Food Specialized Instruments
Filter
Showing 241–270 of 796 results
| Brand | G-WON |
|---|---|
| Origin | South Korea |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | GMK-835N |
| Price Range | USD 1,400 – 7,000 |
| Brand | G-WON |
|---|---|
| Origin | South Korea |
| Model | SAM-700S |
| Measurement Principle | Refractive Index (Brix) & Electrical Conductivity (Acidity) |
| Brix Range | 0–35.0% w/w |
| Acidity Range | 0–3.50% (as citric acid) |
| Brix Resolution | 0.1% |
| Acidity Resolution | 0.01% |
| Brix Accuracy | ±0.2% |
| Acidity Accuracy | ±0.05% |
| Temperature Compensation | Automatic (ATC, 10–40 °C) |
| Power Supply | 9 V alkaline battery (1×) |
| Dimensions | 200 × 132 × 62 mm |
| Weight | ~2.0 kg |
| Accessories | Pipette, pipette tips, fruit juice extractor tool, dilution cup, syringe, light-blocking cap, user manual |
| Brand | G-WON |
|---|---|
| Origin | South Korea |
| Model | SAM-706AC |
| Measurement Principle | Conductivity (Acidity), Refractometry (Brix) |
| Brix Range | 0.0–45.0% |
| Acidity Range (as citric acid) | 0.00–3.50% |
| Accuracy | ±0.2% Brix, ±0.05% acidity |
| Resolution | 0.1% Brix, 0.01% acidity |
| Temperature Compensation | Automatic, 5–70 °C |
| Measurement Time | 3 s (Brix), 8 s (acidity) |
| Power Supply | 9 V alkaline battery or AC 220 V/60 Hz |
| Sample Compatibility | Citrus, grape, apple, strawberry, peach, kiwifruit, tomato, plum, cherry, raspberry, mulberry, pomegranate, pineapple, mango, pear, orange, etc. |
| Accessories | 30 mL syringe sampler, filtration unit, pipette with tips, diluent vial, shade hood, anti-theft lock, user manual, AC adapter |
| Brand | G-WON |
|---|---|
| Origin | South Korea |
| Model | SENSE I |
| Measurement Range | 0.0–53.0 %Brix |
| Minimum Resolution | 0.1 %Brix |
| Accuracy | ±0.2 %Brix |
| Automatic Temperature Compensation (ATC) | 5–70 °C |
| Sample Volume | 0.1–0.3 mL |
| Measurement Time | ~3 seconds |
| Power Supply | 1 × 9V alkaline battery |
| Brand | Galvanic |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Monispec-AD |
| Price | Upon Request |
| Accuracy | ±0.1% FS |
| Linearity | ±0.1% FS |
| Repeatability | ±0.1% FS |
| Sensitivity | ±0.1% FS |
| Process Temperature Range | 0–140 °C (customizable up to 200 °C) |
| Process Pressure Range | 0–16 bar (customizable up to 30 bar) |
| Response Time | <1 s |
| Power Supply | 220 V AC or 24 V DC |
| Analog Output | 4–20 mA (loop-powered) |
| Measurement Ranges | Redness (0–8 Lov or 8–20 Lov), Yellowness (0–15 Lov or 15–80 Lov), Chlorophyll Concentration (0–1 ppm, typical range 0–200 ppb) |
| Process Connection | 10–100 mm (½″–4″ NPT or flanged) |
| Brand | Galvanic |
|---|---|
| Origin | Germany |
| Model | MONITEK TA6-FS |
| Instrument Type | Beer-Specific Turbidimeter |
| Application | Laboratory |
| Measurement Principle | Dual-Angle Light Scattering (12° Forward Scatter & 90° Side Scatter) |
| Measurement Range | 0–100 EBC (90°), 0–80 EBC (12°) |
| Sensitivity | 0.01 EBC |
| Repeatability | <1% (optical cell) |
| Measurement Time | ~17 s |
| Temperature Control | Up to 60 °C |
| Power Supply | 230 V AC (115 V AC optional) |
