Industry-specific Instruments
Filter
Showing 1321–1350 of 6301 results
| Brand | CSFriend |
|---|---|
| Origin | Hunan, China |
| Model | FDR-2601 |
| Temperature Control | 60 ± 1 °C |
| Measurement Principle | Potentiometric Titration |
| pH Range | 0.00–14.00 pH |
| mV Range | −1800.0 to +1800.0 mV |
| Temperature Range | −5.0 to 105.0 °C |
| pH Resolution | 0.01 pH |
| mV Resolution | 0.1 mV |
| Temperature Resolution | 0.1 °C |
| pH Accuracy | ±0.01 pH ± 1 digit |
| mV Accuracy | ±0.03 % FS |
| Temperature Accuracy | ±0.3 °C ± 1 digit |
| Burette Capacity Tolerance | ±0.025 mL (10 mL), ±0.035 mL (20 mL) |
| Burette Resolution | 1/10000 (10 mL), 2/10000 (20 mL) |
| Titration Repeatability | 0.2 % |
| Endpoint Detection Sensitivity | ±2 mV |
| Drift Stability | (±0.3 mV ± 1 digit) / 3 h |
| Power Supply | AC 220 ± 22 V, 50 ± 1 Hz |
| Dimensions (W×D×H) | 340 × 400 × 400 mm |
| Weight | 10 kg |
| Brand | CSFriend / Fuland |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | FDR-2801 |
| Vacuum Degree | 80 kPa |
| Filtration Method | Vacuum-assisted suction |
| Power Consumption | 500 W |
| Power Supply | AC 220 V / 50 Hz |
| Timer | Digital display with audible alarm |
| Noise Level | Low-noise vacuum pump |
| Construction | Stainless steel chassis with ceramic-coated control panel |
| Clamping Mechanism | Precision die-stamped metal clamps |
| Glassware Set | ASTM-compliant standard filtration glassware |
| Configuration | Single-station benchtop filtration system |
| Brand | FDR (csfriend) |
|---|---|
| Origin | Hunan, China |
| Model | FDR-4781 |
| Compliance | EN 14112 |
| Temperature Range | Ambient to 150 °C (±0.1 °C) |
| Air Flow Control | Imported Low-Noise Pump |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Brand | CSFriend |
|---|---|
| Origin | Hunan, China |
| Model | FDT-0292 |
| Test Method | Closed-Cup (Pensky-Martens) |
| Operation Mode | Fully Automatic |
| Compliant Standards | GB/T 261, ASTM D93, ISO 2719 |
| Repeatability | ±1 °C |
| Ignition Methods | Electric Spark & Gas Flame |
| Temperature Range | 10–45 °C (ambient operating) |
| Measurement Range | Room Temperature to 300 °C |
| Resolution | 0.1 °C |
| Heating Rate | 5–6 °C/min (Method A), 1–1.5 °C/min (Method B) |
| Stirring Speed | 90–120 r/min (Method A), 250±10 r/min (Method B) |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Max. Power Consumption | 500 W |
| Relative Humidity Limit | <85% RH |
| Safety Features | Over-Temperature Protection, Self-Diagnostic System, Pressure-Limited Platinum Wire Heating Control |
| Brand | CSFriend |
|---|---|
| Origin | Hunan, China |
| Model | FDT-0304 |
| Temperature Range | Ambient to –70 °C (customizable) |
| Compliant Standard | GB/T 510 |
| Cooling System | Imported Refrigeration Compressor |
| Control Accuracy | ±0.5 °C |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Max Power Consumption | ≤1000 W |
| Operating Environment | ≤30 °C, RH ≤85% |
| Display | LCD with Bilingual (Chinese/English) Interface |
| Timing & Alert | Automated Timing and Audible/Visual Alerts |
| Temperature Calibration | Built-in Offset Correction and Calibration Functionality |
| Brand | FuLand / csfriend |
|---|---|
| Measurement Range | 2–100 mN/m (for insulating oils) |
| Sensitivity | 0.1 mN/m |
| Repeatability | ±0.3% |
| Accuracy | ±0.1 mN/m |
| Resolution | 0.1 mN/m |
| Power Consumption | 20 VA |
| Operating Temperature | 10–30 °C (typical at 25 °C) |
| Relative Humidity | 20–75 %RH |
| Supply Voltage | AC 220 V ±5%, 50 Hz |
| Net Weight | 15 kg |
| Microcontroller Architecture | High-Capacity Embedded MCU |
| Display | Full-Color LCD Touchscreen Interface |
| Data Handling | Auto-calibration via multi-point linear regression (mg = f(Δ-result)), real-time clock, non-volatile memory backup, auto-lift mechanism, integrated thermal printer |
