| Brand | ASIDA |
|---|---|
| Model | XK22 |
| Origin | Guangdong, China |
| Type | Optical Metrology System for Printed Circuit Board Inspection |
| Measurement Principle | High-Resolution Digital Microscopy with Sub-Pixel Edge Detection |
| Max. Board Width | ≤760 mm |
| Field of View | 0.53×0.4 mm to 3.4×2.5 mm |
| Minimum Measurable Line Width | ≥20 µm |
| Measurement Accuracy | ±1 µm |
| Pixel Resolution | 0.70–5.20 µm/pixel |
| Total Magnification Range | 70×–450× |
| Optical Zoom | 1.4×–9× Continuous |
| SPC Capability | Yes |
| Illumination | Red LED Targeting Light |
| Weight (system only) | 145 kg |
| Dimensions (W×D×H, excl. PC) | 960×700×1280 mm |
| Compliance | Designed for IPC-6012, IPC-A-600, and ISO 9001-aligned QA/QC workflows |
| Software | Proprietary ASIDA Vision Suite with Audit Trail & Export to CSV/XLSX |
| Brand | Asida |
|---|---|
| Model | XG5130A |
| Origin | Guangdong, China |
| Type | Online, Fully Automated X-ray Inspection System |
| Application | In-line Quality Control of Prismatic Pouch Lithium-ion Battery Cells |
| X-ray Source | Microfocus Tube (90 kV, 89 µA, 5 µm focal spot) |
| Imaging System | Dual-FOV Image Intensifier (2″/4″), 75–110 lp/cm resolution, X-CCD sensor (752 × 480 px) |
| Throughput | ≥30 ppm (≥30,000 units/day) |
| Measurement Repeatability | ±60 µm |
| False Positive Rate | ≤2% |
| Miss Detection Rate | 0.0% |
| Overall Yield Accuracy | ≥99.5% |
| Radiation Leakage | ≤1 µSv/hr (compliant with IEC 61000-6-4 and IEC 62471) |
| Brand | Asida |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | QQ1000 |
| Pricing | Available Upon Request |
| Brand | ASIDA |
|---|---|
| Model | QQ1000 |
| Origin | Guangdong, China |
| Detection Principle | Non-contact CCD-based laser triangulation |
| Max. PCB Size | 630 × 550 mm |
| Min. PCB Size | 40 × 80 mm |
| Thickness Range | 0.3–5.0 mm |
| Warpage Measurement Range | 0.3–3.0 mm |
| Accuracy | ±0.1 mm |
| Conveyor Speed Options | 6.5 m/min or 12.5 m/min |
| Minimum Board Spacing | ≥40 mm |
| Operating Temperature | 22 °C ± 5 °C |
| Power Supply | AC 220 V, 50 Hz |
| Air Pressure Requirement | 0.5–0.7 MPa |
| Dimensions (L×W×H) | 3510 × 1160 × 1050 mm |
| Weight | 450 kg |
| Brand | ASIDA |
|---|---|
| Model | LJ101A |
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | PRC |
| Print Resolution | 720 × 720 dpi / 720 × 1440 dpi |
| PCB Size Range | 170 × 220 mm to 660 × 610 mm |
| PCB Thickness Capacity | 0.1–6 mm |
| Minimum Line Width | 70 µm |
| Minimum Character Height | 0.5 mm |
| Printhead | KM1024 (14 pL drop volume) |
| Print Speed | ≤70 s per side (for 24″ × 18″ panel) |
| Registration Method & Accuracy | CCD-based three-point auto-alignment |
| Curing System | UV LED lamp with active cooling |
| Power Supply | AC 380 V, 10 A, 50 Hz |
| Air Supply | Dry compressed air, 0.5–0.8 MPa |
| Dimensions (W×D×H) | 1350 × 1790 × 1500 mm |
| Weight | 1500 kg |
| Brand | ASIDA |
|---|---|
| Origin | Guangdong, China |
| Model | ASIDA6050A, ASIDA7060A, ASIDA8070A |
| Measurement Range (X×Y×Z) | 600×500×200 mm |
| Optical Magnification | 0.75×–5× Objective + Digital Zoom → Total Magnification: 30×–230× |
