| Brand | ARA |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | FTS |
| Pricing | Available Upon Request |
| Enclosure Dimensions | 10.62" × 9.68" × 4.87" (27 cm × 24.6 cm × 12.4 cm) |
| Weight | 5 lbs (2.27 kg) |
| Flow Ranges | 1–3 LPM, 2–9 LPM, 9–25 LPM |
| Flow Accuracy | ±1% of reading |
| Temperature Range | −30°C to +50°C |
| Temperature Accuracy | ±0.5°C |
| Barometric Pressure Range | 250–800 mmHg |
| Pressure Accuracy | ±5 mmHg |
| Battery | Rechargeable NiMH |
| Runtime | Up to 60 hours |
| Brand | ARA |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | LFR-6 |
| Weight | 15 lb |
| Flow Rate | 6 L/min (adjustable 3–10 L/min) |
| Flow Accuracy | ±2% |
| Battery | 18 V Li-ion (rechargeable, 1 hr charge time, >30 hr runtime) |
| Data Logging Interval | 5 min |
| Dimensions | 10" × 12" × 7" |
| Data Export | USB flash drive |
| Filter Format | 47 mm FRM-compatible |
| Sampling Modes | TSP, PM₁₀, PM₂.₅ |
| Optional Sensors | Real-time particulate (RTP), PEET anemometer, optical scattering sensor |
| Compliance | Designed to meet U.S. EPA Reference Method (FRM) criteria for low-flow ambient particulate monitoring |
| Brand | ARA |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | LFR-6 |
| Weight | 15 lb |
| Flow Rate Range | 3–10 L/min |
| Nominal Flow Rate | 6 L/min |
| Flow Accuracy | ±2% |
| Battery | 18 V Li-ion (rechargeable) |
| Charge Time | 1 h |
| Runtime | >30 h |
| Data Logging Interval | 5 min |
| Dimensions (L×W×H) | 10" × 12" × 7" |
| Shipping Weight | 25 lb |
| Filter Format | 47 mm FRM-compatible |
| Sampling Modes | TSP, PM₁₀, PM₂.₅ |
| Optional Sensors | Real-Time Particle (RTP) Sensor, PEET Anemometer, Optical Scattering Dust Monitor |
| Data Export | USB Flash Drive |
| Compliance | Designed to meet EPA Reference Method (FRM) criteria for low-flow particulate sampling |
| Brand | ARA |
|---|---|
| Origin | USA |
| Model | N-FRM |
| Flow Rate | 10–20 LPM (nominal 16.7 LPM) |
| Flow Accuracy | ±2% (±1% with calibration) |
| Operating Time | >30 hours on rechargeable 18 V lithium battery |
| Charging Time | 1 hour |
| Data Output | USB flash drive |
| Dimensions | 25.4 × 30.48 × 17.78 cm |
| Sampling Weight | 15 lbs |
| Shipping Weight | 25 lbs |
| Filter Holder | Standard FRM-compliant 47 mm cassette mount |
| Particle Separation | Low-maintenance, oil-free cyclonic inlet for PM₂.₅ and PM₁₀ |
| Brand | ARA |
|---|---|
| Origin | USA |
| Model | N-FRM |
| Flow Rate | 10–20 LPM (nominal 16.7 LPM) |
| Flow Accuracy | ±2% (±1% with calibration) |
| Operating Time | >30 hours on rechargeable 18 V lithium battery |
| Charging Time | 1 hour |
| Data Output | USB flash drive interface |
| Dimensions | 25.4 × 30.48 × 17.78 cm |
| Sampling Weight | 15 lbs |
| Shipping Weight | 25 lbs |
| Filter Holder | Standard FRM-compliant 47 mm cassette mount |
| Particle Separation | Low-maintenance, oil-free cyclonic inlet for PM₂.₅ and PM₁₀ |
| Brand | Argonaut |
|---|---|
| Origin | Canada |
| Model | MISG01 |
| Particle Type | Combustion-generated carbon black aerosol |
| Primary Particle Size Range | 20–700 nm (flow-dependent) |
| Number Concentration | Up to 10⁷ particles/cm³ (undiluted) |
| Soot Mass Output | ~100 mg/h |
