| Brand | HunterLab |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | BPI Spectrophotometer |
| Price Range | USD $1,200 – $25,000 |
| Application System | Universal |
| Grating Configuration | Single-grating monochromator platform |
| Wavelength Range | 350 nm – 710 nm |
| Spectral Resolution | <10 nm (FWHM) |
| Dimensions | 6.75″ L × 6.25″ W × 5″ H |
| Weight | 8.5 lb |
| Power Supply | 110 V AC, 50/60 Hz, 1 A |
| Operating System Requirement | Microsoft Windows |
| Interface | USB 2.0 |
| Data Output | CIELAB (L*, a*, b*), Visible Transmittance (Tv), UVA Transmittance (315–400 nm) |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | LSZJQ |
| Pricing | Upon Request |
| Compatible Systems | Universal Microscope–Spectrometer–Camera Integration |
| Brand | McPherson |
|---|---|
| Origin | USA |
| Model | 248/310G |
| Wavelength Range | <1 nm to 310 nm |
| Spectral Resolution | 0.018 nm |
| Focal Length | 1000 mm |
| Optical Design | Grazing Incidence |
| Scanning Capability | Yes |
| Multichannel Detection Support | Yes |
| Compliance | Designed for UHV and synchrotron beamline integration |
| Detector Interface | Standard NIM & TTL-compatible output |
| Brand | McPherson |
|---|---|
| Origin | USA |
| Model | VUV Grating Spectrometer Series |
| Wavelength Range | 30 nm – 1200 nm (model-dependent) |
| Spectral Resolution | down to <0.0025 nm |
| Focal Length | 200 mm – 5000 mm |
| Optical Configuration | Czerny-Turner, Seya-Namioka, Normal Incidence (Autofocus & Off-Plane Eagle), Corrected Concave Holographic |
| Grating Mount | Motorized Multi-Grating Tower |
| Detector Compatibility | PMT, MCP, CCD, and Back-Illuminated Deep-UV/Soft-X-ray Arrays |
| Stray Light Suppression | <10⁻⁶ (typical, model- and grating-dependent) |
| Wavelength Accuracy | ±0.005 nm (with He-Ne reference laser calibration) |
| Dispersion | 1.2–8.5 nm/mm (depending on grating groove density and focal length) |
| Scan Functionality | Fully automated wavelength scanning with closed-loop encoder feedback |
| Multichannel Detection | Supported via fiber-coupled or direct-mount array detectors |
| Compliance | Designed for UHV-compatible operation (<1×10⁻⁷ Torr) |
| Brand | HORIBA |
|---|---|
| Origin | USA |
| Model | MicOS |
| Application | Fluorescence Spectroscopy |
| Grating Configuration | Triple-grating imaging spectrometer with motorized grating turret |
| Spectral Range | 200 nm – 1600 nm |
| Imaging Capability | Integrated digital camera for real-time sample visualization |
| Microscope Orientation | Inverted or side-entry configuration (compatible with cryostats) |
| Excitation Laser Compatibility | 325 nm, 405 nm, 488 nm, 532 nm, 633 nm, 785 nm |
| Objective Options | 10×, 50×, 100× (UV-VIS-NIR optimized) |
| Spot Size | down to <10 µm (dependent on objective and wavelength) |
| Detector Options | Back-illuminated CCD (200–1050 nm), InGaAs array (800–1600 nm), UV-enhanced CCD (190–1100 nm), selectable per spectral segment |
| Software Platform | LabSpec 6 (FDA 21 CFR Part 11 compliant audit trail, GLP/GMP-ready) |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | Omni-FD Series |
| Price | USD 56,000 (FOB Beijing) |
| Grating Configuration | Triple-Grating Turret |
| Incidence Angle | 87° |
| Vacuum Compatibility | ≤1×10⁻⁵ Pa |
| Grating Size | 50 mm × 30 mm |
| Detector Interface | MCP or Vacuum-Compatible CCD/CMOS Camera Mount |
| Spectral Ranges | 1–5 nm (2400 g/mm), 5–20 nm (1200 g/mm), 20–80 nm (300 g/mm) |