| Encoders Resolution | ≤0.001 mm |
| X/Y Linear Accuracy | (3 + L/200) µm (L in mm) |
| Repeatability | ≤±0.003 mm |
| Worktable Size | 650×550 mm / 750×650 mm / 850×750 mm |
| Max Load Capacity | 30 kg |
| Working Distance | 82 mm |
| Software | AISDA MEASURE VMA 3.00.01 (Trilingual: Simplified Chinese, Traditional Chinese, English) |
| Output Formats | DXF, Excel (.xlsx), Word (.docx) |
| OS Compatibility | Windows XP Pro, Windows 7 |
| Minimum PC Requirements | Dual-Core CPU, ≥2 GB RAM, ≥320 GB HDD |
| Power Supply | 220 V AC, 50 Hz |
| Environmental Conditions | Temp. 20 ±2 °C, Humidity 45–75 % RH, Vibration <0.002 g (<15 Hz) |
| Optional Accessories | NAVITAR Metrology Lens (USA), RENISHAW TP20 Trigger Probe (UK), KEYENCE LJ-V Series Laser Displacement Sensor (Japan) |
| Brand | Asida |
|---|---|
| Model | LJ101A |
| Application | Permanent inkjet marking of legends, serial numbers, barcodes, and identifiers on rigid and flexible printed circuit boards (PCBs) |
| Print Resolution | 720 × 720 dpi / 720 × 1440 dpi |
| Max. PCB Size | 660 × 610 mm |
| Min. PCB Size | 170 × 220 mm |
| PCB Thickness Range | 0.1–6 mm |
| Minimum Line Width | 70 µm |
| Minimum Character Height | 0.5 mm |
| Printhead | KM1024 (14 pL drop volume) |
| Positioning Accuracy | ≤35 µm (CCD-based three-point auto-alignment) |
| UV Curing System | Integrated air-cooled UV lamp with instant curing |
| Cycle Time | ≤70 s per side (for 24″ × 18″ panel) |
| Power Supply | AC 380 V, 10 A, 50 Hz |
| Pneumatic Supply | Dry compressed air, 0.5–0.8 MPa |
| Dimensions (W×D×H) | 1350 × 1790 × 1500 mm |
| Weight | 1500 kg |
| Brand | ASIDA |
|---|---|
| Model | ASIDA-XNDI-BAT |
| Origin | Guangdong, China |
| Type | Benchtop X-ray Transmission Imaging System for In-line Cell QA/QC |
| Detection Principle | X-ray Radiography (2.5D Digital Radiography) |
| Motion Architecture | Motorized XYZ Manipulation of X-ray Source and Image Intensifier |
| Software | Proprietary Automated Defect Recognition (ADR) Suite with CNC Path Memory & Real-time Image Processing |
| Compliance | Designed to Support ISO 9001 Quality Audits, ASTM E2737-21 (Standard Practice for Digital Radiographic Testing), and GLP/GMP-aligned QA workflows |
| Brand | ASIDA |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | XK23 |
| Pricing | Available Upon Request |
| Measurement Accuracy | ±1 µm |
| Pixel Resolution (XK23) | 0.4–2.6 µm/pixel |
| Total Magnification | 70–450× |
| Optical Zoom | 1.4–9× Continuous |
| Maximum Board Width | ≤760 mm |
| Field of View | 0.53×0.4 mm to 3.4×2.5 mm |
| Minimum Measurable Line Width | ≥20 µm |
| Instrument Dimensions (excl. PC) | 960×780×1280 mm |
| Weight | 190 kg |
| [Brand | Asida |
|---|---|
| Origin | Guangdong, China |
| Model | LV12 |
| Test Method | Static Extraction |
| Measurement Accuracy | ±5% |
| Conductivity Resolution | 0.001 µS/cm |
| Sample Plate Size Range | 10 cm × 10 cm to 60 cm × 35 cm |
| Extractant Density | 0.85–0.855 g/cm³ |
| Extractant Volume | ~17 L |
| Water Tank Dimensions | 352 mm × 70 mm × 600 mm (L×W×H) |
