Industry-specific Instruments
Filter
Showing 1381–1410 of 6312 results
| Brand | Fluoride (csfriend) |
|---|---|
| Origin | Hunan, China |
| Model | FDY-0801 |
| Liquid Flow Rate | 1.3–1.6 L/s |
| Temperature Control | 88 °C ±3 °C |
| Test Duration | 1064 h |
| Heating Power | 2.6 kW |
| Motor Power | 2.2 kW |
| System Pressure Range | 80–103 kPa |
| Total Power Consumption | 4.8 kW |
| Supply Voltage | AC 380 V ±10%, 50 Hz |
| Net Weight | 180 kg |
| Brand | Fluoride (csfriend) |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | FDH-1906 |
| Product Category | Laboratory Instrument |
| Input Voltage | AC 220 V ±10%, 50 Hz |
| Input Power | 2 kW |
| Temperature Control Range | Ambient to 200 °C |
| Temperature Control Accuracy | ±0.5 °C |
| Timing Range | 0–100 h |
| Brand | Fluxim |
|---|---|
| Origin | Switzerland |
| Model | Litos Lite |
| Light Source Type | Steady-State LED Solar Simulator |
| Spectral Class | AAA (IEC 60904-9 Ed. 3) |
| Number of Independent Test Channels | 56 |
| Voltage Scan Range | ±10 V |
| Maximum Current per Channel | 50 mA |
| Spectral Tunability | Yes (A++/A-Class adjustable) |
| LED Lifetime | >10,000 h |
| Temperature Control Range | RT to 150 °C |
| Environmental Control | O₂ and RH regulation |
| Compliance | ISOS-L, ISOS-O, ISOS-D protocols |
| Feedback Control | Real-time irradiance stabilization |
| Measurement Modes | J-V sweeps, MPPT, Voc, Jsc, long-term stability tracking |
| Brand | Fluxim |
|---|---|
| Origin | Switzerland |
| Model | PAIOS |
| Price Range | USD 14,000 – 70,000 |
| Automation Level | Semi-Automatic |
| Effective Test Area | 20 mm² |
| Voltage Measurement Resolution | Sub-nanovolt (nV) |
| Current Measurement Resolution | Sub-picoampere (pA) |
| Sampling Rate | 60 MS/s |
| Time Resolution | 16 ns |
| Frequency Range | 10 mHz – 10 MHz |
| LED Rise Time | 100 ns |
| Current Range | ±100 mA |
| Voltage Range | ±12 V (optional ±60 V with SMU module) |
| Spectral Coverage (Multi-LED) | 360–1100 nm |
| Temperature Range (Optional Cryo/Hot Stage) | −120 °C to +150 °C |
| Brand | FORZA |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | FT-D892-A-C/H |
| Compliance | ASTM D892, ASTM D6082, GB/T 12579, SH/T 0722 |
| Temperature Range | Ambient +5 °C to 160 °C (stability ±0.5 °C) |
| Air Flow Control | 94 ±5 mL/min (ASTM D892) or 200 ±5 mL/min (ASTM D6082), accuracy ±1% of full scale |
| Heating/Cooling Method | Forced-air bath |
| User Interface | Touchscreen with real-time parameter display and control |
| Safety | Over-temperature protection |
| Brand | Jida Xiaotian’e |
|---|---|
| Model | GDYQ-100A2 |
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Detection Limit | 5.0 mg/kg |
| Measurement Range | 0.0–500.0 mg/kg |
| Accuracy | ±2% |
| Assay Time | ≤10 min per sample |
| Display | Backlit LCD with Chinese interface |
| Control System | Embedded MCU with data logging, parameter configuration, statistical analysis, and USB/RS232 connectivity |
| Sample Prep | Dedicated extraction kit and single-use reagent cartridges |
| Compliance | Designed per GB 5009.287–2023 (National Food Safety Standard – Determination of Formaldehyde Sulfoxylate in Foods) |
| Brand | Forerunner |
|---|---|
| Model | WBS-100 |
| Origin | Beijing, China |
| Temperature Control Range | Room Temp to 60 °C |
| Temp. Accuracy | ±0.1 °C |
