturer | OLYMPUS Corporation |
| Product Type | Upright Fluorescence Microscope |
| Excitation Source | 100 W Mercury Arc Lamp |
| Illumination | Fiber-Optic Light Guide |
| Observation Head | Trinocular |
| Focus Mechanism | Manual Coarse/Fine Adjustment |
| Stage Type | Fixed Mechanical Stage |
| DIC Capability | Nomarski Differential Interference Contrast (DIC) Enabled |
| Fluorescence Filter Turret | 6-Position Motorized or Manual Turret with Click-Stop Release |
| Objective Mount | WI-SRE3 Swing-Out, U-SLRE Slide-Out, or WI-SNPXLU2 Single-Objective Nosepiece |
| Objective Compatibility | High-NA Water-Immersion (e.g., XLUMPLFLN20xW), XLFLUOR Series (2x/340, 4x/340), and Standard RMS-thread Objectives |
| Condenser Options | Multiple DIC-Compatible Condensers (e.g., U-UCD8) |
| Vibration-Damping Frame | Integrated Anti-Vibration Optical Bench Architecture |
| IR Transmission | Optimized for Near-Infrared (NIR) Imaging up to ~900 nm |
| Compliance | Designed for GLP/GMP-aligned electrophysiology and in vivo imaging workflows |
| Brand | OLYMPUS |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | BX53(LED) |
| Instrument Type | Upright Fluorescence Microscope |
| Excitation Source | High-Intensity LED |
| Instrument Class | Conventional Fluorescence Microscope |
| Objective Options | Multiple X Line Objectives (e.g., 4×, 10×, 20×, 40×, 60×, 100× oil) |
| Fluorescence Modules | Interchangeable Filter Cube Turrets (e.g., FITC, TRITC, DAPI, Cy5) |
| Illumination | 100 W Mercury Arc Lamp (optional), Fiber-Optic Light Guide (optional), Integrated LED Illuminator (standard) |
| Control Mode | Manual and Motorized |
| Focusing Mechanism | Coaxial Fine/Coarse Focus with Motorized Z-Drive Option |
| Condenser Options | U-UCD8, U-LC, U-ULC, U-SC3 |
| Observation Heads | Binocular or Trinocular (with C-mount port) |
| DIC Components | Available as Add-on Module (U-DICR, U-DICB) |
| Stage | Mechanical XY Stage (76 × 52 mm travel), Optional Motorized Stage |
| Fluorescence Filter Sets | Broadband and Narrowband Bandpass Filters, Dichroic Mirrors, Emission Filters (all standardized to ISO 10934-1) |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | BX63 |
| Instrument Type | Upright Fluorescence Microscope |
| Instrument Class | Research-Grade Fluorescence Microscope |
| Objective Turret | Motorized |
| Focus Mechanism | Manual and Motorized |
| Condenser Control | Manual and Motorized |
| Observation Head | Binocular and Trinocular |
| DIC Compatibility | Integrated Differential Interference Contrast (DIC) Module Available |
| Stage | Manual, Mechanical, and Ultrasonic Piezo Motorized XY Stage |
| Fluorescence Filter Sets | Multiple Standard and Customizable Excitation/Emission Filter Combinations |
| Control Interface | Touchscreen Controller with Preset Recall and Workflow Manager |
| Brand | Olympus |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | CX3-Y-E |
| Instrument Type | Upright Fluorescence Microscope Module |
| Excitation Source | High-Efficiency LED |
| Light Output Options | 3 W / 5 W / 10 W |
| Control Interface | Motorized Digital Control |
| Fluorescence Filter Sets Included | DAPI, GFP, FITC, Cy3, TRITC, mCherry, Cy5 (custom filter sets available) |
| Integration | Dedicated optical coupling for Olympus CX33 series microscopes |
| Regulatory Status | Not a Medical Device |
| Compliance | Designed for research-use-only (RUO) applications in accordance with ISO 13485–informed quality practices for laboratory instrumentation |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | IX3-ICSI/IMSI |
| Instrument Type | Inverted Fluorescence Microscope |
| Excitation Source | High-Stability LED Illumination |
| Regulatory Classification | Non-Medical Device |
| Instrument Class | Research-Grade Fluorescence Microscope |
| Eyepieces | Widefield Tilting Binocular, Widefield Binocular (FN 22) |
| Objective Lenses | Interchangeable UIS2 Series with Correction Collars (20×, 40× optimized for dish-bottom thickness) |
| Condenser | Motorized Long-Working-Distance (LWD) Condenser with DIC and Relief Contrast Capabilities |
| Observation Heads | Widefield FN 22 Trinocular or Binocular Configurations |
| DIC Components | Integrated Differential Interference Contrast Module |
| Stage Options | Left-Hand Mechanical Stage, Right-Hand Cross-Stage, Right-Hand Mechanical Stage |
