- All
- Favorite
- Popular
- Most rated
| Brand | Concept |
|---|---|
| Origin | United Kingdom |
| Model | Temperature Index Module |
| Electrical Supply | 230 V AC, 50 Hz / 115 V AC, 60 Hz |
| Operating Temperature Range | 10–35 °C |
| Test Temperature Range | Ambient to 400 °C |
| Gas Flow Rate | 0–20 nl/min |
| Minimum Gas Supply Pressure | 2.6 bar (38 psi) for O₂ and N₂ |
| Minimum Gas Supply Flow | 25 nl/min |
| Oxygen Analyzer Range | 0–100% O₂ |
| Oxygen Measurement Repeatability | ±0.1% O₂ (typ.) |
| Oxygen Linearity | ±0.1% O₂ (typ.) |
| Dimensions | 450 mm (W) × 800 mm (H) × 450 mm (D) |
| Brand | Scinco |
|---|---|
| Origin | USA |
| Model | STA N-650/1000/1200/1500 |
| Temperature Range | –125 to 650 °C, RT to 1000/1200/1500 °C |
| Heating/Cooling Rate | 0.1–100 °C/min (N-650), 0.1–40 °C/min (N-1000/N-1200/N-1500) |
| Maximum Sample Mass | 400 mg |
| Temperature Accuracy | ±0.1 °C |
| Mass Accuracy | ±0.1 µg |
| Gas Purge | Integrated automatic gas switching (optional) |
| Furnace Design | Vertical micro-balance architecture with water-cooled furnace |
| Compatibility | FT-IR, Q-MS, and other evolved gas analysis (EGA) systems |
| Brand | KRUESS |
|---|---|
| Origin | Germany |
| Model | M3000 & M5000 |
| Temperature Range | 25–400 °C |
| Heating Rate | 4 min to 300 °C, 7.5 min to 400 °C |
| Temperature Repeatability | ±0.2 °C |
| Temperature Accuracy | ±0.3 °C (25–200 °C), ±0.5 °C (200–400 °C) |
| Capillary Dimensions | 1.4 mm OD |
| Sample Capacity | 1 capillary per measurement |
| Temperature Resolution | 0.1 °C |
| Optical Magnification | 10× |
| Cooling | Integrated fan-assisted rapid cooling |
| Display | Backlit LCD with real-time temperature and status |
| Interface | RS-232 |
| Power Supply | 90–264 V AC, 40 W |
| Ingress Protection | IP20 |
| Weight | 2.3 kg |
| Brand | Concept |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FAA Radiant Panel Chamber (Electric) |
| Pricing | Available Upon Request |
| Brand | KRUESS |
|---|---|
| Origin | Germany |
| Model | DS7800 |
| Instrument Type | Laboratory Benchtop Oscillating U-Tube Densimeter |
| Sample Type | Liquid |
| Density Range | 0.0000–1.9999 g/cm³ |
| Density Accuracy | ±0.0001 g/cm³ |
| Density Resolution | 0.0001 g/cm³ |
| Repeatability | ±0.0001 g/cm³ |
| Temperature Control Range | 10–40 °C |
| Temperature Stability | ±0.02 °C |
| Minimum Sample Volume | 0.9 mL |
| Measurement Time | ~5 min |
| Calibration Standards | Dry air and distilled water |
| Compliance | ASTM D4052, ASTM D5002, NIST-traceable, GLP/GMP-ready |
| Data Storage | SQL database (999 results) |
| Interface Options | Ethernet, USB 2.0, RS-232 |
| Display | 5.7″ TFT color LCD (640×480 VGA) |
| Power Supply | 90–264 V AC, 50/60 Hz |
| User Management | Three-level password protection |
| Language Support | 6 languages |
| LIMS Compatibility | Yes |
| Brand | Concept |
|---|---|
| Origin | United Kingdom |
| Model | UL94 FLAMMABILITY CHAMBER |
| Chamber Volume | >1 m³ |