| Temp. Uniformity | ±0.3 °C |
| Heating Rate | 1.5 °C/min |
| Detection Cycle | 25 s per 40 cuvettes |
| Potency Calculation Time | <0.1 s |
| Absorbance Detection Precision | 0.001 A |
| Absorbance Repeatability | ±0.001 A |
| Potency Reproducibility | ≤0.5% |
| Multi-wavelength Light Source | Optional |
| UV Sterilization Lamp | Integrated |
| Audit Trail | Yes |
| User Access Control | Role-based authentication with password and RFID key |
| Brand | Forerunner |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | XQ-600 |
| Price | Upon Request |
| Measurement Range | 0–300 mg KOH/100 g dry matter |
| Resolution | 0.01 mg KOH/100 g dry matter |
| Repeatability | RSD ≤ 0.3% |
| Minimum Dispensing Volume | 0.625 µL |
| Titration Modes | Rapid Titration, Precise Titration |
| Preloaded Methods | Corn, Rice (Paddy), Wheat (100 method slots) |
| Compliance | GB/T 15684–1995, GB 5510–1985, GB/T 20569–2006, GB/T 20570–2006, GB/T 20571–2006 |
| Interfaces | RS232C, Parallel Printer Port |
| Software | Embedded real-time monitoring & PC-based data management suite |
| Brand | Forerunner |
|---|---|
| Model | ZY-400 Series |
| Origin | Beijing, China |
| Instrument Type | Automated Microbiological Assay System for β-Lactamase Detection in Milk and Dairy Products |
| Measurement Principle | Turbidimetric/Zone-of-Inhibition-Based Enzymatic Activity Quantification |
| Resolution | 0.0105 mm |
| Repeatability Precision | ≤0.02 mm |
| Inter-instrument Variation | ≤0.5% |
| Potency Reproducibility | ≤0.5% |
| Compliance Framework | Aligned with Chinese National Standard for Detection of Susceptible β-Lactamases in Milk (e.g., GB/T 22338–2008 or equivalent) |
| Brand | Forerunner |
|---|---|
| Origin | Beijing, China |
| Model | ZY-500 |
| Compliance | 21 CFR Part 11, JJF 1614–2017, USP <81>, EP 2.6.6, CP 2020 Vol II, AOAC 997.03, GB/T 5009.95–2003, SN/T 3979–2014 |
| Imaging Principle | Dual-source transmissive LED scanning with 12-line matrix CCD |
| Algorithm | AI-powered k-nearest neighbors (k-NN) image classification |
| Authentication | Fingerprint-based biometric user verification (up to 3 fingerprints per operator) |
| Security Architecture | Role-based three-tier access control, immutable audit trail, electronic signature, full data backup/recovery, write-once-read-many (WORM) raw data storage |
| Brand | Forerunner |
|---|---|
| Model | ZY-800KB |
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Pricing | Available Upon Request |
| Brand | AMC |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | T-100 |
| Motor | 1/3 HP, gear-driven with pulley transmission |
| Power Supply | 220 V, single-phase, 50/60 Hz, max. 3.5 A |
| Dimensions | 28 cm (W) × 56 cm (L) × 43 cm (H) |
| Weight | 45 kg (100 lbs) |
| Construction | 316 stainless steel frame, shaft, and beater roll |
| Disintegration Vessel | CPVC plastic pot |
| Safety | Dual interlock system + transparent polyester splash guard |
| Control | Digital revolution counter with preset stop function |
| Compliance | TAPPI T-205, ISO 5263 |
| Brand | Formulaction (Microtrac) |
|---|---|
| Origin | France |
| Model | TURBISCAN AGS |
| Light Source | 880 nm pulsed near-infrared LED |
| Measurement Principle | Multiple Light Scattering (MLS) |
| Particle Size Range | 0.05–1000 µm |
| Maximum Volume Concentration | 95% v/v |
