Industry-specific Instruments
Filter
Showing 841–870 of 6193 results
| Brand | SDLATLAS |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | D395 |
| Pricing | Upon Request |
| Key | Brand: PULUODY |
|---|---|
| Model | PLD-0232A |
| Temperature Control Range | 40 °C |
| Temperature Accuracy | ±0.5 °C |
| Timing Range | 0–100 min (user-adjustable) |
| Power Supply | AC 220 V |
| Max. Power Consumption | 1200 W |
| Construction | Stainless Steel Bath & Lid |
| Compliance | SH/T 0232 |
| Brand | Vacuumatic |
|---|---|
| Origin | United Kingdom |
| Model | COUNT-S |
| Counting Principle | Non-contact optical stack height measurement |
| Max Stack Height | 450 mm |
| Interface | Color touchscreen display |
| Design | Modular, production-line integrable |
| Intended Use | High-volume sheet-based counting in secure document and pharmaceutical packaging environments |
| Compliance Context | Designed for GLP/GMP-aligned manufacturing workflows requiring audit-ready process traceability |
| Brand | Aerospace Zongheng |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CRTA-2 |
| Price Range | USD 1,400 – 2,800 |
| Airflow Configuration | Axial Fan with Conical Inlet Duct |
| Wind Speed Control | 3.0 ± 0.3 m/s |
| Operating Voltage | 200–240 V, 50 Hz |
| Environmental Test Conditions | 23 ± 2 °C, 50 ± 5 % RH |
| Compliant Standards | GB 9779–2015, JG/T 24–2000 |
| Origin | Italy |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Cryosmart 1 |
| Pricing | Available Upon Request |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | CRYSTEX |
| Pricing | Available Upon Request |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Detection Principle | Non-Dispersive Infrared (NDIR) |
| Model | CS2000M |
| Measurement Range | C: 0–100%, S: 0–100% |
| Accuracy | ±1% of measured content |
| Analysis Time | 90 s (typical) |
| Sample Mass | 300–500 mg |
| Combustion Temperature | Ambient to 1400 °C |
| Oxygen Purity | >99.5%, Pressure: 40 PSI |
| Gas Flow Rate | 3.0 L/min |
| Reagent | Magnesium Perchlorate |
| Interface | 4 RS-232 ports for analytical balance integration |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CS325 |
| Pricing | Available Upon Request |
| Origin | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CSBox-HF |
| Detection Method | Non-Dispersive Infrared (NDIR) |
| Measurement Range | C: 0.001–4 wt% |
| S | 0.002–1 wt% (extendable to 100% via sample weight reduction) |
| Precision | ±1% relative (for majority of solid inorganic samples) |
| Analysis Time | 20–60 s (typical) |
| Sample Mass | 100–2000 mg |
| Combustion Temperature | 1300–1500 °C (HF induction furnace) |
| Power Supply | 180–240 V AC, 50/60 Hz |
| HF Furnace Rating | 3.5 kW |
| Dimensions (Furnace) | 200 × 90 × 360 mm (L×W×H) |
| Weight | 24 kg (total system) |
| Carrier Gas | Ultra-high-purity O₂ (≥99.5%), 1 bar, ~2 L per analysis |
| Pump | External diaphragm pump with Viton seals (Germany-sourced) |
| Origin | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | CSBox-Tube |
| Pricing | Upon Request |
| Key | Origin: France |
|---|---|
| Detection Principle | Non-Dispersive Infrared (NDIR) |
| Measurement Range | C: 0–100%, S: 0–100% |
| Accuracy | ±1% relative (typical samples) |
| Sample Mass | 10–200 mg |
| Analysis Time | 40–300 s |
| Combustion Temperature | 800–1550 °C |
| Carrier Gas | O₂ or ambient air (for inorganic matrices) |
