| Brand | GASTEC |
|---|---|
| Origin | Japan |
| Model | GASTEC Oxygen Detection Alarm (Portable) |
| Detection Principle | Electrochemical Sensor |
| Operating Range | 0–25% vol O₂ |
| Resolution | 0.1% vol |
| Accuracy | ±0.5% vol (within 15–25% range) |
| Response Time (T90) | <30 s |
| Power Supply | Rechargeable Li-ion battery (up to 2,000 hours continuous operation) |
| IP Rating | IP67 |
| Operating Temperature | −10°C to +50°C |
| Compliance | IEC 61508 SIL 2, JIS T 8201, EN 45544-1, ATEX II 2G Ex ib IIC T4 Gb |
| Origin | Tianjin, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Regional Origin | Domestic (PRC) |
| Model | GB/T 24654 |
| Price Range | USD 7,000 – 14,000 |
| Sample Dimensions | 110 mm width × 180–200 mm length |
| Hammer Mass | 1000 ± 10 g and 2000 ± 10 g (including auxiliary 1000 g weight) |
| Drop Height | Adjustable from 50 to 75 cm |
| Impact Energy Calculation | Based on real-time photogate-measured drop velocity and hammer mass (Joules) |
| Blade Specifications | 10 mm cutting edge length, 0.2R mm tip radius, 60° included angle, SK-3 tool steel, 58 HRC hardness |
| Drop Mechanism | Electromagnetic release with fail-safe mechanical brake |
| Timing Resolution | 0.1 ms (0–999 ms range) |
| Velocity Display | 0.0–9.9 m/s |
| Control Interface | Industrial-grade capacitive touchscreen HMI |
| Brand | TianYuan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model Designation | ASTM-Compliant |
| Pricing | Available Upon Request |
| Brand | Jiubin Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JB-2300 |
| Pricing | Upon Request |
| Power Consumption | <5 W (Standby: 1 W) |
| Internal Power Supply | DC 9.6 V / 1200 mAh Ni-MH Battery |
| External Power Input | DC 12 V |
| Communication Interface | Standard 9-pin RS232 (TXD on Pin 3, RXD on Pin 2, GND on Pin 5) |
| Baud Rate | 9600, 8 Data Bits, 1 Stop Bit, No Parity |
| Dimensions | 205 × 145 × 55 mm |
| Weight | 1.0 kg (including battery) |
| Operating Temperature | −15 °C to +45 °C |
| Relative Humidity | 30–80 % RH |
| Brand | GBPI |
|---|---|
| Thickness | 125 μm |
| Material | Biaxially Oriented Polyethylene Terephthalate (BOPET) |
| Certified Reference Material (CRM) Designation | GBW(E)130541 |
| Compliance | GB/T 1038–2000 (Differential Pressure Method) |
| Certification Level | China National Secondary Standard Substance |
| Origin | Guangdong, China |
| Manufacturer | Guangzhou GBPI Instrument Co., Ltd. |
| Brand | GBPI (Guangzhou Biaoji) |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Region Classification | Domestic (China) |
| Model | AUTO GBM-L2 |
| Pricing | Upon Request |
| Absolute Pressure Range | 0–300 kPa |
| Differential Pressure Range | −2 to +2 kPa |
| Detection Sensitivity | 1–3 µm |
| Equilibration/Test Time | 1–3600 s |
| Vacuum Purge Time | 1–3600 s |
| Set Flow Rate | 0–3 mL/min |
| Sensor Configuration | Dual-sensor (absolute + differential pressure) |
| Test Chamber | Custom-engineered per sample geometry |
| Compliance Standards | ASTM F2338-09(2013), YY/T 0681.18–2020, USP <1207.2>, ASTM F2095 |
| Brand | GBPI (Guangzhou Biaoji) |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Region Classification | Domestic (China) |
| Model | GBM-L2A |
| Price | USD 42,000 (approx.) |
| Absolute Pressure Range | 0–300 kPa |
| Differential Pressure Range | −2 to +2 kPa |
| Detection Sensitivity | 1–3 µm |
| Equilibration/Test Duration | 1–3600 s |