| Temperature Control Range | RT + 5°C to 60°C |
| Temperature Accuracy | ±0.5°C |
| Scan Height | 55 mm |
| Spatial Resolution | 40 µm |
| Scan Interval | As low as 20 s per scan |
| Programmable Scan Sequences | Up to 250 |
| Sample Capacity | 54 positions |
| Dimensions (W×D×H) | 145 × 75 × 85 cm |
| Brand | Formulaction (Microtrac) |
|---|---|
| Origin | France |
| Model | TURBISCAN LAB |
| Light Source | 880 nm pulsed near-infrared LED |
| Measurement Principle | Multiple Light Scattering (MLS) |
| Particle Size Range | 0.01–1000 µm |
| Maximum Volume Concentration | up to 95% v/v |
| Temperature Control Range | RT + 5 °C to 60 °C |
| Temperature Accuracy | ±0.5 °C |
| Scan Height | 55 mm |
| Spatial Resolution | 20 µm |
| Dimensions (W × D × H) | 38 × 42 × 32 cm |
| Sample Capacity | 1 tube per run |
| Data Acquisition Modes | Full-height scanning (every 20 µm) or fixed-position kinetic monitoring |
| Brand | Formulaction (Microtrac) |
|---|---|
| Origin | France |
| Model | TURBISCAN TOWER |
| Light Source | 880 nm pulsed NIR LED |
| Measurement Principle | Multiple Light Scattering (MLS) |
| Particle Size Range | 0.01–1000 µm |
| Max. Volume Concentration | 95% v/v |
| Temperature Control Range | 4–80 °C |
| Temp. Accuracy | ±0.1 °C |
| Scan Height | 55 mm |
| Spatial Resolution | 20 µm |
| Scan Frequency | 1 scan per 20 s (at ambient) |
| Temp. Regulation Interval | Every 30 s |
| Max. Programmable Scan Steps | 250 |
| Sample Capacity | 6 positions |
| Dimensions (W×D×H) | 35 × 45 × 90 cm |
| Brand | Formulaction |
|---|---|
| Origin | France |
| Model | TRI-LAB |
| Light Source | 880 nm NIR LED |
| Sample Volume | 1.5–30 mL |
| Temperature Range | 20–60 °C |
| Sample Positions | 1–3 |
| Concentration Range | 0.0001–95% v/v |
| Detection Principle | Synchronized Transmittance (T) and Backscattering (BS) Profiling |
| Measurement Mode | Non-invasive, label-free, no dilution required |
| Compliance | Designed for GLP/GMP-aligned pharmaceutical stability assessment |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | Alphatec™ FNO |
| Application | Falling Number determination per ISO 3093, AACC 56-81B, ICC 107/1, and ASTM D7827 |
| Sample Types | Wheat, Rye, Barley, Sorghum, Flour, and other cereal-based materials |
| Measurement Principle | Viscosity-based enzymatic hydrolysis of starch gel under standardized boiling conditions |
| Display | 7-inch capacitive touchscreen interface with multilingual OS support |
| Compliance | Fully aligned with GLP/GMP data integrity requirements |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | BacSomatic |
| Automation | Fully Automatic |
| Analysis Speed | 40 samples/hour |
| Detection Range | SCC: 100,000–1,500,000 cells/mL |
| IBC | 5,000,000–20,000,000 IBC/mL |
| Repeatability | SCC: CV < 3% at 500,000 cells/mL |
| Accuracy | SCC: Typical Sy,x < 0.25 log units vs. Standard Plate Count (SPC) |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | CombiFoss 7 |
| Automation | Fully Automatic |
| Analysis Speed | Up to 600 samples/hour |
| Fat Detection Range | 0–15% |
| Repeatability (CV) | <0.5% |
| Fat Precision (CV) | <1.0% |
| Sample Types | Bovine, Ovine, Caprine, and Buffalo Milk |
