Inductively Coupled Plasma Mass Spectrometer
Filter
Showing 31–60 of 76 results
| Brand | Hiden |
|---|---|
| Origin | United Kingdom |
| Model | IMP |
| Pump Configuration | Integrated Differential Pumping Manifold |
| Mass Range | Up to 300 amu (Triple-Filtered Quadrupole) |
| Detector | Pulsed Ion Counting System |
| Energy Analyzer | Built-in with Ion Optics |
| Pressure Protection | Penning Gauge + Interlock Circuitry |
| Long-Term Stability | < ±0.5% peak height drift over 24 h |
| Communication Interfaces | RS232, RS485, Ethernet |
| Control Software | MASsoft with DDE support, Parallel Digital I/O |
| Compliance | Designed for integration into ISO/IEC 17025-compliant process monitoring environments |
| Application Scope | Real-time endpoint detection, target purity verification, residual gas analysis, leak detection, SPC-driven etch process control |
| Brand | Teledyne Photon Machines |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | IRIDIA Ultra-Fast Imaging Excimer |
| Laser Type | ArF Excimer (193 nm) |
| Repetition Rate | 300 Hz / 500 Hz |
| Ablation Cell | Cobalt™ Fast-Washout Chamber (< 5 ms aerosol washout) |
| Gas Integration | Integrated ArF pre-mixed and He gas cabinets with active pressure relief and fully enclosed design |
| Gas Management | Patented ExiCheck™ automated ArF gas exchange module |
| Optical Path | Class 1 laser safety architecture |
| Beam Delivery | Dual-polarization optics (Geo Edition) or dual-attenuator configuration (BIO Edition) |
| Mirror Lifetime | 5× extended service life via multi-use reflective optics |
| Warranty | 2 years / 2 billion shots |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | LabMS 3000 |
| Instrument Type | Quadrupole ICP-MS |
| Application Environment | Laboratory |
| Detection Principle | Inductively Coupled Plasma Ionization + Mass Separation via RF Quadrupole Filter |
| Software Platform | HiMass Intelligent Workstation |
| Safety Architecture | Five-Level Integrated Safety Protection System |
| Maintenance Logging | Automated Scheduled Maintenance Audit Trail |
| Sample Introduction | Integrated High-Matrix Sample Introduction System with On-Line Argon Dilution and Oxygen-Added Organic Sample Desolvation |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Quadrupole-based ICP-MS/MS |
| Configuration | Dual-mode (QqQ and single-quadrupole) |
| Application Domain | Laboratory-based elemental and isotopic analysis |
| Regulatory Compliance | SEMI S2 certified |
| Safety Architecture | 10-layer integrated hardware and firmware safety interlocks |
| Software Platform | HiMass Intelligent Workstation (v3.2+) |
| Ion Source | Robust 27 MHz solid-state RF generator with auto-matching plasma system |
| Interface Design | High-efficiency nickel sampler/skimmer cone assembly with active cooling |
| Ion Optics | Multi-stage electrostatic ion guide with collision/reaction cell (CRC) featuring mass-resolved reaction monitoring (MRM) capability |
| Brand | Lihero |
|---|---|
| Origin | Hunan, China |
| Model | LFMSM-2016 ICP-MS Water Auto-Analyzer |
| Mass Analyzer Type | Quadrupole Mass Spectrometer |
| Application | Field-deployable / Mobile Monitoring |
| Compliance Standard | HJ 700–2014 (China) |
| Filtration | Automated 0.45 µm Disposable Belt Filter |
| Elemental Coverage | Up to 66 Elements (Including As, Cd, Cr, Cu, Hg, Pb, Zn, Se, Ni, Mn, Fe, etc.) |
| Analysis Time per Sample | 3–5 min (steady-state operation) |
| Detection Capability | Sub-ppt Level for Key Elements |
| Operational Modes | Dissolved Fraction Analysis & Total Element Analysis (with Onboard Acid Digestion Option) |
| Brand | NCS |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Quadrupole ICP-MS |
| Application Environment | Laboratory |
| Mass Resolution (Full Width at Half Maximum, FWHM) | ≤0.8 amu |
| Detection Limits (ng·L⁻¹) | Be ≤ 2 |
| Sensitivity (Mcps / mg·L⁻¹) | Be ≥ 6 |
| Brand | NCS |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | PlasmaMS 400 |
