Industry-specific Instruments
Filter
Showing 961–990 of 2171 results
| Brand | INNUO |
|---|---|
| Origin | Shanghai, China |
| Model | RS-900B |
| Display | 7-inch capacitive touchscreen |
| Temperature Range | Ambient to 1000 °C |
| Control Method | PID programmable temperature controller with auto-segment memory |
| Furnace Tube Dimensions | Ø42 mm × 800 mm |
| Rated Power | 4 kW |
| Heating Element | Resistance wire |
| Power Supply | AC 220 V, 50/60 Hz |
| Compliance | GB/T 17650.1–2–1998, IEC 60754-1/2:1994, EN 50305, BS 6853 Annex B |
| Dual-function mode | Halogen gas evolution testing & carbon black content analysis |
| Optional accessory | Rapid cooling unit |
| Insulation material | Nano-ceramic fiber blanket |
| Integrated auxiliary modules | pH meter, conductivity meter, magnetic stirrer |
| Brand | Innuo |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | SPT-C2 |
| Pricing | Available Upon Request |
| Brand | Ion Science |
|---|---|
| Origin | UK |
| Model | TIGER Select |
| Detection Principle | Photoionization Detection (PID) with 10.0 eV UV Lamp |
| Resolution | 10 ppb (benzene) |
| Range | 0–200 ppm (with benzene pre-filter), 0–20,000 ppm (TAC mode, gas-dependent) |
| Response Time (T90) | <2 s |
| Accuracy | ±10% of reading ±1 digit (benzene) |
| Linearity | ±5% of reading ±1 digit |
| Intrinsically Safe Certification | II 1G Ex ia II C T4 Ga (Ta = –15 °C to +45 °C) |
| Battery Life | Up to 24 h (rechargeable Li-ion), 8.5 h (3×AA alkaline) |
| Data Logging | >120,000 timestamped records |
| Calibration | 2-point and 3-point via certified calibration kit |
| Alarm | Visual (amber/red LED), audible (95 dBA @ 300 mm), vibratory (pre-programmed TWA/STEL) |
| Flow Rate | 220 mL/min (low-flow alarm at 150 cc/min) |
| Operating Temp | –20 °C to +60 °C |
| Humidity | 0–99% RH (non-condensing) |
| IP Rating | IP65 |
| EMC Compliance | EN 61326-1:2006, EN 50270:2006, CFR 47 Part 15 Class A |
| Dimensions (w/o filter) | 465 × 89 × 61 mm |
| Weight (instrument only) | ~0.55 kg |
| packaged weight | 5 kg |
| Brand | IRM |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | MST260 |
| Pricing | Available Upon Request |
| Internal Volume | 305 L |
| Internal Dimensions (W×D×H) | 640 × 450 × 1060 mm |
| External Dimensions (W×D×H) | 780 × 790 × 1600 mm |
| Temperature Range | 0–80 °C (dark), 10–80 °C (with illumination) |
| Temperature Resolution | 0.1 °C |
| Temperature Uniformity | ≤ ±0.1 °C |
| Humidity Range | 20–98 %RH |
| Humidity Uniformity | ≤ ±1 %RH |
| Illumination Intensity | 0–6000 lx (±300 lx accuracy) |
| Refrigerant | R134a or R22 |
| Heating & Humidification Power | 2.0 kW |
| Cooling Capacity | 280 W |
| Power Supply | AC 220 V, 2.2 kW |
| Water Tank Capacity | 20 L |
| Standard Shelves | 2 (up to 20 configurable) |
| Weight | ~193 kg |
| Test Port | Two Ø50 mm ports (left/right) |
| Control Interface | 7-inch capacitive touchscreen |
| Operating Modes | Constant, Timer, Programmable (1–30 segments) |
| Data Logging | Event log, alarm history, real-time trend curves |
| Data Export | USB flash drive |
| Safety Protections | Leakage protection circuit breaker, independent over-temperature cutoff, water-level monitoring (low-level & overflow), compressor high-pressure/overheat protection, fan overheat protection, door-open alarm, power-failure alarm, sensor fault detection |
| Compliance Features | Audit trail, electronic signature support, 3-tier user permission system (Operator/Supervisor/Administrator), operation log with timestamp and user ID |
| Brand | Ivium |
|---|---|
| Origin | Netherlands |
| Model | IviCycle C030/C200 |
| Channels | 32 (4×8-module rack-mount configuration) |
