BrandASIDA
ModelXK22
OriginGuangdong, China
TypeOptical Metrology System for Printed Circuit Board Inspection
Measurement PrincipleHigh-Resolution Digital Microscopy with Sub-Pixel Edge Detection
Max. Board Width≤760 mm
Field of View0.53×0.4 mm to 3.4×2.5 mm
Minimum Measurable Line Width≥20 µm
Measurement Accuracy±1 µm
Pixel Resolution0.70–5.20 µm/pixel
Total Magnification Range70×–450×
Optical Zoom1.4×–9× Continuous
SPC CapabilityYes
IlluminationRed LED Targeting Light
Weight (system only)145 kg
Dimensions (W×D×H, excl. PC)960×700×1280 mm
ComplianceDesigned for IPC-6012, IPC-A-600, and ISO 9001-aligned QA/QC workflows
SoftwareProprietary ASIDA Vision Suite with Audit Trail & Export to CSV/XLSX
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAsida
ModelXG5130A
OriginGuangdong, China
TypeOnline, Fully Automated X-ray Inspection System
ApplicationIn-line Quality Control of Prismatic Pouch Lithium-ion Battery Cells
X-ray SourceMicrofocus Tube (90 kV, 89 µA, 5 µm focal spot)
Imaging SystemDual-FOV Image Intensifier (2″/4″), 75–110 lp/cm resolution, X-CCD sensor (752 × 480 px)
Throughput≥30 ppm (≥30,000 units/day)
Measurement Repeatability±60 µm
False Positive Rate≤2%
Miss Detection Rate0.0%
Overall Yield Accuracy≥99.5%
Radiation Leakage≤1 µSv/hr (compliant with IEC 61000-6-4 and IEC 62471)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAsida
OriginGuangdong, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelQQ1000
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandASIDA
ModelQQ1000
OriginGuangdong, China
Detection PrincipleNon-contact CCD-based laser triangulation
Max. PCB Size630 × 550 mm
Min. PCB Size40 × 80 mm
Thickness Range0.3–5.0 mm
Warpage Measurement Range0.3–3.0 mm
Accuracy±0.1 mm
Conveyor Speed Options6.5 m/min or 12.5 m/min
Minimum Board Spacing≥40 mm
Operating Temperature22 °C ± 5 °C
Power SupplyAC 220 V, 50 Hz
Air Pressure Requirement0.5–0.7 MPa
Dimensions (L×W×H)3510 × 1160 × 1050 mm
Weight450 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandASIDA
ModelLJ101A
OriginGuangdong, China
Manufacturer TypeAuthorized Distributor
Country of OriginPRC
Print Resolution720 × 720 dpi / 720 × 1440 dpi
PCB Size Range170 × 220 mm to 660 × 610 mm
PCB Thickness Capacity0.1–6 mm
Minimum Line Width70 µm
Minimum Character Height0.5 mm
PrintheadKM1024 (14 pL drop volume)
Print Speed≤70 s per side (for 24″ × 18″ panel)
Registration Method & AccuracyCCD-based three-point auto-alignment
Curing SystemUV LED lamp with active cooling
Power SupplyAC 380 V, 10 A, 50 Hz
Air SupplyDry compressed air, 0.5–0.8 MPa
Dimensions (W×D×H)1350 × 1790 × 1500 mm
Weight1500 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandASIDA
OriginGuangdong, China
ModelASIDA6050A, ASIDA7060A, ASIDA8070A
Measurement Range (X×Y×Z)600×500×200 mm
Optical Magnification0.75×–5× Objective + Digital Zoom → Total Magnification: 30×–230×
Encoders Resolution≤0.001 mm
X/Y Linear Accuracy(3 + L/200) µm (L in mm)
Repeatability≤±0.003 mm
Worktable Size650×550 mm / 750×650 mm / 850×750 mm
Max Load Capacity30 kg
Working Distance82 mm
SoftwareAISDA MEASURE VMA 3.00.01 (Trilingual: Simplified Chinese, Traditional Chinese, English)
Output FormatsDXF, Excel (.xlsx), Word (.docx)
OS CompatibilityWindows XP Pro, Windows 7
Minimum PC RequirementsDual-Core CPU, ≥2 GB RAM, ≥320 GB HDD
Power Supply220 V AC, 50 Hz
Environmental ConditionsTemp. 20 ±2 °C, Humidity 45–75 % RH, Vibration <0.002 g (<15 Hz)
Optional AccessoriesNAVITAR Metrology Lens (USA), RENISHAW TP20 Trigger Probe (UK), KEYENCE LJ-V Series Laser Displacement Sensor (Japan)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAsida
ModelLJ101A
ApplicationPermanent inkjet marking of legends, serial numbers, barcodes, and identifiers on rigid and flexible printed circuit boards (PCBs)
Print Resolution720 × 720 dpi / 720 × 1440 dpi
Max. PCB Size660 × 610 mm
Min. PCB Size170 × 220 mm
PCB Thickness Range0.1–6 mm
Minimum Line Width70 µm
Minimum Character Height0.5 mm
PrintheadKM1024 (14 pL drop volume)
Positioning Accuracy≤35 µm (CCD-based three-point auto-alignment)
UV Curing SystemIntegrated air-cooled UV lamp with instant curing
Cycle Time≤70 s per side (for 24″ × 18″ panel)
Power SupplyAC 380 V, 10 A, 50 Hz
Pneumatic SupplyDry compressed air, 0.5–0.8 MPa
Dimensions (W×D×H)1350 × 1790 × 1500 mm
Weight1500 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandASIDA
ModelASIDA-XNDI-BAT
OriginGuangdong, China
TypeBenchtop X-ray Transmission Imaging System for In-line Cell QA/QC
Detection PrincipleX-ray Radiography (2.5D Digital Radiography)
Motion ArchitectureMotorized XYZ Manipulation of X-ray Source and Image Intensifier
SoftwareProprietary Automated Defect Recognition (ADR) Suite with CNC Path Memory & Real-time Image Processing
ComplianceDesigned to Support ISO 9001 Quality Audits, ASTM E2737-21 (Standard Practice for Digital Radiographic Testing), and GLP/GMP-aligned QA workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandASIDA
OriginGuangdong, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelXK23
PricingAvailable Upon Request
Measurement Accuracy±1 µm
Pixel Resolution (XK23)0.4–2.6 µm/pixel
Total Magnification70–450×
Optical Zoom1.4–9× Continuous
Maximum Board Width≤760 mm
Field of View0.53×0.4 mm to 3.4×2.5 mm
Minimum Measurable Line Width≥20 µm
Instrument Dimensions (excl. PC)960×780×1280 mm
Weight190 kg
Added to wishlistRemoved from wishlist 0
Add to compare
[BrandAsida
OriginGuangdong, China
ModelLV12
Test MethodStatic Extraction
Measurement Accuracy±5%
Conductivity Resolution0.001 µS/cm
Sample Plate Size Range10 cm × 10 cm to 60 cm × 35 cm
Extractant Density0.85–0.855 g/cm³
Extractant Volume~17 L
Water Tank Dimensions352 mm × 70 mm × 600 mm (L×W×H)
Overall Dimensions1050 mm × 600 mm × 920 mm (L×W×H)
Power Consumption1300 W
Input Voltage/Frequency220 V / 50 Hz
Net Weight~115 kg
Operating Ambient Temperature22 ± 3 °C
Extractant Temperature Control40 ± 2 °C
ComplianceGB/T 4677.22a, GB/T 18268, SJ/T 11364, IPC-6012B Clause 3.9, IPC-TM-650 2.3.25B]
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAstroda
ModelXG5600
OriginGuangdong, China
Detector TypeFlat-Panel Digital Radiography System
Max. Tube Voltage110 kV
Max. Tube Current450 µA
Focal Spot Size5 µm
Cooling MethodForced Air
Detector Active Area54 mm × 48 mm
Spatial Resolution20.8 lp/mm
Pixel Matrix2000 × 2249 / 1000 × 1124
Repeatability Accuracy±60 µm
Throughput≥50 ppm
False Positive Rate≤2%
False Negative Rate0.0%
Pass Rate Consistency≥99.5%
Radiation Leakage≤1 µSv/hr (measured at 5 cm from enclosure surface)
ComplianceIEC 61000-6-3, IEC 61000-6-4, GBZ 126-2011, ANSI N43.3
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAstroda
OriginGuangdong, China
ModelXG5
Price RangeUSD 70,000 – 140,000
CategoryX-ray Radiographic Inspection System for Electronics Assembly
Detection PrincipleTransmission X-ray Imaging (2.5D)
Motion ControlCNC-programmable XYZ-axis movement of X-ray source and image intensifier
Image AcquisitionReal-time digital radiography with software-based measurement and pass/fail classification
ComplianceDesigned to support IPC-A-610, IPC-J-STD-001, and ISO 9001 quality audit workflows