| Fuel Gas Options | Ethylene, propane, ethane, or methane/nitrogen blends |
| Fuel Flow Rate | 0.06–0.13 L/min |
| Oxidizer/Dilution Air Flow Rate | 7–10 L/min |
| Operating Environment | Ambient temperature |
| Brand | Aria |
|---|---|
| Origin | Japan |
| Model | AP133 / AP136 |
| Instrument Type | Handheld Particle Counter |
| Flow Rate | Low-flow (2.83 L/min) |
| Flow Accuracy | ≤ ±5% |
| Timing Accuracy | ≤ ±1 s per 6-min sampling |
| Repeatability | ≤ ±10% FS |
| Size Distribution Error | ≤ ±30% |
| Indication Error | ≤ ±30% FS |
| Channel Count | 3 or 6 channels |
| Particle Size Range | 0.3–5.0 μm (AP133) / 0.3–10.0 μm (AP136) |
| Counting Efficiency | 50% at 0.3 μm, ≥99% at ≥0.45 μm (compliant with ISO 21501-4 & JIS B 9921) |
| Zero Count Level | <1 count per 5 minutes (ISO 21501-4 compliant) |
| Max. Concentration | 4×10⁶ particles/m³ (5% counting loss), up to 2.1×10⁸ particles/m³ with correction |
| Laser Source | Long-life laser diode |
| Resolution at 0.5 � | m: <15% (ISO 21501-4) |
| Sampling Modes | Manual, Auto, ISO-compliant (ISO 14644-1), GMP-compliant (EU Annex 1), Accumulative/Differential, Count/Concentration |
| Sampling Time | 1 s – 2 h (configurable) |
| Hold Time | 0 s – 2 h (configurable) |
| Sampling Cycles | 1–9999 (AP136) / 1–2000 (AP133) or continuous |
| Sampling Points | 1–100 |
| Room ID | 0–99 |
| Delay Start | 10 s (Manual/Auto), 1 min – 2 h (ISO/GMP) |
| Internal Filter | High-efficiency air filter |
| Pump | Integrated diaphragm pump |
| Communication Interfaces | LAN (RJ45), Bluetooth Low Energy (BLE), USB-B, USB-C |
| Remote Control | Ethernet & BLE |
| Data Storage | 15,000 records (AP136) / 10,000 records (AP133) |
| Security | Password-protected login |
| Alarms | Audible particle count alarm, low battery, flow fault, laser fault |
| Display | Resistive touch screen + single physical button |
| Power Supply | AC adapter (100–240 VAC, output 5 V / 3 A) |
| Battery | Li-ion (5000 mAh), ~4 h continuous operation |
| Charging Time | ~4.5 h |
| Dimensions (main unit) | H 19.7 × W 9.2 × D 4.8 cm |
| Probe length | ~3 cm |
| Weight | ~810 g |
| Operating Environment | 5–35 °C, 20–95% RH (non-condensing) |
| Storage | −20–50 °C, ≤98% RH (non-condensing) |
| Warranty | 2 years |
| Standard Accessories | AC adapter, USB cable, zero-count filter, remote measurement software, calibration certificate, carrying case |
| Optional Accessories | Temperature & relative humidity probe (0–50 °C, ±0.5 °C |
| Compliance | ISO 21501-4, JIS B 9921, ISO 14644-1, EU GMP Annex 1 (Grade A–D static/dynamic), USP <788>, FDA 21 CFR Part 11 (audit trail enabled via PC software) |
| Brand | Aria |
|---|---|
| Origin | Japan |
| Model | APS100 Series |
| Flow Rate | 2.83 L/min (1 CFM) ±5% |
| Timing Accuracy | ≤±1 s over 6-min sampling |
| Repeatability | ≤±10% FS |
| Particle Size Distribution Error | ≤±30% |
| Indication Error | ≤±30% FS |
| Counting Efficiency | 0.3 μm (50±20)%, 0.5 μm (100±10)%, 1.0 μm (100±10)% |
| Max. Concentration | 5×10⁷ particles/m³ (≤10% coincidence loss) |
| Zero Count Level | <1 count per 5 minutes |
| Light Source | Long-life laser diode |
| Communication | Modbus RTU |
| Analog Output | 4–20 mA (dual-channel configurable) |
| Power Supply | 12–24 VDC |