| Voltage Range | ±10 V |
| Current Range | ±30 mA / ±200 mA |
| Potentiostat Bandwidth | >500 kHz |
| ADC Resolution | 16-bit dual-channel |
| Sampling Rate | 100 kpts/s |
| EIS Frequency Range | 10 µHz – 20 kHz |
| Data Storage | 20 million points/channel (on-board SD card) |
| Compliance | CE, RoHS |
| Interface | USB 2.0, Ethernet (LAN) |
| PC OS | Windows 10 |
| Dimensions | 44 × 26 × 22 cm |
| Weight | 12.5 kg |
| Brand | James Heal |
|---|---|
| Origin | USA |
| Model | Gyrowash |
| Capacity | 8 or 20 test cups (selectable small/large cup configuration) |
| Standards Compliance | AATCC 61, 86, 132 |
| Temperature Control | Programmable digital controller |
| Sealing System | Chemically resistant PTFE-encapsulated elastomer O-rings |
| Cup Loading Mechanism | Push-and-rotate rotor interface |
| Accessories Compatibility | Multifiber fabric, single-fiber adjacent fabrics, AATCC/ECE detergents, stainless steel balls/balls, PTFE rods, grey scales for staining and color change assessment |
| Brand | Junfang Physical & Chemical |
|---|---|
| Origin | Beijing, China |
| Model | JFQ-1150 E |
| CH₄ | 0–100% vol |
| CO₂ | 0–50% vol |
| CO | 0–20% vol |
| H₂S | 0–1.00% vol |
| O₂ | 0–25% vol |
| H₂ | 0–10% vol (optional) |
| Accuracy | ≤ ±1% FS |
| Repeatability | ≤ ±1% FS |
| Linearity | ≤ ±1% FS |
| Alarm Range | 10–90% FS (user-configurable) |
| Output | 4–20 mA analog + RS-232 digital |
| Display | Full-color TFT touchscreen |
| Preconditioning | Integrated stainless-steel gas conditioning system with pressure stabilization, primary & secondary water removal (coalescing + silica gel), particulate filtration, and automatic liquid drainage |
| Brand | Junfang Physical & Chemical |
|---|---|
| Origin | Beijing, China |
| Model | JFQ-3150E |
| Measurement Principles | NDIR (CH₄, CO₂), Electrochemical (CO, H₂S, O₂), Thermal Conductivity (H₂) |
| Gas Channels | Up to 6 configurable |
| Range | 0–100% vol (O₂, CH₄, CO₂), 0–50 ppm to 100% vol (CO, H₂S, H₂) |
| Resolution | 0.1 ppm (for trace gases) |
| Zero Drift | ≤ ±1% FS |
| Span Drift | ≤ ±1% FS |
| Linearity | ≤ ±1% FS |
| Repeatability | ≤ ±1% FS |
| Warm-up Time | 15 min |
| Response Time (T90) | ≤15 s |
| Sample Flow Rate | 0.5–3 L/min |
| Operating Temp. | 0–40 °C |
| RH | ≤90% non-condensing |
| Power | Rechargeable Li-ion battery + AC 220 V ±10%, 50 ±0.5 Hz |
| Brand | Junfang Physical & Chemical |
|---|---|
| Origin | Beijing, China |
| Model | JFQ-3150H |
| Respiratory Chamber Options | Φ100×140 mm and Φ150×250 mm |
| Simultaneous Measurement | CO₂ concentration, O₂ concentration, temperature, relative humidity |
| Dual Respiration Calculation Modes | CO₂ evolution rate and O₂ consumption rate |
| Application Environment | Ambient storage, cold storage, controlled atmosphere (CA) storage, retail refrigerated display units |
| Brand | JHX |
|---|---|
| Origin | USA |
| Model | TGA-2000 |
| Temperature Range | 50–1000 °C ±1 °C |
| Sample Mass | 0.1–5 g |
| Sample Capacity | 19 positions (configurable) |
| Weight Loss/Gain Range | 0–100% |
| Minimum Weight Resolution | 0.0002 mg |
| Compliance | ASTM D3172, ASTM D7582, ISO 1171, ISO 562, USP <731>, GLP/GMP-Ready Software Audit Trail |
| Brand | Jiada Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYJ-201SY |
| Detection Limit | 5.00 mg/kg |
| Measurement Range | 0.00–500.00 mg/kg |
| Accuracy | ±5% |
| Compliance | GB/T 2912.1–1998, GB 18401–2001 |
| Analysis Time | ≤15 min per sample |
| Display | Backlit LCD with Chinese interface |
| Control System | Embedded microcontroller |
| Data Functions | Measurement logging, statistical processing, configuration, help, and RS232 communication |
