| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | MycoFoss |
| Detection Principle | Bead-based Flow Cytometric Immunoassay |
| Sample Throughput | Up to 12 samples per run |
| Assay Time | ≤8 minutes per sample |
| Target Analytes | Aflatoxins (AFB1, AFB2, AFG1, AFG2), Deoxynivalenol (DON), Zearalenone (ZEA), Ochratoxin A (OTA), T-2 Toxin, Fumonisins (FB1, FB2, FB3) |
| Sample Types | Ground corn, wheat, and barley |
| Automation Level | Fully automated sample preparation, assay execution, and data reporting |
| Compliance Support | Audit-trail enabled, 21 CFR Part 11–ready software architecture, GLP/GMP-aligned workflow design |
| Data Management | Integrated instrument control, result traceability, PDF report generation, and CSV export |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | Alphatec™ FNO |
| Application | Falling Number determination per ISO 3093, AACC 56-81B, ICC 107/1, and ASTM D7827 |
| Sample Types | Wheat, Rye, Barley, Sorghum, Flour, and other cereal-based materials |
| Measurement Principle | Viscosity-based enzymatic hydrolysis of starch gel under standardized boiling conditions |
| Display | 7-inch capacitive touchscreen interface with multilingual OS support |
| Compliance | Fully aligned with GLP/GMP data integrity requirements |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | ProFoss™ 2 |
| Automation | Fully Automatic |
| Analysis Time | 3–15 seconds per sample |
| Wavelength Range | 850–1050 nm |
| Wavelength Accuracy | < 0.5 nm |
| Wavelength Precision | < 0.02 nm |
| Wavelength Stability | < 0.01 nm/°C |
| Detector | Silicon Diode Array |
| Spectral Resolution | 1.0 nm/pixel |
| Light Source Lifetime | Dual Lamp System = 17,500 h |
| Environmental Rating | IP69K |
| Operating Temperature | –5 to 40 °C |
| Enclosure Material | Stainless Steel EN 1.4301 (SS2333) |
| Dimensions (W × H × D) | 42 × 42 × 13.5 cm |
| Weight | 25 kg |
| Communication Interfaces | Ethernet, OPC UA, 4–20 mA, PROFIBUS, RINA |
| Power Supply | 100–240 VAC, 50–60 Hz, 2.0 A, 150 W |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | Infratec™ Sofia |
| Instrument Type | Portable Near-Infrared Spectrometer |
| Wavelength Range | 850–1050 nm |
| Measurement Mode | Transmission NIR |
| Analysis Time | ~3 minutes for 10 subsamples |
| Dimensions (W × D × H) | 255 × 390 × 295 mm |
| Weight | 9 kg |
| Operating Temperature | 0–45 °C |
| Storage Temperature | −20–70 °C |
| Relative Humidity | <93% RH (non-condensing), up to 100% cyclic |
| Power Supply | 100–240 V AC, 50–60 Hz, Class I with earth grounding |
| EMC Environment | Light industrial, agricultural & mobile machinery |
| Sample Preparation | None required (whole-grain analysis) |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | MeatScan |
| Instrument Type | Laboratory NIR Spectrometer |
| Principle | Grating-based non-scanning array detector |
| Wavelength Range | 850–1050 nm |
| Scan Time | 45 seconds per sample (including 15 subsamples) |
| Data Sampling Interval | 1 nm |
| Measurement Mode | Transmission |
| Chemometrics Software | Artificial Neural Network (ANN)-based calibration |
| Sample Form | Homogenized meat mince (pork, poultry, beef, lamb) |
| Output Parameters | Fat content (%), Moisture content (%) |
| Weight | 12 kg |
| Compliance | Designed for GLP-compliant environments |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | FOSS Kjeltec™ 9 Kjeldahl Nitrogen Analyzer |
| Pricing | Available Upon Request |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | MeatMaster II |
| Technology | X-ray Transmission |
| Sample Types | Raw, chilled, or frozen meat (bone-in or boneless |
| Detection Parameters | Fat content, mass, foreign object detection (metal, bone) |
| Compliance | Designed for food processing environments meeting EU Hygiene Regulation (EC) No. 852/2004, HACCP principles, and compatible with GMP/GLP-aligned QA workflows |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | NIRS™ DS2500 L |
| Instrument Type | Laboratory |
| Principle | Grating Scanning |
| Wavelength Range | 400–2500 nm |
| Scan Time | <40 s per sample |
| Data Sampling Interval | 10 s |
| Measurement Mode | Transmission (for liquids) |
| Chemometrics Software | WinISI |
| IP Rating | IP54 |
| Temperature Control | Automatic, Closed-Loop Sample Thermal Regulation |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | DairyScan |
| Automation | Fully Automatic |
| Analysis Time | 45 seconds per sample (15 sub-samples per run) |