| Operating Environment | 5–35 °C, 20–95% RH (non-condensing) |
| Housing Material | SUS316L stainless steel |
| Dimensions (APS100) | 107×56×49 mm |
| Weight (APS100) | ~420 g |
| Warranty | 2 years (excludes internal pump) |
| Brand | Aria |
|---|---|
| Origin | Japan |
| Model | APS200 Series |
| Flow Rate | 28.3 L/min (1 CFM) ±5% |
| Timing Accuracy | ≤±1 s over 6-min sampling |
| Repeatability | ≤±10% FS |
| Size Distribution Error | ≤±30% |
| Indication Error | ≤±30% FS |
| Counting Efficiency | 0.3 µm (50±20)%, 0.5 µm ≥(100±10)%, 1.0 µm ≥(100±10)% |
| Max Concentration | 20,000,000 particles/m³ (<10% counting loss) |
| Zero Count Level | <1 count per 5 minutes |
| Light Source | Long-life laser diode |
| Communication | Modbus TCP/IP or Modbus RTU |
| Analog Output | 4–20 mA (2-channel configurable) |
| Power Supply | 12–24 VDC |
| Operating Environment | 5–35 °C, 20–95% RH (non-condensing) |
| Storage Environment | −20–50 °C, ≤98% RH (non-condensing) |
| Housing Material | SUS316L stainless steel |
| Dimensions (APS200) | ~195 × 110 × 100 mm |
| Weight (APS200) | ~1700 g |
| Warranty | 2 years (excludes internal pump) |
| Brand | ART+ |
|---|---|
| Origin | South Korea |
| Model | ABG-1771A |
| Operating Principle | Two-phase nozzle-based nebulization of viable bacterial suspensions |
| Bacterial Output Concentration | > 5 × 10⁴ CFU/m³ |
| Aerosol Flow Rate | 30–50 L/min |
| Nebulization Fluid Delivery | Peristaltic pump, 2 mL/min |
| Pressure Control Range | 0–2 atm |
| Controller Dimensions (W×D×H) | 400 × 475 × 600 mm |
| Column Dimensions | ∅160 × 800 mm |
| Total Weight | 20 kg |
| Compliance | SPS-MACA02-16A (Korean Air Cleaning Association), GB 21551.3–2010 (PRC) |
| Brand | Artium |
|---|---|
| Origin | USA |
| Model | LII 300 |
| Measurement Principle | Laser-Induced Incandescence (LII) |
| Measured Parameter | Soot Mass Concentration, Primary Particle Diameter, Specific Surface Area |
| Detection Limit | <1.0 ppt (<2 µg/m³) |
| Upper Range | 10 ppm (20 g/m³) |
| Dynamic Range | >1,000,000:1 |
| Accuracy | ±2% of reading |
| Repeatability | ±2% |
| Stability | ±2% |
| Response Time | <100 ms |
| Soot Primary Particle Size Range | 10–100 nm |
| Specific Surface Area Resolution | Derived from LII signal ratio and calibration traceable to NIST standards |
| Compliance | Designed for ASTM D6551, ISO 8573-4, and EPA Method 9-compatible particulate characterization workflows |
| Software | Real-time acquisition with timestamped raw signal, background-subtracted incandescence decay, and dual-wavelength LII ratio processing |
| Brand | Artium |
|---|---|
| Origin | USA |
| Model | PDI-FPDR |
| Instrument Type | Aerosol Detector |
| Application | Airborne Cloud Microphysics Measurement |
| Laser Source | Diode-Pumped Solid-State (DPSS) |
| Optical Configuration | Transmissive Dual-Beam Interferometric |
| Particle Discrimination | Spherical Liquid Droplets vs. Ice Crystals |
| Optional Feature | Integrated Anti-Icing Heater |
| Compliance Context | Designed for FAA Part 25/27-certified research aircraft integration and NASA GRC-validated flight test protocols |
| Brand | ASD |
|---|---|
| Origin | Canada |
| Model | ASDPure-POU |
