Industry-specific Instruments
Filter
Showing 1111–1140 of 6283 results
| Brand | Elastocon |
|---|---|
| Origin | Sweden |
| Model | EB 16-II |
| Temperature Range | 40–250 °C |
| Temperature Accuracy | ±0.5 °C (40–100 °C), ±1.0 °C (101–200 °C), ±2.0 °C (201–250 °C) |
| Temperature Uniformity | ±0.25 °C (spatial & temporal) |
| Airflow Velocity | <0.001 m/s |
| Chamber Volume | 60 L |
| Sample Positions | 4 |
| Internal Dimensions (W×D×H) | 450 × 450 × 300 mm |
| External Dimensions (W×D×H) | 820 × 680 × 1460 mm |
| Weight | ~120 kg |
| Power Supply | 220–240 V, 1-phase, 50 Hz |
| Heating Power | 2200 W |
| Illumination | 10 W, 24 V halogen lamp |
| Temperature Sensor | Pt 100, 1/3 DIN class |
| Brand | Elastocon |
|---|---|
| Origin | Sweden |
| Model | EB 16-II |
| Temperature Range | 40–250 °C |
| Temperature Sensor | Pt 100 |
| Effective Chamber Volume | 60 L |
| Sample Positions | 4 |
| Airflow Velocity | < 0.001 m/s |
| Compliance | IEC 60811-2-1 (formerly IEC 811-2-1) |
| Brand | ELASTOCON |
|---|---|
| Origin | Sweden |
| Model | EB 18-II-3 |
| Temperature Range | +40 to +200 °C (HT option: +300 °C) |
| Temperature Stability | ±0.5 °C (40–200 °C), ±1.0 °C (201–300 °C) |
| Temperature Uniformity | ±0.25 °C |
| Temperature Sensor | Pt 100, 1/3 DIN |
| Number of Test Stations | 3 |
| Force Range (Compression) | 0–1000 N (optional: 100 / 500 / 1500 N) |
| Force Resolution | 0.1 N (compression), 0.01 N (tension) |
| Force Accuracy | ±0.2 N (typical, depending on range) |
| Displacement Resolution | 0.0001 mm |
| Displacement Accuracy | ±0.003 mm |
| Crosshead Speed | 0.1–200 mm/min |
| Platen Diameter | 50 mm |
| Airflow Velocity | <0.001 m/s |
| Air Exchange Rate | 3–20 cycles/hour |
| Power Supply | 220–240 V / 1 / 50 Hz or 110–120 V / 1 / 60 Hz |
| Power Consumption | 900 W |
| Dimensions (W×D×H) | 1170 × 500 × 1220 mm |
| Weight | 151 kg |
| Compliance Standards | ISO 188 Method A, ISO 3384-1, ISO 6914, ISO 899 |
| Brand | ELASTOCON |
|---|---|
| Origin | Sweden |
| Model | EB 24 |
| Temperature-Controlled Aging Chamber Base | EB 10-II |
| Air Exchange Rate | 14 cycles/hour |
| Viewing Window Dimensions | 370 × 300 mm |
| Specimen Capacity | 10 strips (25 × 100 mm) suspended via hooks |
| Load Application | Dual standard weights (1.3 kg and 2.3 kg) |
| Digital Measurement System | Laser-guided linear scale with 0.01 mm resolution |
| Maximum Elongation Range | 300 mm |
| Data Interface | RS-232 or USB to PC |
| Output Format | Raw displacement values exportable to CSV/Excel for creep strain calculation and time-dependent curve fitting |
| Brand | Elastocon |
|---|---|
| Origin | Sweden |
| Model | EB01 |
| Temperature Range (Standard) | +40 to +200 °C |
| Temperature Range (HT Variant) | +40 to +300 °C |
| Chamber Configuration | 4-unit or 6-unit modular design |
| Control Architecture | PLC-based with individual unit PID temperature control (EB19/EB20) or shared temperature control (EB01-II/EB01-IIHT) |
| User Interface | Full-color capacitive touchscreen HMI |
| Safety & Monitoring | Low-surface-temperature enclosure, integrated alarm history log, user-definable test name labeling per chamber, adjustable countdown timers per unit |
| Thermal Efficiency | Enhanced insulation reducing standby power consumption by ≥25% vs. prior generation |
| Brand | Elastocon |
|---|---|
| Origin | Sweden |
| Model | EB03 |
