- All
- Favorite
- Popular
- Most rated
| Brand | Sundy |
|---|---|
| Origin | Hunan, China |
| Model | SDACM3200 |
| Measurement Mode | Isoperibolic Calorimetry |
| Instrument Type | Oxygen Bomb Calorimeter |
| Temperature Resolution | 0.0001 °C |
| Thermal Capacity Stability | ≤0.25% over 3 months |
| Thermal Capacity Precision | ≤0.15% RSD |
| Single Test Duration | ≤15 min |
| External Jacket Temperature Drift | <0.1 °C per test |
| Max Power Consumption | 0.15 kW |
| Supply Voltage | AC 220 V ±10%, 50 Hz ±1 Hz |
| Dimensions (Main Unit) | 500 × 600 × 425 mm |
| Weight (Main Unit) | ~65 kg |
| Water Jacket Dimensions | 550 × 356 × 520 mm |
| Water Jacket Weight | ~17.5 kg |
| Compliance | GB/T 213–2008, GB/T 384–1981, GB/T 30727–2014, ASTM D5865–2007, ISO 1928–2009, JC/T 1005–2006 |
| Brand | Sundy |
|---|---|
| Origin | Hunan, China |
| Instrument Type | Oxygen Bomb Calorimeter |
| Measurement Principle | Isoperibol (Constant-Temperature Jacket) Calorimetry |
| Compliance Standards | GB/T 213-2008, GB/T 384-1981, GB/T 30727-2014, ASTM D5865-2007, ISO 1928-2020, JC/T 1005-2006 |
| Single Test Duration (Rapid Mode) | <11 min |
| Temperature Resolution | 0.0001 °C |
| Heat Capacity Precision | ≤0.10% RSD |
| Heat Capacity Drift | ≤0.20% per year |
| Ignition Methods | SDAC1600 – Ignition Rod |
| Power Supply | AC 220 V ±10%, 50 Hz ±1 Hz |
| Max Power Consumption | 0.65 kW |
| Host Dimensions (SDAC1600) | 439 × 565 × 485 mm |
| (SDAC1200/SDAC1600L) | 390 × 565 × 485 mm |
| Water Bath Dimensions | 220 × 565 × 410 mm |
| Host Weight | ~50 kg |
| Water Bath Weight | ~25 kg |
| Brand | Sundy |
|---|---|
| Origin | Hunan, China |
| Model | SDNS300t / SDNS200t |
| Sieve Diameter × Height | Φ200 mm × 50 mm |
| Max. Sieve Layers | 8 |
| Sieve Cut Range | 6 mm – 0.045 mm |
| Stack Height | 400 mm |
| Eccentric Radius | 12.5 mm |
| Max. Sample Mass | 200 g |
| Dimensions (W×D×H) | 655×470×980 mm (SDNS300t) / 620×470×935 mm (SDNS200t) |
| Weight | 130 kg (SDNS300t) / 100 kg (SDNS200t) |
| Power | 0.37 kW |
| Supply Voltage | AC 380 V ±10%, 50 Hz ±1 Hz |
| Compliance | GB/T 474–2008 |
| Brand | Sundy |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | SDAC1000 |
| Pricing | Upon Request |
| Intelligence Level | Fully Automated |
| Instrument Type | Isoperibol Oxygen Bomb Calorimeter |
| Temperature Measurement Range | 0–40 °C |
| Temperature Resolution | 0.0001 °C |
| Heat Capacity Precision | ≤0.10% RSD |
| Heat Capacity Stability | ≤0.20% drift over 12 months |
| Single Test Duration (Fast Mode) | <11 min |
| Single Test Duration (Classical Mode) | <13 min |
| Max Power Consumption | 0.65 kW |
| Supply Voltage | AC 220 V ±10%, 50 Hz ±1 Hz |
| Dimensions (Main Unit) | 428 mm × 565 mm × 450 mm |
| Weight (Main Unit) | ~45 kg |
| Water Jacket Dimensions | 220 mm × 565 mm × 410 mm |
| Water Jacket Weight | ~25 kg |
| Compliance | GB/T 213-2008, GB/T 384-1981, GB/T 30727-2014, ASTM D5865-2007, JC/T 1005-2006, ISO 1928-2020 |