| Brand | HORIBA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Evaluator EC/ES Series |
| Pricing | Upon Request |
| Brand | HORIBA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Import Status | Imported |
| Model | EOL |
| Pricing | Upon Request |
| Brand | HORIBA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Evaluator LT Series |
| Price Range | USD 135,000 – 270,000 |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Custom-configurable XRF-based In-line Monitor |
| Pricing | Available upon consultation |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | SLFA-60 |
| Detection Target | Total Sulfur |
| Measurement Principle | X-ray Fluorescence (XRF) Spectrometry |
| Detection Range | 0–10 wt% S |
| Detection Limit | 5 ppm |
| Precision | ±5 ppm (at 1.0% S), ±1.6 ppm (at 0% S) |
| Sample Volume | 4–10 mL per analysis |
| Measurement Time | Adjustable from 10 to 600 seconds |
| Sample Capacity | 8-position automated rotary stage |
| Sample Holder | Disposable liquid-specific film-bottom cup |
| Calibration Flexibility | Up to 20 calibration points across 5 stored curves (linear/nonlinear) |
| Environmental Operating Range | 5–35 °C, 30–85% RH |
| Power Supply | AC 100–240 V ±10%, 50/60 Hz |
| Power Consumption | 150 VA |
| Interface | RS-232C standard serial port |
| Dimensions | 430 × 500 × 230 mm |
| Weight | ~24 kg |
| Compliance | ASTM D4294, ISO 8754, JIS K2541 & B7995, GB/T 17040–1997, GB/T 17060–1998, SN/T 0509–1995 |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | HSA |
| Pricing | Available Upon Request |
| Max Heating Temperature | 230 °C ±0.3% |
| Bidirectional Measurement | MD & CD |
| Thermal Expansion Range | up to 27% |
| Thermal Shrinkage Range | up to 5% |
| Sample Dimensions | 60 mm × 200 mm (MD or CD) |
| Resolution | 0.013% |
| Power Supply | 220 V / 50 Hz |
| Dimensions (H×W×D) | 295 mm × 280 mm × 320 mm |
| Weight | 15 kg |
| Brand | Hongtuo |
|---|---|
| Model | HT-1633-BA-4 |
| Temperature Range | Ambient to 300 °C |
| Heating Rate Options | (120 ±10) °C/h, (12 ±1) °C/6 min, (50 ±5) °C/h, (5 ±0.5) °C/6 min |
| Temperature Accuracy | ±0.5 °C |
| Temperature Resolution | 0.1 °C |
| Deflection Measurement Range | 0–10 mm |
| Deflection Resolution | ±0.001 mm |
| Specimen Stations | 4 independent test positions |
| Standard Span | 64 mm or 100 mm (per ISO 75 & ASTM D 648) |
| Load Bar + Platter Mass | 68 g |
| Heating Medium | Methyl Silicone Oil |
| Cooling Method | Integrated Forced-Air or External Water Cooling |
| Heating Power | 1.5 kW |
| Oil Bath Capacity | ~13 L |
| Dimensions (L×W×H) | 650 × 460 × 840 mm |
| Brand | hte |
|---|---|
| Origin | Germany |
| Product Type | Lab-scale High-Throughput Sintering Reactor |
| Configuration | 4×36 or 2×25 Independent Sample Channels |
| Crucible Capacity | Customizable (e.g., 36 × 10 g) |
| Max Operating Temperature | 1050 °C |
| Atmosphere Control | Oxidizing (O₂), Reducing (e.g., Syngas), Inert (N₂/Ar) |
| Temperature Gradient Resolution | ±0.5 °C per Zone |
| Heating/Cooling Rate Control | Programmable (0.1–20 °C/min) |
| Gas Flow Precision | ±1% FS Mass Flow Control |
| Data Acquisition | Real-time T, P, gas composition, dwell time, ramp profiles |
| Compliance | GLP-ready architecture, FDA 21 CFR Part 11–compatible audit trail (via hteControl v5.2) |
| Brand | HTE |
|---|---|
| Origin | Germany |
| Type | High-Throughput Co-Precipitation Reactor System for Battery Cathode Precursor Synthesis |
| Reactor Volume | 2 L or 10 L (customizable) |