| Power Consumption | 60 VA |
| Interface | RS-232 |
| Dimensions (L×W×H) | 450 × 300 × 300 mm |
| Weight | 9 kg |
| Compliance | Designed for ISO 7027-compliant turbidity measurement in beverage matrices |
| Sample Vessel | Standard beer/beverage bottles (automatically rotated) |
| Automatic Compensation | Bottle surface irregularities, scratches, color, and background chromaticity |
| Brand | Jilin University–Xiaotian’e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | GDYN-106SD |
| Detection Limit | 0.1–3.0 mg/kg |
| Inhibition Rate Range | 0–100% |
| Measurement Accuracy | ±10% |
| Sample Throughput | 6 samples per run |
| Assay Time | ≤13 minutes per batch |
| Compliance Standard | GB/T 5009.199–2003 |
| Display | Backlit LCD with Chinese UI |
| Control System | Embedded MCU with data logging and statistical processing |
| Sample Prep | Integrated dedicated pretreatment kit and single-use reagent cartridges |
| Brand | Jilin University Xiaotian’e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | GDYN-308S |
| Pricing | Available Upon Request |
| Detection Principle | Acetylcholinesterase (AChE) Inhibition Assay |
| Target Analytes | Organophosphorus & Carbamate Pesticides |
| Sample Throughput | 8 samples per run |
| Detection Time | ≤13 minutes per batch |
| Detection Limit | 0.1–3.0 mg/kg |
| Inhibition Rate Range | 0–100% |
| Measurement Accuracy | ±10% (relative to reference standard) |
| Brand | Jida Xiaotian’e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | GDYQ-100M |
| Price Range | USD 4,200 – 7,000 |
| Function Type | Multi-Analyte (Simultaneous Detection of >30 Parameters) |
| Sample Compatibility | Universal for Solid, Semi-Solid, and Liquid Food Matrices |
| Wavelength Range | 400–630 nm |
| Assay Time | 3–20 minutes per test |
| Brand | Jilin University–Xiaotian’e |
|---|---|
| Model | GDYQ-107S |
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | PRC |
| Detection Limit | 25.0 mg/kg |
| Measurement Range | 0.0–2000.0 mg/kg |
| Accuracy | ±5% |
| Analysis Time | ≤35 min per sample |
| Sample Processing | Integrated proprietary pretreatment kit and reagents |
| Brand | Jilin University & Xiaotian’e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | GDYQ-110SH |
| Pricing | Available Upon Request |
| Detection Limit | Stale rice ≥3 years old |
| Measurement Range | 1–3 years storage duration |
| Accuracy | ±5% relative to reference standard methods |
| Brand | Jida Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYQ-201SQ2 |
| Pricing | Available Upon Request |
| Detection Principle | Acetylacetone Colorimetric Method |
| Detection Limit | 1.0 mg/kg |
| Measurement Range | 0.0–100.0 mg/kg |
| Accuracy | ±2% |
| Analysis Time | ≤10 min per sample |
| Display | Backlit LCD with Chinese UI |
| Control System | Embedded Microcontroller |
| Data Functions | Measurement logging, statistical processing, parameter setting, help system, USB/RS232 communication |
| Sample Prep | Dedicated pretreatment kit + single-use reagent cartridges |
| Compliance Basis | Modified GB/T 5009.49 & GB 5009.276 methods |
| Brand | Jida Xiaotian’e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYQ-5000S |