| Instrument Type | Quadrupole ICP-MS |
| Application Environment | Laboratory |
| Mass Range (amu) | 2–260 |
| Resolution (Unit Mass Resolution, amu) | 0.3–1.0 (Continuously Adjustable) |
| Detection Limits (ng·L⁻¹) | Be ≤ 0.5 |
| Sensitivity (Mcps/mg·L⁻¹) | Li > 80 |
| Short-Term Stability (RSD) | ≤ 2% |
| Long-Term Stability (RSD) | ≤ 3% |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | DRC-e |
| Mass Analyzer Type | Quadrupole |
| Resolution (FWHM at m/z 202) | ≤ 0.8 amu |
| Detection Limit | sub-ppq ng·L⁻¹ |
| Sensitivity | Be ≥ 5 Mcps/(mg·L⁻¹), In ≥ 30 Mcps/(mg·L⁻¹), Bi ≥ 20 Mcps/(mg·L⁻¹) |
| Vacuum System | Dual mechanical pumps + dual turbo-molecular pumps (total pumping speed > 380 L/min) |
| Linear Dynamic Range | 9 orders of magnitude |
| DRC Gas Options | H₂, He, CH₄, NH₃, O₂, N₂O, CO₂ |
| Interference Reduction Efficiency | > 10⁷-fold |
| Chemical Resolution | > 150,000 |
| Isotopic Ratio Precision (¹⁰⁷Ag/¹⁰⁹Ag) | < 0.08% RSD |
| Brand | PerkinElmer |
|---|---|
| Origin | Singapore |
| Manufacturer | PerkinElmer |
| Import Status | Imported |
| Model | NexION 1000G |
| Instrument Type | Quadrupole ICP-MS |
| Interface Configuration | Triple-cone interface with UltraConic™ design |
| RF Generator | Self-excited solid-state generator with LumiCoil™ technology |
| Ion Optics Architecture | Three-quadrupole tandem mass spectrometry platform (quadrupole ion deflector, quadrupole universal cell, quadrupole mass analyzer) |
| Application Scope | Environmental, geological, food & pharmaceutical, industrial QA/QC, speciation analysis |
| Brand | PerkinElmer |
|---|---|
| Origin | Malaysia |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 1000G |
| Mass Range (amu) | 20 |
| Unit Mass Resolution (amu) | 0.5 |
| Detection Limit (ng·L⁻¹) | 10 |
| Sensitivity (Mcps / mg·L⁻¹) | 10 |
| Short-Term Stability (RSD %) | 3 |
| Long-Term Stability (RSD %) | 5 |
| Mass Analyzer Type | Quadrupole |
| Application Environment | Laboratory |
| Brand | PerkinElmer |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | NexION 100G |
| Pricing | Available upon Request |
| Brand | PerkinElmer |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | NexION 1100/1000G ICP-MS |
| Instrument Type | Quadrupole Mass Spectrometer |
| Application Environment | Laboratory |
| Brand | PerkinElmer |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | NexION 2200 |
| Instrument Type | Quadrupole ICP-MS |
| Application Environment | Laboratory |
| Detection Principle | Inductively Coupled Plasma Mass Spectrometry |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NexION 300 |
| Instrument Type | Quadrupole Mass Spectrometer |
| Mass Resolution (FWHM at 202Hg) | ≤ 0.8 amu |
| Detection Limit | sub-ppq ng·L⁻¹ |
| Sensitivity (Mcps / mg·L⁻¹) | Be ≥ 5, In ≥ 30, Bi ≥ 20 |
| Brand | PerkinElmer |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | NexION 5000 |
| Instrument Type | Quadrupole-based ICP-MS |
| Application Environment | Laboratory |
| Brand | EXPECLIN / Puju Medical |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Domestic Product Classification | Domestic |
| Model | PreMed 7000 |
| Pricing | Available Upon Request |
| Brand | Rayleigh |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China-made) |
| Model | Elementis QQ Series |
| Instrument Type | Quadrupole Mass Spectrometer |
| Application Environment | Laboratory |
| Detection Principle | Inductively Coupled Plasma Ionization + Mass Separation via RF Quadrupole Filter |
| Detector | Digital/Analog Dual-Mode Electron Multiplier |
| Dynamic Range | 9–10 orders of magnitude |
| Mass Analyzer Material | Pure Molybdenum Quadrupole Rods |
| Ion Source | Self-Excited All-Solid-State RF Generator (Frequency-Matched Tuning) |
| Sample Introduction | Split-Type Torch with Auto-Alignment |
| Nebulizer Cooling | Thermoelectrically Cooled (TEC) Spray Chamber |
| Gas Control | On-line Argon Dilution System |
| Optional Oxygen Addition | Independent O₂ Combustion Module |