| Resolution (FWHM) | 0.02 nm @ 1–5 nm, 0.03 nm @ 5–20 nm, 0.15 nm @ 20–80 nm |
| Energy Range | 12.4–1240 eV |
| Stray Light Suppression | Optimized Entrance Optics with Baffling & Zero-Order Rejection Architecture |
| Focal Plane Adjustment | Continuous Translation Mechanism (±5 mm range) |
| Calibration | In-situ Wavelength Reference via He/Ne/Ar Plasma Lines or Synchrotron White Beam |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Model | Omni-iSpecT |
| Application Modes | Transmission & Reflection Spectroscopy |
| Grating Mount | Motorized Grating Turret |
| Spectral Resolution | As per Manual |
| Dispersion | As per Manual |
| Wavelength Range | 532–680 nm (Visible) / 0–4100 cm⁻¹ (Raman Shift) |
| F/# | f/1.8 |
| Wavelength Accuracy | ±0.2 nm (typ. at 532 nm), ±1 cm⁻¹ (typ. in Raman shift domain) |
| Stray Light | <0.01% (typ., 532 nm excitation) |
| Brand | Optometrics |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Mini-Chrom |
| Price | USD $2,000 |
| Application Systems | Transmission & Reflection Spectroscopy |
| Grating Mount | Rotatable Grating Table |
| Spectral Resolution | 0.3 nm (at 50 µm slit width, 2400 g/mm holographic grating) |
| Linear Dispersion | 5.34 nm/mm (2400 g/mm holographic grating) |
| Wavelength Range | 190–2200 nm |
| F/# | F/3.9 |
| Wavelength Accuracy | ±0.2% |
| Stray Light | ≤0.003% (measured at 632.8 nm HeNe laser line, 10 nm bandwidth) |
| Brand | Redback Systems |
|---|---|
| Origin | Australia |
| Model | RS10k |
| Spectral Range | 450–1030 nm |
| Resolution (R = λ/Δλ) | 17,000–10,000 |
| Wavelength Stability | <10 pm/°C |
| Wavelength Accuracy | <50 pm |
| SNR | 350:1 |
| Detector | Uncooled Sony STARVIS CMOS |
| Pixel Read Noise | <2 e⁻/pixel (rms) |
| Dark Current | <0.5 e⁻/pixel/s |
| Exposure Time | 1 ms–60 s |
| Data Acquisition Rate | Up to 10 Hz |
| Input Interface | Single-mode fiber, FC/PC |
| Dimensions (H×W×L) | 40 mm × 78 mm × 120 mm |
| Polarization Independence | Yes |
| Software | RedSolve (license-free) |
| API | Python-based RedMote SDK |
| Brand | Redback Systems |
|---|---|
| Origin | Australia |
| Model | RS40k |
| Spectral Range | 430–950 nm |
| Resolution (R = λ/Δλ) | 44,000–32,000 |
| Wavelength Stability | <5 pm/°C |
| Wavelength Accuracy | <20 pm |
| Input Interface | Single-mode fiber, FC/PC |
| Detector | Cooled sCMOS (Sony STARVIS) |
| Exposure Time | 1–20,000 ms |
| Dark Current | 0.2 e⁻/pixel/s |
| Read Noise | 1.9 e⁻/pixel (rms) |
| Data Acquisition Rate | up to 5 Hz |
| Dimensions (H×W×L) | 105 × 320 × 292 mm |
| Brand | Sciencetech |
|---|---|
| Origin | Canada |
| Model | 9030 Series |
| Spectral Range | 250–700 nm |
| Stray Light | 1.00E−03 |
| Grating Configuration | Dual Grating (Subtractive Mode) |
| Focal Length | 100 mm (Input & Output) |
| Optical Layout | Seya-Namioka |
| Grating Type | Concave Holographic |
| f-number | f/3.2 |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ±0.25 nm |
| Slit Options | Removable fixed-width slits (100 µm to 3 mm) |
| Detector Interface | Single-channel PMT-compatible output |
| Software Control | USB 2.0 (motorized version only) |
| Compliance | Designed for GLP/GMP-aligned spectroscopic workflows requiring traceable wavelength calibration and audit-ready operation |
| Brand | PV Measurements |
|---|---|
| Model | IV16 |
| Light Source Class | ABA-Class Solar Simulator (Standard) |
| Illuminated Area | 16 cm × 16 cm |
