| Brand | Jiada Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYJ-201SY |
| Detection Limit | 5.00 mg/kg |
| Measurement Range | 0.00–500.00 mg/kg |
| Accuracy | ±5% |
| Compliance | GB/T 2912.1–1998, GB 18401–2001 |
| Analysis Time | ≤15 min per sample |
| Display | Backlit LCD with Chinese interface |
| Control System | Embedded microcontroller |
| Data Functions | Measurement logging, statistical processing, configuration, help, and RS232 communication |
| Sample Prep | Dedicated extraction apparatus + single-use reagent kits |
| Quantitative Output | mg/kg (formaldehyde content in fabric) |
| Brand | Jiada Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (PRC) |
| Model | GDYQ-1000S |
| Function Type | Single-Analyte Dedicated Instrument |
| Sample Specificity | Soy Sauce Only |
| Detection Time | 30 minutes |
| Detection Range | 0.0–2.0 g/100 mL |
| Detection Limit | 0.1 g/100 mL |
| Accuracy | ±2% |
| Display | Backlit LCD with Chinese UI |
| Control System | Embedded MCU with Data Logging, Parameter Configuration, Statistical Processing, and RS232 Communication |
| Sample Prep | Integrated Dedicated Pretreatment Module + Single-Use Reagent Cartridge Kit |
| Brand | Jiada Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | GDYQ-100M (50 Parameters) |
| Price Range | USD 7,000 – 14,000 |
| Function Type | Multi-Analyte (Simultaneous Quantitative Screening) |
| Sample Applicability | Universal for Solid, Semi-Solid & Liquid Food Matrices |
| Optical Wavelength Range | 400 nm – 630 nm |
| Typical Analysis Time per Parameter | 3–10 minutes |
| Brand | Jiada Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | GDYQ-103SC |
| Function Type | Single-Analyte Detection |
| Sample Versatility | Multi-Matrix (Solid & Liquid) |
| Optical Wavelength | 538 nm |
| Detection Limit | 10.0 mg/kg (solid), 1.00 mg/L (liquid) |
| Quantification Range | 0.0–600.0 mg/kg (solid), 0.0–60.0 mg/L (liquid) |
| Accuracy | ±5% |
| Power Supply | AC 220 V ±22 V, 50 Hz ±1 Hz |
| Dimensions | 310 × 225 × 125 mm |
| Weight | <1.7 kg |
| Brand | Jiada Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | GDYQ-110S2 |
| Function Type | Multi-analyte (Methanol + Ethanol) |
| Sample Format | Single-sample dedicated format |
| Wavelengths | 412 nm, 595 nm |
| Brand | Jiada Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYQ-110SE2 |
| Function Type | Multi-analyte (POD, TVB-N, pH) |
| Sample Compatibility | Universal for raw meat, poultry, and aquatic products |
| Detection Limits | POD Absorbance ≥0.010 A |
| pH Resolution | 0.1 unit |
| Measurement Ranges | POD: 0.000–2.000 A |
| TVB-N | 0.0–150.0 mg/100g |
| pH | 0.2–14.0 |
| Accuracy | ±10% of full scale (per GB/T 5009.44-2003 validation protocol) |
| Interface | RS-232 & USB 2.0 |
| Data Handling | On-device storage, print output, PC synchronization |
| Brand | Jiada Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYQ-110SF |
| Function Type | Single-Analyte Quantitative Detection |
| Sample Compatibility | Multi-Sample Universal Format |
| Detection Time | 10 minutes |
| Detection Limit | 0.1 mg KOH/g |
| Measurement Range | 0.0–30.0 mg KOH/g |
| Accuracy | ±5% (Relative Standard Deviation) |
| Reference Standard | GB/T 5009.37–2003 |
| Brand | Jiada Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYQ-110SG |
| Function Type | Single-Analyte Quantitative Detection (Fatty Acid Value) |
| Sample Compatibility | Multi-sample Universal (Paddy Rice, Milled Rice, Rice Flour, and Processed Rice Products) |
| Detection Principle | Micro-titration with Standardized KOH Solution |
| Lower Detection Limit | 5.0 mg KOH / 100 g |
| Measurement Range | 0.0–500.0 mg KOH / 100 g |
| Construction | Chemically Resistant Housing & Precision Micro-burette Assembly |