| Temperature Range (Heating Bath) | 40–130 °C |
| Temperature Range (Cooling Bath) | 20–80 °C |
| Temperature Accuracy | ±0.5 °C (both baths) |
| Dimensions (W×D×H, mm) | 955 × 435 × 585 |
| Weight | ~57 kg |
| Power Supply | 220–240 V, 1-phase, 50 Hz |
| Power Consumption | 2100 W |
| Cooling Water Flow Rate | 0.1–1.0 L/min (inlet ≤18 °C) |
| Optional Integrated Peltier Cooling Unit (EB03C variant) | 200 W |
| Compliance | ISO 6452, ASTM D5393 |
| Construction | Stainless steel and painted steel bath chambers |
| Brand | ELASTOCON |
|---|---|
| Origin | Sweden |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | EE 03 |
| Pricing | Available Upon Request |
| Standard Compliance | ISO 1853 |
| Measurement Range | 10⁻¹ to 10⁸ Ω·m |
| Electrode Configuration | Fixed Electrode Head with Integrated High-Sensitivity Ammeter and Selectable Voltmeter Modules |
| Key | Brand: Elastocon |
|---|---|
| Origin | Sweden |
| Model | EL-TCM |
| Temperature Range | −80 °C to +30 °C |
| Temperature Uniformity | ±0.5 °C |
| Temperature Resolution | 0.1 °C |
| Sensor Type | PT100 (1/3 DIN Class) |
| Cooling Bath Volume | ~8 L |
| Brand | Elastocon |
|---|---|
| Model | EP 02 |
| Type | Pneumatic Laboratory Sample Preparation Machine |
| Cutting Force | 18 kN (max 25 kN) |
| Operating Pressure | 6 bar (max 8 bar) |
| Stroke | 25 mm |
| Height Adjustment Range | 50 mm |
| Die Height Compatibility | 25–65 mm |
| Base Plate Dimensions | 200 × 200 mm |
| Overall Dimensions (W × D × H) | 360 × 420 × 400 mm |
| Weight | 62 kg |
| Construction Materials | Anodized Aluminum and Galvanized Steel |
| Safety | Dual-Hand Operation + Emergency Stop Button |
| Accessories | EP 02.01 Cutting Pad (200 × 200 mm) |
| Brand | Elastocon |
|---|---|
| Origin | Sweden |
| Model | EP 08 |
| Type | Manual Hydraulic-Free Cutting Press for Elastomer and Plastic Test Specimens |
| Drive | Pneumatic (EP 02 variant: 25 kN max force, 6–8 bar supply pressure, 25 mm stroke, 59 mm height adjustment range, 200 × 200 mm platen) |
| Tool Compatibility | Standardized die sets per ISO 527, ASTM D638, ISO 37, ISO 179, DIN 53504, and BS 903-A2 |
| Brand | Elastocon |
|---|---|
| Origin | Sweden |
| Model | ER-2000 |
| Compression Load Capacity | 500 / 1,000 / 2,000 N (standard: 1,000 N) |
| Tensile Load Capacity | 100 N |
| Accuracy | ±0.1% of full scale |
| Compression Resolution | 0.05 / 0.1 / 0.2 N (selectable) |
| Tensile Resolution | 0.01 N |
| Dimensions (Ø × H) | 120 × 450 mm |
| Weight | 4.5 kg |
| Construction Material | Stainless steel |
| Temperature Sensor | Pt100, 1/3 DIN Class |
| Max Operating Temperature | 200 °C (HT version: 300 °C) |
| Compliance | ISO 3384, ISO 6914, ASTM D6147 |
| Brand | Elastocon |
|---|---|
| Origin | Sweden |
| Model | ET05 |
| Standards Compliance | ISO 812, ISO 974, ASTM D746, ASTM D2137 |
| Operating Pressure | 6 bar compressed air required |
| Test Principle | Instrumented drop-weight impact with controlled cryogenic temperature ramping and real-time velocity monitoring |
| Actuation | Pneumatically driven cylinder lift mechanism with adjustable mass-height energy configuration |
| Temperature Control | Computer-regulated cooling system with integrated Pt100 sensor feedback loop |
| Post-Impact Analysis | High-speed optical velocity capture pre- and post-impact to quantify kinetic energy loss |
| Brand | Keyuan Instruments |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM/ODM Producer |