| Overall Dimensions | 1050 mm × 600 mm × 920 mm (L×W×H) |
| Power Consumption | 1300 W |
| Input Voltage/Frequency | 220 V / 50 Hz |
| Net Weight | ~115 kg |
| Operating Ambient Temperature | 22 ± 3 °C |
| Extractant Temperature Control | 40 ± 2 °C |
| Compliance | GB/T 4677.22a, GB/T 18268, SJ/T 11364, IPC-6012B Clause 3.9, IPC-TM-650 2.3.25B] |
| Brand | Astroda |
|---|---|
| Model | XG5600 |
| Origin | Guangdong, China |
| Detector Type | Flat-Panel Digital Radiography System |
| Max. Tube Voltage | 110 kV |
| Max. Tube Current | 450 µA |
| Focal Spot Size | 5 µm |
| Cooling Method | Forced Air |
| Detector Active Area | 54 mm × 48 mm |
| Spatial Resolution | 20.8 lp/mm |
| Pixel Matrix | 2000 × 2249 / 1000 × 1124 |
| Repeatability Accuracy | ±60 µm |
| Throughput | ≥50 ppm |
| False Positive Rate | ≤2% |
| False Negative Rate | 0.0% |
| Pass Rate Consistency | ≥99.5% |
| Radiation Leakage | ≤1 µSv/hr (measured at 5 cm from enclosure surface) |
| Compliance | IEC 61000-6-3, IEC 61000-6-4, GBZ 126-2011, ANSI N43.3 |
| Brand | Astroda |
|---|---|
| Origin | Guangdong, China |
| Model | XG5 |
| Price Range | USD 70,000 – 140,000 |
| Category | X-ray Radiographic Inspection System for Electronics Assembly |
| Detection Principle | Transmission X-ray Imaging (2.5D) |
| Motion Control | CNC-programmable XYZ-axis movement of X-ray source and image intensifier |
| Image Acquisition | Real-time digital radiography with software-based measurement and pass/fail classification |
| Compliance | Designed to support IPC-A-610, IPC-J-STD-001, and ISO 9001 quality audit workflows |
| Software | Proprietary automated inspection suite with measurement tools (linear distance, circle diameter, concentricity, point-to-center), navigation mapping, and DICOM-compatible image export |
| Brand | Astroda |
|---|---|
| Model | XG5100 |
| Application | In-line/Off-line Automated Radiographic Inspection of Polymer Pouch-Type Li-ion Cells and Sealed Battery Packs |
| X-ray Tube Voltage | Up to 110 kV |
| X-ray Tube Current | Up to 450 µA |
| Focal Spot Size | 5 µm |
| Detector Type | Line-Scan CCD/CMOS Array |
| Sensitive Area | 235 mm × 13 mm |
| Repeatability Accuracy | ±60 µm |
| Throughput | ≥25 parts per minute (ppm) |
| False Positive Rate | ≤2% |
| Miss Detection Rate | 0.0% |
| Overall Yield Compliance Rate | ≥99.5% |
| Radiation Leakage | ≤1 µSv/hr at any accessible surface |
| Cooling Method | Forced-Air Cooled X-ray Source |
| Safety Certification | Compliant with IEC 61000-6-4, IEC 61000-6-2, and GBZ 126–2011 (China National Standard for Radiation Protection in Industrial X-ray Equipment) |
| Brand | ASIDA |
|---|---|
| Model | 8070 |
| Measurement Range (X×Y×Z) | 800 mm × 700 mm × 200 mm |
| Granite Base & Column | Grade-0 Natural Granite |
| Motion System | Air-bearing Guideways (X/Y), Panasonic Servo Motors |
| Optical Magnification | 0.75×–5× Objective + 1× Eyepiece → Total 30×–230× |
| Encoders | ≤0.001 mm Resolution |
| Linear Accuracy | ≤(3 + L/200) µm (L in mm) |
| Repeatability | ≤±0.003 mm |
| Illumination | Ring-type LED Cold Light Source |
