| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DL-1 |
| Detection Principle | Coulometric Titration (per GB/T 214–2007) |
| Furnace Max Temp | 1500 °C (continuous operation at 1200 °C) |
| Heating Rate | 20–25 °C/min |
| Isothermal Zone | 80 mm (±10 °C) |
| Furnace Tube | Dual-threaded silicon carbide tube (Φ70/60 × 250/100 × 30 mm) |
| Reaction Tube | Alumina tapered tube (Φ22/18 × 760 mm) |
| Temperature Control Range | 0–1600 °C |
| Power Consumption | ~4 kW |
| Supply | 220 V, 50 Hz |
| Thermocouple | Pt-Rh/Pt (Class I accuracy, 0–1600 °C) |
| Net Weight | ~80 kg |
| Dimensions (L×W×H) | Furnace unit: 760×300×410 mm |
| Absorption unit | 340×150×320 mm |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | FC-6 |
| Voltage | 220 V AC, 50 Hz |
| Current Rating | 1.5 A |
| Power Consumption | 180 W |
| Drum Material | Stainless Steel (AISI 304) |
| Drum Inner Diameter | 220 mm |
| Maximum Sample Mass | < 2 kg |
| Net Weight | 40 kg |
| Drive System | V-belt transmission with step-start pulley |
| Safety Compliance | Grounded chassis, interlocked lid switch (mechanical), centrifugal brake stop |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Model | FCL-1 |
| Temperature Control Accuracy | ±5°C at 1100°C |
| Temperature Range | Ambient to 1300°C |
| Heating Time | ≤25 min to 1100°C |
| Method | High-Temperature Combustion Hydrolysis |
| Fluorine Analysis Compliance | GB/T 4633–2014 |
| Chlorine Analysis Compliance | GB/T 3558–2014 |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Max. Power Consumption | ≤3.5 kW |
| Stirring Speed | Continuously Adjustable with Digital Display |
| Flowmeter Range | 0–1000 mL/min (graduation: 10 mL/min) |
| High-Temperature Furnace | Capable of ≥1100°C with ≥80 mm uniform zone at 1100±5°C |
| Combustion Tube | Fused Quartz, Rated ≥1200°C |
| Voltage Control for Evaporation | Solid-State Relay, 0–220 V Continuous Adjustment |
| Temperature Controller | PID-Based with Low-Drift Components |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | Float-Sink Test Scoop |
| Price | USD 7.20 (ex-works) |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Model | GF-3000 |
| Power Supply | 220 V, 50 Hz, 6 kW (main unit) |
| Gas Requirements | O₂ purity ≥99.5%, regulated pressure 0.25 MPa |
| Operating Temperature | 10–40 °C |
| Relative Humidity | 35–85% RH |
| Atmospheric Pressure | 86–106 kPa |
| Sample Mass | 0.9000–1.1000 g |
| Furnace Temperature Range | Ambient to 1000 °C |
| Capacity | Up to 19 samples per run |
| Dimensions | 655 × 600 × 575 mm (L×W×H) |
| Weight | 60 kg |
| Compliance | GB/T 212–2001 |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | GF-6000 |
| Furnace Configuration | Dual independent furnaces (A-furnace for moisture/ash/volatiles |
| Sample Capacity | 19 samples per run |
| Temperature Range | Ambient to 1000 °C |
| Test Temperatures | Moisture at 105 °C, Ash at 815 °C, Volatiles at 900 °C |
| Sample Mass | Moisture/Ash: 0.6–1.1 g |
| Volatiles | 0.9–1.1 g |
| Compliance | Fully conforms to GB/T 212–2008 “Methods for Proximate Analysis of Coal” |
| Gas Requirements | N₂ and O₂, both ≥99.5% purity, regulated to 0.1 MPa |
| Power Supply | AC 220 V, 50 Hz |