| Voltage Range | ±2.0 V |
| Current Range | 0–10 A |
| Spectral Match Compliance | ASTM E927-23, IEC 60904-9 Ed. 3 |
| Temporal Stability | < ±1% (A-class), < ±3% (B-class), < ±10% (C-class) |
| Irradiance Uniformity | < ±2% (A-class), < ±3% (B-class), < ±10% (C-class) |
| Standard Test Conditions (STC) | 1000 W/m², AM1.5G spectrum, 25 °C ± 2 °C |
| Software | IV Analysis Suite with GLP-compliant data logging, report generation (PDF/text), and audit-trail-enabled parameter calculation (Voc, Isc, Jsc, Pmax, Vmax, Imax, FF, η) |
| Sample Interface | 4-wire Kelvin connection |
| Optional Upgrades | AAA-class simulator, temperature-controlled vacuum chuck, Rs extraction via attenuated-light sweep, automated database export, reverse-bias leakage testing, conveyor integration |
| Brand | SPECREATION |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | Custom Configurable |
| Price | Upon Request |
| Spectral Resolution | 0.07 nm @ 50 µm Slit Width |
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | IRIS |
| Pricing | USD 27,500 (FOB) |
| Application System | Universal |
| Grating Configuration | Dual Echelle Gratings |
| Spectral Resolution | 0.1–0.45 nm (with 25 µm × 100 µm slit) |
| Dispersion | Echelle + Cross-Disperser Architecture |
| Wavelength Range | 180–800 nm |
| F-number | f/2 |
| Wavelength Accuracy | ±0.1–0.45 nm |
| Stray Light Rejection | < 1×10⁻⁵ (typical, per ISO 14644-1 cleanroom-aligned optical alignment) |
| Brand | Topo |
|---|---|
| Model | DS-100 |
| Wavelength Range | 200–800 nm |
| Focal Length | 300 mm or 500 mm |
| Relative Aperture | D/F = 1/7 |
| Wavelength Accuracy | ±0.4 nm |
| Wavelength Repeatability | ±0.2 nm |
| Scanning Method | Manual Drive with Digital Wavelength Display |
| Origin | Tianjin, China |
| Manufacturer Type | OEM Manufacturer |
| Brand | Topo (TP) |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Model | DS-100 Compact |
| Application Systems | Transmission & Reflection Spectroscopy |
| Grating Mount | Rotatable Grating Stage |
| Spectral Resolution | ≤0.12 nm |
| Groove Density | 1200 grooves/mm |
| Wavelength Range | 200–800 nm |
| F-number | F/5 |
| Wavelength Accuracy | ±1 nm |
| Stray Light | ≤0.3% T |
| Slit Widths | Fixed at 0.15 mm and 0.3 mm |
| Wavelength Repeatability | ±0.5 nm |
| Dimensions | 120 × 90 × 65 mm |
| Weight | 0.8 kg |
| Brand | Topo |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TP-DSA1 |
| Pricing | Upon Request |
| Application System | Universal |
| Brand | Topo (TP) |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Model | WDS-3 |
| Price | Upon Request |
| Focal Length | 300 mm |
| Wavelength Range | 200–800 nm |
| Relative Aperture | D/F = 1/7 |
| Grating Density | 600 or 1200 lines/mm |
| Stray Light | ≤0.3% T |
| Wavelength Accuracy | ±0.4 nm |
| Slit Width Adjustment | 0–2 mm (continuous), 0.01 mm/division, max 20 mm |
| Spectral Bandwidth (FWHM) | ≤0.2 nm at 589 nm (slit height 3 mm, width 0.2 mm) |
| Detector | Photomultiplier Tube (PMT) |
| Interface | USB |
| Brand | Topo |
|---|---|
| Model | WDS-4 |
| Focal Length | 300 mm |
| Relative Aperture | D/F = 1/7 |
| Stray Light Level | ≤0.3% T |
| Spectral Resolution | Resolves seven polystyrene transmission peaks at 3000 nm |
| Detector Options | TGS pyroelectric detector, PbS photoconductive detector, HgCdTe (MCT) photovoltaic detector |
| Interface | USB |
| Dimensions | 370 × 280 × 200 mm |
