| Brand | IonSense |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DART JS |
| Instrument Type | Atmospheric Pressure Ion Source |
| Application Scope | Universal |
| Mass Range | 15–6000 Da |
| Sensitivity | Low-ppt (liquid samples) |
| Resolution | Determined by coupled mass spectrometer |
| Accurate Mass Capability | Dependent on host MS platform |
| Operating Pressure | Ambient (atmospheric pressure) |
| Brand | Phytronix |
|---|---|
| Origin | Canada |
| Model | Luxon |
| Instrument Type | Atmospheric Pressure Ion Source |
| Technology | Second-Generation Laser Diode Array Thermal Desorption (LDTD²) |
| Sample Throughput | Up to 30,000+ samples/24h |
| Analysis Time per Sample | ≤ 0.6 s |
| Compatible Plate Formats | 96-well, 384-well, 1536-well LazWell™ microplates |
| Automation Level | Fully Robotic, Unattended Operation |
| MS Compatibility | SCIEX, Thermo Fisher, Waters, Shimadzu triple quadrupole and Q-TOF mass spectrometers |
| Regulatory Alignment | Designed for GLP/GMP-compliant workflows with audit-trail-ready software architecture |
| Ionization Mechanism | Solvent-free, atmospheric-pressure chemical ionization (APCI) via laser-induced rapid thermal desorption |
| [Brand | Denator AB |
|---|---|
| Origin | Sweden |
| Model | Stabilizor T1 |
| Type | Import |
| Distribution Status | Authorized Distributor] |
| Brand | CovalX |
|---|---|
| Origin | Switzerland |
| Model | HM4 or Pearl |
| Compatibility | TOF and TOF/TOF Mass Spectrometers (Bruker, Shimadzu, SCIEX) |
| Detection Principle | Dual-Stage Dynode Conversion with High-Voltage Electron Multiplication |
| Mass Range | >2.5 MDa |
| Sensitivity | Sub-nM for Intact Protein Complexes |
| Vacuum Architecture | Integrated High-Vacuum Tube with Electroless Nickel Plating (Patent WO 2009086642) |
| Ion Polarity | Simultaneous Positive/Negative Mode Detection |
| Software | CovalX “ComplexTracer” Data Analysis Suite |
| Brand | MassTech (ASPEC as authorized distributor) |
|---|---|
| Origin | USA |
| Instrument Type | 3D Ion Trap Mass Spectrometer |
| Model | MT50 |
| Mass Range | 30–2500 amu |
| Sensitivity | 50 pg/µL reserpine, S/N ≥ 10:1 |
| Resolution | 6000 (FWHM at m/z 400) |
| Mass Accuracy | ±0.3 amu |
| Scan Speed | 1000–8000 amu/s or up to 5 spectra/sec |
| Ionization Compatibility | ESI, oESI, 2ndESI, APCI, DART, AP/MALDI |
| Power Input | 90–240 VAC, 50/60 Hz |
| Power Consumption | 250–300 W |
| Dimensions (L×W×H) | 51 × 43 × 30 cm |
| Weight | <35 kg |
| Operating Mode | MS¹ and MSⁿ (up to MS⁵) |
| Polarity | Positive/Negative Switchable |
| Gas Requirement | None (gas-free operation) |
| Transport | Shock-damped wheeled case |
| Brand | Phytronix |
|---|---|
| Origin | Canada |
| Model | LDTD, Luxon |
| Instrument Type | Ion Source |
| Sample Introduction Speed | ≤6 s (LDTD), ≤1 s (Luxon), 0.6 s (Luxon-1536) |
| Ionization Mode | Atmospheric Pressure Chemical Ionization (APCI) via Laser-Induced Thermal Desorption |
| Compatibility | Triple Quadrupole (QqQ), Ion Trap, TOF, Q-TOF, Orbitrap, and Hybrid MS Platforms (SCIEX, Thermo Fisher, Shimadzu, Waters) |
| Sample Format | 96-well, 384-well, 1536-well plates (barcoded LazWell™ plates) |
| Carrier Gas | Zero-air (≤3 ppm H₂O) or dried air with VOC scrubber |
| Laser Source | Infrared laser diode array, 20 W max output, power ramp 0–45% in 3 s, hold at 45% for ~2 s, then rapid decay to 0% |
| Sample Volume | 0.5–10 µL (depending on plate format) |
| Residual Carryover | None (no memory effect) |
| Regulatory Compliance | Fully compatible with GLP/GMP workflows |