SoftwareProprietary automated inspection suite with measurement tools (linear distance, circle diameter, concentricity, point-to-center), navigation mapping, and DICOM-compatible image export
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAstroda
ModelXG5100
ApplicationIn-line/Off-line Automated Radiographic Inspection of Polymer Pouch-Type Li-ion Cells and Sealed Battery Packs
X-ray Tube VoltageUp to 110 kV
X-ray Tube CurrentUp to 450 µA
Focal Spot Size5 µm
Detector TypeLine-Scan CCD/CMOS Array
Sensitive Area235 mm × 13 mm
Repeatability Accuracy±60 µm
Throughput≥25 parts per minute (ppm)
False Positive Rate≤2%
Miss Detection Rate0.0%
Overall Yield Compliance Rate≥99.5%
Radiation Leakage≤1 µSv/hr at any accessible surface
Cooling MethodForced-Air Cooled X-ray Source
Safety CertificationCompliant with IEC 61000-6-4, IEC 61000-6-2, and GBZ 126–2011 (China National Standard for Radiation Protection in Industrial X-ray Equipment)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandASIDA
Model8070
Measurement Range (X×Y×Z)800 mm × 700 mm × 200 mm
Granite Base & ColumnGrade-0 Natural Granite
Motion SystemAir-bearing Guideways (X/Y), Panasonic Servo Motors
Optical Magnification0.75×–5× Objective + 1× Eyepiece → Total 30×–230×
Encoders≤0.001 mm Resolution
Linear Accuracy≤(3 + L/200) µm (L in mm)
Repeatability≤±0.003 mm
IlluminationRing-type LED Cold Light Source
SoftwareAISDA VMA 3.00.01 (Trilingual: Simplified Chinese, Traditional Chinese, English)
Output FormatsDXF, Excel, Word
ComplianceDesigned for ISO 10360-2 & GB/T 16857.2 compliant geometric metrology workflows
Environmental Requirements20 ±2 °C, 45–75% RH, Vibration <0.002 g (<15 Hz)
Optional AccessoriesNAVITAR Metrology Lens, Renishaw TP20 Trigger Probe Kit, KEYENCE LJ-V Series Laser Displacement Sensor
Added to wishlistRemoved from wishlist 0
Add to compare
BrandASIDA
ModelLJ101A
OriginGuangdong, China
TypePCB/FPC Character Marking System
Print Resolution720×720 dpi / 720×1440 dpi
Max. PCB Size660×610 mm
Min. PCB Size170×220 mm
PCB Thickness Range0.1–6 mm
Minimum Line Width70 µm
Minimum Character Height0.5 mm
PrintheadKM1024 (14 pL)
Positioning Accuracy≤35 µm (CCD-based 3-point registration)
Print Speed≤70 s per side (for 24″×18″ panel)
CuringUV LED system with active cooling
Power SupplyAC 380 V, 10 A, 50 Hz
Air SupplyDry compressed air, 0.5–0.8 MPa
Dimensions (W×D×H)1350×1790×1500 mm
Weight1500 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAsida
OriginGuangdong, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelJX22
PricingAvailable Upon Request
Optical Magnification50×–600×
Digital Magnification90×–1080×
EyepieceWide-Field 10×
Objective LensesPlan Achromatic 5×, 10×, 40×, 60×
IlluminationReflected 6V/20W Halogen Lamp with Adjustable Brightness and Polarizer
CameraDLCW 1.3 MP CCD
Measurement Accuracy±0.0006 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAstroda
OriginGuangdong, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelXG5130
PricingAvailable Upon Request
X-ray Tube Voltage90 kV
X-ray Tube Current200 µA
Focal Spot Size5 µm
Cooling MethodForced Air Cooling
Detection Accuracy40 µm
Radiation Leakage≤1 µSv/hr (compliant with IEC 61000-4-3 & IEC 62471)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandASIDA
ModelCQ2000
OriginGuangdong, China
Instrument TypeMetallographic Slitting & Precision Cutting System for Prepreg Rolls
Cutting Accuracy±1 mm
Cut Edge QualityNo whitening, delamination, wrinkling, charring, or stringing
Dust Reduction>95% vs. conventional mechanical cutting
Cutting Frequency (500 mm length)≤18 cuts/min
Cut Length Range250–750 mm
Cut Width Range200–1270 mm
