Industry-specific Instruments
Filter
Showing 3301–3330 of 6412 results
| Brand | LOGAN |
|---|---|
| Origin | USA |
| Model | FDC-6TA |
| Heating Method | Water-Jacketed Temperature Control |
| Sample Orientation | Vertical (Upright) |
| Bubble-Elimination Function | Integrated Air-Release Mechanism |
| Dual-Zone Independent Temperature Control | Yes (2 zones × 3 stations each) |
| Light-Blocking & Insulated Lid | Standard |
| Dose Volume Adjustment | Via Interchangeable Silicone Gasket Sets (Multiple Aperture Sizes) |
| Application Scope | In vitro Permeation Testing (IVPT) and In vitro Release Testing (IVRT) of Semi-Solids, Topical Dosage Forms, and Cosmetic Formulations |
| Brand | LOGAN |
|---|---|
| Origin | USA |
| Model | HDT-400L |
| Compliance | USP <1217>, ChP 0931, EP 2.9.8 |
| Measurement Range | 0–400 N (adjustable in 0.1 N increments) |
| Resolution | 0.1 N |
| Thickness Range | 1–25 mm |
| Diameter Range | 3–25 mm |
| Display | High-contrast LED |
| Output | RS-232 interface for printer or PC |
| Calibration | Internal reference load cell with NIST-traceable calibration certificate included |
| Power | 100–240 VAC, 50/60 Hz |
| Brand | LOGAN |
|---|---|
| Origin | USA |
| Model | MDS-600PL |
| Application | Automated, temperature-controlled, deaerated solvent delivery for dissolution testing |
| Mobility | Floor-standing, castor-mounted mobile platform |
| Solvent Compatibility | Aqueous buffers, surfactant-containing media (e.g., SDS, polysorbates), organic-aqueous mixtures |
| Delivery Capacity | Up to 1000 mL per vessel |
| Throughput | Simultaneous delivery to 6 dissolution vessels in ≤2 minutes |
| Temperature Control | Integrated pre-heating module (range: 25–45 °C, ±0.5 °C stability) |
| Deaeration Method | Vacuum-assisted membrane degassing |
| Dissolved Oxygen Monitoring | Built-in electrochemical DO sensor (range: 0–20 mg/L, resolution: 0.01 mg/L) |
| User Interface | 7-inch capacitive touchscreen with intuitive parameter configuration and real-time status feedback |
| Cleaning Design | Conical reservoir geometry with full-drain capability and smooth-surface wetted path |
| Regulatory Alignment | Designed to support USP <711>, <1092>, and FDA Guidance for Industry — Dissolution Testing of Immediate-Release Solid Oral Dosage Forms |
| Brand | LOGAN |
|---|---|
| Origin | USA |
| Model | PERMETRO 800 |
| Instrument Type | Offline Dissolution-Permeation System |
| Number of Vessels | 8 |
| Temperature Range | 20–60 °C |
| Temperature Accuracy | ±0.1 °C |
| Rotation Speed Range | 25–250 rpm (±1 rpm) |
| Paddle Wobble | ≤0.5 mm |
| Basket Wobble | ≤1.0 mm |
| Water Bath Temperature Range | Ambient to 45 °C |
| Water Bath Temperature Resolution | 0.1 °C |
| Water Bath Volume | 18 L |
| Brand | LOGAN |
|---|---|
| Origin | USA |
| Model | PERMETRO 800HPLC |
| Instrument Type | Online Coupled Dissolution-Permeation System |
| Number of Dissolution Vessels | 8 |
| Temperature Range (Bath & Chamber) | 20–60°C |
| Temperature Accuracy | ±0.1°C |
| Rotation Speed Range | 25–250 rpm (±1 rpm) |
| Paddle Wobble | ≤0.5 mm |
| Basket Wobble | ≤1.0 mm |
| Water Bath Temperature Range | Ambient to 45°C |
| Water Bath Temperature Resolution | 0.1°C |
| Water Bath Volume | 18 L |
| Brand | LOGAN |
|---|---|
| Origin | USA |
| Model | SDC-6 |
| Configuration | Water-jacketed horizontal diffusion cell system |