| Country of Origin | China |
| Model | Accessory Kit |
| Pricing | Upon Request |
| Brand | Electrolux |
|---|---|
| Origin | Sweden |
| Model | W555H |
| Application Standard | ISO 5077, ISO 6330, BS EN 25077 / 26330, IEC 60456 |
| Load Capacity | 6 kg |
| Drum Type | Front-loading Horizontal Rotating Drum |
| Power Supply | AC 380–400 V, 50 Hz, 4.4 kW |
| Dimensions (W×D×H) | 595 × 680 × 850 mm |
| Weight | 105 kg |
| Water Level Control | Dual-level + weight-based volumetric dosing |
| Controller | Clarus™ Electronic Programmable Controller |
| Compliance | Fully aligned with H&M MRSL, M&S Protocol P1/P1A/P3A/P12/P91/P99/P99A/P134, IWSTM-31, GB/T 8629 |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | EBT 721 / 150 / 151 / 8371 / 8372 / 8373 |
| Price | Upon Request |
| Key | Load Capacity: 2500 N |
|---|---|
| Load Resolution | 1/30000 F.S. |
| Load Accuracy | ≤ ±0.5% F.S. (2–120% of sensor range) |
| Sampling Rate | ≥200 Hz |
| Maximum Burst Stroke | 200 mm |
| Ring Clamp Inner Diameter | 25 mm |
| Indenter Ball Diameter | 20 mm |
| Indenter Descending/Retracting Speed | 10–500 mm/min (digitally adjustable) |
| Elongation Resolution | 0.1 mm |
| Data Storage Capacity | ≥4000 test records (non-volatile memory) |
| Power Supply | 220 V, 50 Hz, 1000 W |
| Dimensions (L×W×H) | 600 × 400 × 1700 mm |
| Weight | ~125 kg |
| Display | 5.7″ Sharp blue-backlit LCD with Chinese GUI |
| Control System | Mitsubishi 16-bit industrial microcontroller + 16-bit A/D converter |
| Interface Options | RS-232 printer port, USB/RS-232 PC interface (optional), optional software for force–displacement curve generation and GLP-compliant reporting |
| Brand | EMCEE |
|---|---|
| Origin | USA |
| Model | 1140 |
| Compliance | ASTM D3948, ASTM D4860 |
| Design | Integrated portable analyzer with built-in audio-guided test protocol |
| Test Duration | 5–10 minutes per sample |
| Sample Volume | Low-consumption (≤50 mL typical) |
| User Interface | Touch-sensitive control panel |
| Test Kit | Standard six-piece test assembly (pre-calibrated, disposable-compatible) |
| Brand | EMCEE |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | 1143 |
| Pricing | Upon Request |
| Brand | EMCEE |
|---|---|
| Origin | USA |
| Model | 1153 |
| Measurement Range | 0–2000 pS/m |
| Resolution | ±1 pS/m (0–2000 pS/m) |
| Accuracy | ±2% of reading |
| Operating Temperature | 0–50 °C |
| Display | 5-digit LCD with status text and LED illumination |
| Power | Three 3 V lithium batteries |
| Dimensions | 200.7 × 70 × 43.2 mm (L×W×D) |
| Probe Diameter | 19.05 mm |
| Weight | 365.8 g (12.9 oz) |
| Enclosure | Intrinsically Safe for Class I, Division 1, Group D hazardous locations |
| Compliance | ASTM D2624 |
| Optional Features | Temperature measurement mode, data hold, solvent-resistant hard-shell carrying case with O-ring sealed probe interface |
| Brand | EMCEE |
|---|---|
| Origin | USA |
| Model | JFTOT MARKIII |
| Compliance | ASTM D3241, GB/T 9169 |
| Consumables | Heating Rod & MNKJG0605 Filter Assembly |
| Supply Channel | Authorized Distributor |
| Brand | EMCEE |
|---|---|
| Origin | USA |
| Model | 1140 |
| Standard Compliance | ASTM D3948, SH/T 0616–1995 |
| Test Principle | Gravimetric optical transmittance measurement of water separation kinetics in jet fuel |
| Accessories Included | Precision glass syringes, calibrated transfer pipettes, test cuvettes, reference standards |