| Power Supply | 230 V, 0.75–2 A |
| (Imported from | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CSBox-Tube-S |
| Detection Principle | Non-Dispersive Infrared (NDIR) |
| Measurement Range | 0.005–100% S |
| Accuracy | ±1% relative |
| Sample Weight | 10–200 mg |
| Analysis Time | 40–300 s |
| Combustion Temperature | 800–1550 °C |
| Gas Supply | O₂ or ambient air (for inorganic samples) |
| Dimensions (H×W×D) | 500 × 360 × 500 mm |
| Power Supply | 230 V, 0.75–2 A |
| Compliance | ASTM D4294, ISO 4319, ISO 10723, EN 15407, USP <281>) |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Detection Principle | Non-Dispersive Infrared (NDIR) |
| Model | CSBox-Tube-S |
| Measurement Range | 0.005–100 wt% S |
| Accuracy | ±1% relative (typical samples) |
| Sample Mass | 10–200 mg |
| Analysis Time | 40–300 s |
| Combustion Temperature | 800–1500 °C (configurable by mode) |
| Interface Protocol Support | Sartorius, Mettler, Precia, Ohaus (RS-232/USB), manual entry |
| Data Output | LPT, COM, USB, LAN (RJ45) |
| Operating System | FreeDOS on Advantech industrial motherboard |
| Brand | CSFriend |
|---|---|
| Origin | Hunan, China |
| Model | FDT-0234 |
| Flash Point Range | -30 °C to 50 °C |
| Temperature Control Accuracy | ±0.5 °C |
| Measurement Precision | < 2 °C |
| Sample Volume | 2 mL (liquid), 4 mL (solid/semi-solid) |
| Ignition Method | Electronic spark igniter |
| Cooling System | Peltier thermoelectric cooling with external chilled water circulation |
| Power Supply | AC 220 V ±10 %, 50 Hz |
| Max. Power Consumption | ≤300 W |
| Operating Ambient | 5–30 °C, 30–80 % RH |
| Compliance | GB/T 5208 (Rapid Equilibrium Closed-Cup Method) |
| Brand | CSY |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | CSY-ATP |
| Price Range | USD 1–999 (FOB) |
| Detection Principle | Luciferin–Luciferase Bioluminescent Reaction |
| Detection Unit | RLU (Relative Light Unit) |
| Sensitivity | 1 × 10⁻¹⁶ mol ATP |
| Dynamic Range | 1–9999 RLU (customizable up to 999999) |
| Measurement Time | ≤10 s per sample |
| Repeatability | ≤±5% CV |
| Sample Point Capacity | ≥2000 unique locations |
| Data Storage | ≥20,000 test records |
| Connectivity | USB 2.0, Bluetooth 4.2, Wi-Fi 802.11 b/g/n |
| Result Interpretation | Pre-programmed RLU-to-Cleanliness-Level mapping (e.g., Pass/Alert/Fail) with configurable thresholds |
| Brand | Shenfen Instruments (CSY) |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CSY- |
| Price Range | USD 420 – 1,920 |
| Brand | CSY Instruments |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CSY-10CDF |
| Function Type | Multi-analyte (10-channel) Spectrophotometric Analyzer |
| Sample Compatibility | Liquid extracts from tea leaves, tea beverages, instant tea powders, and herbal infusions |
| Wavelength | 410 nm ± 2 nm |
| Measurement Time per Sample | ≤ 3 min |
| Photometric Repeatability | ±1% (Transmittance) |
| Optical Path | 10 mm cuvette |
| Absorbance Range | 0.000–4.000 ABS |
| Wavelength Accuracy | < ±2.0 nm |
| Baseline Stability | ±0.001 A/hr |
| Data Storage Capacity | ≥ 8,000 records |
| Display | 7-inch color TFT LCD touchscreen |
| Connectivity | RS-232, USB, Wi-Fi, Ethernet |
| Power Supply | AC 100–240 V, 50/60 Hz or optional DC 12 V battery operation |
| Dimensions | 350 × 290 × 130 mm |
| Weight | 3.8 kg |
| Brand | CSY |
|---|---|
| Origin | Guangdong, China |
| Model | CSY-10EYHL |