| Temperature Control | Dual-zone independent heating (each zone controls 3 diffusion cells) |
| Cell Orientation | Horizontal |
| Primary Application | In vitro permeation testing (IVPT) of ophthalmic solutions, lotions, washes, and topical formulations |
| Compliance Context | Designed to support USP <724> and OECD TG 428 guidelines |
| Brand | LOGAN |
|---|---|
| Origin | USA |
| Model | SYSTEM 4000 |
| Instrument Type | Online Flow-Through Dissolution System |
| Temperature Range | Ambient to 45 °C |
| Temperature Accuracy | ±0.1 °C |
| Flow Rate Control Modes | Constant Flow or Pulsed Flow (user-selectable) |
| Flow Cell Options | 12 mm, 22.6 mm, Powder Cell, Suppository Cell, Granule Cell |
| Number of Parallel Flow Channels | 8 |
| Bath Volume | 20 L |
| Bath Temperature Resolution | 0.1 °C |
| Shaft Wobble Tolerance (Paddle/Rotating Basket) | ≤1 mm |
| Motor Speed | 500 rpm (50 Hz), 600 rpm (60 Hz) |
| Compliance | Fully compliant with USP <4>, USP <711>, and FDA 21 CFR Part 11 requirements for audit trail, electronic signature, and data integrity |
| Brand | LOGAN |
|---|---|
| Origin | USA |
| Model | SYSTEM 850DL |
| Instrument Type | Online Dissolution Testing System |
| Dissolution Vessels | 8-position |
| Temperature Range | 20–60°C |
| Temperature Accuracy | ±0.1°C |
| Rotation Speed Range | 25–250 rpm (±1 rpm) |
| Paddle Wobble | ≤0.5 mm |
| Basket Wobble | ≤1.0 mm |
| Water Bath Temperature Control Range | Ambient to 45°C |
| Water Bath Temperature Resolution | 0.1°C |
| Water Bath Volume | 18 L |
| Brand | LOGAN |
|---|---|
| Origin | USA |
| Model | SYSTEM 850DL-12 |
| Instrument Type | Online Dissolution Tester |
| Vessel Positions | 8 or 12 |
| Temperature Range | Ambient to 45 °C ±0.1 °C |
| Rotation Speed Range | 25–250 rpm ±0.1 rpm |
| Pump Configuration | 12-channel syringe pump (12 × 10 mL) |
| Compliance | USP <711>, <724>, <723>, <725>, <731> |
| Integrated Modules | UDT-812A-12 dissolution apparatus, SCR-160L sample collector, SYP-6L 12-channel syringe pump, DSC-800D sampling controller |
| Brand | LOGAN |
|---|---|
| Origin | USA |
| Model | SYSTEM 850DLA |
| Instrument Type | Online Dissolution System |
| Number of Vessels | 8 |
| Temperature Range | 20–60 °C |
| Temperature Accuracy | ±0.1 °C |
| Rotation Speed Range | 25–250 rpm (±1 rpm) |
| Paddle Wobble Amplitude | ≤0.5 mm |
| Basket Wobble Amplitude | ≤1.0 mm |
| Water Bath Temperature Range | Ambient to 45 °C |
| Water Bath Temperature Resolution | 0.1 °C |
| Water Bath Volume | 18 L |
| Brand | LOGAN |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SYSTEM 860CDL |
| Instrument Type | Online Dissolution System |
| Dissolution Vessels | 12 |
| Temperature Range | 20–60 °C |
| Temperature Accuracy | ±0.1 °C |
| Rotation Speed Range | 25–250 rpm (±1 rpm) |
| Paddle Wobble Amplitude | ≤0.5 mm |
| Basket Wobble Amplitude | ≤1.0 mm |
| Water Bath Temperature Range | Ambient to 45 °C |
| Water Bath Temperature Resolution | 0.1 °C |
| Water Bath Volume | 30 L |
| Brand | LOGAN |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SYSTEM 860DL |
| Instrument Type | Online Dissolution System |
| Number of Vessels | 12 |
| Temperature Range | 20–60 °C |
| Temperature Accuracy | ±0.1 °C |
| Rotational Speed Range | 25–250 rpm (±1 rpm) |
| Paddle Wobble Amplitude | ≤0.5 mm |
| Basket Wobble Amplitude | ≤1.0 mm |
| Water Bath Temperature Control Range | Ambient to 45 °C |
| Water Bath Temperature Resolution | 0.1 °C |