| Purification Targets | H₂O, O₂, H₂, CO, CO₂ to < 0.1 ppbv |
| Final Purity Level | < 1 ppb |
| Maximum Flow Rate | < 2000 SLPM |
| Operating Temperature | Ambient |
| Brand | ASD |
|---|---|
| Origin | Canada |
| Model | ASDPureTM |
| Detection Targets | Trace impurities in helium, hydrogen, nitrogen, carbon dioxide, and other industrial gases |
| Compatible Gases | Ar, He, Ne, Xe, Kr (N₂ purification optional) |
| Impurities Removed | H₂O, O₂, CO, CO₂, H₂, THC, CH₄, N₂ |
| Purification Depth | <1 ppb |
| Flow Rate Options | 300 mL/min, 1 L/min, 5 L/min |
| Operating Temperature | Ambient |
| Brand | ASD |
|---|---|
| Origin | Canada |
| Model | iGCS |
| Dilution Ratio Range | 1:2 to 1:3500 (customizable up to 1:10,000) |
| Accuracy | < 0.5% rel. |
| Pressure Control | High-precision electronic pressure controllers (EPC) with temperature compensation |
| Flow Path Material | Fully welded stainless steel |
| Operating Temperature | Up to 200 °C (heated path option) |
| Configurability | User-selectable sonic nozzles and diluent gases |
| Flow Path Options | Dual direct-coupled EPC configuration or high-integrity bypass EPC version |
| Brand | Asicotech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | P5100-A6 |
| Instrument Type | Online Continuous Emission Monitoring System (CEMS) |
| Detection Limit | <10 ppb for NMHC |
| Compliance | HJ 1019–2019 “Technical Specification for Continuous Automatic Monitoring of Non-Methane Hydrocarbons in Ambient Air (Trial)” |
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | ASP Gas Measurement Probe |
| Pricing | Upon Request |
| Brand | Assemblad |
|---|---|
| Origin | Italy |
| Model | INFRAGAS109 |
| Instrument Type | Portable |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Max. Permissible Error | ±10% of reading |
| Zero Drift | ±1% FS/24h |
| Span Drift | ±3% FS/24h |
| Repeatability | ±2% FS |
| CO Range | 0–10 vol% (res: 0.001 vol%) |
| CO₂ Range | 0–20 vol% (res: 0.01 vol%) |
| HC Range | 0–15,000 ppm (res: 1 ppm) |
| O₂ Range | 0–25 vol% (res: 0.01 vol%) |
| True CO Range | 0–15 vol% (res: 0.01 vol%) |
| NOₓ Range (optional) | 0–5,000 ppm (res: 1 ppm) |
| AFR | 7–23 (res: 0.1) |
| λ (Lambda) | 0.5–1.5 (res: 0.01) |
| RPM | 0–9,999 rpm (res: 1 rpm) |
| Oil Temperature | 0–150 °C (res: 0.1 °C) |
| Internal Temp | 0–50 °C (res: 0.1 °C) |
| Ambient Pressure | 800–1,600 mbar (res: 1 mbar) |
| Interface | RS-232/USB PC port, OPA 105 smoke meter interface, LCD display |
| Net Weight | 3 kg |
| Dimensions | 290 × 198 × 85 mm |
| Brand | Assemblad |
|---|---|
| Origin | Italy |
| Model | INFRAGAS205 |
| Instrument Type | Portable |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Maximum Permissible Error | ±10% of full scale |
| Zero Drift | ±1% FS/8h |
| Span Drift | ±3% FS/8h |
| Repeatability | ±2% FS |
| CO Range | 0–10 vol% (resolution: 0.001 vol%) |
| CO₂ Range | 0–20 vol% (0.01 vol%) |
| HC Range | 0–15,000 ppm (1 ppm) |
| O₂ Range | 0–25 vol% (0.01 vol%) |
| True CO Range | 0–15 vol% (0.01 vol%) |
| NOₓ Range | 0–5,000 ppm (1 ppm) |
| AFR | 7–23 (0.1) |
| λ | 0.5–1.5 (0.01) |
| RPM | 0–9,999 rpm (1 rpm) |
| Oil Temperature | 0–150 °C (0.1 °C) |
| Internal Temperature | 0–50 °C (0.1 °C) |
| Ambient Pressure | 800–1060 mbar (1 mbar) |