| Operation Modes | Continuous, Batch with Concentrator, Heavy-Duty Batch with Concentrator |
| Max Operating Temperature | 70 °C at Ambient Pressure |
| Feed Types | Aqueous Metal Salt Solutions, Precipitants, Dopants, Dry Powders |
| Integrated Sensors | Real-time pH Monitoring, In-line Particle Size Measurement (e.g., laser diffraction), Automated Liquid Sampling |
| Software Suite | hteControl (experiment automation & data acquisition), Custom GUI, GLP-compliant audit trail |
| Compliance | Designed for ISO/IEC 17025-aligned R&D environments |
| Safety | Lab-in-Lab containment architecture with redundant safety sensors, 24/7 unattended operation certified |
| Material Output per Run | 1–5 kg of precursor (e.g., NMC, LFP, Prussian Blue analogues) |
| Scalability | Process parameters validated from lab-scale to pilot-scale with <±5% deviation in PSD and stoichiometry |
| Brand | Huicheng Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HC3500 |
| Price | USD 3,650 (FOB Jiangsu) |
| Temperature Range | Ambient to 1000 °C |
| Display | 7-inch TFT LCD Touchscreen |
| Sample Capacity | 4 parallel positions |
| Heating Zone Length | 260 mm |
| Furnace Tube Dimensions | Ø45 mm × 600 mm |
| Chamber Dimensions | Ø45 mm × 350 mm |
| Heating Element | High-Temperature Alloy Resistance Wire |
| Temperature Control | PID with Multi-Stage Programmable Ramp/Soak Profiles |
| Temperature Uniformity | ±5 °C across working zone |
| Sensor Resolution | 0.1 °C |
| Gas Control | Dual Mass Flow-Controlled Inlets (N₂ only), Auto-Switching per Program Step |
| Cooling Method | Lid-Open Forced-Air Rapid Cool-down |
| Power Supply | AC 220 V / 50 Hz, 600 W |
| Overall Dimensions | 416 × 325 × 289 mm |
| Compliance | GB/T 3515–2005, GB/T 13021–1991, GB/T 2951.41–2008, ISO 6964:2015, IEC 60811-4-1:2012, ASTM D1606 (referenced), JTG E50 T1165–2006 |
| Brand | Huiron |
|---|---|
| Model | HRH-BRM-2100 |
| Origin | Beijing, China |
| Tidal Volume Range | 0–1000 mL |
| Accuracy | ±5% of full scale or ±1 mL (whichever is greater) |
| Power Supply | 220 V, 50 Hz |
| Dimensions | 70 × 35 × 62 cm |
| Weight | 35 kg |
| Compliance | USP <601>, Ph. Eur. 2.9.43, ChP 2020 Vol. IV <0951> |
| Predefined Breathing Profiles | Adult / Pediatric / Infant / Neonatal |
| Customizable Parameters | Tidal Volume, Breathing Frequency, I:E Ratio, Flow Profile Shape, Cycle Count |
| Real-time Output | Flow Rate Curve, Tidal Volume Curve, Respiratory Parameter Summary |
| Brand | Spectra Invent |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HX-VIS1000 |
| Compliance Standard | GB/T 265 |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤85% |
| Dimensions (W×D×H) | 545 × 370 × 500 mm |
| Weight | 18.4 kg |
| Brand | SDL Atlas |
|---|---|
| Origin | Shenzhen, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | SDL Atlas |
| Pricing | Available Upon Request |
| Brand | aboni |
|---|---|
| Origin | Germany |
| Model | HT3 |
| Measurement Principle | Calcium Hydride Reaction (Direct Absolute Moisture Quantification) |
| Resolution | 0.01 mg / 1 ppm / 0.0001 % H₂O |
| Sample Type Compatibility | Plastic pellets, granules, powders, and molded polymer components |
| Interface | USB-connected to Windows PC |
| Output | Auto-generated PDF report with timestamp, sample ID, moisture content, and operator metadata |
| Calibration | Calibration-free across polymer types |
| Vacuum Requirement | None |
| Brand | IDM |
|---|---|
| Origin | New Zealand |
| Model | C0038 |
| Measurement Range | 0–1000 gf |