| Water Bath Volume | 30 L |
| Compliance | FDA 21 CFR Part 11, GLP/GMP-ready audit trail and role-based access control |
| Brand | LOGAN |
|---|---|
| Origin | USA |
| Model | SYSTEM 860DLA |
| Instrument Type | Online Dissolution Sampling System |
| Vessel Capacity | 12-position |
| Compliance | FDA 21 CFR Part 11 (Audit Trail, Electronic Signatures, Role-Based Access Control) |
| Modular Configuration | UDT-818A Dissolution Apparatus, SCR-DL Sample Collector, SYP-12L-10mL Precision Syringe Pump, DSC-800 System Controller |
| Temperature Monitoring | 12 independent RTD probes per vessel |
| Filtration | Dual-stage inline filtration (pre- and post-sampling) |
| Fluid Handling | Auto-replenishment, isothermal media replacement, sample filtration, and volume compensation |
| Integration Capabilities | UV/Vis spectrophotometers, HPLC autosamplers, fiber-optic probes, dilution modules, and permeation systems (e.g., PAMPA, Caco-2) |
| Brand | LOGAN |
|---|---|
| Origin | USA |
| Model | SYSTEM 913A-12 |
| Configuration | Dual-FDC-6TA + SCR-DL + SYP-12L-10mL + DSC-800 Controller |
| Sample Capacity | 12 stations |
| Temperature Control | Dual-zone water-jacketed heating |
| Compliance | FDA 21 CFR Part 11 (audit trail, 3-tier user permissions) |
| Automation | Auto-degassing interface optional |
| Sampling | Programmable syringe pump (10 mL), auto-bubble purge, timed sequential sampling |
| Brand | LOGAN |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | SYSTEM 914-12 |
| Pricing | Upon Request |
| Brand | LOGAN |
|---|---|
| Origin | USA |
| Model | SYSTEM 918-12 |
| Configuration | Dual DHC-6TD dry-heated diffusion stations + SCR-DL sample collector + SYP-12L-10mL precision syringe pump + DSC-800 system controller |
| Sample Capacity | 12 parallel diffusion cells |
| Heating Method | Dry-heated (Peltier-based thermal control) |
| Temperature Monitoring | Real-time acceptor medium temperature sensing |
| Compliance | FDA 21 CFR Part 11 compliant with audit trail and three-tier user access control |
| Optional Accessories | Epidermal surface temperature probe, variable-speed magnetic stirrer modules, in-line solvent degassing unit |
| Brand | LOGAN |
|---|---|
| Origin | USA |
| Model | SYSTEM ADIS 1200 |
| Instrument Type | Online Dissolution Analyzer |
| Configuration | 12-Position Fully Automated System |
| Compliance | Designed for USP <711>, <724>, <1092>, and FDA Guidance on Dissolution Testing |
| Brand | LOGAN |
|---|---|
| Origin | USA |
| Model | SYSTEM ADR III-7 |
| Instrument Type | Online Dissolution Testing System |
| Dissolution Vessels | 8 vessels per rack × 6 racks (48 total) or 12 vessels per rack × 12 racks (144 total) |
| Temperature Range | 20–60 °C |
| Temperature Accuracy | ±0.1 °C |
| Water Bath Temperature Range | Ambient to 45 °C |
| Water Bath Temperature Resolution | 0.1 °C |
| Water Bath Volume | 28 L |
| Compliance | USP <711>, <724>, <725>, EP 2.9.3, JP 17 |
| Data Integrity | 21 CFR Part 11-compliant audit trail, role-based user access control, electronic signatures |
| Brand | LOGAN |
|---|---|
| Origin | USA |
| Model | SYSTEM UV 1900-12 |
| Instrument Type | Online Dissolution Analyzer |
| Configuration | Modular, Fully Automated 12-Station System |
| Compliance | FDA 21 CFR Part 11 (Audit Trail, Electronic Signatures, Role-Based Access Control) |
| Detection Method | UV-Vis Spectrophotometry (Fixed-Wavelength or Scanning Mode) |
