BrandIonSense
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelDART JS
Instrument TypeAtmospheric Pressure Ion Source
Application ScopeUniversal
Mass Range15–6000 Da
SensitivityLow-ppt (liquid samples)
ResolutionDetermined by coupled mass spectrometer
Accurate Mass CapabilityDependent on host MS platform
Operating PressureAmbient (atmospheric pressure)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPhytronix
OriginCanada
ModelLuxon
Instrument TypeAtmospheric Pressure Ion Source
TechnologySecond-Generation Laser Diode Array Thermal Desorption (LDTD²)
Sample ThroughputUp to 30,000+ samples/24h
Analysis Time per Sample≤ 0.6 s
Compatible Plate Formats96-well, 384-well, 1536-well LazWell™ microplates
Automation LevelFully Robotic, Unattended Operation
MS CompatibilitySCIEX, Thermo Fisher, Waters, Shimadzu triple quadrupole and Q-TOF mass spectrometers
Regulatory AlignmentDesigned for GLP/GMP-compliant workflows with audit-trail-ready software architecture
Ionization MechanismSolvent-free, atmospheric-pressure chemical ionization (APCI) via laser-induced rapid thermal desorption
Added to wishlistRemoved from wishlist 0
Add to compare
[BrandDenator AB
OriginSweden
ModelStabilizor T1
TypeImport
Distribution StatusAuthorized Distributor]
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCovalX
OriginSwitzerland
ModelHM4 or Pearl
CompatibilityTOF and TOF/TOF Mass Spectrometers (Bruker, Shimadzu, SCIEX)
Detection PrincipleDual-Stage Dynode Conversion with High-Voltage Electron Multiplication
Mass Range>2.5 MDa
SensitivitySub-nM for Intact Protein Complexes
Vacuum ArchitectureIntegrated High-Vacuum Tube with Electroless Nickel Plating (Patent WO 2009086642)
Ion PolaritySimultaneous Positive/Negative Mode Detection
SoftwareCovalX “ComplexTracer” Data Analysis Suite
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMassTech (ASPEC as authorized distributor)
OriginUSA
Instrument Type3D Ion Trap Mass Spectrometer
ModelMT50
Mass Range30–2500 amu
Sensitivity50 pg/µL reserpine, S/N ≥ 10:1
Resolution6000 (FWHM at m/z 400)
Mass Accuracy±0.3 amu
Scan Speed1000–8000 amu/s or up to 5 spectra/sec
Ionization CompatibilityESI, oESI, 2ndESI, APCI, DART, AP/MALDI
Power Input90–240 VAC, 50/60 Hz
Power Consumption250–300 W
Dimensions (L×W×H)51 × 43 × 30 cm
Weight<35 kg
Operating ModeMS¹ and MSⁿ (up to MS⁵)
PolarityPositive/Negative Switchable
Gas RequirementNone (gas-free operation)
TransportShock-damped wheeled case
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPhytronix
OriginCanada
ModelLDTD, Luxon
Instrument TypeIon Source
Sample Introduction Speed≤6 s (LDTD), ≤1 s (Luxon), 0.6 s (Luxon-1536)
Ionization ModeAtmospheric Pressure Chemical Ionization (APCI) via Laser-Induced Thermal Desorption
CompatibilityTriple Quadrupole (QqQ), Ion Trap, TOF, Q-TOF, Orbitrap, and Hybrid MS Platforms (SCIEX, Thermo Fisher, Shimadzu, Waters)
Sample Format96-well, 384-well, 1536-well plates (barcoded LazWell™ plates)
Carrier GasZero-air (≤3 ppm H₂O) or dried air with VOC scrubber
Laser SourceInfrared laser diode array, 20 W max output, power ramp 0–45% in 3 s, hold at 45% for ~2 s, then rapid decay to 0%
Sample Volume0.5–10 µL (depending on plate format)
Residual CarryoverNone (no memory effect)
Regulatory ComplianceFully compatible with GLP/GMP workflows