| Software | AISDA VMA 3.00.01 (Trilingual: Simplified Chinese, Traditional Chinese, English) |
| Output Formats | DXF, Excel, Word |
| Compliance | Designed for ISO 10360-2 & GB/T 16857.2 compliant geometric metrology workflows |
| Environmental Requirements | 20 ±2 °C, 45–75% RH, Vibration <0.002 g (<15 Hz) |
| Optional Accessories | NAVITAR Metrology Lens, Renishaw TP20 Trigger Probe Kit, KEYENCE LJ-V Series Laser Displacement Sensor |
| Brand | ASIDA |
|---|---|
| Model | LJ101A |
| Origin | Guangdong, China |
| Type | PCB/FPC Character Marking System |
| Print Resolution | 720×720 dpi / 720×1440 dpi |
| Max. PCB Size | 660×610 mm |
| Min. PCB Size | 170×220 mm |
| PCB Thickness Range | 0.1–6 mm |
| Minimum Line Width | 70 µm |
| Minimum Character Height | 0.5 mm |
| Printhead | KM1024 (14 pL) |
| Positioning Accuracy | ≤35 µm (CCD-based 3-point registration) |
| Print Speed | ≤70 s per side (for 24″×18″ panel) |
| Curing | UV LED system with active cooling |
| Power Supply | AC 380 V, 10 A, 50 Hz |
| Air Supply | Dry compressed air, 0.5–0.8 MPa |
| Dimensions (W×D×H) | 1350×1790×1500 mm |
| Weight | 1500 kg |
| Brand | Asida |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JX22 |
| Pricing | Available Upon Request |
| Optical Magnification | 50×–600× |
| Digital Magnification | 90×–1080× |
| Eyepiece | Wide-Field 10× |
| Objective Lenses | Plan Achromatic 5×, 10×, 40×, 60× |
| Illumination | Reflected 6V/20W Halogen Lamp with Adjustable Brightness and Polarizer |
| Camera | DLCW 1.3 MP CCD |
| Measurement Accuracy | ±0.0006 mm |
| Brand | Astroda |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | XG5130 |
| Pricing | Available Upon Request |
| X-ray Tube Voltage | 90 kV |
| X-ray Tube Current | 200 µA |
| Focal Spot Size | 5 µm |
| Cooling Method | Forced Air Cooling |
| Detection Accuracy | 40 µm |
| Radiation Leakage | ≤1 µSv/hr (compliant with IEC 61000-4-3 & IEC 62471) |
| Brand | ASIDA |
|---|---|
| Model | CQ2000 |
| Origin | Guangdong, China |
| Instrument Type | Metallographic Slitting & Precision Cutting System for Prepreg Rolls |
| Cutting Accuracy | ±1 mm |
| Cut Edge Quality | No whitening, delamination, wrinkling, charring, or stringing |
| Dust Reduction | >95% vs. conventional mechanical cutting |
| Cutting Frequency (500 mm length) | ≤18 cuts/min |
| Cut Length Range | 250–750 mm |
| Cut Width Range | 200–1270 mm |
| Material Thickness Range | 0.04–0.3 mm |
| Dimensions (L×W×H) | 2657 × 2200 × 1658 mm |
| Weight | 1800 kg |
| Brand | ASIDA |
|---|---|
| Model | LZ21 |
| Type | Sodium Ion–Specific Dynamic Conductivity-Based Ionic Contamination Tester for Printed Circuit Boards |
| Measurement Principle | Dynamic Extraction + Conductivity Monitoring per IPC-TM-650 2.3.25.1 & J-STD-001 |
| Operating Temperature | 40 °C ± 0.3 °C |
| Extractant Volume Options | 17 L (standard), 30 L (enlarged) |
| PCB Test Area Range | 1200–8712 cm² |
| Conductivity Resolution | 0.0001 µS/cm² |
| Accuracy | ±5% |
| Power | 1700 W |
| Dimensions (enlarged) | 1401 × 600 × 1000 mm |
| Weight (enlarged) | ~150 kg |
| Compliance | IPC-TM-650, J-STD-001, ISO 9001-aligned test environment control |