| Sample Prep | Dedicated extraction apparatus + single-use reagent kits |
| Quantitative Output | mg/kg (formaldehyde content in fabric) |
| Brand | Jiada Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (PRC) |
| Model | GDYQ-1000S |
| Function Type | Single-Analyte Dedicated Instrument |
| Sample Specificity | Soy Sauce Only |
| Detection Time | 30 minutes |
| Detection Range | 0.0–2.0 g/100 mL |
| Detection Limit | 0.1 g/100 mL |
| Accuracy | ±2% |
| Display | Backlit LCD with Chinese UI |
| Control System | Embedded MCU with Data Logging, Parameter Configuration, Statistical Processing, and RS232 Communication |
| Sample Prep | Integrated Dedicated Pretreatment Module + Single-Use Reagent Cartridge Kit |
| Brand | Jiada Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | GDYQ-100M (50 Parameters) |
| Price Range | USD 7,000 – 14,000 |
| Function Type | Multi-Analyte (Simultaneous Quantitative Screening) |
| Sample Applicability | Universal for Solid, Semi-Solid & Liquid Food Matrices |
| Optical Wavelength Range | 400 nm – 630 nm |
| Typical Analysis Time per Parameter | 3–10 minutes |
| Brand | Jiada Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | GDYQ-103SC |
| Function Type | Single-Analyte Detection |
| Sample Versatility | Multi-Matrix (Solid & Liquid) |
| Optical Wavelength | 538 nm |
| Detection Limit | 10.0 mg/kg (solid), 1.00 mg/L (liquid) |
| Quantification Range | 0.0–600.0 mg/kg (solid), 0.0–60.0 mg/L (liquid) |
| Accuracy | ±5% |
| Power Supply | AC 220 V ±22 V, 50 Hz ±1 Hz |
| Dimensions | 310 × 225 × 125 mm |
| Weight | <1.7 kg |
| Brand | Jiada Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | GDYQ-110S2 |
| Function Type | Multi-analyte (Methanol + Ethanol) |
| Sample Format | Single-sample dedicated format |
| Wavelengths | 412 nm, 595 nm |
| Brand | Jiada Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYQ-110SE2 |
| Function Type | Multi-analyte (POD, TVB-N, pH) |
| Sample Compatibility | Universal for raw meat, poultry, and aquatic products |
| Detection Limits | POD Absorbance ≥0.010 A |
| pH Resolution | 0.1 unit |
| Measurement Ranges | POD: 0.000–2.000 A |
| TVB-N | 0.0–150.0 mg/100g |
| pH | 0.2–14.0 |
| Accuracy | ±10% of full scale (per GB/T 5009.44-2003 validation protocol) |
| Interface | RS-232 & USB 2.0 |
| Data Handling | On-device storage, print output, PC synchronization |
| Brand | Jiada Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYQ-110SF |
| Function Type | Single-Analyte Quantitative Detection |
| Sample Compatibility | Multi-Sample Universal Format |
| Detection Time | 10 minutes |
| Detection Limit | 0.1 mg KOH/g |
| Measurement Range | 0.0–30.0 mg KOH/g |
| Accuracy | ±5% (Relative Standard Deviation) |
| Reference Standard | GB/T 5009.37–2003 |
| Brand | Jiada Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYQ-110SG |
| Function Type | Single-Analyte Quantitative Detection (Fatty Acid Value) |
| Sample Compatibility | Multi-sample Universal (Paddy Rice, Milled Rice, Rice Flour, and Processed Rice Products) |
| Detection Principle | Micro-titration with Standardized KOH Solution |
| Lower Detection Limit | 5.0 mg KOH / 100 g |
| Measurement Range | 0.0–500.0 mg KOH / 100 g |
| Construction | Chemically Resistant Housing & Precision Micro-burette Assembly |
| Regulatory Alignment | Designed for compliance with GB/T 20569–2006 (Chinese National Standard for Fatty Acid Value Determination in Stored Rice) and supports GLP-aligned documentation workflows |
| Brand | Jiada Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYQ-4000S |
| Function Type | Single-Analyte Detection (Iodine) |
| Sample Versatility | Multi-Sample Compatible |
| Detection Limit | 2.0 mg/kg |
