Industrial Particle Size Analyzer
Filter
Showing 1–30 of 38 results
| Brand | Pharmsteri (Intertek) |
|---|---|
| Origin | USA |
| Model | AccuSizer Mini |
| Detection Principle | Single Particle Optical Sensing (SPOS) with LE/LS/FX/FX-Nano Sensor Options |
| Particle Size Range | 0.15–400 µm (configurable by sensor) |
| Concentration Range | Up to 1×10⁶ particles/mL (FX/FX-Nano with auto-dilution) |
| Resolution | 512 channels |
| Minimum Detectable Size | 150 nm (FX-Nano) |
| Sample Handling | Direct, one-step, or two-step automated dilution |
| Compliance | Designed for GLP/GMP environments |
| Interface | PLC-compatible digital I/O |
| Power | 100–240 VAC, 3-phase, C14 inlet |
| Pneumatic Supply | 3.5–5.6 kg/cm² (50–80 psi) |
| Liquid Inlet/Outlet Pressure | 0.2–2.1 kg/cm² (3–30 psi) / zero-backpressure discharge |
| Dimensions | 863.6 × 355.6 × 279.4 mm (34 × 14 × 11 in) |
| Brand | Bettersize |
|---|---|
| Model | BT-Online1 |
| Measurement Principle | Mie Scattering Theory (default), Fraunhofer Diffraction Theory (optional) |
| Particle Size Range | 0.1–1000 µm |
| Accuracy & Repeatability | ≤1% D50 deviation against NIST-traceable or ISO-certified reference standards |
| Laser Source | High-power fiber-coupled laser |
| Detector Array | 68-element photodiode array (forward + side scattering) |
| Optical Design | Positive Fourier transform optical system |
| Sampling Methods | Venturi negative-pressure sampling via笛-type probe or auger sampler |
| Lens Protection | Dual-layer aerodynamic air curtain |
| Dispersing Medium | Compressed air or inert gas (N₂), 0.1–0.8 MPa |
| Test Interval | Continuous or user-defined discrete intervals (minimum 1 s) |
| Monitoring Channels | 1–4 independent process lines (1:1 to 1:4 configuration) |
| Dispersion Modes | Standard (e.g., cement) and high-energy (e.g., alumina, hard ceramic powders) |
| Ingress Protection | IP65 |
| Output Interfaces | Modbus-RTU, Modbus-TCP, 4–20 mA analog output |
| Data Security Compliance | FDA 21 CFR Part 11 (audit trail, electronic signature, role-based access) |
| Standards Compliance | ISO 13320:2020, GB/T 19077–2024, GB/T 41949–2022, GB/T 19077–2016, ISO 13320:2009, Q/ASA 001–2021 |
| Power Supply | 100–240 VAC, 50/60 Hz, 3 A |
| Measured Parameters | Full size distribution, D10/D50/D90/D97/D98, volume-weighted mean diameter D[4,3], surface-area-weighted mean diameter D[3,2], specific surface area, and user-definable fraction content (e.g., <3 µm, 3–32 µm, >45 µm, >80 µm) |
| Brand | Bettersize |
|---|---|
| Model | BT-Online1A |
| Measurement Principle | Mie Scattering Theory (default), Fraunhofer Diffraction Theory (optional) |
| Particle Size Range | 0.1–2000 µm |
| Accuracy & Repeatability Error | ≤0.5% (D50 deviation against NIST-traceable or ISO-certified reference standards) |
| Optical System | Dual-path Fourier-optics architecture (patented forward + reverse Fourier configuration) |
| Detector Array | 92-channel photodetector (forward, side, and backward scattering) |
| Laser Source | High-power fiber-coupled laser |
| Sampling Methods | Venturi negative-pressure sampling (direct pipe insertion), auger-assisted Venturi sampling, or concentrator-enhanced Venturi sampling |
| Lens Protection | Dual-layer aerodynamic air curtain |
| typical maintenance-free interval | 12 months |
