Empowering Scientific Discovery

Hunan SUNDE Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSundy
OriginHunan, China
ModelSDS-V
Measurement PrincipleCoulometric Titration
Sulfur Range0.01–40 wt%
Resolution0.001 wt%
Temperature Control Accuracy±1 °C
Sample Mass~50 mg (adjustable)
Combustion Furnace Temp1150 ±5 °C (coal & coke), 900 ±5 °C (oil & pyrite), 1150–1200 °C (cement)
Test Duration~200 s per sample
Max Power3.5 kW
VoltageAC 220 V ±10%, 50 Hz ±1 Hz
Dimensions (L×W×H)680 × 520 × 395 mm
Weight~78 kg
ComplianceGB/T 214–2007, JJG 1006–2005
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSundhy
ModelSDS720
PrincipleCoulometric Titration
OriginHunan, China
Measuring Range0.01–40% S
Sulfur Resolution0.001%
Temperature Control Accuracy±1°C
Sample Mass~50 mg (adjustable)
Combustion Furnace Temperature(1150±5)°C for coal & coke
Max. Sample Capacity21 positions
Avg. Analysis Time~200 s per sample
Max. Power Consumption4 kW
Supply VoltageAC 220 V ±10%, 50 Hz ±1 Hz
Dimensions (W×D×H)610 × 890 × 410 mm
Net Weight~81 kg
ComplianceGB/T 214–2007, JJG 1006–2005
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSundhy
ModelSDIS401
Measurement PrincipleUltraviolet-Fluorescence (UVF) with Infrared Detection
Standard ComplianceGB/T 25214–2010, ISO 19579:2006, ASTM D4239–2018
Test Range0.01–50 wt% (extendable)
Analysis Time~120 s per sample
Combustion Temperature1250–1350 °C (recommended: 1300 °C)
Sample Mass200 mg (nominal)
Furnace Power4 kW
Dimensions (L×W×H)760 × 434 × 752 mm
Weight~80 kg
Power SupplyAC 220 V ±10%, 50 Hz ±1 Hz
Sample Capacity1 position (manual loading)
Detector TypeLow-drift infrared absorption cell
Gas ConditioningIntegrated desiccant and particulate filtration
Gas Path DesignPatented low-dead-volume, temperature-stabilized flow path
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSundy
OriginHunan, China
ModelSDS1600 / SDS1200
Measurement PrincipleCoulometric Titration
Sulfur Range0.01–40%
Resolution0.001%
Temperature Control Accuracy±1°C
Sample Mass~50 mg (typical)
Combustion Zone Temp(1150±5)°C for coal & coke, (900±5)°C for oil & pyrite, (1150–1200)°C for cement
Max. Sample Capacity22 positions
Avg. Analysis Time~200 s per sample
Auto WO₃ AdditionSDS1600 only
Max. Power4 kW
VoltageAC 220 V ±10%, 50 Hz ±1 Hz
Dimensions (H×W×D)410 × 890 × 610 mm
WeightSDS1600 ≈ 85 kg, SDS1200 ≈ 81 kg
ComplianceGB/T 214–2007, JJG 1006–2005