| Brand | SDL Atlas |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | M034E |
| Price Range | USD 6,800 – 13,600 |
| Standard Compliance | ASTM D1777-2, ASTM D751-06, ISO 5084, ISO 9863-1, ISO 964-1 (2 kPa), ASTM D1621, D5199, D461, D3652 |
| Foot Diameter | 9.5 mm |
| Applied Load | 143 g (≈1.4 kPa) |
| Base Material | Laboratory-grade granite |
| Base Dimensions | 150 × 160 × 50 mm |
| Column Height | 200 mm |
| Indicator | Certified digital display with SPC output (RS-232), dual-language (English/metric), auto-power-off, left-hand lift handle |
| Brand | Ayalytical |
|---|---|
| Model | FeDDI |
| Origin | USA |
| Type | Automated Image-Based Corrosion Quantification Instrument |
| Compliance | ASTM D665, GB/T 11143, NACE TM-0172 |
| Brand | Fengtu |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | FT-P108 |
| Price | USD 4,500 (FOB Qingdao) |
| Sample Capacity | 8 × 0.2 mL tubes |
| Temperature Range | 4–99 °C |
| Thermal Accuracy | ±0.1 °C |
| Temperature Uniformity | ≤±0.25 °C |
| Max Heating/Cooling Rate | 5.5 / 5.0 °C/s |
| Excitation Wavelength | 460–480 nm |
| Emission Detection Range | 505–525 nm |
| Sensitivity | Single-copy DNA detection |
| Dynamic Range | 10¹–10¹⁰ copies |
| Linearity (R²) | ≥0.999 |
| Inter-well CV | <1% |
| Supported Chemistries | SYBR Green I, FAM |
| Optical System | High-power LED + Photodiode detector |
| Control Interface | Built-in Android touchscreen + PC software |
| Data Export | CSV, PDF, Excel |
| Compliance | CE-marked, ISO 13485-aligned design principles |
| Brand | Fengtu |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | FT-SD2 |
| Price | USD 12,200 (FOB Qingdao) |
| Brand | Fengtu |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | TQ-BZ2 |
| Price | USD 3,200 (FOB) |
| Power Supply | 220 VAC / Optional 480 W–200 Ah Solar Kit |
| Operating Temperature | −20 °C to +70 °C |
| Relative Humidity | 0–95% RH (non-condensing) |
| Dimensions | 600 × 640 × 1418 mm |
| Imaging Sensor | 8 MP CMOS |
| Microscopy Resolution | Capable of resolving spores 5–100 µm in diameter |
| Sampling Area | 50 × 21 mm per capture cycle |
| Sampling Duration | Adjustable from 60 to 1200 minutes |
| Data Transmission | 4G LTE (TCP/IP), DNS-enabled, SIM-based |
| Display | 10.4″ TFT-LCD with Windows 10 OS |
| Power Consumption | ≤65 W (startup), ≤50 W (operational), ≤26.4 W (standby) |
| Insulation Resistance | ≥2.5 MΩ |
| Slide Carrier Lifespan | Up to 365 days at 3 captures/day |
| Motorized Stage | Dual-axis (X/Y) precision stepper control |
| Airflow Design | Optimized laminar ducting for reduced particle re-entrainment and improved collection efficiency |
| Brand | Beijing Hangfeng |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (PRC) |
| Model | FYH-M |
| Pricing | Available Upon Request |
| Brand | Shanda Instruments |
|---|---|
| Model | FERRITE-CHECK 240 |
| Measurement Range | 0.2–100 Fe% / 0.2–140 FN |
| Accuracy | <5% |
| Operating Temperature | 0–50 °C |
| Calibration Standards | 3 certified ferrite reference blocks |
| Power Supply | 3 × 1.5 V AA batteries or USB-C external power |
| Compliance | DIN EN ISO 8249 |
| Display | 320 × 480 pixel color LCD touchscreen |
| Data Storage | 10,000 measurements with statistical analysis (min/max/mean/std dev) |
| Connectivity | Bluetooth 5.0 (Android/iOS/Windows compatible) |
| Software | Lima Connect (free PC/mobile application) |
| Dimensions | 150 × 85 × 35 mm |
| Weight | 320 g (including batteries) |
| Minimum Test Area | Ø 2 mm |
| Resolution | 0.1 Fe% / 0.1 FN |
| Battery Life | ~25 h continuous operation |
| Brand | Kittiwake |
|---|---|
| Origin | United Kingdom |
| Model | FG-K30258-KW |
| Measurement Range | 0–2500 ppm |