| Dispersion Medium | Compressed air or inert gas (N₂), 0.1–0.8 MPa |
| Test Interval Modes | Continuous measurement or programmable interval (minimum 1 s) |
| Monitoring Channels | 1–4 independent process lines (1-to-N configuration) |
| Dispersion Modes | Standard dispersion (e.g., cement) and high-energy dispersion (e.g., alumina, hard ceramics) |
| Enclosure Rating | IP65 |
| Output Interfaces | Modbus-RTU, Modbus-TCP, 4–20 mA analog output |
| Data Integrity Compliance | FDA 21 CFR Part 11 (audit trail, electronic signatures, role-based access control) |
| Standards Compliance | ISO 13320:2020, GB/T 19077–2024, GB/T 41949–2022 |
| Power Supply | AC 220 V, 50/60 Hz, 200 W |
| Reporting Parameters | Full size distribution, D10/D50/D90/D97/D98, volume-weighted mean D[4,3], surface-weighted mean D[3,2], specific surface area, and user-defined size fraction contents (e.g., <3 µm, 3–32 µm, >45 µm, >80 µm) |
| Brand | Bettersize |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | BT-Online2 |
| Pricing | Upon Request |
| Measurement Range | 0.02–2000 µm |
| Principle | Mie Scattering Theory (default), Fraunhofer Diffraction Theory (optional) |
| Accuracy & Repeatability | ≤0.5% D50 deviation vs. NIST/ISO reference standards |
| Calibration | Built-in standard sample verification protocol |
| Laser Source | High-power fiber-coupled laser |
| Detector Array | 92-element photodetector array (forward, side, and backward scattering) |
| Optical Design | Patented dual-path Fourier/inverse-Fourier hybrid optical system with tilted flow cell |
| Sampling Methods | (1) Peristaltic pump + direct suction probe |
| Minimum Test Interval | 3 min (including cleaning & priming) |
| Dispersion System | 600 mL recirculating chamber |
| Purified Water System | 40 L capacity with auto-refill, temperature stabilization (±0.5 °C), and filtration |
| Solvent Recovery System | Closed-loop solvent storage, filtration, and reuse circuit |
| Monitoring Channels | 1–4 parallel process streams (1:1 to 1:4 configuration) |
| Output Interfaces | Modbus-RTU, Modbus-TCP, 4–20 mA analog output |
| Data Integrity Compliance | FDA 21 CFR Part 11 (audit trail, electronic signature, role-based access) |
| Standards Conformance | ISO 13320:2020, GB/T 19077–2024, GB/T 41949–2022 |
| Power Supply | AC 220 V, 50/60 Hz, 200 W |
| Key Reported Metrics | D10, D50, D90, D97, D98, D[4,3], D[3,2], span, distribution trend plots |
| Brand | BlazeMetrics |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Blaze Basic Micro |
| Pricing | Upon Request |
| Measurement Range | 230 µm – 4.4 mm |
| Number of Optional Lenses | 1 |
| Sample Dispersion Method | In-line liquid-phase measurement / in-situ reaction system monitoring |
| Image Resolution Precision | Sub-nanometer (optical resolution limited by diffraction |
| Measured Parameters | High-resolution micro-imaging, turbidity, chord-length-based particle size and count distribution, integrated Raman spectroscopy |
| Brand | Dantec Dynamics |
|---|---|
| Origin | Denmark |
| Model | IDS |
| Measurement Principle | Shadowgraphy (Optical Silhouette Imaging) |
| Particle Size Range | 1–90 µm (volume-equivalent spherical diameter, 0.0005–381 pL) |
| Size Resolution | < 0.1 µm |
| Velocity Range | 0–60 m/s |
| Velocity Components Measured | 2D (in-plane) |