| Sampling Mechanism | High-Precision Peristaltic/Injection Pump (SYP-1200 Series) |
| Temperature Monitoring | 12 Independent RTD Probes per Vessel |
| Flow Cell Pathlengths | 2 mm, 5 mm, 10 mm (Standardized to USP <711>, <724>, <731>) |
| Filtration | Dual-Stage In-Line Filtration (0.45 µm + 0.22 µm) |
| Regulatory Alignment | USP, Ph. Eur., JP, ISO 16850, ASTM E2503 |
| Brand | LOGAN |
|---|---|
| Origin | USA |
| Model | UDT-812A-12 |
| Instrument Type | Online Dissolution Tester |
| Number of Vessels | 12 |
| Temperature Range | 20–60°C |
| Temperature Accuracy | ±0.1°C |
| Rotational Speed Range | 25–250 rpm (±1 rpm) |
| Paddle Wobble Amplitude | ≤0.5 mm |
| Basket Wobble Amplitude | ≤1.0 mm |
| Water Bath Temperature Range | Ambient to 45°C |
| Water Bath Temperature Resolution | 0.1°C |
| Water Bath Volume | 18 L |
| Brand | LOGAN |
|---|---|
| Origin | USA |
| Model | UDT-812A-8 |
| Instrument Type | Online Dissolution Tester |
| Number of Vessels | 8 |
| Temperature Range | 20–60°C |
| Temperature Accuracy | ±0.1°C |
| Rotation Speed Range | 25–250 rpm (±1 rpm) |
| Paddle Wobble | ≤0.5 mm |
| Basket Wobble | ≤1.0 mm |
| Water Bath Temperature Range | Ambient to 45°C |
| Water Bath Temperature Resolution | 0.1°C |
| Water Bath Volume | 18 L |
| Brand | LOGAN |
|---|---|
| Origin | USA |
| Model | UDT-818A-12 |
| Instrument Type | Online Dissolution Tester |
| Number of Vessels | 12 |
| Temperature Range | 20–60°C |
| Temperature Accuracy | ±0.1°C |
| Rotation Speed Range | 25–250 rpm (±1 rpm) |
| Paddle Wobble Amplitude | ≤0.5 mm |
| Basket Wobble Amplitude | ≤1.0 mm |
| Water Bath Temperature Range | Ambient to 45°C |
| Water Bath Temperature Resolution | 0.1°C |
| Water Bath Volume | 18 L |
| Brand | LOGAN |
|---|---|
| Origin | USA |
| Model | UDT-818A-8 |
| Instrument Type | Online Dissolution Tester |
| Number of Vessels | 8 |
| Temperature Range | 20–60°C |
| Temperature Accuracy | ±0.1°C |
| Rotation Speed Range | 25–250 rpm (±1 rpm) |
| Paddle Wobble Amplitude | ≤0.5 mm |
| Basket Wobble Amplitude | ≤1.0 mm |
| Water Bath Temperature Range | Ambient to 45°C |
| Water Bath Temperature Resolution | 0.1°C |
| Water Bath Volume | 18 L |
| Brand | LoHand |
|---|---|
| Model | LH-B50 |
| Origin | Zhejiang, China |
| Instrument Type | Milk Cryoscope (Freezing Point Depression Analyzer) |
| Measurement Principle | Thermistor-based freezing point depression detection |
| Sample Volume | ~1.0–1.5 mL |
| Resolution | 0.001 °C |
| Repeatability | ±0.002 °C |
| Operating Temperature Range | 10–30 °C ambient |
| Power Supply | Rechargeable lithium-ion battery (≥8 hrs continuous operation) |
| Compliance | Designed per ISO 5725 (accuracy verification), aligned with IDF Standard 192 (Milk Cryoscopy), and supports GLP data integrity requirements |
| Brand | Loobo |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | BG9711A |
| Price | Upon Request |
| Detector | Ø40×37 mm NaI(Tl) Scintillation Crystal |
| Measured Radionuclides | Cs-137, Cs-134 (calibration-compatible with I-125, Co-60, etc.) |
| Detection Limit | 20 Bq/L (relative to Cs-137) |
| Measurement Protocol | 30-min background + 10-min sample |
| Lead Shielding Thickness | 25 mm |
| Display | LCD showing activity or specific activity with uncertainty estimation |
| Background Subtraction | Enabled |
| LED Status Indicators | Green (safe), Yellow (elevated), Red (exceeds regulatory threshold) |