| Function Type | Single-Analyte Dedicated Instrument |
| Sample Type | Sesame Oil Only |
| Detection Time | 20 min |
| Quantification Range | 0.0–100.0% |
| Detection Limit | 3.0% |
| Accuracy | ±2% |
| Brand | Gerber |
|---|---|
| Origin | Switzerland |
| Model | Cryoscope C1 |
| Measurement Range | 0 to −1000 m°C/m°H |
| Display Resolution | 0.1 m°C/m°H |
| Repeatability | ±2 m°C/m°H (1S.D.) |
| Sample Volume | 2.0–2.5 mL |
| Measurement Time | ~90 s (Rapid Mode: ~30 s) |
| Operating Ambient Temperature | 15–35 °C |
| Relative Humidity | 5–80 % RH |
| Power Supply | 110–240 V, 50/60 Hz |
| Power Consumption | 90 W |
| Dimensions (W×D×H) | 28 × 42 × 32 cm |
| Net Weight | 11 kg |
| Gross Weight | 15 kg |
| Brand | GERBER |
|---|---|
| Origin | Germany |
| Model | CryoStar Automatic |
| Accuracy | ±0.0001 °C |
| Repeatability | ±0.002 °C |
| Measurement Range | −1.5000 °C to 0.0000 °C |
| Sample Volume | 2.0–2.5 mL |
| Throughput | 40 samples/hour |
| Dimensions (W×H×D) | 44×44×20 cm |
| Test Head Height | 24 cm |
| Net Weight | 14.6 kg |
| Power Supply | 230 V, 50–60 Hz, 180 W + 12 V DC |
| Interface | RS232 |
| Sample Capacity | 12-position automated carousel |
| Compliance | ISO/DIS 5764 |
| Brand | Gerber |
|---|---|
| Origin | Germany |
| Model | CryoStar I |
| Measurement Range | 0.000 to −1.5000 °C |
| Accuracy | ±0.0001 °C (0.1 m°C) |
| Repeatability | ±0.002 °C |
| Sample Throughput | up to 40 samples/hour (typ. 30/h) |
| Sample Volume | 2.0–2.5 mL |
| Cooling Time to Operating Temperature | ≤15 min |
| Display | Full-color LCD touchscreen |
| Data Output | Ice point curve, ice point value, water adulteration %, timestamp, operator ID, calibration status, error codes |
| Interfaces | RS232, dual USB ports (U-drive data export supported) |
| Power Supply | 220 V / 50 Hz, 180 W |
| Dimensions (W×D×H) | 29 × 33 × 34 cm |
| Weight | 8.7 kg |
| Brand | GERBER |
|---|---|
| Origin | Germany |
| Model | CryoStar I |
| Measurement Range | 0.0000 to −1.5000 °C |
| Resolution | 0.0001 °C (0.1 m°C) |
| Accuracy | ±0.002 °C (repeatability) |
| Sample Volume | 2.0–2.5 mL |
| Throughput | up to 40 samples/hour (typical: 30 samples/hour) |
| Cooling Time | ≤15 min to operational temperature |
| Display | Full-color LCD touchscreen |
| Data Interfaces | RS232, 2× USB (U-disk data export) |
| Power Supply | 220 V / 50 Hz, 180 W |
| Dimensions | 29 × 33 × 34 cm |
| Weight | 8.7 kg |
| Brand | GERBER |
|---|---|
| Origin | Germany |
| Model | CryoStar I |
| Measurement Range | 0.000 to −1.5000 °C |
| Resolution | 0.0001 °C (0.1 m°C) |
| Repeatability | ±0.002 °C |
| Sample Throughput | up to 40 samples/hour (typical: 30 samples/hour) |
| Sample Volume | 2.0–2.5 mL |
| Cooling Time to Operating Temperature | ≤15 min |
| Display | Full-color LCD touchscreen |
| Data Output | Ice-point curve, ice-point value, water adulteration percentage, timestamp, operator ID, calibration status, error codes |
| Interfaces | RS232, two USB ports (U-disk data export supported) |
| Power Supply | 220 V / 50 Hz, 180 W |
| Dimensions (W×D×H) | 29 × 33 × 34 cm |
| Weight | 8.7 kg |
| Brand | Funke |
