Empowering Scientific Discovery

Kohe Instruments (Shanghai) Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDistek
OriginUSA
ModelSensIR 3200
Disintegration Vessel Capacity1 L (2, 4 or 6 vessels)
Temperature Control Range20°C to 65°C
Temperature Accuracy±1°C
Temperature Resolution0.1°C
Heating Rate~2°C/min
Timer Range10 s to 99 h 59 min 59 s
Timer Resolution1 s
Basket Stroke Amplitude5.5 cm
Basket Cycle Frequency23–35 cycles/min
Frequency Accuracy±1 cycle/min
Drive MotorBrushless DC Motor
Display5.7" Color Touchscreen
User ManagementUp to 50 users with role-based permissions
InterfacesUSB, LAN, RS-232, RS-485
Dimensions (2-unit)36 cm × 72 cm × 48 cm
Weight (2-unit)20 kg
Power Supply115 V ±15 V / 230 V ±15 V, 50/60 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDistek
OriginUSA
ModelEZFILL 4500
Dispensing Volume250–1000 mL
Dispensing Accuracy±1% of set volume or ±5 mL
Heating RangeAmbient to 45°C
Temperature Accuracy±2°C
Dissolved Oxygen Level≤3.0 ppm (typical), ≤5.0 ppm (max)
Integrated Filter25 mm diameter
Surface Active Agent Toleranceup to 2% (w/v)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDistek
OriginUSA
ModelVIP 4400
Heating CapabilityExternal heater connection (25–60 °C)
Cycle Time per Vessel30–45 s
Total Batch Cleaning Time~3–4 min (mode-dependent)
Cleaning Modes3 selectable intensity levels (gentle to aggressive)
Noise LevelLow
Drain ControlAutomatic adjustment
Core TechnologyPatented cyclonic rinse mechanism
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDistek
OriginUSA
Model2500 Select
Instrument TypeOffline Dissolution Tester
Vessel Positions6, 7, or 8
Temperature Range20–99 °C
Temperature Accuracy±0.25 °C
Temperature Resolution0.01 °C
Rotational Speed Range30–300 rpm
Speed Resolution0.1 rpm
Speed Accuracy±0.5 rpm
Paddle Wobble Tolerance0.5 mm
Basket Wobble Tolerance1.0 mm
Heating Rate2 °C/min
Vessel Capacity500–1000 mL
Block Volume Equivalent17.5 L (dry-block thermal mass)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDistek
OriginUSA
Model2500
Instrument TypeOffline Dissolution Tester
Vessel Configuration6, 7, or 8 vessels
Vessel Volume Range100–4000 mL
Temperature RangeAmbient to 65 °C
Temperature Accuracy±0.2 °C
Temperature Resolution0.1 °C
Bath Volume18 L
Rotational Speed Range25–300 RPM
Speed Resolution0.1 RPM
Speed Accuracy±0.2 RPM
Paddle Wobble< 0.010″ (0.254 mm)
Basket Wobble< 0.010″ (0.254 mm)
Bath Temperature Control SystemMicroprocessor-Controlled Self-Priming TCS
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDistek
OriginUSA
ModelEclipse 5300
Instrument TypeOnline Sampling System
Sample Vessels6–8 vessels
Temperature Range20–65 °C
Temperature Accuracy±0.1 °C
Rotational Speed Range30–300 RPM
Paddle Wobble≤0.01 inch
Basket Wobble≤0.03 inch
Bath Temperature Control Range20–65 °C
Bath Temperature Resolution0.25 °C
Bath Volume18 L
Show next