| Environmental Impact | Solvent-free, column-free, pump-free operation — eliminates LC consumables (mobile phases, columns, tubing, vials, filters) |
| Brand | MassTech |
|---|---|
| Origin | USA |
| Model | UHR, HR |
| Instrument Type | Atmospheric Pressure Ion Source |
| Sensitivity | Attomole-level (sub-fmol/µL) |
| Spatial Resolution | <5 µm |
| Mass Range | Determined by Coupled Mass Analyzer |
| Accurate Mass Capability | Dependent on Host Mass Spectrometer |
| Brand | ASPEC |
|---|---|
| Origin | USA |
| Model | PST Nano-Column Heaters |
| Temperature Range | Ambient to 100°C (for heating variants) / –5°C to 60°C (PST-CHC-LT+), ±0.2°C stability |
| Heating Configurations | Butterfly-style (PST-BPH-15, PST-BPH-20), Sleeve-type (PST-CH-xxU, PST-CH-30-50U), Partial-column (PST-BCH-15, PST-BCH-30), Extended-box (PST-CH-LT-20, PST-CH-LT), Cryogenic (PST-CC, PST-CHC-LT+) |
| Compatible Column Formats | PicoFrit®, eFrit®, integrated nanoLC columns (C4, C8, C18), trap columns, emitter tips, and associated capillary tubing and fittings |
| Controller | PST-CHC-RC universal temperature controller with PID regulation and digital display |
| Brand | ASPEC |
|---|---|
| Origin | USA |
| Manufacturer | IonSense, Inc. |
| Model | ASAP |
| Instrument Type | Atmospheric Pressure Ionization Source |
| Mass Range | 5–3000 amu |
| Sensitivity | pg-level (dependent on coupled mass spectrometer) |
| Resolution | Determined by host MS platform |
| Accurate Mass Capability | Enabled via compatible high-resolution MS (e.g., Orbitrap, FT-ICR, QTOF) |
| Brand | ASPEC (Prosolia) |
|---|---|
| Origin | USA |
| Model | Flowprobe |
| Instrument Type | Ambient Ion Source |
| Compatible MS Platforms | Thermo Orbitrap, Bruker timsTOF, SCIEX TripleTOF & QTRAP |
| Sample Interface | Liquid Microjet Surface Sampling Probe (LMJ-SSP) |
| Spatial Resolution | ~630 µm (rapid profiling), down to ~50 µm (high-res DESI-2D integration) |
| Operating Mode | Real-time, continuous-flow in situ microextraction coupled with ESI ionization |
| Optical Guidance | Integrated coaxial camera for real-time probe positioning and surface navigation |
| Application Scope | Label-free molecular imaging of tissues, single-cell metabolomics, spatially resolved lipidomics/peptidomics, forensic toxicology, dried blood spot (DBS) analysis, time-resolved pharmacokinetics |
| Brand | ASPEC (Huazhi Taike) |
|---|---|
| Origin | Germany |
| Manufacturer | Plasmion GmbH |
| Model | SICRIT® SC-20X |
| Dimensions | 250 × 180 × 80 mm |
| Weight | 2.4 kg |
| Power Supply | Standard 100–240 V AC, 50/60 Hz |
| Brand | ASPEC |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Nimbus |
| Instrument Type | Electrospray Ionization (ESI) Source |
| Compatibility | Thermo and SCIEX LC-MS Systems |
| Operating Mode | Standalone (No External PC or Software Required) |
| Key Technology | Integrated eFrit Nanospray Emitters, Dual-Column Switching, On-Chip Column Heating & Temperature Control, Active Spray Tip Purging with Sheath Nitrogen Gas |
| Brand | Advion |
|---|---|
| Origin | USA |
| Model | TriVersa NanoMate® |
| Instrument Type | Chip-Based Nanoelectrospray Ion Source |
| Mass Range | 100 Da – 100 kDa |
| Sensitivity | Dependent on Coupled Mass Spectrometer |
| Resolution | Dependent on Coupled Mass Spectrometer |
| Accurate Mass Capability | Dependent on Coupled Mass Spectrometer |
| Compliance | ASTM E2915, ISO/IEC 17025 (when operated in GLP/GMP environments), FDA 21 CFR Part 11–ready software architecture |