| Vacuum Purge Time | 1–3600 s |
| Set Flow Rate | 0–3 mL/min |
| Sensor Configuration | Dual-sensor (absolute + differential pressure) / Dual-loop testing system |
| Test Chamber | Custom-engineered per sample geometry |
| Compliance Standards | ASTM F2338-09(2013), YY/T 0681.18–2020, USP <1207.2>, ASTM F2095 |
| Brand | GBPI (Guangzhou GBPI Packaging Instruments) |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | AUTO GBM-L2A |
| Price | USD 42,000 (FOB Guangdong) |
| Absolute Pressure Range | 0–300 kPa |
| Differential Pressure Range | −2 to +2 kPa |
| Detection Sensitivity | 1–3 µm |
| Equilibration/Test Time | 1–3600 s |
| Vacuum Purge Time | 1–3600 s |
| Set Flow Rate | 0–3 mL/min |
| Sensor Accuracy | ±0.1% FS (Absolute & Differential) |
| Test Chamber | Custom-Fabricated per Sample Geometry |
| Power Supply | AC 220 V, 50 Hz |
| Ambient Temp. | 20–30 °C |
| Relative Humidity | ≤80% RH (non-condensing) |
| Dimensions (W×D×H) | 495 × 455 × 280 mm |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Producer |
| Country of Origin | China |
| Model | AUTO GQ300 |
| Price | Upon Request |
| Gas Measurement Range | O₂: 0–30% (v/v), CO₂: 0–20% (v/v), C₂H₄: 0–200 ppm |
| Gas Measurement Accuracy | O₂: ±0.01%, CO₂: ±0.01%, C₂H₄: ±0.1 ppm |
| Gas Purity Requirement | ≥99.9% for O₂, CO₂, N₂, and C₂H₄ |
| Gas Flow Control | O₂/CO₂/N₂: 0–500 mL/min each |
| Temperature Range | −5°C to +45°C |
| Temperature Uniformity & Stability | ±0.5°C |
| Humidity Range | Ambient to 95% RH |
| Humidity Fluctuation | ±3% RH |
| Refrigeration Capacity | 1 HP |
| Humidifier Power | 50 W |
| Illumination Power | 10 W |
| Chamber Material | Color-coated steel exterior, stainless-steel interior |
| Dimensions (W×D×H) | 935 mm × 1290 mm × 1850 mm |
| Total Power Consumption | 3 kW |
| Number of Independent Test Chambers | 3 |
| Power Supply | AC 220 V |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (PRC) |
| Model | BFH-960-aa |
| Pricing | Available Upon Request |
| Spectral Range | 7800–350 cm⁻¹ |
| Resolution | <1.0 cm⁻¹ |
| Signal-to-Noise Ratio | >15,000:1 (4 cm⁻¹, 1-min scan) / >30,000:1 (4 cm⁻¹, 1-min scan) |
| Beamsplitter | Ge-coated KBr substrate |
| Detector | Imported high-sensitivity deuterated triglycine sulfate (DLaTGS) |
| Source | Imported long-life, air-cooled high-intensity IR source |
| Wavenumber Accuracy | ±0.01 cm⁻¹ |
| Transmittance Precision | ±0.5%T |
| Interferometer | Sealed 30°-incidence Michelson interferometer with built-in auto-alignment optics |
| Laser | VCSEL-based He–Ne equivalent reference laser (≥10-year lifetime) |
| A/D Conversion | 24-bit, 500 kHz |
| Interface | USB 2.0 (backward/forward compatible with USB 3.0) |
| Operating Temperature | 15–35 °C |
| Dimensions | 450 × 350 × 235 mm (L×W×H) |
| Weight | 14 kg |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | CHY-G |
| Pricing | Upon Request |
| Measurement Principle | Capacitive Grid Sensing |
| Display | 7-inch Color Touchscreen LCD |
| Control System | Microcomputer-based |
| Thickness Range | 0–12.7 mm |
| Resolution | 0.001 mm (0.00005″) |
| Sample Diameter | 5–300 mm (customizable) |
| Sample Height | 5–330 mm (customizable) |
| Dimensions (L×W×H) | 400 × 360 × 700 mm |
| Interface | USB |
| Operating Temperature | 15–50 °C |
| Relative Humidity | 10–90% RH (non-condensing) |
| Power Supply | 220 V AC, 50 Hz, 60 W |
| Compliance | YBB00332002-2015, YBB00332003-2015, YBB00032004-2015, GB 12415-90 |