|---|---|
| Origin | Germany |
| Model | CryoStar |
| Measurement Range | 0.000 to −1.5000 °C |
| Accuracy | ±0.0001 °C |
| Repeatability | ±0.002 °C |
| Sample Throughput | 40 samples/hour |
| Sample Volume | 2.0–2.5 mL |
| Display | Color LCD with graphical interface |
| Output | Ice point curve, ice point value (°C), water adulteration percentage, timestamp, date |
| Interfaces | RS-232 serial port, parallel printer port |
| Power Supply | 220 V / 50 Hz, 180 W |
| Dimensions | 29 × 38 × 24 cm |
| Weight | 12 kg |
| Compliance | AOAC Official Method 972.16, GB 5413.38–2016 |
| Brand | Gerber |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | FermentoFlash |
| Instrument Type | Beer-Specific Analyzer |
| Application | Laboratory Use |
| Analysis Time | ≤2 min (including sample loading) |
| Alcohol Content Range | 0.00–15.00 % v/v |
| Apparent Extract Range | 0.00–10.00 % w/w |
| Original Wort Range | 0.00–20.00 % w/w |
| Alcohol Extraction Range | 0.00–10.00 % w/w |
| Repeatability (Alcohol) | ±0.02 % v/v |
| Repeatability (Extract & Original Wort) | ±0.04 % w/w |
| Dimensions (W × H × D) | 30 × 24 × 33 cm |
| Weight | 5 kg |
| pH Measurement | Not applicable — device does not measure pH (parameter misattributed in source |
| Brand | GERBER |
|---|---|
| Origin | Germany |
| Model | Flash |
| Instrument Type | Beer-Specific Analyzer |
| Application | Laboratory |
| Throughput | 40 samples/hour |
| Alcohol Content Range | 0–15% v/v |
| pH Range | 0–15 |
| Dimensions (W×H×D) | 40 × 20 × 26 cm |
| Weight | 10 kg |
| Sample Volume | 18 mL |
| Measurement Accuracy | ±0.01% for alcohol and extract parameters |
| Interface | RS-232 standard port |
| Data Output | Printer-compatible, PC-integrated |
| Brand | Gerber |
|---|---|
| Origin | Germany |
| Model | LactoFlash |
| Automation | Fully Automatic |
| Analysis Speed | 120 samples/hour |
| Measurement Range | Fat 0.01–30.00% |
| Density | ≥0.0001 g/cm³ resolution |
| Freezing Point Depression | ±0.001 °C resolution |
| Repeatability | ±0.02–±0.2% depending on analyte and concentration range |
| Accuracy | ±0.01% for fat, protein, lactose, and non-fat solids |
| Sample Volume | 12–20 mL (adjustable) |
| Power Supply | 230 V / 115 V, 50/60 Hz, 60 W |
| Dimensions | 30 × 24 × 33 cm (W×H×D) |
| Weight | 5 kg |
| Interface | RS-232 serial port |
| Compliance | Designed to support ISO 9001-aligned QA workflows and routine GLP-compliant dairy testing |
| Brand | Gerber |
|---|---|
| Origin | Germany |
| Model | LactoStar |
| Automation | Fully Automatic |
| Analysis Speed | ≥40 samples/hour |
| Measurement Range | Fat 0–35%, Protein 0–10%, Lactose 0–10%, Non-Fat Solids 0–15%, Minerals 0–5%, Freezing Point Depression –0.001 °C |
| Repeatability | ±0.002% (w/w) |
| Accuracy | ±0.001% (w/w) |
| Sample Volume | 12 mL |
| Calibration Storage | Up to 20 user-defined calibration profiles |
| Interface | RS-232 serial port |
| Data Output | Integrated thermal printer support |
| Brand | GERBER |
|---|---|
| Origin | Germany |
| Model | Nova Safety |
| Max Speed | 1350 rpm |
| Relative Centrifugal Acceleration (RCF) | 350 × g |
| Capacity | 8 tubes |