| Max Sampling Frequency | 150 kHz |
| Droplet Sphericity Assessment | Yes |
| Particle Capture Efficiency | ~100% (at optimal setup) |
| Drift Sensitivity | Low (robust to axial spray drift) |
| Real-time Control Output Interface | Yes (analog/digital, compatible with PLC/DCS) |
| Compliance | Designed for industrial GLP/GMP-adjacent environments |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | EyeTech Online Oil-in-Water Analyzer |
| Price | Upon Request |
| Measurement Parameters | Particle Size & Shape |
| Concentration Range | 0–2000 ppm |
| Particle Size Range | 2–300 µm |
| Accuracy | ±4% or ±4 ppm |
| Sample Temperature | 2–120 °C |
| Sample Pressure | Up to 20 bar |
| Automation Level | Fully Automatic |
| Cleaning System | Integrated Thermal Boosted Water Wash |
| Real-time Output | Alarm triggers on oil concentration threshold, particle size threshold, and wash pressure failure |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | EyeTech Online Particle Size and Shape Analyzer |
| Pricing | Available Upon Request |
| Brand | SOLGE |
|---|---|
| Origin | South Korea |
| Model | Solge EZ-LubeCheck |
| Type | Portable In-Field Oil Moisture Analyzer |
| Power | Integrated Rechargeable Battery |
| Measurement Principle | Capacitive Dielectric Spectroscopy |
| Output | % Water by Volume (v/v) and ppm (optional calibration) |
| Compliance | Designed for ISO 4406, ASTM D6304 (Karl Fischer correlation), and OEM lubrication condition monitoring protocols |
| [Brand | LightQ / Acona |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Model | Acona LE Mini |
| Pricing | Upon Request] |
| Brand | LISICO |
|---|---|
| Model | Online 1 |
| Measurement Principle | Mie & Fraunhofer Light Scattering |
| Test Range | 0.1–1000 µm |
| Repeatability Error | ≤1% (D50 of certified reference material) |
| Accuracy Error | ≤1% (D50 of certified reference material) |
| Sampling Method | Venturi-based negative-pressure sampling with anti-clogging design |
| Lens Protection | Dual-air-curtain optical protection |
| Maintenance Interval | ≥180 days |
| Laser Source | Imported semiconductor laser |
| Detector Array | 68-element photodiode array |
| Operating System | Windows |
| Communication Protocols | Modbus RTU, TCP/IP, 4–20 mA analog output |
| Dispersing Medium | Compressed air or inert gas (N₂) |
| Gas Supply | 0.4–0.8 MPa, ≥1000 L/min |
| Filtration System | 4-stage imported precision filter (particulate, oil, moisture removal) |
| Sample Throughput | 2–20 g per cycle |
| Power Supply | AC 220 V, 50/60 Hz, 90 W |
| Enclosure Rating | IP65 |
| Dimensions (H×W×D) | 800 × 280 × 280 mm |
| Weight | 21 kg |
| Compliance | GB/T 19077–2016, ISO 13320:2009, Q/ASA 001–2021 |
| Brand | LISICO |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Category | Domestic (China) |
| Model | Online 2 |
| Pricing | Upon Request |
| Brand | Malvern PANalytical |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Insitec |
| Pricing | Available upon Request |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | EasyViewer |
| Pricing | Upon Request |
| Viewing Field | 1 mm × 1 mm |
| Resolution Accuracy | 1.5 µm |
| Fiber Optic Cable Length | 3 m (standard), 13 m (with USB extender) |
| Weight | 0.66 kg (probe + fiber assembly) |
| Probe Operating Temperature | −20 °C to 135 °C |