| Power Consumption | A-furnace: 5 kW |
| B-furnace | 2 kW |
| Net Weight | A-furnace ≈ 95 kg |
| Crucible Capacity | 20 positions (19 active test stations) |
| Integrated Analytical Balance | Modular high-stability microbalance with automated tare and sample loading |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | GZ Series |
| Price Range | USD 37 – 315 |
| Voltage Compatibility | AC/DC Configurable |
| Construction | Wound-Type Solenoid with Insulated Bobbin, Enamel-Coated Copper Wire, and Interleaved Insulation Paper |
| Operating Voltage Tolerance | 85–110% of Rated Voltage |
| Core Actuation Principle | Electromagnetic Attraction with Spring-Return Release |
| Structural Variants | Open-Type & Enclosed-Type Mounting Configurations |
| Custom Fabrication | Available per OEM Drawings and Technical Specifications |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Model | HDL-600H |
| Measurement Principle | Coulometric Titration |
| Sulfur Range | 0.01–40% |
| Resolution | 0.001% |
| Analysis Time | 4–8 min (sample-dependent) |
| Combustion Temperature | 1150 °C (coal), 920 °C (heavy oil) |
| Temperature Control Accuracy | ±3 °C |
| Sample Mass | 50 mg ±5 mg (coal), 80–100 mg (heavy oil) |
| Sample Capacity | 1–24 positions per run |
| Compliance | GB/T 214–1996 |
| Power Supply | 220 V ±10%, 50 Hz |
| Max. Power Consumption | ≤3.5 kW |
| Dimensions (W×D×H) | 1100 × 540 × 450 mm |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Model | HDL-600S |
| Measurement Principle | Coulometric Titration |
| Sample Capacity | 1–24 samples (batch + on-the-fly addition) |
| Sulfur Detection Range | 0.1–40% |
| Resolution | 0.001% |
| Temperature Control | 1150 °C (coal), 920 °C (oil) |
| Temperature Stability | ±3 °C |
| Sample Mass | 40–70 mg (coal), 50–100 mg (oil) |
| Test Duration | 4–8 min per sample |
| Power Supply | 220 V ±10%, 50 Hz |
| Max Power Consumption | ≤5 kW |
| Dimensions | 550 × 500 × 630 mm |
| Weight | 40 kg |
| Compliance | GB/T 214–2007, GB/T 214–1996 |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HDL-9 |
| Detection Principle | Coulometric Titration (ASTM D3177, GB/T 214, ISO 4299) |
| Application Scope | Coal, Coke, Iron Ore, Steel Slag, Limestone, Fly Ash, and Other Inorganic Solids |
| Compliance | GB/T 214–2007, ASTM D3177–22, ISO 4299:2021 |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HDL-9W |
| Detection Principle | Coulometric Titration (Microcoulometry) |
| Portability | Benchtop (Non-portable) |
| Analyte | Total Sulfur |
| Measurement Range | 0.1–40 wt% |
| Analysis Time | 3–9 min per sample |
| Detection Limit | 0.01 wt% (as specified in GB/T 214) |
| Display Interface | Dual-mode (Chinese LCD + PC-controlled) |
| Operating Temperature Range | 600–1150 °C (user-selectable |
| Carrier Gas Flow Rate | 1000 mL/min |
| Heating Element | Silicon Carbide Tube (340 mm length) |
| Power Supply | 220 V AC, 50 Hz, 2 kW |
| Compliance | GB/T 214–2007 |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Model | HKP-650 |
| Wavelength | Fixed at 650 nm |
| Wavelength Accuracy | ±0.1 nm |
| Wavelength Repeatability | 0.05 nm |
| Spectral Bandwidth | 1.7 nm |
| Absorbance Range | –0.4 to 4.0 A |