| Configuration | Portable benchtop unit with integrated timer and optical sensor module |
| Brand | EMCEE |
|---|---|
| Origin | USA |
| Model | 1140 |
| Compliance | ASTM D3948, SH/T 0616-1995 |
| Application | Aviation Turbine Fuel (Jet A/Jet A-1) Water Separation Performance Testing |
| Brand | EMCEE |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Model 1140 |
| Unit Price | USD 1.00 |
| Brand | EMCEE |
|---|---|
| Origin | USA |
| Model | 1140 |
| Compliance | ASTM D3948, D4860, D7224, D7261, SH/T 0616 |
| Sample Volume | 150 mL |
| Test Duration | 5 minutes per run |
| Display | Digital LCD |
| Design | Portable benchtop unit with integrated timer and full accessory set |
| Repeatability | High (±0.5 units typical under controlled conditions) |
| Brand | EMCEE |
|---|---|
| Origin | USA |
| Model | Model 1152 |
| Measurement Range | 0–1999 pS/m |
| Resolution | 1 pS/m |
| Accuracy | ±2% of reading + 1 pS/m |
| Display | 3-digit LCD, digit height 0.27 cm |
| Power Supply | 3 × alkaline batteries (6 V total) |
| Operating Temperature | 0–75 °C |
| Probe | Removable stainless-steel, intrinsically safe |
| Safety Certifications | UL, CSA (Canada), LCIE |
| Calibration | Internal reference, field-adjustable via two-button interface ("M" for Measure, "C" for Calibrate) |
| Overrange Indication | Leading "1" on display |
| Enclosure | Solvent-resistant molded polymer housing |
| Grounding | Banana jack terminal |
| Battery Low/Overrange Alerts | Visual indicators |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Model 130 |
| Pricing | Upon Request |
| Origin | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | EN388-2016 |
| Unit Packaging | 5 m² per Pack |
| Compliance | EN 388:2016 Clause 6.3, ISO 13997:1999 Annex A |
| Brand | Endecotts |
|---|---|
| Origin | United Kingdom |
| Model | Consistometer |
| Construction | Stainless steel body with electropolished 2 mm stainless steel channel |
| Sample volume | 75 mL |
| Dimensions (L × W × H) | 35.6 cm × 8.9 cm × 14.0 cm (14 in × 3.5 in × 5.5 in) |
| Base plate scale division | 0.5 cm |
| Leveling | Dual adjustable leveling screws + bubble level |
| Flow gate | Spring-loaded, instantaneous release mechanism |
| Compliance | Designed to meet ASTM D1200, ISO 2555, and AOAC Official Method 956.02 for consistency testing of semi-solid food products |
| Brand | Dongxi |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Origin Category | Domestic (China) |
| Model | GC-4085 (Configuration II) |
| Price Range | USD 42,000 – 70,000 |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | DZ3500S |
| Display | 7-inch capacitive touchscreen |
| Quartz Tube Dimensions | φ44 × 600 ± 5 mm |
| Furnace Chamber Dimensions | φ45 × 360 ± 5 mm |
| Heating Element | High-temperature alloy wire |
| Heating Zone Length | 300 mm |
| Operating Temperature Range | Ambient to 1200 °C |
| Temperature Control | Intelligent programmable multi-segment ramp/soak profile |
| Temperature Sensitivity | 0.1 °C |
| Power Supply | AC 220 V, 50/60 Hz |
| Gas Flow Control | Dual-channel, software-automated switching |
| Cooling Time | ≤20 min (from 900 °C to ambient) |
| Sample Capacity | 4 positions per run |
| Data Output | Built-in calculation engine for carbon black content and ash content |
| Optional Accessories | Exhaust filtration unit, thermal printer |