| Sample Vessel | Standard 5 mL Test Tube |
| Analysis Time | <3 seconds |
| Portability | Field- and Lab-Deployable |
| Brand | BiAgro (RockTec) |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | FHI-Bot |
| Pricing | Available Upon Request |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MA2 |
| Pricing | Available Upon Request |
| Brand | SDL Atlas |
|---|---|
| Origin | USA |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Imported |
| Model | F025A |
| Price Range | USD 4,200 – 7,000 |
| Brand | ficonTEC |
|---|---|
| Origin | Germany |
| Model | customized-36 |
| Configuration | Modular AOI Platform with Integrated Wafer/Chip Handling and Real-time Defect Classification |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | FieldLab 58C |
| Product Type | Portable Instrument |
| Detection Modules | XRF Elemental Analysis |
| Test Time per Sample | <10 minutes |
| Sample Volume Required | 12 mL |
| Compliance | ASTM D6595, D7690, D7883, D445 |
| Interface | Touchscreen with Embedded Diagnostic Software |
| Power | Rechargeable Battery |
| Enclosure | Ruggedized Transport Case Integrating All Four Modules |
| Brand | Fischer |
|---|---|
| Origin | Germany |
| Model | FERITSCOPE_FMP30 |
| Measurement Range | 0.1–110 FN or 0.1–80% Fe |
| Accuracy | ±0.1% Fe (relative) |
| Operating Temperature | Ambient (15–30 °C) |
| Calibration Standards | Five certified reference samples covering 0.3–80% Fe |
| Compliance | DIN 32514-1, Basler Norm |
| Power Supply | Rechargeable battery or AC adapter |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FMP30 |
| Pricing | Upon Request |
| Brand | Fitlylab |
|---|---|
| Origin | Shenzhen, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | FITLY-9616 |
| Function Type | Multi-analyte (Simultaneous Detection of 30+ Food Contaminants & Additives) |
| Sample Compatibility | Liquid, Solid, Semi-solid Extracts (Homogenized or Centrifuged) |
| Wavelength Range | 410–900 nm (Fixed LED Sources at 410, 536, 595, 620 nm) |
| Detection Channels | 16-Channel Photometric Array |
| Photometric Repeatability | ≤ ±1% T |
| Immunoassay Detection Mode | Single-Channel CCD-Based Lateral Flow Reader (3-Megapixel, 2048×1536 Resolution, Reflective T/C Quantification) |
| T/C Accuracy | ≤ ±0.1 T/C |
| T/C Precision (CV) | ≤ 5% |
| Stability | ≤ 0.1 T/C over 10 min |
| Assay Time | <10 s per lateral flow strip |
| Data Export Format | Excel (.xlsx) |
| Connectivity | USB 2.0, Wi-Fi 802.11 b/g/n, Bluetooth 4.2, 10/100 Mbps Ethernet |
| Onboard Storage | 32 GB SSD |
| RAM | 4 GB |
| CPU | Dual-core 1.6 GHz |
| Display | 10.2-inch Full-color Capacitive Touchscreen |
| Weight | ≤ 3.0 kg |
| Brand | Fitlylab |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | RVLM |
| Function Type | Multi-analyte Detection Platform |
| Sample Compatibility | Solid, Liquid, Surface, Paste, and Slurry Samples |
| Optical Detection | Triple-wavelength Simultaneous Photometric Analysis |
| Detection Channels | 8 Independent Wells |
| Detection Time | Inversely Proportional to Target Microbial Load (as low as <2 h for ≥10⁸ CFU/mL) |
| Repeatability | High (CV <15% under standardized conditions) |
| Regulatory Compliance | ISO 16140:2003 Validated Alternative Method |
| Brand | FlameTech (csfriend) |
|---|---|
| Origin | Hunan, China |
| Model | FDT-0101 |
| Test Method | Cleveland Open-Cup (COC) |
| Temperature Range | –6 °C to 400 °C |
| Compliance Standard | GB/T 3536 |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Heating Power | 0–600 W, continuously adjustable |
| Ignition Source | Liquefied petroleum gas (LPG) or natural gas |
| Flame Tip Orifice Diameter | 0.6–0.8 mm |
| Thermometer Range & Accuracy | –6 °C to 400 °C, graduation 2 °C, compliant with GB/T 514 |
| Sweep Mechanism | Motor-driven automatic test flame sweep |