| Maximum Pressure Rating | 0–10 bar |
| Probe Housing Material | Hastelloy C-22 |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | ParticleTrack G400 / G600 / G600B / G600EX |
| Measurement Principle | Focused Beam Reflectance Measurement (FBRM) |
| Particle Size Range | 0.5–2000 µm |
| Laser Class | Class 1 |
| Probe Pressure Rating | 3–300 barg (model-dependent) |
| Probe Temperature Rating | −80 to +150 °C (model-dependent) |
| Scan Speed | 2 m/s (1.2 m/s for 19 mm probe) |
| Probe Window Material | Sapphire |
| Sealing Material | Viton™ (G400), Kalrez® (G600 series) |
| Enclosure Rating | IP66 (G600B/G600EX) |
| Compliance | CE, NRTL, CB Scheme, FDA 21 CFR Part 11 (with iC Process software), GLP/GMP-ready |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TP791 |
| Pricing | Available Upon Request |
| Measurement Principle | Light Obscuration (LO) per ISO 11171 & ISO 4406 |
| Detection Range | 0.8 µm to 600 µm (sensor-dependent) |
| Accuracy | ±0.5% |
| Repeatability (RSD) | <2% |
| Resolution | <10% |
| Operating Temperature | 0–60 °C |
| Light Source | Semiconductor Laser |
| Number of Measurement Channels | 16 (user-configurable size thresholds within calibrated range) |
| Sample Flow Rate | 5–80 mL/min |
| Coincidence Limit | 12,000–24,000 particles/mL (sensor-dependent) |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Power Consumption | ≤200 W |
| Dimensions (Main Unit) | 360 × 370 × 700 mm |
| Dimensions (Air Pump) | 330 × 266 × 255 mm |
| Weight (Main Unit) | 30 kg |
| Weight (Air Pump) | 10 kg |
| Brand | OMEC |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | OMEC At-line |
| Pricing | Upon Request |
| Brand | PSS (Particle Sizing Systems) |
|---|---|
| Origin | USA |
| Model | A7000 Online |
| Detection Principle | Single Particle Optical Sizing (SPOS) |
| Dilution System | Integrated Automated Dilution Module |
| Sampling Mode | Timed Automatic In-Line Sampling |
| Alarm Capability | Real-Time Threshold-Based Alerting |
| Data Output | Concentration-Compensated Raw Counts & Size Distribution |
| Compliance Framework | Supports GLP/GMP Data Integrity Requirements (21 CFR Part 11 Ready via Optional Software Configuration) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | OPC Economy Edition |
| Price | USD 8,100 (FOB) |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Particle Size Range | 1–150 µm |
| Number of Channels | 8 |
| Standards Supported | NAS 1638, ISO 4406, SAE AS4059, ISO 11171, MIL-STD-1246D, GJB 420B, GOST 17216, GB/T 14039, DL/T 432, DL/T 1096, JB/T 9737, GB/T 18854 |
| Operating Pressure | 0–1.0 MPa (standard), up to 31.5 MPa (with integrated pressure reducer) |
| Flow Rate | 15–500 mL/min |
| Fluid Temperature Range | −10 °C to +80 °C |
| Viscosity Range | 0–500 cSt |
| Output Interfaces | RS232, RS485, 4–20 mA, 0–5 V (customizable) |
| Power Supply | 9–30 VDC |
| Enclosure Rating | IP65 (industrial-grade rugged housing) |
| Brand | PULUODY |
|---|---|
| Model | OPC |
| Origin | Shaanxi, China |
| Detection Principle | Light Obscuration (LO) with Dual-Laser Narrow-Beam Technology |
| Measurement Range | 1–150 µm |
| Calibration Standards Supported | ISO 4406, NAS 1638, SAE AS4059, ISO 11171, MIL-STD-1246C, GB/T 14039, DL/T 432, GJB/T 420A/B, GB/T 18854 |
