BrandScinco
OriginUSA
ModelSTA N-650/1000/1200/1500
Temperature Range–125 to 650 °C, RT to 1000/1200/1500 °C
Heating/Cooling Rate0.1–100 °C/min (N-650), 0.1–40 °C/min (N-1000/N-1200/N-1500)
Maximum Sample Mass400 mg
Temperature Accuracy±0.1 °C
Mass Accuracy±0.1 µg
Gas PurgeIntegrated automatic gas switching (optional)
Furnace DesignVertical micro-balance architecture with water-cooled furnace
CompatibilityFT-IR, Q-MS, and other evolved gas analysis (EGA) systems
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKRUESS
OriginGermany
ModelM3000 & M5000
Temperature Range25–400 °C
Heating Rate4 min to 300 °C, 7.5 min to 400 °C
Temperature Repeatability±0.2 °C
Temperature Accuracy±0.3 °C (25–200 °C), ±0.5 °C (200–400 °C)
Capillary Dimensions1.4 mm OD
Sample Capacity1 capillary per measurement
Temperature Resolution0.1 °C
Optical Magnification10×
CoolingIntegrated fan-assisted rapid cooling
DisplayBacklit LCD with real-time temperature and status
InterfaceRS-232
Power Supply90–264 V AC, 40 W
Ingress ProtectionIP20
Weight2.3 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandScinco
OriginUSA
ModelTGA N-1000 / TGA N-1250 / TGA N-1500
Temperature RangeAmbient to 1000°C / 1250°C / 1500°C
Balance Sensitivity0.1 µg
Maximum Sample Mass400 mg
Heating Rate0.1–300 °C/min (N-1000/N-1250) or 0.1–60 °C/min (N-1500)
Cooling MethodWater-cooled furnace housing
Gas Control4-channel automated gas switching valve
Simultaneous Analysis CompatibilityFT-IR and Quadrupole Mass Spectrometry (EGA-ready)
Sample CapacitySingle-sample vertical configuration
ComplianceDesigned for GLP/GMP environments with audit-trail-capable software
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSCINCO
OriginUSA
ModelDSC N-650
Sample CapacitySingle
Instrument TypeDifferential Scanning Calorimeter (DSC)
Temperature Range−150 °C to 725 °C
Temperature Accuracy±0.1 °C
Temperature Precision±0.1 °C
Thermocouple TypeType K
Heating/Cooling Rate0.1–200 °C/min
Baseline StabilityHigh
Heat Flow Sensor Noise LevelLow
Cooling MethodOptional Water Cooling
Sample Pan EnclosureSealed
Temperature ControlDual-PID
Added to wishlistRemoved from wishlist 0
Add to compare
BrandConcept
OriginUnited Kingdom
ModelMicroscale Combustion Calorimeter
StandardASTM D7309
Heating Rate Range0.2–5 K/s (±5% accuracy)
Temperature Range0–1000 °C
Detection Limit5 mW
Repeatability±2% (for 5 mg sample)
Oxygen MeasurementParamagnetic sensor, 0–100% O₂, accuracy ±0.1%
Gas Flow ControlHigh-precision mass flow controllers for N₂ (80 cm³/min, max 100 cm³/min) and O₂ (20 cm³/min, max 50 cm³/min)
Sample Mass Range0.5–10 mg
Furnace10 mm alumina tube with dual Kanthal heating elements
Power Supply230 V AC, 50 Hz, 10 A
Dimensions (W×H×D)600 mm × 1025 mm × 500 mm
Weight42 kg
Operating Ambient10–35 °C