| Brand | Astroda |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CB11 |
| Quotation | Upon Request |
| Throat Depth | 530 mm |
| Thickness Measurement Range | 0–25 mm |
| Stroke | 25 mm |
| Tabletop Dimensions | 900 × 870 mm |
| Accuracy | ±0.003 mm |
| Display | LCD (mm/inch switchable) |
| Zeroing Function | Arbitrary Position |
| Tabletop Material | Phenolic Resin (Electrical Insulating Board) |
| Power Supply | 220 V AC, 50 Hz / 100 W |
| Net Weight | 120 kg |
| Brand | Astroda |
|---|---|
| Model | XG5120 |
| Origin | Guangdong, China |
| X-ray Tube Voltage | 90 kV |
| X-ray Tube Current | 200 µA |
| Focal Spot Size | 5 µm |
| Cooling Method | Forced Air Cooling |
| Detection Accuracy | 40 µm |
| Radiation Leakage | ≤1 µSv/hr (per IEC 61331-1 & FDA 21 CFR §1020.40) |
| Throughput | ≥30,000 units/day |
| Reconfiguration Time | 0.5–2 h |
| Compliance | CE, ISO 13485 (for medical device manufacturing support), GB/T 18871-2002, IEC 62495 |
| Brand | ASIDA |
|---|---|
| Model | Manual Vision Measuring Machine (2010/3020/4030/5040 Series) |
| Measurement Principle | Optical Coordinate Metrology with CCD Imaging |
| Base Material | Natural Granite |
| Motion System | Precision Linear Rolling Guides + Friction-Driven Stage |
| Illumination | Adjustable Ring LED Cold Light Source |
| Optics | Manual Zoom Objective (0.7×–4.5× or 0.7×–5.0×) + Interchangeable Eyepieces (0.5×, 1×, 2×) |
| Encoder Resolution | 1 µm |
| XY Axis Accuracy | (3 + L/200) µm (L in mm) |
| Repeatability | ≤ ±3 µm |
| Z-Axis Travel | 150–200 mm |
| XY Travel Range | 200×100 mm to 500×400 mm |
| Stage Load Capacity | 25 kg |
| Working Distance | 90 mm |
| Software | ASIDA VMM3.0D (Multilingual: English, Simplified Chinese, Traditional Chinese) |
| Compliance | Designed for ISO 10360-7 and GB/T 16857.7 alignment with geometric dimensioning and tolerancing (GD&T) workflows |
| Brand | Astroda |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | PP CQ2000 |
| Pricing | Available Upon Request |
| Brand | ASIDA |
|---|---|
| Model | LZ12 |
| Type | Static Ionic Contamination Tester for Printed Circuit Boards |
| Measurement Principle | Conductivity-based extraction analysis per IPC-TM-650 2.3.25 and J-STD-001 |
| Standard Extractant Volume | 17 L (customizable up to 30 L) |
| Extractant Temperature Control | 40 ± 2 °C |
| Test Area Range | 1200–8712 cm² |
| Conductivity Resolution | 0.0001 µS/cm² |
| Accuracy | ±5% |
| Electrode Sensitivity Range | 0.0001–9999.9999 µS/cm² |
| Power Supply | AC 220 V, 50 Hz |
| Rated Power | 1300 W |
| Dimensions (Std) | 1050 × 600 × 920 mm |
| Weight (Std) | ~115 kg |
| Operating Ambient | 22 ± 3 °C |
| Data Output | Excel (.xlsx), USB/RS232 interface |
| Language Support | English & Simplified Chinese |
| Security | Multi-level password protection |
| Thermal Stability | ±0.3 °C at 40 °C setpoint |
| Resin Filtration System | Mixed-bed anion/cation exchange resin |
| Compliance | IPC, JEDEC, ISO 9001-aligned workflow support |
| Software | Embedded PC-controlled acquisition with real-time conductivity curve plotting and auto-report generation |