| Origin | Tianjin, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Brand | Topo (TP) |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | OEM Manufacturer |
| Model | WDS-5 |
| Focal Length | 500 mm |
| Wavelength Range | 200–800 nm |
| Relative Aperture | D/F = 1/7 |
| Grating Density | 1200 lines/mm (optional) |
| Wavelength Accuracy | ±0.4 nm |
| Wavelength Repeatability | ±0.2 nm |
| Spectral Resolution | <0.1 nm |
| Stray Light | ≤0.1% T |
| Slit Width Adjustment | 0–2 mm (continuous, vernier scale with 0.01 mm/division) |
| Slit Height | up to 20 mm |
| Interface | USB 2.0 |
| Dimensions (L×W×H) | 530 × 330 × 220 mm |
| Brand | Topo/TP |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | WDS-8A |
| Application Systems | Transmission & Reflectance Spectroscopy |
| Grating Mount | Dual-grating turret (exchangeable gratings) |
| Spectral Resolution | ≤0.06 nm (measured at Na I 330.23/330.29 nm doublet) |
| Groove Density | 2400 grooves/mm |
| Wavelength Range | 200–660 nm (PMT detection) |
| F-number | F/7 |
| Wavelength Accuracy | ±0.2 nm (200–660 nm) |
| Wavelength Repeatability | ≤0.1 nm |
| Stray Light | ≤0.1% T |
| Slit Width Adjustment | 0–2 mm, continuously variable |
| Focal Length | 500 mm |
| Relative Aperture | D/F = 1/7 |
| Interface | USB 2.0 |
| Dimensions (L×W×H) | 530 × 330 × 220 mm |
| Weight | 28 kg |
| Brand | Topo (TP) |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | WSD-1A |
| Application System | General-purpose |
| Grating Mount | Yes |
| Dispersion Element | Diffraction Grating |
| Wavelength Range | 380–780 nm |
| Wavelength Accuracy | ±0.4 nm |
| Wavelength Repeatability | ≤0.2 nm |
| Grating Density | 1200 lines/mm |
| Focal Length | f = 300 mm |
| Relative Aperture | D/F = 1/7 |
| Transmittance Accuracy | ±1% T |
| Noise Level | ±0.5% T |
| Slit Width Adjustment | 0–2.5 mm (continuously variable, resolution 0.01 mm per division) |
| Standard Observer | CIE 10° Standard Observer |
| Chromaticity Coordinate Resolution | x, y ±0.001 |
| Chromaticity Measurement Accuracy | Δx ±0.02, Δy ±0.03 |
| Light Source | 12 V / 20 W Tungsten-Halogen Lamp |
| Brand | SPECREATION |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Model | CP-SR |
| Spectral Resolution | 0.1 nm @ 37.93 nm (tunable via grating selection) |
| Wavelength Range | 10–300 nm |
| Brand | ZEISS |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model Range | Full-Series Gratings |
| Application System | Universal |
| Grating Configuration | Dual-Grating Mounting |
| Spectral Resolution | 0.5 nm (at 10 µm slit width) |
| Dispersion | 16 nm/mm |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.1 nm |
| F-number | F/4 |
| Stray Light | ≤0.1% T |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | HiperS-320i |
| Application System | Universal |
| Grating Mount | Triple-grating in-axis rotating turret |
| Spectral Resolution | 0–1430 nm range (with resolution down to 0.06 nm @ 1200 g/mm grating, PMT detection) |
| Linear Dispersion | 2.29 nm/mm (@ 435.83 nm) |
| Wavelength Accuracy | ±0.2 nm |
| Stray Light Level | 5×10⁻⁵ |
| Brand | ZOLIX |
|---|---|
| Model | Imspector Series |
| Type | Grating-Based Imaging Spectrometer |
| Wavelength Ranges | UV (200–400 nm), VIS (380–780 nm), VNIR (400–1000 nm), NIR (900–1700 nm), SWIR (1000–2500 nm), MWIR (3000–5000 nm), LWIR (8000–12000 nm) |
| Detector Interface | Compatible with 2/3″ and larger area array detectors |
| Frame Rate (Fast Version) | Up to 1500 spectra/s |