| Collision/Reaction Cell | Patented Hybrid Electric Field Collision/Reaction Cell (KED, CRC, and MR Mode Support) |
| Brand | Savillex |
|---|---|
| Origin | USA |
| Model | Compatible with Agilent 7500 Series |
| Nebulizer Type | PFA Concentric (C-Flow) & Cross-Flow (X-Flow) |
| Nominal Uptake Rate | 200 µL/min (C-Flow), 50 µL/min (C-Flow Low-Flow Option) |
| Material | 100% Perfluoroalkoxy (PFA), O-Ring-Free Construction |
| Torch Interface | Push-Fit Connector for Agilent ICP-MS Torch |
| Compliance | Fully Compatible with ASTM D5673, ISO/IEC 17025 Trace Metal Analysis Protocols, USP <232>/<233> Elemental Impurities Testing |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | ICPMS-2030 |
| Mass Analyzer Type | Quadrupole |
| Gas Requirement | Standard-grade Argon (99.95%) |
| Plasma Gas Flow (Eco Mode) | 5 L/min |
| Plasma Gas Flow (Analysis Mode) | 10 L/min |
| Torch Configuration | Mini-torch |
| Software Platform | LabSolution DB/CS ICPMS |
| Regulatory Compliance | FDA 21 CFR Part 11, ERES, GLP/GMP-ready |
| Interface Compatibility | LC-ICP-MS, HPLC, GC, UV, FTIR, TOC, and other lab instruments |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported Instrument |
| Model | ICPMS-2030 Series |
| Instrument Type | Quadrupole Mass Spectrometer |
| Plasma Gas Consumption (Standard Mode) | 10 L/min |
| Plasma Gas Consumption (Eco Mode, Standby) | 5 L/min |
| Carrier Gas Purity Requirement | Standard Argon (99.95%) |
| Software Compliance | FDA 21 CFR Part 11, ERES, GLP/GMP Audit Trail Ready |
| LC-ICP-MS Compatibility | Yes |
| Collision Cell Technology | Integrated Quadrupole-Based Collision/Reaction Cell |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model Series | ICPMS-2040/2050 |
| Instrument Type | Quadrupole Mass Spectrometer |
| Mass Range (amu) | 5–260 |
| Unit Mass Resolution (amu) | 0.3–0.6 |
| Short-Term Stability (RSD) | ≤3% |
| Long-Term Stability (RSD) | ≤3% |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Line | ICP-MS 2000 Series |
| Mass Analyzer Type | Quadrupole Mass Spectrometer |
| Intended Use | Laboratory-Based Elemental Analysis |
| Regulatory Compliance | Meets or exceeds GB/T 35791–2018 (Chinese National Standard for ICP-MS Performance Verification) |
| Software Platform | Windows 2000/XP/Vista/7 (32-bit & 64-bit) Compatible Control System |
| Sample Introduction | Integrated Peltier-Cooled Glass Cyclonic Spray Chamber (–20 °C to +20 °C), One-Piece Quartz Concentric Torch, Open-Access Nebulizer Assembly |
| Vacuum Interface | Dual-Conical Interface with Removable Sampling Cone (1.1 mm orifice) and High-Salt/High-Sensitivity Skimmer Cone Options (0.75 mm standard) |
| Ion Optics | Asymmetrically Mounted Extraction & Deflection Lenses, ETP Dual-Mode Detector (Analog/Digital Switching), Computer-Controlled Auto-Tuning |
| Automation | 250-Position Autosampler (Ethernet-Controlled, Positioning Accuracy < 500 µm) |
| RF Generator | Solid-State Frequency-Tunable Generator with Cold Plasma Mode, Collision/Reaction Cell Mode, and Standard Mode Support |
| Collision/Reaction Cell | Hexapole-Based, H₂/He Mixed-Gas KED Mode Enabled |
| Detection Modes | Full-Scan, Peak-Hopping, Time-Resolved Analysis (TRA) |
| Brand | EXPEC (Hangzhou Puyu Technology Co., Ltd.) |
|---|---|
| Origin | Zhejiang, China |
| Instrument Type | Quadrupole ICP-MS |
| Configuration | Integrated Glovebox-Coupled System |
| Application Environment | Laboratory-Based Elemental Analysis |
| Regulatory Compliance | Designed for GLP/GMP-aligned workflows, compatible with ISO/IEC 17025 method validation frameworks |
| Sample Handling | Fully enclosed, operator-isolated glovebox integration (vacuum/negative-pressure/ultra-clean operation) |
| Matrix Tolerance | Direct analysis of up to 10% total dissolved solids (TDS) |
| Detection Limit | Sub-ppt (ng/L) for key isotopes under optimized conditions |
| Ion Source | Self-excited all-solid-state RF generator with argon plasma stabilization |
| Interface Design | Aerodynamically optimized ion optics at plasma–vacuum boundary |