| Operating Temperature | 10–35 °C |
| Operating Humidity | ≤80% RH at 40 °C |
| Primary Power | DC 9 V / 1000 mA adapter |
| Backup Power | Two AA batteries |
| Power Consumption | <200 mW |
| Dimensions (L×W×H) | 190×190×350 mm |
| Net Weight | 26.4 kg |
| Data Storage | 200 measurement records |
| Connectivity | Optional USB interface for PC-based control and data export |
| Compliance | Designed for field-deployable radiological screening per IAEA Safety Guides RS-G-1.8 and national food/water monitoring protocols |
| Brand | Loobo |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | LB-QM6 |
| Detection Sensitivity | 1×10⁻¹⁵ mol ATP |
| RLU Range | 0–999,999 RLU |
| Background Noise | ≤2 RLU |
| Detection Limit | 1.0 CFU/mL |
| Assay Time | 10 s |
| Accuracy | ±5% or ±5 RLU |
| Overrange Protection | Tilt-activated interruption |
| Display | 3.5-inch color TFT LCD |
| Data Storage | 10,000 records |
| Connectivity | USB + Bluetooth v5.0 |
| Output Options | Optional Bluetooth thermal printer |
| Power Supply | Rechargeable Li-ion battery (AC travel charger included |
| Battery Life | >10 h |
| Operating Temperature | 5–40 °C |
| Operating Humidity | 20–80% RH |
| Dimensions | 70 × 35 × 190 mm |
| Weight | 300 g |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | LOPAP |
| Pricing | Available Upon Request |
| Brand | Quantum Design |
|---|---|
| Origin | Germany |
| Manufacturer | LOT-Oriel Group (a Quantum Design Company) |
| Type | LOT Series |
| Illumination Mode | Steady-State |
| Light Source | 300 W Short-Arc Xenon Lamp (Ozone-Free) |
| Spectral Match Class | ASTM E927 Class B |
| Irradiance Instability | ≤1% RMS (typ.) |
| Output | Fiber-Coupled |
| Optional Filters | AM1.5G or AM0 |
| Optional Shutter | Digital or Manual Mechanical/Electronic |
| Optional Add-on | VSM-FOSH Photomagnetic Measurement Kit with Monochromatic Light Source (MLS), 360–845 nm, 150 W Xenon Lamp, UV-Vis-NIR Fiber Delivery (D320-UV: 325–900 nm |
| D320-IR | 375–2250 nm), Max Sample Diameter: 1.6 mm, Magnetic Sensitivity: <1×10⁻⁴ emu |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | PFXi880 |
| Spectral Range | 420–710 nm |
| Spectral Bandwidth | 10 nm |
| Repeatability | ±0.0002 in CIE x,y chromaticity coordinates |
| Measurement Time | <30 s |
| Optical Path Length | 0.1–153 mm |
| Light Source | 5 V, 10 W tungsten-halogen lamp |
| CIE Illuminants | A, B, C, D65 |
| Standard Observer Angles | 2°, 10° |
| Data Storage Capacity | 100,000 measurements |
| Interfaces | USB, LAN, RS232 |
| Display | 240 × 128 backlit LCD |
| Power Supply | 90–240 V AC (external adapter) |
| Housing | Steel with textured epoxy coating |
| Dimensions & Weight | 515 × 195 × 170 mm / 7.7 kg |
| Compliance | CE, RoHS, WEEE |
| Optional Heater | Up to 95 °C |
| Language Support | English, Chinese, French, German, Italian, Portuguese, Russian, Spanish, Japanese |
| Software Features | GLP-compliant reporting, operator ID, sample ID, timestamp, RCMSi remote calibration and maintenance system |
| Built-in Color Scales | Lovibond RYBN, ASTM D1500, IP 17, ICUMSA, AOCS, Saybolt, CIE XYZ/xyY, spectral reflectance data |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Laboratory Instrument |
| Model | LPC500 + Avio500 |
| Application | Elemental Analysis & Particle Counting in Lubricants |
| Sample Volume | <1 mL per dual analysis |
| Cycle Time | ≤45 seconds per sample |