Material Thickness Range0.04–0.3 mm
Dimensions (L×W×H)2657 × 2200 × 1658 mm
Weight1800 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandASIDA
ModelLZ21
TypeSodium Ion–Specific Dynamic Conductivity-Based Ionic Contamination Tester for Printed Circuit Boards
Measurement PrincipleDynamic Extraction + Conductivity Monitoring per IPC-TM-650 2.3.25.1 & J-STD-001
Operating Temperature40 °C ± 0.3 °C
Extractant Volume Options17 L (standard), 30 L (enlarged)
PCB Test Area Range1200–8712 cm²
Conductivity Resolution0.0001 µS/cm²
Accuracy±5%
Power1700 W
Dimensions (enlarged)1401 × 600 × 1000 mm
Weight (enlarged)~150 kg
ComplianceIPC-TM-650, J-STD-001, ISO 9001-aligned test environment control
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAstroda
OriginGuangdong, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelCB11
QuotationUpon Request
Throat Depth530 mm
Thickness Measurement Range0–25 mm
Stroke25 mm
Tabletop Dimensions900 × 870 mm
Accuracy±0.003 mm
DisplayLCD (mm/inch switchable)
Zeroing FunctionArbitrary Position
Tabletop MaterialPhenolic Resin (Electrical Insulating Board)
Power Supply220 V AC, 50 Hz / 100 W
Net Weight120 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAstroda
ModelXG5120
OriginGuangdong, China
X-ray Tube Voltage90 kV
X-ray Tube Current200 µA
Focal Spot Size5 µm
Cooling MethodForced Air Cooling
Detection Accuracy40 µm
Radiation Leakage≤1 µSv/hr (per IEC 61331-1 & FDA 21 CFR §1020.40)
Throughput≥30,000 units/day
Reconfiguration Time0.5–2 h
ComplianceCE, ISO 13485 (for medical device manufacturing support), GB/T 18871-2002, IEC 62495
Added to wishlistRemoved from wishlist 0
Add to compare
BrandASIDA
ModelManual Vision Measuring Machine (2010/3020/4030/5040 Series)
Measurement PrincipleOptical Coordinate Metrology with CCD Imaging
Base MaterialNatural Granite
Motion SystemPrecision Linear Rolling Guides + Friction-Driven Stage
IlluminationAdjustable Ring LED Cold Light Source
OpticsManual Zoom Objective (0.7×–4.5× or 0.7×–5.0×) + Interchangeable Eyepieces (0.5×, 1×, 2×)
Encoder Resolution1 µm
XY Axis Accuracy(3 + L/200) µm (L in mm)
Repeatability≤ ±3 µm
Z-Axis Travel150–200 mm
XY Travel Range200×100 mm to 500×400 mm
Stage Load Capacity25 kg
Working Distance90 mm
SoftwareASIDA VMM3.0D (Multilingual: English, Simplified Chinese, Traditional Chinese)
ComplianceDesigned for ISO 10360-7 and GB/T 16857.7 alignment with geometric dimensioning and tolerancing (GD&T) workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAstroda
OriginGuangdong, China
Manufacturer TypeAuthorized Distributor
Regional ClassificationDomestic (China)
ModelPP CQ2000
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandASIDA
ModelLZ12
TypeStatic Ionic Contamination Tester for Printed Circuit Boards
Measurement PrincipleConductivity-based extraction analysis per IPC-TM-650 2.3.25 and J-STD-001
Standard Extractant Volume17 L (customizable up to 30 L)
Extractant Temperature Control40 ± 2 °C
Test Area Range1200–8712 cm²
Conductivity Resolution0.0001 µS/cm²
Accuracy±5%
Electrode Sensitivity Range0.0001–9999.9999 µS/cm²
Power SupplyAC 220 V, 50 Hz
Rated Power1300 W
Dimensions (Std)1050 × 600 × 920 mm
Weight (Std)~115 kg
Operating Ambient22 ± 3 °C
Data OutputExcel (.xlsx), USB/RS232 interface
Language SupportEnglish & Simplified Chinese
SecurityMulti-level password protection
Thermal Stability±0.3 °C at 40 °C setpoint
Resin Filtration SystemMixed-bed anion/cation exchange resin
ComplianceIPC, JEDEC, ISO 9001-aligned workflow support
SoftwareEmbedded PC-controlled acquisition with real-time conductivity curve plotting and auto-report generation