| Regulatory Alignment | Designed for compliance with GB/T 20569–2006 (Chinese National Standard for Fatty Acid Value Determination in Stored Rice) and supports GLP-aligned documentation workflows |
| Brand | Jiada Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYQ-4000S |
| Function Type | Single-Analyte Detection (Iodine) |
| Sample Versatility | Multi-Sample Compatible |
| Detection Limit | 2.0 mg/kg |
| Measurement Range | 0.0–80.0 mg/kg |
| Accuracy | ±2% |
| Analysis Time | ≤3 minutes per sample |
| Display | Backlit LCD with Chinese UI |
| Control System | Embedded MCU with data logging, parameter configuration, statistical processing, and RS232 communication |
| Sample Prep | Dedicated pretreatment kit + single-use reagent cartridges |
| Brand | Jiada Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | GDYQ-501S |
| Function Type | Single-Analyte Quantitative Detection |
| Sample Compatibility | Universal for Food & Biological Matrices |
| Wavelength Range | 400–700 nm |
| Throughput | 96-well plate in 5 seconds |
| Optical Resolution | 0.001 A (display), 0.0001 A (internal calculation) |
| Photometric Repeatability | ≤ ±1% |
| Linearity | ±1% (0.000–2.000 A) |
| Absorbance Range | 0.0000–4.0000 A |
| Measurement Modes | Single-, Dual-, and Multi-Wavelength |
| Built-in Oscillation | Adjustable speed & duration |
| Interface | RS232 serial port, parallel port |
| Power Supply | AC 220 V / 110 V ±22 V, 50 Hz / 60 Hz ±1 Hz |
| Brand | Jiada Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYN-1016SD |
| Detection Method | Enzyme Inhibition Assay |
| Measurement Range | 0–100% inhibition rate |
| Number of Channels | 16 |
| Measurement Error | ±5% |
| Limit of Detection (LOD) | 0.01–3.0 mg/kg |
| Light Source | High-brightness LED |
| Wavelength | 405 nm |
| Optical Stability | ±0.005 A/20 min |
| Operating Temperature | 5–40 °C |
| Power Supply | AC 220 V ±10%, 50 Hz ±1 Hz / Built-in Rechargeable Li-ion Battery |
| Data Storage | 32 GB internal + MicroSD expansion |
| Connectivity | Micro-USB, Micro-HDMI, Wi-Fi, GPRS/EDGE |
| OS | Embedded Windows-based interface |
| Brand | Jiada Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | GDYN-1024SC |
| Price Range | USD 4,200 – 7,000 (FOB) |
| Detection Method | Enzyme Inhibition Assay |
| Measurement Range | 0–100% inhibition |
| Number of Channels | 24 |
| Measurement Error | ±6% |
| Limit of Detection (LOD) | 0.01–3.0 mg/kg |
| Light Source | Silicon Photodiode |
| Wavelength | 405 nm |
| Absorbance Range | 0.000–2.000 Abs |
| Inhibition Rate Range | 0–100% |
| Precision | ±6% |
| Detection Limit | 0.01–3.0 mg/kg |
| Brand | Jiada Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | GDYN-1096SC |
| Detection Method | Enzyme Inhibition Assay |
| Number of Channels | 96 |
| Limit of Detection (LOD) | 0.01–3.0 mg/kg |
| Inhibition Range | 0–100% |
| Inhibition Accuracy | ±6% (at 50% inhibition) |
| Throughput | Up to 192 samples per hour |
| Data Storage Capacity | 1024 records |
| Interface | RS-232 / USB |
| Display | Full-Text LCD (Chinese) |
| Reagent Compatibility | Imported cholinesterase-based reagents (500-test kit included) |
| Optical Architecture | Solid-state array light source and detector per channel |
| Expected Service Life | >10 years |
| Brand | Jiada Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYN-110SA |
| Detection Method | Enzyme Inhibition Assay |
| Number of Channels | 10 |
| Temperature Display Accuracy | ±0.5 °C |
| Colorimetric Timing Precision | ±1 s |
| Standard Reaction Time | 3 min |
| Input Voltage | 100–240 V AC |
| Rechargeable Battery Runtime | 100–150 min |
| Adjustable Incubation Time Range | 1–99 min |
| Operating Environment | Indoor & Vehicle-Mounted |