| Key Parameters | Fat, True Protein, Crude Protein, Casein, Lactose, Total Solids, Non-Fat Solids, Urea, Citric Acid, Free Fatty Acids, Fatty Acid Profile, Freezing Point, pH, Ketosis Screening (BHB & Acetone), Adulteration Detection, Somatic Cell Count (SCC), Differential Somatic Cell Count (DSCC) |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | CombiFoss 7 |
| Automation Level | Fully Automatic |
| Analysis Throughput | 600 samples/hour |
| Somatic Cell Count (SCC) Range | 0–10 × 10⁶ cells/mL |
| Repeatability | < 2% CV |
| Accuracy | ±0.1–1.5 × 10⁶ cells/mL |
| Sample Temperature Range | 30–42 °C |
| Regulatory Compliance | Designed for ISO 8570, IDF 141, AOAC 991.19, and EU Regulation (EC) No 853/2004 compliance |
| Detection Capabilities | Fat, Protein, True Protein, Lactose, Total Solids, Non-Fat Solids, Urea, Citric Acid, Freezing Point, Casein, Free Fatty Acids, pH, Monounsaturated Fatty Acids (MUFA), Polyunsaturated Fatty Acids (PUFA), Total Unsaturated Fatty Acids, Total Saturated Fatty Acids, Sample Inlet Temperature, Somatic Cell Count (with FM FC module) |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | DairyScan |
| Automation | Fully Automatic |
| Analysis Time | 45 seconds per sample (15 sub-samples per run) |
| Measurement Range | Fat 0–36% w/w |
| Repeatability | ≤0.25% CV |
| Accuracy | ≤1.0% CV |
| Detection Principle | Near-Infrared (NIR) Transmission Spectroscopy |
| Sample Throughput | Up to 80 samples/hour (typical operational rate) |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | Fibertec 8000 |
| Principle | Gravimetric Crude Fiber and Detergent Fiber Analysis (Weende & van Soest Methods) |
| Sample Throughput | Up to 6 samples per run |
| Digestion Vessels | Ceramic crucibles (standardized, pre-weighed) |
| Reagent Handling | Fully automated acid/alkali/enzyme dosing and temperature-controlled digestion |
| Compliance | AOAC 978.10, AOAC 985.29, AACC 32-05, ISO 6865, EN ISO 13906 |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | Fibertec™ 1023 |
| Application Principle | Enzymatic-gravimetric method per AOAC 991.43, AOAC 2009.01, AACC 32–07, NMKL 158, and ASP methods |
| Sample Capacity | 12 samples per digestion batch, 6 samples per filtration batch |
| Digestion Vessel Volume | 600 mL |
| Water Bath Temperature Range | Ambient to 80 °C |
| Temperature Accuracy | ±0.1 °C |
| Oscillation Speed | 0–150 cycles/min |
| Oscillation Amplitude | 0–50 mm |
| Filtration Throughput | 2–4 min per 100 mL digested slurry |
| Reproducibility | RSD < 0.5% for total dietary fiber (TDF) across replicate analyses |
| Compliance | Fully aligned with AOAC Official Methods of Analysis®, ISO 13905:2014, and USP <2040> for dietary fiber quantification |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | Fossomatic 7 |
| Automation Level | Fully Automatic |
| Analysis Speed | Up to 600 samples/hour |
| Detection Range | 0–10 × 10⁶ cells/mL |
| Repeatability | CV < 4% at 500,000 cells/mL |
| Accuracy | < 10% deviation vs. direct microscopic count |
| Technology | Flow Cytometry |
| Compliance | ISO 13366-1, IDF 148, FDA/NCIMS Grade A Standards |
| Software Platform | Foss Integrator NOVA |
| Sample Types | Bovine, ovine, caprine, and buffalo milk |
| Configuration Options | Fossomatic 7 (total SCC) and Fossomatic 7 DC (somatic cell differential counting) |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | Infratec Nova |
| Instrument Type | Benchtop |
| Analysis Time | 40 s |
| Sample Mass | 5 g |