| Data Management | Built-in statistical analysis (max/min/mean), audit trail, user-level permission control, thermal printer integration |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | CYLLX |
| Pricing | Upon Request |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | FT-01 |
| Pricing | Upon Request |
| Measurement Range | 0.02–50,000 cm³/m²·day·0.1 MPa (expandable to 600,000 cm³/m²·day·0.1 MPa) |
| Measurement Resolution | 0.01 cm³/m²·day·0.1 MPa |
| Temperature Range | 5–50 °C |
| Temperature Control Accuracy | ±0.01 °C |
| Humidity Range | 0 %RH (5–100 %RH optional) |
| Humidity Control Accuracy | ±2 %RH |
| Vacuum Accuracy | 0.1 Pa |
| Test Chamber Vacuum Level | <20 Pa |
| Test Pressure Range | −0.1 to +0.1 MPa |
| Test Gases | O₂, CO₂, N₂ |
| Max. Sample Thickness | ≤2 mm |
| Test Area | 50.24 cm² (Φ80 mm) |
| Power Supply | 220 V AC, 50 Hz |
| Brand | GBPI |
|---|---|
| Model | GB-B20010 |
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Pressure Points | 3 kPa, 5 kPa, 7 kPa, 14 kPa, 20 kPa |
| Specimen Size | 75 mm × 75 mm |
| Pressurized Area | 28.27 cm² |
| Power Supply | AC 220 V, 50 Hz, 100 W |
| Air Source | Compressed Air |
| Pressure Regulation | Adjustable, with Analog Pressure Gauge |
| Clamping Torque | 13.5 N·m |
| Retention Mesh | Stainless Steel, Open Area ≥50%, Deflection ≤5 mm at 20 kPa |
| Timer | Digital, ±1 s Accuracy |
| Compliance | GB 19083–2010 |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GB-BF20010 |
| Pressure Test Points | 3 kPa, 5 kPa, 7 kPa, 14 kPa, 20 kPa |
| Specimen Size | 75 mm × 75 mm |
| Pressurized Area | 28.27 cm² |
| Power Supply | AC 220 V, 50 Hz, 100 W |
| Air Pressure Source | Adjustable compressed air up to (20 ± 1) kPa |
| Pressure Display | Analog pressure gauge with manual regulation |
| Test Chamber | Stainless steel penetration test chamber with leak-resistant sealing |
| Support Grid | Square metal retainer mesh, ≥50% open area, deflection ≤5 mm at 20 kPa |
| Clamping Torque | 13.5 N·m |
| Timer | Digital display timer, accuracy ±1 s |
| Brand | GBPI |
|---|---|
| Model | GB-BF20010A |
| Pressure Settings | 3, 5, 7, 14, 20 kPa |
| Test Area | 28.27 cm² (75 mm × 75 mm specimen) |
| Air Supply | Compressed air, regulated to (20 ± 1) kPa |
| Power Supply | AC 220 V, 50 Hz, 100 W |
| Timer Resolution | ±1 s |
| Clamp Torque | 13.5 N·m |
| Retention Mesh | ≥50% open area, ≤5 mm deflection at 20 kPa |
| Construction | Stainless steel test chamber with integrated specimen retention system |
| Brand | GBPI |
|---|---|
| Model | GB-BF20010CT |
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Pressure Settings | 3 kPa, 5 kPa, 7 kPa, 14 kPa, 20 kPa |
| Specimen Size | 75 mm × 75 mm |
| Pressurized Area | 28.27 cm² |
| Power Supply | AC 220 V, 50 Hz, 100 W |
| Air Source Requirement | Compressed air capable of delivering (20 ± 1) kPa |
| Clamp Torque | 13.5 N·m |
| Retention Mesh | ≥50% open area |
| Timer Resolution | ±1 s |
| Test Medium | ASTM F1862-compliant synthetic blood surrogate |
| Brand | GBPI |
|---|---|
| Model | GB-BF20010M |
| Pressure Settings | 3, 5, 7, 14, 20 kPa |
| Test Area | 28.27 cm² (75 mm × 75 mm specimen) |
| Air Supply | Compressed air, regulated to (20 ± 1) kPa |
| Power | AC 220 V, 50 Hz, 100 W |
| Timer Resolution | ±1 s |
| Clamp Torque | 13.5 N·m |
| Retention Mesh | ≥50% open area, ≤5 mm deflection at 20 kPa |