| Resolution | 0.5 g |
| Bending Angle | 90° (crease recovery), 15° (board stiffness) |
| Specimen Dimensions | Crease test: 38 × 36 mm |
| Board stiffness test | 70 × 38 mm |
| Test Duration | 15 s |
| Calibration Weight Included | 200 g |
| Interface | RS232 |
| Compliance Standards | BS 6965, BS 3748, ISO 2493:1992 |
| Power Supply | 220/240 VAC @ 50 Hz or 110 VAC @ 60 Hz |
| Dimensions (H×W×D) | 140 × 275 × 150 mm |
| Weight | 5.5 kg |
| Brand | IDM |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | C0042 |
| Price | USD 7,000 (FOB) |
| Cutting Area | 100 cm² (100 mm × 100 mm) |
| Dimensions (H×W×D) | 247 mm × 400 mm × 410 mm |
| Weight | 30 kg |
| Compliant Standards | AS/NZS 1301.405s, TAPPI T410 om-23, SCAN P6:75, CPPA D3 |
| Brand | IEST |
|---|---|
| Origin | Fujian, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | CAAS1200G/M |
| Pricing | Upon Request |
| Brand | illumion |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | illumionONE |
| Pricing | Upon Request |
| Detection Principle | Charge Photometry |
| Compatible Cell Format | Button Cells |
| Minimum Resolvable Particle Size | >350 nm |
| Field of View | 112 × 70 µm |
| Magnification | 100× |
| Illumination Wavelength | 530 nm |
| Image Acquisition Frame Rate | <100 Hz |
| Dimensions (W × D × H) | 40 × 50 × 31.5 cm |
| Electrochemical Integration | Fully Synchronized Potentiostat/Galvanostat Control |
| Brand | Huironghe |
|---|---|
| Model | HRH-20 |
| Origin | Beijing, China |
| Type | In Vitro–In Vivo Correlation (IVIVC) Simulation System for Orally Inhaled Products (OIPs) |
| Airflow Range | 0–100 L/min |
| Peak Inspiratory Flow Rate Simulation | 0–100 L/min |
| Flow Acceleration Rate | 0–15 L/s² |
| Respiratory Waveform Customization | Yes |
| Compliance Reference | Good Cascade Impactor Practices (GCIP), AIM & EDA Guidelines for Orally Inhaled Products (2013) |
| Intended Use | IVIVC development, aerodynamic particle size distribution (APSD) testing, delivered dose uniformity (DDU) assessment |
| Brand | In-situ High-tech |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | CIS-XRD-LB |
| Pricing | Available Upon Request |
| Cell Body Material | 316L Stainless Steel |
| Operating Temperature | Ambient (20–25 °C) |
| Operating Pressure | Atmospheric (101.3 kPa) |
| Maximum Sample Diameter | ≤16 mm |
| Maximum Separator Diameter | ≤20 mm |
| Detection Angular Range | 10° < 2θ < 100° |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Spectro Scientific |
| Type | Portable Mid-IR ATR Analyzer |
| Model | InfraCal 2 ATR-B |
| Detection Range | 0–100% biodiesel in diesel |
| Analysis Time | <30 s |
| Repeatability | ±0.2% (0–30%), ±1.0% (30–100%) |
| Compliant With | ASTM D7371, EN 14078 |
| Power | Rechargeable Li-ion battery (6+ hrs operation), 18 V DC input |
| Weight | 2.6 kg (net), 3.2 kg (with battery) |
| Dimensions | 17 × 19.8 × 13.2 cm |
| Operating Temperature | 5–40 °C |
| Wavelength | 5.7 µm (1745 cm⁻¹) |
| Interface | USB, RS-232 |
| Data Storage | Internal, password-protected, with operator/location/timestamp metadata |
| Display | Touchscreen LCD |
| Language Support | English, Spanish, French, Arabic |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | InfraCal 2 ATR-B |
| Measurement Principle | Attenuated Total Reflectance (ATR) Mid-Infrared Spectroscopy |
| Compliant Standards | ASTM D7371, EN 14078 |
| Detection Range | 0–100% biodiesel in diesel |
| Repeatability | ±0.2% (0–30%), ±1.0% (30–100%) |
| Analysis Time | <30 seconds |