| Detection Principle | Visible Spectrophotometry (410 nm ± 2 nm) |
| Detection Range | Not Specified (Instrument-Specific Calibration Required) |
| Detection Limit | Not Specified (Instrument-Specific Calibration Required) |
| Accuracy Error | ±3% |
| Linearity Error | ±0.5‰ |
| Stability | ±0.001 A/hr |
| Wavelength Accuracy | <2.0 nm |
| Absorbance Range | 0.000–4.000 ABS |
| Transmittance Repeatability | ±1% |
| Data Storage Capacity | 8,000 entries |
| Sample Measurement Time | ≤3 min |
| Cuvette Size | 10 × 10 mm |
| Dimensions | 350 × 290 × 130 mm |
| Display | 7-inch color TFT LCD touchscreen |
| Optical Source | High-stability imported LED |
| Channel Configurations | 5–30 customizable photometric channels |
| Connectivity | RS-232, USB, Wi-Fi, Ethernet |
| Integrated Thermal Printer | Yes (ribbon-free, lifetime operation) |
| Software Compatibility | CSY Food Safety Monitoring Network Platform (customizable multi-tier deployment) |
| Brand | CSY |
|---|---|
| Model | CSY-10JQ |
| Origin | Guangdong, China |
| Detection Principle | Visible Spectrophotometry (410 nm ± 2 nm) |
| Optical Path | 10 × 10 mm Cuvette |
| Absorbance Range | 0.000–4.000 ABS |
| Wavelength Accuracy | < 2.0 nm |
| Absorbance Stability | ±0.001 A/hr |
| Linearity Error | ±5 ‰ |
| Measurement Accuracy | ±3% |
| Transmittance Repeatability | ±1% |
| Sample Test Time | ≤ 3 min |
| Data Storage Capacity | ≥ 8,000 records |
| Display | 7-inch Color TFT LCD Touchscreen |
| Connectivity | RS-232, USB, Wi-Fi, Ethernet |
| Printer | Embedded Thermal Printer (ribbon-free, lifetime operation) |
| Channel Configurations | 5–30 customizable photometric channels |
| Power Supply | AC 220 V / DC 12 V portable option |
| Dimensions | 350 × 290 × 130 mm |
| Weight | ~3.2 kg |
| Brand | CSY (Shenzhen Finanalysis Instruments Co., Ltd.) |
|---|---|
| Origin | Shenzhen, China |
| Model | CSY-JAZ |
| Detection Principle | Reflectometric Photometric Scanning of Lateral Flow Immunoassay Strips |
| Optical Source | 450–475 nm LED |
| Detection Speed | 240 tests/hour |
| Repeatability | ≤1% CV (using certified control strips) |
| Inter-instrument Variability | ≤3% (using certified control strips) |
| Detection Mode | Semi-quantitative & quantitative |
| Display | 7-inch true-color capacitive touchscreen (customizable to 10-inch) |
| Strip Width Compatibility | 2–6 mm (customizable) |
| Detection Channels | Single-channel (dual-, 5-, or 10-channel configurations available upon request) |
| Data Interfaces | USB 2.0, RS-232 serial, 10/100M Ethernet |
| Wireless | Integrated Wi-Fi module |
| Power Supply | 12 V DC (vehicle-compatible |
| Data Storage | Embedded high-capacity database with categorized query functionality |
| Barcode/QR Support | Optional integrated barcode scanner or QR code reader (custom OEM/ODM) |
| Line Recognition | Auto-C/T line detection with ±3 mm positional error tolerance |
| Reporting | On-screen concentration display with unit (e.g., µg/kg), thermal printer output (built-in), raw scan curve archiving |
| Regulatory Alignment | Designed to support GLP-compliant workflows |
| Brand | CSY Instruments |
|---|---|
| Origin | Guangdong, China |
| Manufacturer | Shenzhen CSY Instrument Manufacturing Co., Ltd. |
| Model | CSY-L5 |
| Measurement Range | 0.01–100% H₂O |
| Readability | 0.01% |
| Weighing Capacity | 0–100 g |
| Weighing Sensor Resolution | 0.001 g |
| Heating Source | Halogen Lamp (Adjustable, 0–205 °C) |