| Operating Temperature Range | 0–40 °C |
| Brand | Jiada Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYN-501MA |
| Detection Method | Thin-layer Chromatography (TLC) |
| Measurement Range | Organophosphates: 0.03–20 mg/kg |
| Carbamates | 0.03–20 mg/kg |
| Pyrethroids | 0.10–30 mg/kg |
| Organochlorines | 0.10–10 mg/kg |
| Light Source | 254 nm UV lamp |
| Warm-up Time | ≤5 min |
| Irradiance | ≥1000 µW/cm² |
| Lamp Lifetime | ≥12,000 h |
| Wavelength Repeatability | ±1 nm |
| Wavelength Accuracy | ±5 nm |
| Filter Transmittance | ≥95% |
| Spot Spacing | 5–30 mm |
| Sample Volume | 2.5–15 µL |
| Spot Diameter | ≤2.0 mm |
| Operating Temperature | 5–40 °C |
| Relative Humidity | 10–85% RH |
| Data Interface | USB 2.0 |
| Power Supply | 220 V ±22 V, 50 Hz ±1 Hz |
| Software Platform | Windows XP |
| Detection Modes | Transmission & Reflectance |
| Dimensions | 580 × 360 × 260 mm |
| Weight | 15.8 kg |
| Brand | Jiada Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYQ-1100M |
| Price Range | USD 1,400 – 7,200 |
| Detection Parameters | Moisture (0.0–27.0%), Fructose + Glucose (0.0–76.0%), Sucrose (0.0–12.0%), Acidity (0.0–100.0 mL/kg), Hydroxymethylfurfural (HMF) (0.0–100.0 mg/kg), Diastase Activity (0.0–25.0 mL/(g·h)) |
| LOD | Moisture: 12.0%, Fructose + Glucose: 13.0%, Sucrose: 3.0%, Acidity: 4.0 mL/kg, HMF: 1.0 mg/kg, Diastase Activity: 1.0 mL/(g·h) |
| Accuracy | ±2% |
| Interface | RS-232 / USB |
| Display | Backlit LCD with Chinese UI |
| Data Handling | Onboard storage, PC connectivity, statistical analysis |
| Brand | Jiada Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | GDYQ-110SU |
| Function Type | Single-Analyte Quantitative Detection |
| Sample Type | Dedicated to Wheat Flour Matrix |
| Wavelength | 538 nm |
| Detection Limit | 5.0 mg/kg |
| Measurement Range | 5.0–100.0 mg/kg |
| Accuracy | ±5% |
| Light Source | High-Brightness LED |
| Power Supply | DC 9 V |
| Dimensions | 190 × 110 × 95 mm |
| Weight | 0.4 kg |
| Included | Sample Pretreatment Kit (1 set), Reagent Kit (50 assays) |
| Brand | Jiada Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | GDYQ-1400S |
| Function Type | Single-Analyte Immunoassay Platform |
| Sample Versatility | Multi-sample Compatible (Liquid Food Matrices) |
| Wavelength Range | 400–700 nm |
| Throughput | 96-well plate in 5 seconds |
| Optical Resolution | 0.001 A (display), 0.0001 A (internal calculation) |
| Photometric Linearity | ±1% (0.000–2.000 A) |
| Absorbance Measurement Range | 0.0000–4.0000 A |
| Plate Formats | Standard 96-well and 48-well microplates |
| Filter Positions | Fixed 405 nm, 450 nm, 492 nm, 630 nm + 4 configurable slots |
| Detection Methodology | Single-, Dual-, and Multi-wavelength ELISA photometry |
| Data Processing Algorithms | Linear, Semi-log, 4PL, 5PL, Polynomial, Parabolic, Spline Curve Fitting |
| Plate Shaking | Adjustable speed and duration |
| Interface | RS232 serial port, parallel port |
| Power Supply | AC 220 V / 110 V ±22 V, 50 Hz / 60 Hz ±1 Hz |
| Brand | Jiada Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYQ-2000S |
| Detection Limit | 0.3 mmol/kg |
| Measurement Range | 0.0–11.0 mmol/kg |
| Accuracy | ±2% |
| Analysis Time | ≤5 min per sample |
| Display | Backlit LCD with Chinese UI |
| Control System | Embedded MCU with data logging, USB connectivity, and on-board statistical processing |
| Sample Prep | Integrated proprietary pre-treatment module + single-use reagent kits |
| Compliance | Modified GB/T 5009.37–2003 method |
| Brand | Jiada Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYQ-210SD |
| Function Type | Single-Analyte Detection System |
| Sample Compatibility | Multi-Matrix Food Samples |
| Detection Limit | 50.0 mg/kg |
| Quantification Range | 0.0–2000.0 mg/kg |
