Empowering Scientific Discovery

Kohe Instruments (Shanghai) Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandConcept
OriginUnited Kingdom
ModelTemperature Index Module
Electrical Supply230 V AC, 50 Hz / 115 V AC, 60 Hz
Operating Temperature Range10–35 °C
Test Temperature RangeAmbient to 400 °C
Gas Flow Rate0–20 nl/min
Minimum Gas Supply Pressure2.6 bar (38 psi) for O₂ and N₂
Minimum Gas Supply Flow25 nl/min
Oxygen Analyzer Range0–100% O₂
Oxygen Measurement Repeatability±0.1% O₂ (typ.)
Oxygen Linearity±0.1% O₂ (typ.)
Dimensions450 mm (W) × 800 mm (H) × 450 mm (D)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandScinco
OriginUSA
ModelSTA N-650/1000/1200/1500
Temperature Range–125 to 650 °C, RT to 1000/1200/1500 °C
Heating/Cooling Rate0.1–100 °C/min (N-650), 0.1–40 °C/min (N-1000/N-1200/N-1500)
Maximum Sample Mass400 mg
Temperature Accuracy±0.1 °C
Mass Accuracy±0.1 µg
Gas PurgeIntegrated automatic gas switching (optional)
Furnace DesignVertical micro-balance architecture with water-cooled furnace
CompatibilityFT-IR, Q-MS, and other evolved gas analysis (EGA) systems
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKRUESS
OriginGermany
ModelM3000 & M5000
Temperature Range25–400 °C
Heating Rate4 min to 300 °C, 7.5 min to 400 °C
Temperature Repeatability±0.2 °C
Temperature Accuracy±0.3 °C (25–200 °C), ±0.5 °C (200–400 °C)
Capillary Dimensions1.4 mm OD
Sample Capacity1 capillary per measurement
Temperature Resolution0.1 °C
Optical Magnification10×
CoolingIntegrated fan-assisted rapid cooling
DisplayBacklit LCD with real-time temperature and status
InterfaceRS-232
Power Supply90–264 V AC, 40 W
Ingress ProtectionIP20
Weight2.3 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandConcept
OriginUnited Kingdom
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelFAA Radiant Panel Chamber (Electric)
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKRUESS
OriginGermany
ModelDS7800
Instrument TypeLaboratory Benchtop Oscillating U-Tube Densimeter
Sample TypeLiquid
Density Range0.0000–1.9999 g/cm³
Density Accuracy±0.0001 g/cm³
Density Resolution0.0001 g/cm³
Repeatability±0.0001 g/cm³
Temperature Control Range10–40 °C
Temperature Stability±0.02 °C
Minimum Sample Volume0.9 mL
Measurement Time~5 min
Calibration StandardsDry air and distilled water
ComplianceASTM D4052, ASTM D5002, NIST-traceable, GLP/GMP-ready
Data StorageSQL database (999 results)
Interface OptionsEthernet, USB 2.0, RS-232
Display5.7″ TFT color LCD (640×480 VGA)
Power Supply90–264 V AC, 50/60 Hz
User ManagementThree-level password protection
Language Support6 languages
LIMS CompatibilityYes
Added to wishlistRemoved from wishlist 0
Add to compare
BrandConcept
OriginUnited Kingdom
ModelUL94 FLAMMABILITY CHAMBER
Chamber Volume>1 m³
Noise Level62.5 dB(A)
Burner Angle Adjustment0°, 20°, 45°
Compliant StandardsUL 94, IEC 60695-11-10/20, ASTM D635, ISO 1210, ISO 9772, BS 2782 Method 140A/140B
Gas Supply98% methane
Operating Ambient Temperature10–35 °C
Electrical Supply115–230 V AC, single-phase
Added to wishlistRemoved from wishlist 0
Add to compare
BrandScinco
OriginUSA
ModelTGA N-1000 / TGA N-1250 / TGA N-1500
Temperature RangeAmbient to 1000°C / 1250°C / 1500°C
Balance Sensitivity0.1 µg
Maximum Sample Mass400 mg
Heating Rate0.1–300 °C/min (N-1000/N-1250) or 0.1–60 °C/min (N-1500)
Cooling MethodWater-cooled furnace housing
Gas Control4-channel automated gas switching valve
Simultaneous Analysis CompatibilityFT-IR and Quadrupole Mass Spectrometry (EGA-ready)
Sample CapacitySingle-sample vertical configuration
ComplianceDesigned for GLP/GMP environments with audit-trail-capable software
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSCINCO
OriginUSA
ModelDSC N-650
Sample CapacitySingle
Instrument TypeDifferential Scanning Calorimeter (DSC)
Temperature Range−150 °C to 725 °C
Temperature Accuracy±0.1 °C
Temperature Precision±0.1 °C
Thermocouple TypeType K
Heating/Cooling Rate0.1–200 °C/min
Baseline StabilityHigh
Heat Flow Sensor Noise LevelLow
Cooling MethodOptional Water Cooling
Sample Pan EnclosureSealed
Temperature ControlDual-PID
Added to wishlistRemoved from wishlist 0
Add to compare
BrandConcept
OriginUnited Kingdom
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelNBS SMOKE CHAMBER
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandConcept
OriginUnited Kingdom
ModelMicroscale Combustion Calorimeter
StandardASTM D7309
Heating Rate Range0.2–5 K/s (±5% accuracy)
Temperature Range0–1000 °C
Detection Limit5 mW
Repeatability±2% (for 5 mg sample)
Oxygen MeasurementParamagnetic sensor, 0–100% O₂, accuracy ±0.1%
Gas Flow ControlHigh-precision mass flow controllers for N₂ (80 cm³/min, max 100 cm³/min) and O₂ (20 cm³/min, max 50 cm³/min)
Sample Mass Range0.5–10 mg
Furnace10 mm alumina tube with dual Kanthal heating elements
Power Supply230 V AC, 50 Hz, 10 A
Dimensions (W×H×D)600 mm × 1025 mm × 500 mm
Weight42 kg
Operating Ambient10–35 °C
Added to wishlistRemoved from wishlist 0
Add to compare
BrandConcept
OriginUnited Kingdom
ModelCone Calorimeter
Standards ComplianceISO 5660-1, ASTM E1354, ASTM E1550, ASTM E1740, ASTM D5485, ASTM D6113, BS 476-15, NFPA 271, NFPA 264, CAN/ULC-S135
Heat Flux Range0–75 kW/m² (CNC-machined conical heater, uniform irradiance)
Mass Loss Resolution0.01 g (high-precision load cell)
Oxygen AnalyzerParamagnetic, 0–25% v/v range
CO₂ AnalyzerNDIR, dual-range (0–10% and 0–1.0% v/v)
Smoke MeasurementHeNe laser-based extinction system with auto-calibration
Data Acquisition Rate≥4 Hz (minimum scan interval: 250 ms)
Exhaust SystemStainless steel ducting, conical hood, annular sampling probe, and variable-speed exhaust blower
IgnitionAutomated spark igniter with software-actuated shutter
Operating Environment10–35 °C ambient temperature
Electrical Supply230 V / 50 Hz / 32 A or 115 V / 60 Hz / 50 A single-phase
Dimensions (H×W×D)2420 × 2140 × 700 mm
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0