| Scan Speed | 10 s |
| Wavelength Range | 1100 nm |
| Sample Form | Whole grain or milled flour, no preparation required |
| Calibration Basis | Artificial Neural Network (ANN) with >50,000 reference samples |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | MeatMaster II |
| Technology | X-ray Transmission |
| Sample Types | Raw, chilled, or frozen meat (bone-in or boneless |
| Detection Parameters | Fat content, mass, foreign object detection (metal, bone) |
| Compliance | Designed for food processing environments meeting EU Hygiene Regulation (EC) No. 852/2004, HACCP principles, and compatible with GMP/GLP-aligned QA workflows |
| Brand | FOSS |
|---|---|
| Country of Origin | Denmark |
| Model | MilkoScan FT3 |
| Detection Parameters | Fat, Protein, Lactose, Total Solids, Non-Fat Solids, Freezing Point, Titration Acidity, Density, Free Fatty Acids, Citric Acid, Casein, Urea, Sucrose, Glucose, Fructose, Galactose |
| Automation Level | Fully Automatic |
| Analysis Time | 30 seconds per sample |
| Precision (CV) | < 0.25% (Fat, Protein, Lactose), < 0.20% (Total Solids), < 1 m°C (Freezing Point) |
| Sample Volume | < 8.0 mL |
| Flow System | Fully Automated Cleaning & Zeroing with Adaptive Adjustment |
| Connectivity | LIMS, FossManager™ Software |
| Dimensions | 750 × 450 × 408 mm |
| Weight | 43 kg |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | Milkoscan Mars |
| Automation | Fully Automatic |
| Analysis Time | 1 min per sample |
| Measurement Parameters | Fat, Protein, Lactose, Total Solids, Non-Fat Solids |
| Repeatability | ≤0.5% CV (for raw milk major components) |
| Accuracy | ≤1.2% CV (for raw milk major components) |
| Technology | Fourier Transform Infrared (FTIR) Spectroscopy |
| Compliance | Designed for ISO 9001–certified dairy QA/QC environments |
| Screening Capability | Pre-installed ASM (Adulterant Screening Module) models for urea, sucrose, formaldehyde, sodium bicarbonate, potassium nitrate, and other common adulterants |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | MilkoScan™ FT2 |
| Automation | Fully Automatic |
| Analysis Time | 30 s |
| Sample Volume Range | 4–25 mL |
| Repeatability | <0.2% CV (for fat, protein, lactose, total solids, SNF in raw milk) |
| Accuracy | <0.8% CV (for fat, protein, lactose, total solids, SNF in raw milk) |
| Operating Temperature Range | 5–55 °C |
| Carry-over | <1% |
| Optical System | Sealed, temperature-controlled FTIR interferometer |
| Calibration Methods | Intercept/slope adjustment |
| Supported Chemometric Models | PLS, modified PLS, PCA |
| Compliance | CE-marked |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | MycoFoss |
| Detection Principle | Bead-based Flow Cytometric Immunoassay |
| Sample Throughput | Up to 12 samples per run |
| Assay Time | ≤8 minutes per sample |
| Target Analytes | Aflatoxins (AFB1, AFB2, AFG1, AFG2), Deoxynivalenol (DON), Zearalenone (ZEA), Ochratoxin A (OTA), T-2 Toxin, Fumonisins (FB1, FB2, FB3) |
| Sample Types | Ground corn, wheat, and barley |
| Automation Level | Fully automated sample preparation, assay execution, and data reporting |
| Compliance Support | Audit-trail enabled, 21 CFR Part 11–ready software architecture, GLP/GMP-aligned workflow design |
| Data Management | Integrated instrument control, result traceability, PDF report generation, and CSV export |