| Operating Pressure | 0–0.6 MPa (standard), up to 31.5 MPa (with integrated pressure regulator) |
| Sample Flow Rate | 6–500 mL/min |
| Fluid Temperature Range | −10 °C to +80 °C |
| Viscosity Limit | ≤500 cSt (online mode) |
| Output Interfaces | 4–20 mA analog, RS232 serial, optional alarm relay |
| Power Supply | 9–30 VDC |
| Compliance | Designed for industrial process monitoring per ISO 21501-4, ASTM D6786, and IEC 61508 SIL2-ready architecture |
| Enclosure Rating | IP65 (standard), optional IP67 |
| Software | Integrated firmware with configurable reporting (particles/mL + contamination code) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | OPC-1 |
| Price | USD 8,200 (FOB) |
| Detection Principle | Light Blockage (Optical Obscuration) |
| Measurement Range | 1–150 µm |
| Calibration Standard Compliance | ISO 11171:2016, ISO 4402:1991 (Annex A), NAS 1638, ISO 4406:2021, SAE AS4059F, MIL-STD-1246C, GB/T 18854–2015 |
| Operating Pressure | 0–0.6 MPa (standard), up to 31.5 MPa (with integrated pressure regulator) |
| Flow Rate | 6–500 mL/min |
| Fluid Temperature Range | −10 °C to +80 °C |
| Viscosity Limit | ≤500 cSt (online mode) |
| Output Interfaces | 4–20 mA analog, RS232 serial, optional relay alarm |
| Power Supply | 9–30 VDC |
| Enclosure Rating | IP65 |
| Regulatory Compliance | CE, RoHS, FDA 21 CFR Part 11 ready (via software audit trail) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | OPC-2300 |
| Price | USD 13,800 (FOB) |
| Detection Principle | Light Obscuration (LO) |
| Sensor Type | 7th-Generation Dual-Laser Narrow-Beam Optical Sensor |
| Measurement Range Options | 0.1–1.0 µm (H), 0.2–2.0 µm (I), 0.5–50.0 µm (J), 1–150 µm (B), 2–100 µm (A), 2–750 µm (K), 40–1000 µm (L), 50–1000 µm (N), 100–2000 µm (M) |
| Customizable Sizing Ranges | 1–100 µm, 2–125 µm, 2–250 µm, 5–500 µm, or fully user-defined |
| Output Interfaces | RS-232, 4–20 mA analog signal |
| Display | Integrated LCD with membrane keypad |
| Enclosure Rating | IP65 industrial housing |
| Operating Pressure | Up to 10 bar |
| Temperature Range | 0–60 °C |
| Compliance | Supports ASTM D6786, ISO 4406, ISO 11171, ISO 11943, USP <788>, and customizable regulatory logic per client specification |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | OPC-2300A |
| Detection Principle | Light Obscuration (LO) with Dual-Laser Narrow-Beam Technology (7th Generation) |
| Sensor Options | A (2–100 µm), B (1–150 µm), C (1–450 µm), H (0.1–1.0 µm), I (0.2–2.0 µm), J (0.5–50.0 µm), K (2–750 µm / 2–800 µm / 5–1000 µm), L (40–1000 µm / 10–2000 µm), N (50–1000 µm), M (100–2000 µm) |
| Sizing Range (Standard) | 1–100 µm, 2–125 µm, 2–250 µm, 5–500 µm |
| Channel Resolution | 0.1 µm |
| Resolution | 10% (per ISO 21501-4) |
| Accuracy | < ±3% typical (NIST-traceable latex standard calibration) |
| Coincidence Error | ≤5% at 999,999 particles/mL |
| Maximum Detectable Concentration | 9,999,999 particles/mL |
| Sampling Interval | 5 s – 9 h (programmable) |
| Calibration Standards | NIST-traceable polystyrene latex (PSL) spheres, AC fine test dust, MTD (Medium Test Dust) |
| Operating Pressure | 0–0.6 MPa (standard) |
| Flow Rate | 6–500 mL/min |
| Output Interfaces | RS-232, 4–20 mA analog, optional Ethernet/Modbus TCP |
| Display | Integrated LCD with membrane keypad |