| Compliance | Designed for ISO 13485-aligned laboratory environments |
| Brand | PicoQuant |
|---|---|
| Origin | Germany |
| Model | FluoMic |
| Instrument Type | Upright Fluorescence Microscope |
| Excitation Source | Pulsed and CW Lasers (375–1060 nm) |
| Detection Range | 400–1700 nm |
| Spatial Resolution | ≤2 µm |
| Lifetime Measurement Range | ~ps to ms (TCSPC-based) |
| Focus Mechanism | Motorized |
| Control Interface | SymPhoTime 64 & EasyTau 2 Software |
| Compatible Microscope Stands | Olympus BX43, BX53(-P), BX63, BXFM |
| Scan Options | Optional XY/XYZ piezo stages (75 × 75 mm to 80 × 80 × 80 µm range) |
| TCSPC Electronics | PicoHarp 330 / MultiHarp 150 / TimeHarp 260 Pico |
| Detector Options | PMT (PMA-C), Hybrid PMT (PMA Hybrid), InGaAs SPAD (MPD, Excelitas) |
| Spectral Selection | FlexWave wavelength selector (1–80 nm bandwidth, 0.1 nm step, >80% transmission) |
| Brand | SOPTOP |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | CX40 |
| Instrument Type | Upright Fluorescence Microscope |
| Excitation Source | High-Efficiency Multi-Wavelength LED System (UV/B/G) |
| Illumination | 6V30W Halogen Lamp (Centered, Continuously Adjustable Intensity) |
| Observation Head | Infinity-Corrected Trinocular Hinged Tube (Optional Binocular) |
| Eyepieces | Wide-Field Plan Eyepieces PL10X/22mm with Optional Reticle |
| Objectives | Infinity-Corrected Achromatic (2X–100X), Phase Contrast (10X–100X), and Semi-Apochromatic Fluor (4X–100X) Objective Sets |
| Condenser | Swing-Out Achromatic Condenser, NA 1.2/0.22, Graduated Iris Diaphragm |
| Stage | 175 × 145 mm Right-Hand Dual-Layer Mechanical Stage (76 × 50 mm Travel, 0.1 mm Resolution) |
| Fluorescence Filter Sets | UV1/V1/B1/G1 |
| DIC Compatibility | Built-in DIC Slots in Nosepiece & Condenser |
| Focusing Mechanism | Low-Position Coaxial Coarse/Fine Focus with 1 µm Fine Adjustment Graduation |
| Control Mode | Manual |
| Regulatory Status | Not a Medical Device (Non-CE/IEC 62304, Non-FDA 510(k)) |
| Brand | SOPTOP |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | EX33 |
| Price Range | USD 4,200 – 11,200 |
| Instrument Type | Upright Fluorescence Microscope |
| Excitation Source | High-Power Single-LED (3 W or 5 W) |
| Microscope Class | Conventional Epifluorescence Microscope |
| Eyepieces | Widefield Plan Eyepieces PL10X/20 mm and PL10X/22 mm with Adjustable Diopter and Optional Reticle |
| Objective Lenses | Infinity-Corrected Achromatic Objectives (2X, 4X, 10X, 20X, 40X, 60X, 100X) |
| Fluorescence Illumination | LED-Based Epi-Illumination with Single-Band Excitation |
| Illumination Control | Manual Intensity Adjustment |
| Focusing Mechanism | Coaxial Coarse/Fine Focus with Low-Position Knobs |
| Condenser | NA 1.25 Abbe Condenser with Köhler Illumination Capability |
| Observation Head | 30° Inclined Binocular Head with Interpupillary Adjustment |
| Stage | Dual-Layer Mechanical Stage with Ceramic-Coated Surface, Travel Range 78 mm × 51 mm, X-Axis Precision 0.1 mm (Single-Rail Drive), Dual-Slide Holder |
| Fluorescence Filter Sets | B4, B1, B2, G1, UV4 |
| Brand | SOPTOP |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | ICX41 |
| Instrument Type | Inverted Fluorescence Microscope |
| Excitation Source | High-Efficiency LED (385 nm, 470 nm, 560 nm) |
| Eyepieces | Wide-Field Plan Eyepieces PL10X/22 mm with Adjustable Diopter and Optional Reticle |
| Objectives | Infinity-Corrected Long Working Distance (LWD) Achromatic, Phase Contrast, Fluorescence, Semi-Apochromatic Fluorescence & DIC-Compatible Objectives (4×, 10×, 20×, 40×, 60×) |
| Fluorescence Filter Sets | UV1 (DAPI), B1 (FITC), G1 (TRITC) |
| Transmitted Illumination | Dual-Temperature LED (3000 K / 5000 K) |
| Focus Mechanism | Coaxial Coarse/Fine Adjustment with Low-Position Knobs |
| Condenser | NA 0.3, WD 72 mm, Removable |
| Observation Tube | Trinocular, 45° Inclined, 360° Rotatable Hinged Head, Fixed Eyepiece Tubes, Interpupillary Distance 50–75 mm |
| Stage | Fixed 215 × 250 mm Platform with Optional Mechanical Stage (120 × 80 mm Travel), Petri Dish Holders (Ø35 mm), Slide Holder, Teraseki Holder, Perforated Metal & Glass Stage Plates |
| Filter Wheel | Motorized 4-Position Turret (2 Fluorescence + 1 Brightfield + 1 Open Position) |
| ECO Mode | IR-Sensor-Based Automatic Power Management |
| Compliance | Non-Medical Device (Not FDA 510(k) or CE IVD Certified) |