| Concentration Display Range | 0–99999 (unitless or customizable units) |
| Stray Light | ≤0.05% T |
| Baseline Flatness | ±0.002 A |
| Drift Stability | ±0.0007 A/h |
| Display | 7-inch color TFT touchscreen (Chinese UI) |
| Sample Chamber | Large-volume cuvette compartment |
| Output Interfaces | USB, RS-232 |
| Compliance | Designed per GB/T 216–2003 for phosphorus determination in coal |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Model | HM-60 |
| Motor Power | 90 W |
| Main Shaft Speed | 20 ± 1 rpm |
| Total Rotations | 60 ± 0.25 rev |
| Applied Load | 284 ± 2 N |
| Voltage Options | 220 V or 380 V (default 380 V) |
| Net Weight | 90 kg |
| Dimensions (L×W×H) | 440 × 380 × 500 mm |
| Compliance | GB/T 2565–2014 (revised version of GB 2565–87) |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Model | HR-3 |
| Furnace Type | Horizontal High-Temperature Furnace |
| Heating Element | Silicon Carbide (SiC) Tube |
| Max Temp | 1600 °C |
| Temp Resolution | 1 °C |
| Temp Accuracy | ≤0.2% FS |
| Thermocouple | Pt-Rh/Pt (Type S) |
| Controlled Ramp Rates | 15–20 °C/min up to 900 °C |
| Imaging System | CCD Camera with Real-Time Digital Capture |
| Image Storage Interval | 1 min ≥900 °C |
| Compliance | GB/T 219–2008 |
| Communication Interface | RS-232 (with optional USB adapter) |
| Software Platform | Windows XP or later |
| Dimensions (L×W×H) | 900×380×470 mm |
| Weight | 45 kg |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Model | HR-4 |
| Temperature Range | Ambient–1600 °C (resolution: 1 °C, S-type thermocouple) |
| Heating Rate | 15–20 °C/min up to 900 °C |
| Temperature Accuracy | ±3 °C |
| Timing Range | 0–999 min (1 s resolution <10 min) |
| Timing Drift | <1 s/h |
| Max Output Current | ≤30 A |
| Power Supply | AC 220 V, 50 Hz |
| Operating Environment | 0–40 °C, RH ≤80% |
| Control Core | Microcontroller-based closed-loop phase-angle SCR control with auto-calibration of temperature and current |
| Compliance | Designed per GB/T 219–2008 (Chinese National Standard for Coal Ash Fusibility Determination) |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HX-2 |
| Price | USD 2,250 (approx.) |
| Furnace Max Temp | 1500 °C |
| Operating Temp Range | 1200–1300 °C |
| Heating Rate | 20–25 °C/min |
| Hot Zone Length | 100 mm |
| Silicon Carbide Tube | Dual-threaded, Φ45/35 × 500/100 mm, 40 mm active length |
| Reaction Tube | Alumina, Φ25/20 × 850 mm |
| Temperature Sensor | Pt–Rh/Pt thermocouple, 0–1600 °C, Class 1.0 accuracy |
| Power Consumption | 4–5 kW |
| Supply Voltage | 220 V ±10%, 50 Hz |
| Net Weight | 90 kg |
| Dimensions (Furnace) | 400 × 460 × 980 mm |
| Gas Analyzer Range | 0–99% CO₂, Accuracy: ±2% FS |
| Gas System | CO₂ purification train (pressure regulator, scrubbers, desiccant tower, flowmeter), buoyancy-type gas collection cylinder (Φ360 × 750 mm) |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | JB-2 |
| Pricing | USD 92 (based on ¥650 @ 7.07 exchange rate) |
| Technology | Coulometric Titration |
| Air Flow Rate | 1000 mL/min |
| Power Supply | 220 VAC |
| Dimensions (L×W×H) | 240 × 180 × 295 mm |
| Core Components | Electromagnetic Pump, Glass Rotameter with Needle Valve, Dual-Stage Drying Tube (Silica Gel + Acid Scavenger) |