Environmental ImpactSolvent-free, column-free, pump-free operation — eliminates LC consumables (mobile phases, columns, tubing, vials, filters)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMassTech
OriginUSA
ModelUHR, HR
Instrument TypeAtmospheric Pressure Ion Source
SensitivityAttomole-level (sub-fmol/µL)
Spatial Resolution<5 µm
Mass RangeDetermined by Coupled Mass Analyzer
Accurate Mass CapabilityDependent on Host Mass Spectrometer
Added to wishlistRemoved from wishlist 0
Add to compare
BrandASPEC
OriginUSA
ModelPST Nano-Column Heaters
Temperature RangeAmbient to 100°C (for heating variants) / –5°C to 60°C (PST-CHC-LT+), ±0.2°C stability
Heating ConfigurationsButterfly-style (PST-BPH-15, PST-BPH-20), Sleeve-type (PST-CH-xxU, PST-CH-30-50U), Partial-column (PST-BCH-15, PST-BCH-30), Extended-box (PST-CH-LT-20, PST-CH-LT), Cryogenic (PST-CC, PST-CHC-LT+)
Compatible Column FormatsPicoFrit®, eFrit®, integrated nanoLC columns (C4, C8, C18), trap columns, emitter tips, and associated capillary tubing and fittings
ControllerPST-CHC-RC universal temperature controller with PID regulation and digital display
Added to wishlistRemoved from wishlist 0
Add to compare
BrandASPEC
OriginUSA
ManufacturerIonSense, Inc.
ModelASAP
Instrument TypeAtmospheric Pressure Ionization Source
Mass Range5–3000 amu
Sensitivitypg-level (dependent on coupled mass spectrometer)
ResolutionDetermined by host MS platform
Accurate Mass CapabilityEnabled via compatible high-resolution MS (e.g., Orbitrap, FT-ICR, QTOF)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandASPEC (Prosolia)
OriginUSA
ModelFlowprobe
Instrument TypeAmbient Ion Source
Compatible MS PlatformsThermo Orbitrap, Bruker timsTOF, SCIEX TripleTOF & QTRAP
Sample InterfaceLiquid Microjet Surface Sampling Probe (LMJ-SSP)
Spatial Resolution~630 µm (rapid profiling), down to ~50 µm (high-res DESI-2D integration)
Operating ModeReal-time, continuous-flow in situ microextraction coupled with ESI ionization
Optical GuidanceIntegrated coaxial camera for real-time probe positioning and surface navigation
Application ScopeLabel-free molecular imaging of tissues, single-cell metabolomics, spatially resolved lipidomics/peptidomics, forensic toxicology, dried blood spot (DBS) analysis, time-resolved pharmacokinetics
Added to wishlistRemoved from wishlist 0
Add to compare
BrandASPEC (Huazhi Taike)
OriginGermany
ManufacturerPlasmion GmbH
ModelSICRIT® SC-20X
Dimensions250 × 180 × 80 mm
Weight2.4 kg
Power SupplyStandard 100–240 V AC, 50/60 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandASPEC
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelNimbus
Instrument TypeElectrospray Ionization (ESI) Source
CompatibilityThermo and SCIEX LC-MS Systems
Operating ModeStandalone (No External PC or Software Required)
Key TechnologyIntegrated eFrit Nanospray Emitters, Dual-Column Switching, On-Chip Column Heating & Temperature Control, Active Spray Tip Purging with Sheath Nitrogen Gas
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAdvion
OriginUSA
ModelTriVersa NanoMate®
Instrument TypeChip-Based Nanoelectrospray Ion Source
Mass Range100 Da – 100 kDa
SensitivityDependent on Coupled Mass Spectrometer
ResolutionDependent on Coupled Mass Spectrometer
Accurate Mass CapabilityDependent on Coupled Mass Spectrometer
ComplianceASTM E2915, ISO/IEC 17025 (when operated in GLP/GMP environments), FDA 21 CFR Part 11–ready software architecture