| Dimensions | 310 × 200 × 200 mm |
| Sensor | HBM (Germany) Load Cell |
| Compliance | ASTM D6980, ISO 15512, GB/T 29246–2012 |
| Brand | CSY |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | CSY-L5A |
| Price Range | USD 1–1,400 (FOB) |
| Moisture Range | 0.01–100% |
| Readability | 0.01% |
| Weighing Capacity | 0–100 g |
| Sensor Resolution | 0.001 g |
| Weighing Technology | Electromagnetic Force Compensation Sensor |
| Heating Source | Halogen Tungsten-Quartz Annular Lamp |
| Temperature Range | Ambient to 205 °C |
| Display Parameters | % Moisture, Time (s), Temperature (°C), Weight (g) |
| Interface | RS232 (FDA/HACCP-compliant data export) |
| Power Supply | 220 V ±10% / 110 V ±10%, 50/60 Hz ±1 Hz |
| Pan Diameter | 110 mm |
| Brand | CSY |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CSY-L5A |
| Moisture Range | 0.01–100% |
| Readability | 0.01% |
| Weighing Capacity | 0–100 g |
| Sensor Accuracy | 0.001 g |
| Weighing Technology | Electromagnetic Force Compensation Sensor |
| Heating Source | Halogen Tungsten Ring Lamp |
| Heating Temperature Range | Ambient to 205 °C |
| Display Parameters | % Moisture, Time, Temperature, Weight |
| Pan Diameter | 110 mm |
| Interface | RS232 (FDA/HACCP-compliant data export) |
| Power Supply | 220 V ±10% / 110 V ±10%, 50/60 Hz |
| Brand | CSY |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | CSY-L5B |
| Price | USD 1,650 (FOB Guangdong) |
| Moisture Range | 0.001–100% |
| Readability | 0.01% |
| Weighing Capacity | 0–100 g |
| Sensor Resolution | 0.001 g |
| Weighing Technology | Electromagnetic Force Compensation Sensor |
| Heating Source | Halogen Tungsten Ring Lamp |
| Heating Temperature Range | Ambient to 205 °C |
| Display Parameters | % Moisture, Time, Temperature, Weight |
| Communication Interface | RS232 (FDA 21 CFR Part 11 & HACCP-compliant data export) |
| Power Supply | 220 V ±10% / 110 V ±10%, 50/60 Hz |
| Pan Diameter | 110 mm |
| Brand | CSY (Shenzhen Finysis Instrument Manufacturing Co., Ltd.) |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Domestic Production | Yes |
| Model | CSY-N24A |
| Function Type | Multi-analyte Rapid Detection System |
| Sample Compatibility | Broad-spectrum for fruits, vegetables, herbs, and fresh produce |
| Wavelength | 412 nm ± 2 nm |
| Optical Path | 10 mm standard cuvette |
| Absorbance Range | 0.000–4.000 ABS |
| Photometric Repeatability | ≤0.1% |
| Photometric Accuracy | ±1% transmittance |
| Inter-channel Variation | ≤0.2% |
| Stability | ±0.001 A/hr |
| Measurement Time per Sample | ≤3 minutes |
| Data Storage Capacity | >800,000 records |
| Display | 10.1″ capacitive touchscreen (1920×1200), Android OS |
| Connectivity | USB, RS-232, Wi-Fi, Bluetooth, MicroSD slot |
| Integrated Thermal Printer | Compliance certificate + QR/barcode hybrid printing |
| Cloud Integration | Compatible with national agricultural traceability platforms (e.g., China National Traceability Platform) |
| Regulatory Alignment | Designed to support GB/T 22292–2017 (Pesticide Residue Testing in Vegetables and Fruits), NY/T 448–2021 (Rapid Detection of Organophosphorus and Carbamate Pesticides), and GLP-aligned data audit trails |
| [Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | CTS-8005Aplus |
| Pricing | Available Upon Request |
| Operating Frequency | 0.5–15 MHz (dual-band wide/narrow mode) |