| Measurement Range | 0.0–80.0 mg/kg |
| Accuracy | ±2% |
| Analysis Time | ≤3 minutes per sample |
| Display | Backlit LCD with Chinese UI |
| Control System | Embedded MCU with data logging, parameter configuration, statistical processing, and RS232 communication |
| Sample Prep | Dedicated pretreatment kit + single-use reagent cartridges |
| Brand | Jiada Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | GDYQ-501S |
| Function Type | Single-Analyte Quantitative Detection |
| Sample Compatibility | Universal for Food & Biological Matrices |
| Wavelength Range | 400–700 nm |
| Throughput | 96-well plate in 5 seconds |
| Optical Resolution | 0.001 A (display), 0.0001 A (internal calculation) |
| Photometric Repeatability | ≤ ±1% |
| Linearity | ±1% (0.000–2.000 A) |
| Absorbance Range | 0.0000–4.0000 A |
| Measurement Modes | Single-, Dual-, and Multi-Wavelength |
| Built-in Oscillation | Adjustable speed & duration |
| Interface | RS232 serial port, parallel port |
| Power Supply | AC 220 V / 110 V ±22 V, 50 Hz / 60 Hz ±1 Hz |
| Brand | Jiada Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYN-1016SD |
| Detection Method | Enzyme Inhibition Assay |
| Measurement Range | 0–100% inhibition rate |
| Number of Channels | 16 |
| Measurement Error | ±5% |
| Limit of Detection (LOD) | 0.01–3.0 mg/kg |
| Light Source | High-brightness LED |
| Wavelength | 405 nm |
| Optical Stability | ±0.005 A/20 min |
| Operating Temperature | 5–40 °C |
| Power Supply | AC 220 V ±10%, 50 Hz ±1 Hz / Built-in Rechargeable Li-ion Battery |
| Data Storage | 32 GB internal + MicroSD expansion |
| Connectivity | Micro-USB, Micro-HDMI, Wi-Fi, GPRS/EDGE |
| OS | Embedded Windows-based interface |
| Brand | Jiada Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | GDYN-1024SC |
| Price Range | USD 4,200 – 7,000 (FOB) |
| Detection Method | Enzyme Inhibition Assay |
| Measurement Range | 0–100% inhibition |
| Number of Channels | 24 |
| Measurement Error | ±6% |
| Limit of Detection (LOD) | 0.01–3.0 mg/kg |
| Light Source | Silicon Photodiode |
| Wavelength | 405 nm |
| Absorbance Range | 0.000–2.000 Abs |
| Inhibition Rate Range | 0–100% |
| Precision | ±6% |
| Detection Limit | 0.01–3.0 mg/kg |
| Brand | Jiada Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | GDYN-1096SC |
| Detection Method | Enzyme Inhibition Assay |
| Number of Channels | 96 |
| Limit of Detection (LOD) | 0.01–3.0 mg/kg |
| Inhibition Range | 0–100% |
| Inhibition Accuracy | ±6% (at 50% inhibition) |
| Throughput | Up to 192 samples per hour |
| Data Storage Capacity | 1024 records |
| Interface | RS-232 / USB |
| Display | Full-Text LCD (Chinese) |
| Reagent Compatibility | Imported cholinesterase-based reagents (500-test kit included) |
| Optical Architecture | Solid-state array light source and detector per channel |
| Expected Service Life | >10 years |
| Brand | Jiada Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYN-110SA |
| Detection Method | Enzyme Inhibition Assay |
| Number of Channels | 10 |
| Temperature Display Accuracy | ±0.5 °C |
| Colorimetric Timing Precision | ±1 s |
| Standard Reaction Time | 3 min |
| Input Voltage | 100–240 V AC |
| Rechargeable Battery Runtime | 100–150 min |
| Adjustable Incubation Time Range | 1–99 min |
| Operating Environment | Indoor & Vehicle-Mounted |
| Operating Temperature Range | 0–40 °C |
| Brand | Jiada Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYN-501MA |
| Detection Method | Thin-layer Chromatography (TLC) |
| Measurement Range | Organophosphates: 0.03–20 mg/kg |
| Carbamates | 0.03–20 mg/kg |
| Pyrethroids | 0.10–30 mg/kg |
| Organochlorines | 0.10–10 mg/kg |
| Light Source | 254 nm UV lamp |