| Environmental Rating | IP65 enclosure |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | OPC-2300D |
| Detection Principle | Light Obscuration (LO) with Dual-Laser Narrow-Beam Technology |
| Sensor Options | A (2–100 µm), B (1–150 µm), C (1–450 µm), H (0.1–1.0 µm), I (0.2–2.0 µm), J (0.5–50.0 µm), K (2–750 µm / 2–800 µm / 5–1000 µm), L (40–1000 µm / 10–2000 µm), N (50–1000 µm), M (100–2000 µm) |
| Sizing Range (Configurable) | 1–100 µm, 2–125 µm, 2–250 µm, 5–500 µm |
| Channel Resolution | Up to 1000 user-selectable channels (e.g., 8/16/32 bins) |
| Resolution | 0.1 µm |
| Counting Accuracy | < ±3% typical |
| Coincidence Error | ≤5% at 999,999 particles/mL |
| Maximum Detectable Concentration | 9,999,999 particles/mL |
| Sampling Interval | 5 s – 9 h |
| Calibration Standards | NIST-traceable latex spheres, AC fine test dust, or MTD |
| Operating Pressure | 0–0.6 MPa (standard) |
| Flow Rate | 6–500 mL/min |
| Fluid Temperature Range | −10 °C to +80 °C |
| Interface Options | Customizable compression fittings or flanged connections |
| Output Signals | RS-232 serial, 4–20 mA analog, optional Ethernet/Modbus TCP |
| Display | Integrated LCD with membrane keypad |
| Enclosure Rating | IP65 (standard), optional IP67 for harsh environments |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | OPC-2300F |
| Detection Principle | Light Obscuration (LO) / Dual-Laser Narrow-Beam Optical Sensing |
| Sensor Options | A (2–100 µm), B (1–150 µm), C (1–450 µm), H (0.1–1.0 µm), I (0.2–2.0 µm), J (0.5–50.0 µm), K (2–750 µm / 2–800 µm / 5–1000 µm), L (40–1000 µm / 10–2000 µm), N (50–1000 µm), M (100–2000 µm) |
| Sizing Range | 1–100 µm, 2–125 µm, 2–250 µm, 5–500 µm (customizable) |
| Channel Resolution | 1000-channel arbitrary binning (e.g., 8/16/32 bins) |
| Resolution | 0.1 µm |
| Counting Accuracy | < ±3% typical |
| Coincidence Error | ≤5% |
| Maximum Detectable Concentration | 9,999,999 particles/mL |
| Sampling Interval | 5 s – 9 h |
| Calibration Standards | NIST-traceable latex spheres, AC fine test dust, MTD |
| Operating Pressure | 0–0.6 MPa (standard) |
| Flow Rate | 6–500 mL/min |
| Fluid Temperature Range | −10 °C to +80 °C |
| Output Interfaces | RS-232, 4–20 mA analog, optional Ethernet/Modbus TCP |
| Housing | IP65-rated stainless steel or industrial-grade polymer |
| Compliance | Supports ISO 4406, ISO 11171, ASTM D6786, USP <788>, EP 2.9.19, and custom regulatory logic per client requirement |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | OPC-5 |
| Price | USD 8,100 (FOB) |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Measurement Range | 1–150 µm |
| Channels | 8 |
| Standards Compliance | ISO 4406, NAS 1638, SAE AS4059, ISO 11171, MIL-STD-1246D, GJB 420B, GB/T 14039, DL/T 432, GOST 17216 |
| Pressure Rating | 0–1.0 MPa (direct), 0–31.5 MPa (with integrated pressure reducer) |
| Flow Rate | 15–500 mL/min |
| Fluid Temperature | −10 to +80 °C |
| Viscosity Range | 0–500 cSt |
| Output Interfaces | RS232, RS485, 4–20 mA, 0–5 V |
| Power Supply | 9–30 VDC |
| Enclosure Rating | IP65 |
| Calibration Support | NIST-traceable reference calibration available annually |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | OPC-6 |
| Price | USD 8,100 (FOB) |
| Detection Principle | Dual-Laser Narrow-Beam Light Obscuration |
| Measurement Range | 1–150 µm |
| Channels | 8 |