| Construction | Stainless steel test chamber |
| Brand | GBPI |
|---|---|
| Model | GB-DK |
| Measurement Principle | Fluorescence-based Optical O₂ Detection & NDIR CO₂ Detection |
| Measuring Gases | O₂ (standard), CO₂ (optional) |
| O₂ Range | 0–25% vol |
| CO₂ Range | 0–100% vol |
| O₂ Accuracy | ±0.2% vol |
| CO₂ Accuracy | ±2% vol |
| Minimum Sample Volume | ≥3 mL (at 101.3 kPa) |
| Sampling Method | Vacuum-assisted needle puncture |
| Dimensions | 350 × 330 × 200 mm (L×W×H) |
| Weight | 5 kg |
| Power Supply | 220 VAC ±10%, 50 Hz / 120 VAC ±10%, 60 Hz |
| Compliance | Designed per Annex 11 (EU GMP), FDA 21 CFR Part 11, and ISO 11607-2 requirements for packaging integrity validation |
| Brand | GBPI |
|---|---|
| Model | GB-DK1 |
| Measurement Principle | Fluorescence-based Optical O₂ Detection & NDIR CO₂ Detection (optional) |
| Gas Types | O₂ (standard), CO₂ (optional) |
| O₂ Range | 0–25% vol |
| CO₂ Range | 0–100% vol |
| O₂ Accuracy | ±0.2% vol |
| CO₂ Accuracy | ±2% vol |
| Minimum Sample Volume | ≥3 mL (at 101.3 kPa) |
| Dimensions | 350 × 330 × 200 mm (L×W×H) |
| Power Supply | 220 VAC ±10%, 50 Hz / 120 VAC ±10%, 60 Hz |
| Net Weight | 5 kg |
| Compliance | Designed per GMP Annex 11 (Computerized Systems), supports ALCOA+ data integrity principles |
| Operating Environment | Production line, warehouse, QC lab |
| Brand | GBPI |
|---|---|
| Model | GB-DK1E |
| Measurement Principle | Fluorescence-based Optical O₂ Detection & NDIR CO₂ Detection (optional) |
| Gas Range | O₂ 0–25% (±0.2% accuracy), CO₂ 0–100% (±2% accuracy) |
| Sampling Volume | ≥5 mL (O₂), ≥20 mL (CO₂) |
| Dimensions | 350 × 330 × 200 mm |
| Weight | 5 kg |
| Power | 220 VAC ±10%, 50 Hz / 120 VAC ±10%, 60 Hz |
| Compliance | Designed per GMP Annex 11 & FDA 21 CFR Part 11 requirements for computerized systems |
| Operating Environment | Lab, QC, warehouse, or inline packaging environments |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | GB-F1 |
| Pricing | Upon Request |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | GB-FB1 |
| Pricing | Upon Request |
| Test Standards | GB 10006, ISO 8295, ASTM D1894, TAPPI T816 |
| Friction Coefficient Range | 0.001–0.999 |
| Resolution | 0.1 |
| Force Measurement Range | 0–9.8 N |
| Slider Velocity | 0–500 mm/min (infinitely variable |
| standard test speeds | 100 ±10 mm/min and 150 ±10 mm/min) |
| Stroke Length | 100 ±5 mm |
| Max Sample Thickness | ≤2 mm |
| Slider Dimensions | 63 mm × 63 mm |
| Slider Mass | 200 g ±2 g |
| Test Platform Size | 200 mm × 470 mm |
| Display | LCD screen |
| Overall Dimensions | 470 mm × 340 mm × 220 mm |
| Power Consumption | 100 W |
| Electrical Supply | AC 220 V ±10 V, 50 Hz |
| Net Weight | 13.6 kg |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GB-HQ1000 |
| Price Range | USD 14,000 – 42,000 |
| Air Source | Compressed Air |
| Vacuum Pump Flow Rate | 2 L/min |
| Buffer Tank Volume | 5 L |
| Pressure Sensor Range | −1000 Pa to 0 Pa |
| Pressure Sensor Accuracy | ±1% FS |
| Pressure Resolution | 1 Pa |
| Flow Meter Range | 0–100 mL/min |
| Flow Meter Accuracy | ±1% FS |
| Flow Resolution | 0.1 mL/min |
| Display | Integrated HD Touchscreen Interface |
| Power Supply | 220 V AC, 50 Hz |
| Brand | GBPI |
|---|---|
| Model | GB-HQ1000A |
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Price Range | USD 14,000 – 42,000 |
| Air Source | Compressed Air |
| Vacuum Pump Flow Rate | 2 L/min |
| Buffer Tank Volume | 5 L |