| Optical Design | Transmissive grating-based, Czerny-Turner or Offner relay architecture (model-dependent) |
| Compliance | Designed for laboratory and field-deployable spectroscopic imaging applications in accordance with ISO 17025-aligned calibration practices |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Omni-V200 |
| Price | USD 42,000 (FOB Beijing) |
| Spectral Resolution | 0.1 nm |
| Wavelength Range | 80–300 nm |
| Optical Design | Aberration-Corrected Imaging S-N System |
| Incidence Angle | 32° |
| Focal Length | 200 mm |
| Wavelength Accuracy | ±0.1 nm (@1200 g/mm grating) |
| Wavelength Repeatability | ±0.1 nm (@1200 g/mm grating) |
| Operating Vacuum | ≤1×10⁻⁶ Torr |
| Grating Groove Density | 1200 lines/mm |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | Omni-λ |
| Pricing | Upon Request |
| Focal Length Options | 150 mm, 300 mm, 500 mm, 750 mm |
| Optical Design | Czerny–Turner (C-T) |
| Grating Mount | Dual-grating turret (Omni-λ150/300), Triple-grating turret (Omni-λ500/750) |
| Grating Size | 68 × 68 mm (standard for ≥300 mm models) |
| Wavelength Range | UV-VIS-NIR (190–2500 nm, dependent on grating and detector selection) |
| Resolution (with 1200 g/mm grating) | 0.4 nm (Omni-λ150) to 0.03 nm (Omni-λ750) |
| Wavelength Accuracy | ±0.25 nm (Omni-λ150) to ±0.2 nm (Omni-λ300+) |
| Wavelength Repeatability | ±0.1 nm |
| Minimum Scan Step | 0.005 nm |
| Entrance/Exit Configuration | Motorized dual-input/dual-output port selection |
| Interface | USB 2.0 (standard), RS-232 (optional) |
| Slit Options | Manual (0.01–3 mm width, 2/4/10/14 mm height) or motorized automatic slit |
| Optional Accessories | Motorized filter wheel, electronic shutter, CCD array or single-point detector integration |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Omni-λ Series |
| Application Systems | Transmission & Reflection Spectroscopy |
| Number of Gratings | Dual-grating turret |
| Spectral Resolution | 0.4 nm (FWHM, @1200 g/mm grating, 10 µm slit) |
| Linear Dispersion | 3.68 nm/mm |
| Wavelength Range | 400–1000 nm (standard configuration) |
| F-number | f/4.2 |
| Wavelength Accuracy | ±0.25 nm |
| Stray Light Level | ≤0.1% (typical), down to 1×10⁻⁵ with optimized gratings and baffling |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model Series | Omni-λ Imaging Monochromator Series |
| Pricing | Available Upon Request |
| Focal Length Options | 180 mm, 320 mm, 500 mm, 750 mm |
| Optical Design | Czerny-Turner with Aspheric Image Correction |
| Grating Mount | Dual- or Triple-Grating Turret |
| Grating Sizes | 40×40 mm, 68×68 mm (or 68×84 mm) |
| Wavelength Range | UV–VIS–NIR (190–2500 nm), Optimized for IR (>1 µm) with Gold-Coated Optics |
| Stray Light Suppression | ≤1×10⁻⁵ |
| Control Interface | USB 2.0 (standard), RS-232 (optional) |
| Drive System | DSP-Based Motorized Control |
| Slit Options | Manual (0.01–3 mm width, 2/4/10/14 mm height) or Motorized Adjustable Slit |
| Detector Compatibility | PMT, CCD (26 µm pixel pitch), InGaAs, MCT |
| Entrance/Exit Port Configuration | Single or Dual Input/Output (software-selectable) |
| Typical Resolution (1200 g/mm grating) | 0.028–0.35 nm (CCD/PMT dependent) |
| Wavelength Accuracy | ±0.1–±0.2 nm |
| Wavelength Repeatability | ±0.01–±0.1 nm |
| Scan Step Size | 0.0025–0.01 nm |
| Focal Plane Dimensions | 30 mm (w) × 10–14 mm (h) |
| Optical Axis Height | 146.5 mm |
| Relative Aperture | f/4 to f/9.7 |