| Gain Range | 110 dB with step options of 0.1 / 1.0 / 2.0 / 6.0 dB |
| Detection Range | 0–5000 mm (steel longitudinal wave) |
| Pulse Shift | −20 to 3000 µs |
| Sound Velocity | 1000–9999 m/s |
| Pulse Repetition Frequency | 25–800 Hz (adjustable) |
| Vertical Linearity | ≤4% |
| Horizontal Linearity | ≤0.5% |
| Resolution | ≥28 dB |
| Sensitivity Margin | ≥60 dB (200 mm–φ2 mm flat-bottom hole) |
| Dynamic Range | ≥32 dB |
| Electrical Noise Level | ≤10% |
| Suppression | 0–80% (linear) |
| Detection Modes | Full-wave, Positive half-wave, Negative half-wave |
| Alarm Output | Audio + visual |
| Interface | High-speed USB 2.0, 25-pin parallel printer port |
| Display | 6.5″ TFT color LCD, 640×480 resolution, ambient-light-adaptive color scheme |
| Power Supply | AC 220 V charger + rechargeable lithium-ion battery (no memory effect, >6 h continuous operation) |
| Operating Temperature | −30°C to +50°C |
| Dimensions (L×W×H) | 250 × 186 × 59 mm |
| Weight | ~2.0 kg] |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Regional Origin | Domestic (China) |
| Model | CTST-I |
| Pricing | Available Upon Request |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3100P |
| Measurement Principle | NDIR (CO, CO₂, CH₄, C₂H₂, C₂H₄, CnHm), TCD (H₂), ECD (O₂) |
| Response Time | T90 < 15 s (NDIR channels) |
| Measurement Range | CO/CO₂/CH₄/H₂: (0–100) % vol |
| O₂ | (0–25) % vol |
| C₂H₂/C₂H₄/CnHm | (0–10) % vol (optional) |
| Calorific Value | displayed in kcal/m³ and MJ/m³ |
| Resolution | 0.01 % vol |
| Linearity Error | ±1 % FS (NDIR gases), ±2 % FS (O₂, H₂) |
| Repeatability | ≤1 % |
| Sample Flow Rate | 0.7–1.2 L/min |
| Inlet Pressure | 2–50 kPa |
| Dimensions (L×W×H) | 412 × 152 × 294 mm |
| Weight | 9 kg |
| Power | Rechargeable Li-ion battery, external 12.6 V charger |
| Display | LCD |
| Communication | RS-232 |
| Data Storage | Internal logging with query/delete functions |
| Self-Diagnostic Capability | Real-time sensor status monitoring |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Instrument Principle | NDIR (CO, CO₂, CH₄, C₂H₂, C₂H₄, CnHm), TCD (H₂), ECD (O₂) |
| Response Time | T₉₀ < 15 s (NDIR) |
| Measurement Ranges | CO/CO₂/CH₄/H₂: (0–100)%, O₂: (0–25)%, C₂H₂/C₂H₄/CnHm*: (0–10)% (optional) |
| Resolution | 0.01% |
| Repeatability | ≤1% FS |
| Linearity Error | ±1% FS (NDIR gases), ±2% FS (O₂, H₂) |
| Sample Flow Rate | 0.7–1.2 L/min |
| Inlet Pressure | 2–50 kPa |
| Dimensions (L×W×H) | 412 × 152 × 294 mm |
| Weight | 9 kg |
| Power | Rechargeable Li-ion battery, external 12.6 V charger |
| Communication | RS-232 |
| Thermal Value Units | kcal/m³ & MJ/m³ (switchable) |
| Self-Diagnostic Function | Yes |
| Sample Requirements | Dust-free, moisture-free, oil-free |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3100P |
| Measurement Principle | NDIR (CO, CO₂, CH₄, C₂H₂, C₂H₄, CnHm), TCD (H₂), ECD (O₂) |
| Response Time | T₉₀ < 15 s (NDIR channels) |
| Measurement Ranges | CO/CO₂/CH₄/H₂: (0–100)%, O₂: (0–25)%, C₂H₂/C₂H₄/CnHm*: (0–10)% (optional) |
| Resolution | 0.01% |
| Thermal Value Output | kcal/m³ and MJ/m³ (user-selectable) |
| Flow Rate | (0.7–1.2) L/min |
| Inlet Pressure | (2–50) kPa |
| Dimensions (L×W×H) | 412 × 152 × 294 mm |
| Weight | 9 kg |
| Power | Rechargeable Li-ion battery, external 12.6 V charger |
| Interface | RS-232 |
| Display | LCD |
| Auto-diagnostic capability | Yes |
| Sample Requirements | Dust-free, dry, oil-free gas |