| Key | Brand: MingShen Science |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | JCM-2 |
| Power | 120 W |
| Voltage/Frequency | 220 V / 50 Hz |
| Motor Speed | 1400 rpm |
| Dimensions (L×W×H) | 360 mm × 240 mm × 300 mm |
| Weight | 19 kg |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | JX-2 |
| Price | USD 2,700 (approx.) |
| Compliance | GB/T 1572–1989 |
| Sample Size | 400 cm³ |
| Particle Size Range | 3–6 mm |
| Required Air Blower | ≥12 m³/h airflow, ≥1000 mmHg pressure |
| Sieve Aperture | 6 mm |
| Slag Retention Measurement | Mass fraction (%) of residue >6 mm after vibratory sieving |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | KZDL-8H |
| Pricing | USD 1,350 (FOB) |
| Measurement Principle | Coulometric Titration (ASTM D3177, GB/T 214, ISO 4299) |
| Sulfur Range | 0.1–40 wt% |
| Combustion Time | 3–9 min per sample |
| Furnace Temp Control | 1150 ± 5 °C (adjustable, SiC heating element, hot zone ≥90 mm) |
| Temperature Sensor Accuracy | Class 0.5 |
| Heating Rate | 25–30 °C/min (reaches 1200 °C in ~35 min) |
| Electrolytic Cell Volume | 450 mL (organic glass construction with sintered glass frit gas diffuser) |
| Stability | Stable operation within 60 seconds after power-on |
| Power Supply | 220 V ± 20 V AC, 50 Hz |
| Dimensions (mm) | Controller: 365 × 155 × 340 |
| High-Temp Furnace | 580 × 250 × 270 |
| Air Purifier Unit | 258 × 300 × 360 |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | KZDL-9C |
| Measurement Principle | Combustion-Iodometric Titration (Dry Colorimetric Method per GB/T 2462–1996) |
| Power Supply | 220 V ±20 V, 50 Hz |
| Max. Power Consumption | ≤2.5 kW |
| Sulfur Range | 0.01–99.99 wt% |
| Resolution | 0.01 wt% |
| Temperature Control Range | 300–1300 °C |
| Temp. Display Range | Ambient to 1300 °C |
| Temp. Resolution | 1 °C |
| Target Temp. Setpoint Accuracy | ±5 °C at 1150 °C |
| Heating Time | ~25 min to reach 1150 ±5 °C |
| Sample Positioning | Dual-Hall Element Driven Multi-Stage Auto-Sampling |
| Furnace Design | Horizontal High-Temperature Tube Furnace |
| Dimensions (L×W×H, mm) | Controller: 370×350×170 |
| Furnace | 580×250×270 |
| Purifier | 180×245×300 |
| Net Weight | Controller 5 kg, Furnace 15 kg, Purifier 4 kg |
| Compliance | GB/T 2462–1996, ASTM D4294 (referenced methodology), ISO 8754 (equivalent combustion principle) |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LM |
| Price | USD 92 (FOB) |
| Input Voltage Range | ±15% of 220 VAC |
| Control Signals | 4–20 mA, 0–5 VDC |
| Output Trigger Type | Single-Phase Phase-Angle Control |
| Isolation | Optocoupled Input/Output |
| Operating Temperature | –20 °C to +40 °C |
| Relative Humidity | ≤85% RH at 25 °C |
| Conducted Current | 50 mA |
| On-State Voltage Drop | <1.5 V |
| Off-State Leakage Current | <10 mA |
| Turn-On Time (50 Hz) | 1 ms |
| Turn-Off Time | 10 ms |
| Dimensions (L×W×H) | 210 × 135 × 270 mm |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MDH |
| Capacity Options | 500 mL and 1000 mL |
| Dimensions (500 mL) | Height 205 mm, Base Diameter 120 mm, Mass 210 g |
| Dimensions (1000 mL) | Height 250 mm, Base Diameter 145 mm, Mass 300 g |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | MFQ |