| Measurement Range | Fat 0–36% w/w |
| Repeatability | ≤0.25% CV |
| Accuracy | ≤1.0% CV |
| Detection Principle | Near-Infrared (NIR) Transmission Spectroscopy |
| Sample Throughput | Up to 80 samples/hour (typical operational rate) |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | Soxtec 8000 |
| Extraction Chamber Volume | 65 mL |
| Receiver Flask Capacity | 40–110 mL |
| Temperature Range | 0–285 °C |
| Temperature Control Accuracy | ±1% |
| Throughput | 6 or 12 samples per batch |
| Solvent Recovery Efficiency | up to 80% |
| Safety Features | Automatic solvent leak detection, auto-empty alert for recovery tank, self-diagnostic startup sequence |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | Kjeltec™ 9 Distillator |
| Instrument Type | Kjeldahl Nitrogen Distillation Unit |
| Automation Level | Semi-Automatic |
| Nitrogen Determination Range | 0.1–210 mg N |
| Distillation Time | 3.5 min |
| Repeatability | ±1% RSD |
| Sample Weight Capacity | Solids: 0.2–2 g |
| Semi-solids | 2–5 g |
| Liquids | 10–25 g |
| Nitrogen Recovery Rate | >99.5% |
| Power Rating | 3000 W |
| Dimensions (L×W×H) | 500×480×790 mm |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | WineScan |
| Application Modes | Laboratory & Online-ready |
| Analysis Time | 30 seconds per sample |
| Alcohol Content Range | 0.01–0.4 % vol |
| pH Range | 2.8–3.9 |
| Dimensions (L × W × H) | 62 × 33 × 59 cm |
| Instrument Weight | 89 kg |
| Measurement Principle | Fourier Transform Infrared (FTIR) Spectroscopy |
| Key Parameters | Density, pH, Total Acidity, Reducing Sugars, Dry Extract, Brix, Ethanol, Volatile Acidity, Malic Acid, Lactic Acid, Tartaric Acid, Free SO₂ (optional), Residual Sugar, Acetic Acid, Glucose, Fructose, Glycerol, Citric Acid, Sorbic Acid, Methanol (method-dependent) |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | Fossomatic 7 |
| Automation Level | Fully Automatic |
| Analysis Speed | Up to 600 samples/hour |
| Detection Range | 0–10 × 10⁶ cells/mL |
| Repeatability | CV < 4% at 500,000 cells/mL |
| Accuracy | < 10% deviation vs. direct microscopic count |
| Technology | Flow Cytometry |
| Compliance | ISO 13366-1, IDF 148, FDA/NCIMS Grade A Standards |
| Software Platform | Foss Integrator NOVA |
| Sample Types | Bovine, ovine, caprine, and buffalo milk |
| Configuration Options | Fossomatic 7 (total SCC) and Fossomatic 7 DC (somatic cell differential counting) |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | ProFoss™ 2 Online Soybean Meal Analyzer |
| Instrument Type | Online Near-Infrared Spectrometer |
| Principle | Grating-based diode array (non-scanning) NIR spectroscopy |
| Wavelength Range | 1100–1650 nm |
| Analysis Time per Result | 2–3 seconds (real-time) |
| Sampling Mode | Diffuse reflectance and/or transmission |
| Chemometrics Software | ISIscan NOVA™ Instrument Control |
| Data Acquisition Interval | 2–3 seconds (real-time) |
| Compliance Ready | Designed for integration with industrial process control systems (OPC UA/DA), supports audit-ready data logging per GLP/GMP-aligned workflows |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | CombiFoss 7 |
| Automation Level | Fully Automatic |
| Analysis Throughput | 600 samples/hour |
| Somatic Cell Count (SCC) Range | 0–10 × 10⁶ cells/mL |
| Repeatability | < 2% CV |
| Accuracy | ±0.1–1.5 × 10⁶ cells/mL |
| Sample Temperature Range | 30–42 °C |
| Regulatory Compliance | Designed for ISO 8570, IDF 141, AOAC 991.19, and EU Regulation (EC) No 853/2004 compliance |
| Detection Capabilities | Fat, Protein, True Protein, Lactose, Total Solids, Non-Fat Solids, Urea, Citric Acid, Freezing Point, Casein, Free Fatty Acids, pH, Monounsaturated Fatty Acids (MUFA), Polyunsaturated Fatty Acids (PUFA), Total Unsaturated Fatty Acids, Total Saturated Fatty Acids, Sample Inlet Temperature, Somatic Cell Count (with FM FC module) |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | Fibertec™ 1023 |
| Application Principle | Enzymatic-gravimetric method per AOAC 991.43, AOAC 2009.01, AACC 32–07, NMKL 158, and ASP methods |
| Sample Capacity | 12 samples per digestion batch, 6 samples per filtration batch |
| Digestion Vessel Volume | 600 mL |
| Water Bath Temperature Range | Ambient to 80 °C |
| Temperature Accuracy | ±0.1 °C |
| Oscillation Speed | 0–150 cycles/min |
| Oscillation Amplitude | 0–50 mm |
| Filtration Throughput | 2–4 min per 100 mL digested slurry |
| Reproducibility | RSD < 0.5% for total dietary fiber (TDF) across replicate analyses |