| Standards Compliance | ISO 4406, NAS 1638, SAE AS4059, ISO 11171, MIL-STD-1246D, GJB 420B, GB/T 14039, DL/T 432, GOST 17216 |
| Max. Operating Pressure | 31.5 MPa (with pressure regulator) |
| Flow Rate | 15–500 mL/min |
| Fluid Temperature Range | −10 °C to +80 °C |
| Viscosity Range | 0–500 cSt |
| Output Interfaces | RS232, RS485, 4–20 mA, 0–5 V |
| Power Supply | 9–30 VDC |
| Reporting | Particles per mL + ISO/NAS/GJB Grade Code |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | OPC-7 |
| Price | USD 8,100 (FOB) |
| Detection Principle | Dual-Laser Narrow-Beam Light Obscuration |
| Measurement Range | 1–150 µm |
| Channels | 8 |
| Standards Compliance | ISO 4406, NAS 1638, SAE AS4059, ISO 11171, MIL-STD-1246D, GJB 420B, GB/T 14039, GOST 17216 |
| Pressure Rating | 0–1.0 MPa (standard), up to 31.5 MPa (with integrated pressure reducer) |
| Flow Rate | 15–500 mL/min |
| Fluid Temperature Range | −10 °C to +80 °C |
| Viscosity Limit | ≤500 cSt (online mode) |
| Output Interfaces | RS232, RS485, 4–20 mA, 0–5 V (customizable) |
| Power Supply | 9–30 VDC |
| Reporting | Particles per mL + ISO/NAS/GJB contamination code |
| Calibration Support | NIST-traceable reference materials, annual recalibration assistance provided |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | OPC-EX-1 |
| Price | USD 27,800 (approx.) |
| Detection Principle | Light Obscuration (LO) / Dual-Laser Narrow-Beam Technology (7th Generation) |
| Particle Size Range | 1–150 µm |
| Calibration Standards Supported | ISO 4406, NAS 1638, GJB 420B, GOST 17216, SAE AS4059, ISO 11171, MIL-STD-1246, IP 564/565, GB/T 14039, DL/T 432, JB/T 9737, GB/T 18854 |
| Operating Pressure | 0–1.0 MPa (standard), up to 31.5 MPa (with integrated pressure reducer) |
| Flow Rate | 15–500 mL/min |
| Fluid Temperature Range | −10 °C to +80 °C |
| Viscosity Range | 0–500 cSt |
| Output Interfaces | RS232, RS485, 4–20 mA, 0–5 V (customizable) |
| Enclosure Rating | IP40 to IP65 |
| Explosion Protection | Intrinsic Safety (Ex ia IIC T4 Ga) |
| Power Supply | 9–30 VDC |
| Reporting | Particles per mL + ISO/NAS/GJB contamination grade |
| Channel Configuration | Fixed 8-channel or 16-channel (customizable) |
| Accuracy Class | ±0.6 per ISO 21501-4 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PLD-0203-3 |
| Price | USD 27,800 (approx.) |
| Compliance | ISO 4406, NAS 1638, SAE AS4059F, GJB 420B, DL/T 432, GJB 380, ISO 11500 |
| Calibration Standards | JJG 1061, ISO 11171, ASTM F658-87 (PSL), GB/T 18854 |
| Detection Principle | Light Obscuration (LO) |
| Laser Source | 7th-generation dual-laser narrow-beam sensor |
| Measurement Range | 0.03 µm – 3000 µm (configurable sensor modules) |
| Channel Count | Up to 1000 resolution channels |
| Sensitivity | 1 µm (ISO 4402) / 4 µm(c) (ISO 11171, GB/T 18854) |
| Accuracy | < ±3% |
| Sample Volume Precision | ±1% |
| Max. Online Pressure | 31.5 MPa (with pressure regulator) |
| Viscosity Range | Offline ≤99 mm²/s |
| Flow Rate | Sampling 5–60 mL/min |
| Operating Temp. | Sample 20–65°C |
| Power | 220 VAC, 50 Hz, <80 W |
| Data Storage | Up to 6000 test records |
| Output Interfaces | RS232, RS485, USB, 4–20 mA, 0–5 V, MODBUS |
| Regulatory Certification | CALIBRATED by NW National Metrology Center (civil) or CMC Level-1 Particle Metrology Station (defense) |