| Price Range | USD 120 – 350 |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MK-8 |
| Drum Internal Diameter × Length | 1000 mm × 1000 mm ±5 mm |
| Rotational Speed | 25 rpm (100 revolutions in 4 min ±10 s) |
| Motor Power | 2.2 kW |
| Net Weight | 970 kg |
| Overall Dimensions (L×W×H) | 1830 mm × 1350 mm × 1800 mm |
| Voltage | 380 V / 220 V AC |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Model | MLR-8W |
| Temperature Measurement Range | 0–65 °C |
| Temperature Resolution | 0.0001 °C |
| Sample Mass | 0.5–1.5 g |
| Heat Capacity | ~10,500 J/K |
| Outer Water Jacket Volume | ~51 L |
| Inner Water Bucket Volume | ~2.1 L |
| Ignition Voltage | 20 V |
| Ignition Duration | Programmable (3–8 s) |
| Water Quantification Accuracy | ≤ ±1 g |
| Ambient Operating Conditions | 5–40 °C, ≤30% RH (max ΔT ≤1 °C per test) |
| Power Supply | AC 220 V |
| Dimensions | 450 × 580 × 480 mm |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MRD-6M |
| Power | 800 W |
| Temperature Range | Ambient to 500 °C |
| Resolution | 1 °C |
| Repeatability Error | ≤5 °C |
| Heating Rate | 4.5–5.0 °C/min |
| Sample Capacity | 6 samples per run |
| Operating Environment | 5–40 °C, RH ≤80% |
| Supply Voltage | 220 V ±10%, 50 Hz |
| Dimensions (H×W×D) | 350 mm × 370 mm × 240 mm |
| Weight | 15 kg |
| Compliance | GB/T 18511–2001 |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Model | MSCQY-3000 |
| Measurement Principle | Coulometric-Gravimetric Method |
| H Range | 0–20 wt% |
| C Range | 1–99 wt% |
| Sample Mass | 70–75 mg (air-dried, <0.2 mm) |
| Analysis Time | ~10–15 min (including isothermal holds at 300°C for 30 s, 500°C for 2 min, and 850°C for ~10 min) |
| Electrolysis Voltage | Coating: 10 V |
| Operational | 24 V |
| Electrolysis Current | >600 mA (initial), <70 mA (endpoint) |
| Accuracy | Complies with GB/T 15460–2003 (H: ±0.15 wt%, C: ±0.50 wt%) |
| Heating Rate | ~50 min to 850°C |
| Linearity & Stability | ±0.1% full scale |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Model | MSCQY-5000 |
| Measurement Principle | Coulometric–Gravimetric Method |
| Carbon Range | 1–99 wt% |
| Hydrogen Range | 1–20 wt% |
| Furnace Temp. | 850 °C ±10 °C (combustion), 400 °C ±10 °C (reduction) |
| Electrolysis Voltage | 24 V (main), 10 V (coating film) |
| Electrolysis Current | >500 mA (working), <70 mA (endpoint) |
| Test Duration | 9–13.5 min |
| Linearity of Coulometric Integrator | ±0.1% |
| Max. Permissible Error | H ≤0.15 wt%, C ≤0.50 wt% |
| Sample Particle Size | <0.2 mm |
| Heating Rate | 25–30 °C/min |
| Power Supply | 220 V ±10%, 50 Hz, 3 kW |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Model | MTP-6 |
| Power Supply | AC 220 V ±20 V, 50 Hz |
| Power Consumption | ≤25 W |
| Balance Interface | RS-232 serial communication (supports continuous output mode) |
| Data Storage | 200-entry circular buffer (per parameter: moisture, ash, volatile matter, fixed carbon, G-index) |
| Print Function | Single-entry, page-wide, and historical report printing |
| Operating Modes | Error-prevention mode & continuous operation mode (switchable) |
| Compliance Support | ASTM D3172, ASTM D3173, ASTM D3174, ASTM D3175, ISO 1171, ISO 562, ISO 687, GB/T 212–2008 |