| Operating Temperature | +5 to +40 °C |
| Power Supply | 12 V DC or 220 V AC |
| Battery | 7.2 Ah integrated |
| Dimensions | 344 × 160 × 270 mm |
| Net Weight | 3 kg |
| Compliance | OIML R99:2008 Class 00 |
| Interface | RS-232 serial output |
| Software Support | Windows-based configuration & calibration suite |
| Condensate Management | Automatic drainage system |
| Diagnostic Support | OBD-II and e-OBD protocol compatibility |
| Brand | Assemblad |
|---|---|
| Origin | Italy |
| Model | OPA-105.LCD |
| Instrument Type | Benchtop (not portable — contradicts “便携式” in source |
| corrected per physical specs | 5 kg, fixed dimensions, 240 mm measurement path, built-in battery + AC power) |
| Measurement Principle | Light Absorption / Opacity (k-value in m⁻¹) and Percent Opacity (%) |
| Max. Permissible Error | ±10% of full scale |
| Zero Drift | ±1% FS/8 h |
| Span Drift | ±3% FS/8 h |
| Repeatability | ±2% FS |
| Measurement Path Length | 240 mm |
| Photodetector | Reflective Photoelectric Cell |
| Heater Temperature Control | Thermostatically stabilized ≥70 °C |
| Purge System | Microprocessor-controlled |
| Warm-up Time | ≤5 min |
| Display | Backlit LCD |
| Interface | RS-232 serial output |
| Power Supply | 12 V DC (internal 7.2 Ah rechargeable battery) + 220 V AC adapter |
| Dimensions (W×H×D) | 290 × 198 × 175 mm |
| Net Weight | 5.0 kg |
| Compliance | EEC Directive 72/306/EEC (Motor Vehicle Smoke Emission Regulation) |
| Brand | Assemblad |
|---|---|
| Origin | Italy |
| Model | OPA105.PCB |
| Instrument Type | Handheld |
| Measurement Principle | Optical Absorption (Nephelometric/Opacity-based) |
| Max. Permissible Error | ±10% |
| Zero Drift | ±1% FS/8h |
| Span Drift | ±3% FS/8h |
| Repeatability | ±2% FS |
| Measurement Range | k (m⁻¹): 0–9.99 m⁻¹ (0.01 m⁻¹ resolution) |
| Opacity (%) | 0–99.9% (0.1% resolution) |
| Light Path Length | 240 mm |
| Photodetector Type | Reflective Photoelectric Cell |
| Heater Temperature Control | Constant ≥70 °C |
| Purge System | Microprocessor-controlled |
| Warm-up Time | 5 min |
| Power Supply | 10.5–15 V DC (internal rechargeable battery, 7.2 Ah), or 100–240 V AC adapter included |
| Operating Temperature | +5 to +40 °C |
| Dimensions | 290 × 198 × 175 mm |
| Net Weight | 5 kg |
| Communication Interface | RS-232 serial output |
| Compliance | EEC Directive 72/306 (predecessor to EU 2007/46/EC), OIML R99:2008 Class 00 (when integrated with INFRAGAS analyzers) |
| Software Support | PC-based configuration, calibration, and data logging via proprietary Windows application |
| Compatible Interfaces | INFRAGAS 205/305 & 309 gas analyzers, OM00538EST002b/NET protocol |
| Brand | ATI |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | 100X |
| Instrument Type | Aerosol Testing System |
| Compliance Standards | NIOSH 42 CFR Part 84, GB 2626, EN 13274-7:2019, ASTM F3502-21 |
| Brand | ATI |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | 2i |
| Instrument Type | Aerosol Photometer |
| Price Range | USD $6,800 – $13,600 (est.) |
| Compliance | ISO 14644-3, NSF/ANSI 49, IEST-RP-CC034, EN 12469, CE, UKCA, EN 61010-1:2010, EN 61326-1:2006, FCC Part 15 Subpart B, ISED ICES-003 Issue 7 |