| Warm-up Time | ≤5 min |
| Irradiance | ≥1000 µW/cm² |
| Lamp Lifetime | ≥12,000 h |
| Wavelength Repeatability | ±1 nm |
| Wavelength Accuracy | ±5 nm |
| Filter Transmittance | ≥95% |
| Spot Spacing | 5–30 mm |
| Sample Volume | 2.5–15 µL |
| Spot Diameter | ≤2.0 mm |
| Operating Temperature | 5–40 °C |
| Relative Humidity | 10–85% RH |
| Data Interface | USB 2.0 |
| Power Supply | 220 V ±22 V, 50 Hz ±1 Hz |
| Software Platform | Windows XP |
| Detection Modes | Transmission & Reflectance |
| Dimensions | 580 × 360 × 260 mm |
| Weight | 15.8 kg |
| Brand | Jiada Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYQ-1100M |
| Price Range | USD 1,400 – 7,200 |
| Detection Parameters | Moisture (0.0–27.0%), Fructose + Glucose (0.0–76.0%), Sucrose (0.0–12.0%), Acidity (0.0–100.0 mL/kg), Hydroxymethylfurfural (HMF) (0.0–100.0 mg/kg), Diastase Activity (0.0–25.0 mL/(g·h)) |
| LOD | Moisture: 12.0%, Fructose + Glucose: 13.0%, Sucrose: 3.0%, Acidity: 4.0 mL/kg, HMF: 1.0 mg/kg, Diastase Activity: 1.0 mL/(g·h) |
| Accuracy | ±2% |
| Interface | RS-232 / USB |
| Display | Backlit LCD with Chinese UI |
| Data Handling | Onboard storage, PC connectivity, statistical analysis |
| Brand | Jiada Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | GDYQ-110SU |
| Function Type | Single-Analyte Quantitative Detection |
| Sample Type | Dedicated to Wheat Flour Matrix |
| Wavelength | 538 nm |
| Detection Limit | 5.0 mg/kg |
| Measurement Range | 5.0–100.0 mg/kg |
| Accuracy | ±5% |
| Light Source | High-Brightness LED |
| Power Supply | DC 9 V |
| Dimensions | 190 × 110 × 95 mm |
| Weight | 0.4 kg |
| Included | Sample Pretreatment Kit (1 set), Reagent Kit (50 assays) |
| Brand | Jiada Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | GDYQ-1400S |
| Function Type | Single-Analyte Immunoassay Platform |
| Sample Versatility | Multi-sample Compatible (Liquid Food Matrices) |
| Wavelength Range | 400–700 nm |
| Throughput | 96-well plate in 5 seconds |
| Optical Resolution | 0.001 A (display), 0.0001 A (internal calculation) |
| Photometric Linearity | ±1% (0.000–2.000 A) |
| Absorbance Measurement Range | 0.0000–4.0000 A |
| Plate Formats | Standard 96-well and 48-well microplates |
| Filter Positions | Fixed 405 nm, 450 nm, 492 nm, 630 nm + 4 configurable slots |
| Detection Methodology | Single-, Dual-, and Multi-wavelength ELISA photometry |
| Data Processing Algorithms | Linear, Semi-log, 4PL, 5PL, Polynomial, Parabolic, Spline Curve Fitting |
| Plate Shaking | Adjustable speed and duration |
| Interface | RS232 serial port, parallel port |
| Power Supply | AC 220 V / 110 V ±22 V, 50 Hz / 60 Hz ±1 Hz |
| Brand | Jiada Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYQ-2000S |
| Detection Limit | 0.3 mmol/kg |
| Measurement Range | 0.0–11.0 mmol/kg |
| Accuracy | ±2% |
| Analysis Time | ≤5 min per sample |
| Display | Backlit LCD with Chinese UI |
| Control System | Embedded MCU with data logging, USB connectivity, and on-board statistical processing |
| Sample Prep | Integrated proprietary pre-treatment module + single-use reagent kits |
| Compliance | Modified GB/T 5009.37–2003 method |
| Brand | Jiada Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYQ-210SD |
| Function Type | Single-Analyte Detection System |
| Sample Compatibility | Multi-Matrix Food Samples |
| Detection Limit | 50.0 mg/kg |
| Quantification Range | 0.0–2000.0 mg/kg |
| Measurement Accuracy | ±5% (relative standard deviation under controlled conditions) |
| Control System | Embedded MCU-based platform |
| Data Interface | RS-232 and USB 2.0 |
| Display | Backlit LCD with Chinese UI |
| Portability | Handheld form factor, <1.2 kg |