| Measurement Accuracy | ±5% (relative standard deviation under controlled conditions) |
| Control System | Embedded MCU-based platform |
| Data Interface | RS-232 and USB 2.0 |
| Display | Backlit LCD with Chinese UI |
| Portability | Handheld form factor, <1.2 kg |
| Brand | Jiada Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Manufacture | Domestic (China) |
| Model | GDYQ-210SP |
| Price Range | USD 2,800–4,200 (FOB) |
| Functionality | Single-Analyte Quantitative Detection |
| Sample Compatibility | Multi-Sample Universal Design |
| Detection Range | 10.0%–50.0% (adulteration level) |
| Limit of Detection | 10.0% (adulteration level) |
| Power Supply | 220 V ±20 V, 50–60 Hz |
| Operating Ambient Temperature | 10–30 °C |
| Brand | Jiada Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | GDYQ-500M |
| Price Range | USD 4,200 – 7,000 |
| Function Type | Multi-analyte Detection Platform |
| Sample Compatibility | Universal for Solid, Semi-solid, and Liquid Food Matrices |
| Detection Principles | UV-Vis Absorbance (Transmission/Reflection), Fluorescence Spectrometry |
| Wavelength Accuracy | ±5 nm |
| Wavelength Repeatability | ±1 nm |
| Detection Modes | Transmission, Reflectance, Fluorescence |
| Quantification Method | External Standard Calibration |
| Regulatory Compliance | GB/T 5009.28–2003, GB/T 5009.29–2003, GB/T 5009.35–2003, GB/T 5009.141–2003, GB 2760–2011 |
| Software | Dedicated PC-based Workstation with Chromatogram-like Peak Visualization, Automatic Integration, and Audit-Trail-Ready Data Export |
| Brand | Jiada Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | GDYQ-6000S |
| Function Type | Single-Analyte Quantitative Detection |
| Sample Versatility | Multi-Sample Compatible |
| Optical Detection Wavelength | 400 nm |
| Detection Channels | 1 |
| Lower Detection Limit | 10.0 mg/kg |
| Quantification Range | 0.0–1000.0 mg/kg |
| Measurement Accuracy | ±2% |
| Brand | Jiada Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (PRC) |
| Model | GDYQ-900M |
| Price Range | USD 7,000–14,000 (FOB) |
| Functionality | Multi-analyte (simultaneous detection of >20 food safety parameters) |
| Sample Versatility | Universal for solid, liquid, and semi-solid food matrices |
| Optical Detection Range | 495–530 nm |
| Repeatability | ≤ ±5% CV or ±5 RLUs |
| Detection Channels | 16 independent optical/analytical channels |
| Power Supply | AC/DC dual-mode |
| Display | 10.1" capacitive touchscreen, 1024 × 768 resolution |
| Data Storage | Internal SSD (≥64 GB) |
| Connectivity | Wi-Fi 802.11 b/g/n, Ethernet (RJ45), USB 2.0 × 2 |
| Output | Integrated thermal printer + external printer support via USB/Ethernet |
| Operating System | Windows Embedded Standard 7 |
| Software | Proprietary modular detection platform with remote OTA and local USB firmware update capability |
| Brand | Jiada Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | GDYQ-901SC2 |
| Function Type | Single-Analyte Detection |
| Sample Versatility | Multi-Sample Compatible |
| Optical Wavelength | 538 nm |
| Detection Channels | 1 |
| Detection Limit | 2.0 mg/kg |
| Measurement Range | 0.0–200.0 mg/kg |
| Accuracy | ±2% |
| Regulatory Method | Modified GB/T 5009.33–2003 |
| Brand | Jiada Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYQ-RS1101 |
| Function Type | Single-parameter Moisture Determination |
| Sample Scope | Multi-sample Universal (Fresh Mammalian & Poultry Muscle Tissue) |
| Measurement Range | 65–85% w/w |
| Sampling Time | <1 s per acquisition |
| Output Interval | One result per 10 acquisitions or per single acquisition (configurable) |
| Accuracy (70–80% range) | ±1.0% w/w |
| Repeatability (70–80% range) | ≤0.5% w/w |
| Operating Temperature | 0–40 °C |
| Power Alert | Yes |