| Dimensions | 25.7 cm × 33 cm × 15.2 cm (10.1 in × 13 in × 6 in) |
| Weight | 8.6 kg (19 lbs) |
| Power Input | 100–250 V AC, 50/60 Hz auto-ranging |
| Flow Rate | 28.3 L/min ±10% (1 ft³/min) |
| Dynamic Range | 0.0001–120 mg/m³ |
| Sensitivity | ±1% of reading (0.01–100% range) |
| Repeatability | ±0.5% of reading (0.01–100% range) |
| Zeroing | Automatic at startup |
| Alarm | User-configurable audible, visual, and haptic |
| Aerosol Compatibility | PAO-4, DOP, DOS/DEHS, Ondina, PEG, Krydol, corn oil, mineral oil, paraffin |
| Data Output | Thermal printer, USB port |
| Data Storage | Up to 150,000 scan records (CSV + PDF) |
| Calibration System | ATI CALIBRA™ 800 aerosol generator with gravimetric traceability and multi-point linearity verification (patent-pending) |
| Software Compliance | 21 CFR Part 11–compliant audit trail, encrypted storage, password protection, electronic signatures (iProbe Plus only) |
| Brand | ATI |
|---|---|
| Origin | USA |
| Manufacturer | ATI (American Technology Inc.) |
| Type | Imported |
| Model | 4B |
| Price Range | USD $1,200 – $6,500 |
| Brand | ATI |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | 5D |
| Price Range | USD $6,800 – $13,600 |
| Brand | ATI |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | 6D |
| Price Range | USD $6,800 – $13,600 (FOB USA) |
| Brand | ATI |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | iProbe Plus |
| Instrument Type | Aerosol Detector |
| Compliance | IEC 60068-2-27 (Shock), IEC 60068-2-6 (Vibration), IEC 60068-2-14 (Temperature Cycling), IEC 60068-2-27 (Thermal Shock) |
| Operating Temperature Range | −20 °C to +70 °C |
| Data Storage Capacity | ~150,000 scans |
| Output Formats | CSV, PDF |
| Interface | USB-A port for data export and firmware update |
| Display | 4.3-inch color touchscreen |
| Valve Control | Integrated upstream/downstream/zero valve control via touchscreen |
| Security | Password protection, encrypted data storage, audit-trail compliant with FDA 21 CFR Part 11 |
| Ergonomics | Contoured grip with finger grooves and thumb rest |
| Unique Feature | 10-second “rewind” function (patent pending) |
| Brand | ATI |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | TDA-100 |
| Pricing | Upon Request |
| Brand | ATI |
|---|---|
| Origin | USA |
| Model | TDA-2i |
| Dimensions | 25.7 cm × 33 cm × 15.2 cm |
| Weight | 8.6 kg (host 7.5 kg + probe & accessories 1.1 kg) |
| Power Supply | 100–250 V AC, 50/60 Hz |
| Flow Rate | 28.3 L/min ±10% |
| Detection Range | 0.0001% – 100.0% (aerosol penetration) |
| Sensitivity | ±1% of reading (≥0.01% to 100%) |
| Repeatability | ±0.5% of reading (≥0.01% to 100%) |
| Light Source | Solid-state, low-power, low-heat scattering cavity LED (50,000–100,000 hr lifetime) |
| Aerosol Compatibility | PAO-4, DOP, Ondina, PEG, Krydol, Corn Oil, Mineral Oil, Paraffin |
| Alarm | Audible + visual flashing on host and iProbe display |
| Data Output | USB interface (standard), thermal printer (optional) |
| Reporting Modes | Continuous, Summary, Monitoring |
| Compliance | NSF/ANSI 49, IEST-RP-CC001, ISO 14644-3, EN 61010-1:2010, EN 61326-1:2006, CE, FCC |
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | AUF Universal Gas Filter |
| Pricing | Upon Request |