| Temperature Control | 65 °C (heated) |
| Timer | Digital display |
| Safety Features | Automatic lid lock, electronic brake (<8 s stop time) |
| Dimensions (L×W×H) | 470 × 380 × 230 mm |
| Weight | 13.2 kg |
| Voltage | 230 V, 50 Hz |
| Power | 450 W |
| Brand | GERBER |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NOVA-SAFETY |
| Speed | 1350 rpm |
| Relative Centrifugal Acceleration (RCF) | 350 × g |
| Heating Temperature Control | 65 °C ± 1 °C |
| Capacity | 8 tubes (10–12 mL Gerber-specific centrifuge tubes) |
| Safety Lock | Automatic lid interlock with force-sensing engagement |
| Brake Time | < 8 s after rotor stop command |
| Timer | Digital, adjustable 0–30 min in 1-sec increments |
| Compliance | Designed to meet ASTM D943, ISO 1735, and IDF Standard 102 for Gerber fat determination |
| Brand | Gerber |
|---|---|
| Origin | Germany |
| Model | SEDILAB-E |
| Application | Milk and Dairy Product Sediment Analysis |
| Automation Level | Fully Automatic |
| Sample Throughput | 800 samples/hour |
| Sample Volume per Test | 500 mL |
| Sediment Disc Diameter | 32 mm |
| Repeatability | Grade-based Classification (per ISO 707 & IDF 50) |
| Compliance | Designed for ISO, IDF, and national dairy quality standards |
| Brand | GERBER |
|---|---|
| Origin | Germany |
| Model | Solution Index Mixer |
| Motor Speed | 2800 rpm (drive), 3600 rpm (impeller) |
| Impeller | 16-blade stainless steel, clockwise rotation, flat side down, upward tilt from right to left |
| Vessel | 500 mL borosilicate glass beaker |
| Standards Compliance | ADPI, DLG, DIN ISO 8156 |
| Dimensions | 38 × 26 × 25 cm |
| Power | 65 W (220 V, 50 Hz) |
| Brand | GERBER |
|---|---|
| Origin | Germany |
| Model | Super-Vario-N |
| Max Speed | 1130 rpm |
| Speed Adjustment | 10 rpm increments (600–1130 rpm) |
| Heating Range | Ambient to 68 °C (1 °C increments) |
| Timer Range | 1–99 min |
| Chamber Material | Stainless steel |
| Safety Features | Automatic lid lock and brake system |
| Sample Capacity | 12 samples per run (Schmidt-Lewandowsky / solubility method) |
| Compliance | Designed for Gerber, Mojonnier, Babcock, and solubility fat determination methods |
| Brand | Gerber |
|---|---|
| Origin | Germany |
| Model | SUPER-VARIO-N |
| Max Speed | 1130 rpm |
| Speed Adjustment | 10 rpm increments (600–1130 rpm) |
| Heating Range | Ambient to 68 °C (1 °C increments) |
| Timer Range | 1–99 min |
| Chamber Material | Stainless Steel |
| Safety Features | Automatic lid lock and brake system |
| Sample Capacity | 12 positions for Mojonnier and solubility methods |
| Compliance | Designed for ASTM D129, ISO 1735, IDF 14, and AOAC 923.04 dairy fat determination protocols |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Supervario-N |
| Quotation | Upon Request |
| Rotational Speed | 600–1100 rpm |
| Temperature Range | Ambient to 68 °C |
| Centrifugation Time | 1–99 min |
| Construction | Stainless Steel Housing |
| Safety Features | Automatic Lid Lock, Imbalance Detection & Auto-Stop, Motor Brake System |
| Power Supply | 220 V / 50 Hz, 1200 W |
| Dimensions (W × D × H) | 46 × 38 × 38 cm |
| Net Weight | 26 kg |