| Power Supply | Rechargeable Li-ion battery (18 V DC, 3.3 A), >6 h operation |
| Weight | 2.6 kg (net), 3.2 kg (with battery) |
| Dimensions | 17 × 19.8 × 13.2 cm |
| Operating Temperature | 5–40 °C |
| Interface | Touchscreen display, USB, RS-232 |
| Data Storage | Internal memory with user, location, date/time stamping |
| Language Support | English, Spanish, French, Arabic |
| Calibration Options | Pre-loaded ATR-B curve (405-2041-24), optional multi-point calibration kits (e.g., 403-1024) |
| Brand | INNOTEG |
|---|---|
| Origin | Guangdong, China |
| Supplier Type | Authorized Distributor |
| Product Category | Domestic Reference Standards |
| Schedule Classification | UN/WHO Schedule I / China NMPA Category I Psychotropic Substances |
| Pricing | Available Upon Request |
| Brand | INNOTEG |
|---|---|
| Origin | Guangdong, China |
| Supplier Type | Authorized Distributor |
| Product Category | Domestic Standard Reference Materials |
| Schedule Classification | China NMPA Schedule II Psychotropic Substances |
| Pricing | Available Upon Request |
| Brand | INNOTEG |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | Controlled Substance Reference Standards |
| Pricing | Available Upon Request |
| Brand | INNOTEG |
|---|---|
| Origin | Guangdong, China |
| Supplier Type | Authorized Distributor |
| Product Category | Domestic Reference Standards |
| Model | High-Purity Controlled Substance Reference Standards |
| Pricing | Available Upon Request |
| Brand | INNOTEG |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Non-Medical Controlled Substance Reference Standards |
| Pricing | Available Upon Request |
| Brand | INNOTEG |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | INNOTEG Syringe Filters |
| Pricing | Available Upon Request |
| Membrane Materials | Nylon 66, Hydrophobic PTFE, Hydrophilic PTFE, Polyethersulfone (PES), Polyvinylidene Fluoride (PVDF), Mixed Cellulose Ester (MCE) |
| Pore Sizes | 0.22 µm and 0.45 µm |
| Diameters | 13 mm and 25 mm |
| Connector Type | Luer Lock / Luer Slip Compatible |
| Packaging | 100 units per canister |
| Brand | INNUO |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (China) |
| Model | DH-G1001B |
| Price Range | USD 9,800 – 13,900 |
| Temperature Range | Ambient to 999.9°C |
| Heating Zone Length | 300 mm |
| Combustion Tube Dimensions | Ø32 mm × 450 mm |
| Heating Element | Resistance Wire |
| Display | 7-inch Capacitive Touchscreen |
| Gas Flow Control | Dual-channel Float-type Flowmeter (Optional Mass Flow Controller) |
| Flow Ranges | 3 L/min (0.1 L/min resolution, for wire & cable) or 250 mL/min (12.5 mL/min resolution, for pipe & fitting) |
| Temperature Control | PID Programmable Controller with Auto-segment Memory |
| Crucible Options | (1) Wire/Cable: 93 mm total length (70 × 16 × 11 mm cavity) |
| (2) Pipe/Fitting | 72 mm total length (55 × 7 × 9 mm cavity) |
| Calculation Engine | Automatic black content, ash content, and filler content computation from user-input mass values |
| Data Output | Integrated thermal printer |
| Power Supply | AC 220 V, 50/60 Hz |
| Rated Power | 1.5 kW |
| Dimensions (W × D × H) | 30 × 49 × 50 cm |
| Thermal Insulation | Nano-fiber Blanket for Uniform Furnace Temperature Distribution |
| Compliance | GB/T 13021–2023 (ISO 6964), GB/T 2951.41–2008 (IEC 60811-4-1), JB/T 4278.17–2011, JTG E50–2006 (T1165) |
| Brand | INNUO |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (China) |
| Model | DH900B |
| Pricing | Available Upon Request |