| Collision/Reaction Cell | Integrated dynamic reaction cell (DRC) with multi-gas capability (He, H₂, NH₃, O₂) |
| Automation Readiness | Compatible with EXPEC automated inorganic sample preparation platforms |
| Brand | SPECTRO |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | SPECTROGREEN MS |
| Instrument Type | Quadrupole ICP-MS |
| Application Environment | Laboratory |
| Mass Range | 4–255 amu |
| Unit Mass Resolution | 0.2–0.66 amu |
| Detection Limit | Sub-ppt (ng·L⁻¹) |
| Sensitivity | Co ≥ 360 Mcps/(mg·L⁻¹), Y ≥ 400 Mcps/(mg·L⁻¹) |
| Short-Term Stability (RSD) | <1% |
| Long-Term Stability (RSD) | <2% |
| Brand | SpectrUM / EXPEC |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | EXPEC 7200 |
| Instrument Type | Quadrupole ICP-MS |
| Application Environment | Laboratory |
| Mass Range (amu) | 1–280 |
| Resolution (Unit Mass Resolution, amu) | ≤0.75 |
| Detection Limit (ng·L⁻¹) | <0.05 for ⁹Be, <0.003 for ²³⁸U |
| Sensitivity (Mcps/mg·L⁻¹) | >350 for ²³⁸U |
| Short-Term Stability (RSD, 10 min) | <2% |
| Long-Term Stability (RSD, 2 h) | <3% |
| Brand | EXPEC |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic Instrument |
| Model | SUPEC 7000 |
| Instrument Type | Quadrupole ICP-MS |
| Application Environment | Laboratory-Based Analysis |
| Key Features | High-Temperature Gas Flow Control, Multi-Stage Gradient Vacuum System, High-Efficiency Ion Interface, Distributed Collision/Reaction Cell, Temperature- and Humidity-Stable Quadrupole Mass Analyzer |
| Compliance Context | Designed for GLP/GMP-aligned laboratories |
| Software Platform | EXPEC ICP-MS Control Suite v3.2 (with method validation templates, QC flagging, and raw data integrity logging) |
| Brand | EXPEC |
|---|---|
| Origin | Zhejiang, China |
| Model | SUPEC 7010 |
| Instrument Type | Quadrupole ICP-MS |
| Application Domain | Laboratory & Environmental Monitoring |
| Compliance | HJ 700–2014 |
| Automation Level | Fully Automated Sample Intake, Filtration, Pre-treatment, Analysis, QC, and Data Transmission |
| Detection Scope | Multi-element (As, Cd, Cr, Cu, Hg, Ni, Pb, Zn, etc.) in Surface Water, Groundwater, Drinking Water, and Seawater |
| Measurement Time per Sample | <5 min |
| Interference Resistance | High (immune to color, turbidity, matrix-induced polyatomic interferences via collision/reaction cell technology) |
| Environmental Profile | Low reagent consumption, no electrode wear, near-zero liquid waste generation |
| Regulatory Alignment | Designed for GLP-compliant operation |
| Brand | FPI (Focus Photonics Inc.) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Quadrupole ICP-MS |
| Application Environment | Laboratory |
| Automation Level | Full End-to-End Sample-to-Result Automation |
| Sample Forms Supported | Solid and Liquid Matrices |
| Acid Compatibility | HNO₃, HCl, HF, HClO₄ |
| Volumetric Accuracy | <0.025 mL (5–50 mL range) |
| Sample Introduction | Integrated Auto-Sampling with In-Line Filtration |
| Safety Features | Auto-Ignition, Auto-Optimization, Auto-Quenching, Acid-Fume Extraction, Corrosion-Resistant Fluidic Pathways |
| Calibration & QC | Auto-Standard Curve Generation, Multi-Point QC Triggering (LOD, Blank, CRM), Adaptive Response Logic (Re-run / Skip / Abort) |
| Data Interface | Real-Time CPS/Concentration/RSD Dashboard, Interactive Calibration Plotting, Outlier Flagging |
| Brand | EXPEC |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | SUPEC 7030 |
| Instrument Type | Quadrupole ICP-MS |
| Application Environment | Laboratory & Continuous Ambient Air Monitoring |
| Detection Mode | Online Automated ICP-MS Analysis with Integrated Sample Preparation |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China-manufactured) |
| Model | iCAP MSX |
| Configuration | Single-Quadrupole ICP-MS |
| Energy Efficiency | Enhanced power management & reduced standby consumption |
| Packaging | FSC-certified materials, minimal plastic, recyclable transport crates |
| Unit Size | Each |