| Compliance | Fully aligned with AOAC Official Methods of Analysis®, ISO 13905:2014, and USP <2040> for dietary fiber quantification |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | OenoFoss 2 |
| Application Modes | Laboratory & At-line |
| Analysis Time | ≤2 min |
| Alcohol Content | 0.5–19 % vol. |
| pH Range | 2.6–4.0 |
| Dimensions (L×W×H) | 189 × 154 × 321 mm |
| Weight | 6.3 kg |
| Sample Volume | 600 µL |
| Operating Temperature | 10–35 °C |
| Detection Principle | Fourier Transform Infrared (FT-IR) Spectroscopy |
| Parameters Measured | Ethanol, Glucose, Fructose, pH, Total Acidity, Volatile Acidity, Malic Acid, Sugar Content (°Brix), Color Intensity |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | Milkoscan Mars |
| Automation | Fully Automatic |
| Analysis Time | 1 min per sample |
| Measurement Parameters | Fat, Protein, Lactose, Total Solids, Non-Fat Solids |
| Repeatability | ≤0.5% CV (for raw milk major components) |
| Accuracy | ≤1.2% CV (for raw milk major components) |
| Technology | Fourier Transform Infrared (FTIR) Spectroscopy |
| Compliance | Designed for ISO 9001–certified dairy QA/QC environments |
| Screening Capability | Pre-installed ASM (Adulterant Screening Module) models for urea, sucrose, formaldehyde, sodium bicarbonate, potassium nitrate, and other common adulterants |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | NIRS DS3 F |
| Instrument Type | Laboratory NIR Spectrometer |
| Optical Principle | Grating Scanning |
| Wavelength Range | 850–2500 nm |
| Scan Speed | <1 minute per sample |
| Data Sampling Interval | 0.5 nm |
| Measurement Mode | Diffuse Reflectance / Transflectance |
| Chemometrics Software | WinISI with Artificial Neural Network (ANN) algorithms |
| Enclosure Rating | IP65 |
| Cooling System | Closed-Loop Liquid Cooling |
| Sample Interface | RFID-Enabled Sample Cups |
| Factory Calibration Strategy | Pre-Standardized, Inter-Instrument Transferable Calibration |
| Language Options | English or Chinese UI & Network Management Software |
| Compliance Support | ASTM E1655, ISO 12099, USP <857>, GLP/GMP-ready audit trail capabilities in WinISI |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | Infratec Nova |
| Instrument Type | Benchtop |
| Analysis Time | 40 s |
| Sample Mass | 5 g |
| Scan Speed | 10 s |
| Wavelength Range | 1100 nm |
| Sample Form | Whole grain or milled flour, no preparation required |
| Calibration Basis | Artificial Neural Network (ANN) with >50,000 reference samples |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Instrument Type | Kjeldahl Nitrogen Determinator |
| Automation Level | Fully Automated |
| Nitrogen Determination Range | 0.1 – 210 mg N |
| Distillation Flow Rate | ~40 mL/min |
| Repeatability | ≤1% RSD |
| Recovery Rate | >99.5% (for 1–200 mg N) |
| Power Consumption | 3000 W |
| Dimensions (L×W×H) | 500 mm × 480 mm × 760 mm |
| Brand | FOSS |
|---|---|
| Origin | Jiangsu, China |
| Instrument Type | Automated Kjeldahl Nitrogen Determinator |
| Automation Level | Fully Automated |
| Model | SINO KT8400 |
| Compliance Standards | AOAC, EPA, DIN, ISO |
| Sample Throughput | Compatible with 20-position autosamplers (e.g., FOSS 8420/8460) |
| Safety Features | SAFE™ steam-controlled distillation, interlocked transparent safety door, integrated temperature-controlled distillate cooling |
| Software Options | FOSS Compass LIMS-ready software with GLP-compliant audit trail, network printer/tare balance integration |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | CT 293 |
| Instrument Type | Cyclonic Grinder |
| Sample Applicability | Hard, brittle, and fibrous materials (e.g., cereals, seeds, feed, leaves, tablets, tobacco, limestone, coal) |
| Feed Size | ≤10 mm (standard inlet), up to 40 mm (optional large inlet) |
| Output Particle Size | 0.01–0.5 mm |
| Particle Distribution | ≥95% retained on 1 mm sieve |
| Rotational Speed | 10,000 rpm |
| Grinding Rate | ~4 g/s |
| Noise Level | <75 dB(A) |
| Compliance | AOAC Official Method 995.13 |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | KN295 |
| Instrument Type | Knife Mill |
| Sample Applicability | Hard, High-Fat, High-Moisture & High-Fiber Materials |
| Feed Size | <15 mm |
| Output Particle Size | 3–4 mm (pre-grinding) |
| Batch Capacity | 100 mL (50–150 g) |
| Rotational Speed | 20,000 rpm |
| Cooling | Integrated Tap-Water or Lab-Cooled Water Circulation System |
| Safety | Interlocked Lid Switch (halts rotation within 1 s) |