| Pressure Sensor Range | −1000 Pa to 0 Pa |
| Pressure Sensor Accuracy | ±1% FS |
| Pressure Resolution | 1 Pa |
| Flow Meter Range | 0–100 mL/min |
| Flow Meter Accuracy | ±1% FS |
| Flow Resolution | 0.1 mL/min |
| Display | Integrated HD Touchscreen Interface |
| Power Supply | 220 V AC, 50 Hz |
| Sample Holder | Dedicated Mask Valve Fixture |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GB-HQ1000C |
| Price Range | USD 14,000 – 42,000 |
| Air Source | Compressed Air |
| Vacuum Pump Flow Rate | 2 L/min |
| Buffer Chamber Volume | 5 L |
| Pressure Sensor Range | −1000 Pa to 0 Pa |
| Pressure Sensor Accuracy | ±1% FS |
| Pressure Resolution | 1 Pa |
| Flow Meter Range | 0–100 mL/min |
| Flow Meter Accuracy | ±1% FS |
| Flow Resolution | 0.1 mL/min |
| Display | Integrated HD Touchscreen Interface |
| Power Supply | 220 V AC, 50 Hz |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Region | Domestic (China) |
| Model | GB-KF30010 |
| Pricing | Upon Request |
| Filtration Efficiency Range | 0–99.999% |
| Flow Rate Range | 10–100 L/min (Accuracy Class 2.5) |
| Sampling Frequency | 1–9999 cycles/min (adjustable) |
| Test Aerosol Concentration | 20–30 mg/m³ |
| Count Median Diameter (CMD) | NaCl aerosol (0.075 ± 0.02) µm |
| Geometric Standard Deviation (GSD) | NaCl ≤ 1.86 |
| Dynamic Concentration Range | 0.001–100 mg/m³ (±1% accuracy) |
| Differential Pressure Sensor Range | 0–500 Pa |
| Dimensions | 460 mm × 525 mm × 1430 mm |
| Power Supply | AC 220 V, 50 Hz |
| Environmental Control | Integrated temperature & humidity sensor (operating range: 25 °C ± 5 °C, 30 %RH ± 10 %RH) |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | GB-KF30010AB |
| Filtration Efficiency Range | 0–99.999% |
| Flow Rate Range | 20–100 L/min |
| Pressure Drop Range | 0–1000 Pa |
| Test Particle Sizes | 0.3 µm, 0.5 µm, 5.0 µm |
| Aerosol Sources | DEHS (oil-based) and 2% NaCl (salt-based) |
| Standard Test Area | 100 cm² |
| Power Consumption | <1500 W |
| Dimensions | 130 × 75 × 157 cm |
| Weight | 250 kg |
| Power Supply | AC 220 V, 50 Hz |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer | GBPI Packaging Instruments Co., Ltd. |
| Model | GB-KF30010AD |
| Compliance Standards | GB/T 32610–2016, GB 2626–2006, GB 19082–2009, GB 19083–2010, GB 24539–2009, YY 0469–2011, YY/T 0969–2013, EN 1822–3:1998 (principle), ASTM F2299/F2101 (referenced methodology) |
| Filtration Efficiency Range | 0–99.999% |
| Flow Rate Control | 20–100 L/min (±1.5% FS) |
| Pressure Drop Measurement Range | 0–1000 Pa (±1.0% FS) |
| Test Aerosol Size Channels | 0.3 µm, 0.5 µm, 5.0 µm |
| Aerosol Sources | DEHS (dioctyl sebacate) and 2% NaCl solution |
| Test Area | 100 cm² (standard, configurable per mask geometry) |
| Power Supply | AC 220 V, 50 Hz |
| Max Power Consumption | <1500 W |
| Dimensions (W×D×H) | 130 × 75 × 157 cm |
| Weight | 250 kg |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GB-KF30010AG |
| Price Range | USD 42,000 – 70,000 |
| Filtration Efficiency Range | 0–99.999% |
| Flow Rate Control Range | 20–100 L/min |
| Pressure Drop Measurement Range | 0–1000 Pa |
| Test Aerosol Particle Sizes | 0.3 µm, 0.5 µm, 5.0 µm |
| Aerosol Sources | DEHS (oil-based) and 2% NaCl (salt-based) |
| Standard Test Area | 100 cm² (customizable per mask geometry) |
| Dimensions | 130 × 75 × 157 cm |
| Weight | 250 kg |
| Power Consumption | <1500 W |
| Power Supply | AC 220 V, 50 Hz |