| Auto-shutdown | Yes |
| Data Storage | Onboard memory with total count display and recall |
| PC Connectivity | USB interface for data export and post-processing |
| Brand | JIAHANG |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | AIpol-JHD50 |
| Price | Upon Request |
| Temperature Range | Ambient to 400 °C |
| Temperature Resolution | 0.01 °C |
| Heating Rate | 0.1–20 °C/min (200-step continuous adjustment) |
| Accuracy | ±0.2 °C (<250 °C), ±0.4 °C (>250 °C) |
| Repeatability | ±0.1 °C at 0.1 °C/min |
| Sample Capacity | 2 parallel channels (2 drop point cups: 2.8 mm orifice |
| 2 softening point cups | 6.35 mm orifice) |
| Optical Magnification | Standard 9×, adjustable |
| Display | 10.4″ FTF color touchscreen |
| Data Storage | 64 GB internal |
| Method Library | 600 preloaded, user-lockable |
| User Management | 4-tier permission control |
| Audit Trail | Compliant with FDA 21 CFR Part 11 |
| Electronic Signature | Enabled |
| Data Export Formats | PDF, Excel |
| Connectivity | USB, RS232, SD card, Wi-Fi, RJ45, U-disk interface |
| Barcode Scanner Support | Yes |
| Power Supply | 110–230 V AC, 50/60 Hz, 120 W |
| Dimensions (W×D×H) | 430 × 320 × 370 mm |
| Net Weight | 6.5 kg |
| Brand | JIAHANG |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HSY-3536D |
| Detection Method | Cleveland Open-Cup (COC) |
| Operation Mode | Fully Automatic |
| Applicable Standard | GB/T 3536–2008 |
| Repeatability | ≤8 °C (flash point and fire point) |
| Ignition Method | Electronic spark ignition |
| Temperature Range | Ambient to 400 °C |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Display | 8-inch industrial true-color touchscreen (Windows CE OS, bilingual Chinese/English interface) |
| Temperature Sensor | Imported German PT1000 (resolution: 0.1 °C) |
| Microcontroller | Renesas MCU |
| Data Storage | 120 test records onboard |
| Safety Features | Auto-shutdown on overtemperature, flame-quenching lid for fire point, real-time millisecond-level flash detection |
| Environmental Operating Conditions | 10–40 °C, RH ≤80% |
| Power Consumption | ≤500 W |
| Dimensions (lowered/lifted) | 520 × 360 × 310 / 420 mm (L×W×H) |
| Brand | JIAHANG |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | JH-D2102 |
| Price Range | USD 1,400 – 2,800 |
| Measurement Principle | Ring-and-Ball Method (ASTM D36 / ISO 4625 / ChP 2020 General Chapter 2102 / USP <741>) |
| Temperature Range | 5–80 °C (water bath) / 32–162 °C (glycerol bath) |
| Temp. Resolution | 0.1 °C |
| Heating Rate | 1.0–1.5 °C/min (linear ramp, PID-controlled) |
| Sample Capacity | 2 specimens simultaneously |
| Stirring | Adjustable magnetic stirrer (infinitely variable speed) |
| Detection Method | Dual-channel laser beam interruption detection |
| Data Storage | 200 test records (CSV export via USB) |
| Compliance | Fully compliant with ChP 2020 Edition General Chapter 2102, supports audit trail per FDA 21 CFR Part 11 requirements |
| Interface | RS-485 (Modbus RTU) |
| Dimensions (L×W×H) | 390 × 300 × 575 mm |
| Weight | 12.0 kg |
| Power Supply | 220 ±10% VAC, 50 Hz |
| Max. Power Consumption | ≤800 W |
| Brand | JIAHANG |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | JHD50 |
| Temperature Range | Ambient to 400 °C |
| Temperature Resolution | 0.1 °C |
| Accuracy | ±0.2 °C (≤250 °C), ±0.5 °C (>250 °C) |
| Heating Rate | 0.1–20 °C/min |
| Sample Capacity | 2 samples per run |
| Display | Dual-screen — 5.6″ + 4.3″ color TFT LCD |
| User Accounts | Up to 15 |
| Predefined Methods | 100 stored protocols |
| Data Interfaces | USB, RS-232, Ethernet |
| GLP Compliance | Yes |
| Power Supply | 220 V, 50 Hz, 120 W |
| Standards Compliance | ASTM D3204, D3461, D3104, D3954, D6090 |
| ISO 2176 | 1972, 4625:2 |