| Enclosure Material | Stainless steel work surface and furnace housing |
| Max. Power Consumption | ≤650 W |
| Operating Ambient | –10 °C to 50 °C, RH ≤85% |
| Safety Features | Integrated flame-extinguishing lid for fire point determination |
| Construction | Benchtop, explosion-resistant quartz-tube heating furnace |
| Brand | FlanD / csfriend |
|---|---|
| Origin | Hunan, China |
| Model | FDH-1502 |
| Applicable Standards | GB/T 9171, ASTM D4684, SH/T 0562 |
| Temperature Range | –50 °C to +80 °C |
| Sample Capacity | 9-position test block |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Cooling System | Imported compressor-based refrigeration unit |
| Detection Method | Optical encoder-based rotor speed measurement |
| Control Interface | Touchscreen with bilingual (English/Chinese) OS |
| Software | FLD proprietary BPT analysis software with real-time timing, auto-diagnosis, and single-point calibration capability |
| Optional Feature | Integrated nitrogen purge port |
| Design | Integrated monolithic chassis |
| Brand | FlanD / csfriend |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | FDH-2801 |
| Pricing | Upon Request |
| Standard Compliance | ISO 9950, JB/T 7951, SH/T 0220 |
| Temperature Range | 0–900 °C |
| Sampling Rate | 260 Hz |
| Probe Material | Inconel 600 (Ni–Cr–Fe alloy) |
| Probe Dimensions | Ø12.5 mm × 60 mm |
| Data Output | Dual-curve display (cooling curve + cooling rate curve), 5-group comparative analysis |
| Interface | USB, RS-232, LIMS-compatible |
| Control System | Integrated FlanD Automatic Control Module |
| Software Environment | Windows XP and later (32-bit) |
| Data Management | Folder-based archival with auto-timestamped files (date/time embedded in metadata) |
| Correction | User-configurable probe correction coefficient (based on peak cooling rate or full-curve fitting) |
| Reporting | A4/B5 formatted printouts including cooling parameters (e.g., time to 700 °C, 300 °C |
| Brand | Fland |
|---|---|
| Origin | Hunan, China |
| Model | FDR-0271 |
| Analysis Method | ASTM D323 (Reid Method) |
| Pressure Range | 0–200 kPa (0–29 psi) |
| Temperature Control | 37.8 ± 0.1 °C |
| Sample Capacity | 3 bomb units |
| Power Consumption | 1.5 kW |
| Compliance | ASTM D323, IP 121, GB/T 8017, ISO 3016 |
| Brand | Fland (csfriend) |
|---|---|
| Model | FDR-0571 |
| Standard Compliance | GB/T 8019 |
| Temperature Range | Ambient to 200 °C |
| Temperature Resolution | 0.01 °C |
| Display | 7-inch Touchscreen (Chinese/English Optional) |
| Weighing Precision | 0.0001 g (Integrated METTLER Toledo Analytical Balance) |
| Power Supply | 220 V, 50 Hz |
| Data Export Interface | Optional RS232/USB for LIMS Integration |
| Brand | Fland (csfriend) |
|---|---|
| Origin | Hunan, China |
| Model | FDR-0871 |
| Temperature Range | 0–400 °C |
| Temperature Accuracy | ±0.1 °C |
| Cold Bath Range | −10 to 80 °C |
| Distillation Rate | 4–5 mL/min |
| Volume Measurement Range | 1–100 mL |
| Volume Resolution | 0.1 mL |
| Heating Power | 2 kW |
| Refrigeration Power | 1 kW |
| Refrigeration Control Accuracy | ±1 °C |
| Steam Temperature Sensor Range | 0–400 °C |
| Furnace Temperature Sensor Range | 0–500 °C |
| Refrigeration Sensor Range | 0–100 °C |
| Brand | Fland (csfriend) |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | FDR-4291 |
| Pricing | Available Upon Request |
| Measurement Principle | Dual-channel NDIR (Non-Dispersive Infrared) Spectroscopy |
| Gas Components Measured | CH₄ (0–100% vol), CnHm (0–10% vol) |
| Resolution | 0.01% for both CH₄ and CnHm |
| Accuracy | ±1% FS for both channels |
| Zero Calibration | Automatic via integrated sampling pump |
| Display | 320 × 240 graphical LCD |
| Output Interface | RS232 digital serial port |