| Noise Level | 62.5 dB(A) |
| Burner Angle Adjustment | 0°, 20°, 45° |
| Compliant Standards | UL 94, IEC 60695-11-10/20, ASTM D635, ISO 1210, ISO 9772, BS 2782 Method 140A/140B |
| Gas Supply | 98% methane |
| Operating Ambient Temperature | 10–35 °C |
| Electrical Supply | 115–230 V AC, single-phase |
| Brand | Scinco |
|---|---|
| Origin | USA |
| Model | TGA N-1000 / TGA N-1250 / TGA N-1500 |
| Temperature Range | Ambient to 1000°C / 1250°C / 1500°C |
| Balance Sensitivity | 0.1 µg |
| Maximum Sample Mass | 400 mg |
| Heating Rate | 0.1–300 °C/min (N-1000/N-1250) or 0.1–60 °C/min (N-1500) |
| Cooling Method | Water-cooled furnace housing |
| Gas Control | 4-channel automated gas switching valve |
| Simultaneous Analysis Compatibility | FT-IR and Quadrupole Mass Spectrometry (EGA-ready) |
| Sample Capacity | Single-sample vertical configuration |
| Compliance | Designed for GLP/GMP environments with audit-trail-capable software |
| Brand | SCINCO |
|---|---|
| Origin | USA |
| Model | DSC N-650 |
| Sample Capacity | Single |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | −150 °C to 725 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Precision | ±0.1 °C |
| Thermocouple Type | Type K |
| Heating/Cooling Rate | 0.1–200 °C/min |
| Baseline Stability | High |
| Heat Flow Sensor Noise Level | Low |
| Cooling Method | Optional Water Cooling |
| Sample Pan Enclosure | Sealed |
| Temperature Control | Dual-PID |
| Brand | Concept |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NBS SMOKE CHAMBER |
| Pricing | Upon Request |
| Brand | Concept |
|---|---|
| Origin | United Kingdom |
| Model | Microscale Combustion Calorimeter |
| Standard | ASTM D7309 |
| Heating Rate Range | 0.2–5 K/s (±5% accuracy) |
| Temperature Range | 0–1000 °C |
| Detection Limit | 5 mW |
| Repeatability | ±2% (for 5 mg sample) |
| Oxygen Measurement | Paramagnetic sensor, 0–100% O₂, accuracy ±0.1% |
| Gas Flow Control | High-precision mass flow controllers for N₂ (80 cm³/min, max 100 cm³/min) and O₂ (20 cm³/min, max 50 cm³/min) |
| Sample Mass Range | 0.5–10 mg |
| Furnace | 10 mm alumina tube with dual Kanthal heating elements |
| Power Supply | 230 V AC, 50 Hz, 10 A |
| Dimensions (W×H×D) | 600 mm × 1025 mm × 500 mm |
| Weight | 42 kg |
| Operating Ambient | 10–35 °C |
| Brand | Concept |
|---|---|
| Origin | United Kingdom |
| Model | Cone Calorimeter |
| Standards Compliance | ISO 5660-1, ASTM E1354, ASTM E1550, ASTM E1740, ASTM D5485, ASTM D6113, BS 476-15, NFPA 271, NFPA 264, CAN/ULC-S135 |
| Heat Flux Range | 0–75 kW/m² (CNC-machined conical heater, uniform irradiance) |
| Mass Loss Resolution | 0.01 g (high-precision load cell) |
| Oxygen Analyzer | Paramagnetic, 0–25% v/v range |
| CO₂ Analyzer | NDIR, dual-range (0–10% and 0–1.0% v/v) |
| Smoke Measurement | HeNe laser-based extinction system with auto-calibration |
| Data Acquisition Rate | ≥4 Hz (minimum scan interval: 250 ms) |
| Exhaust System | Stainless steel ducting, conical hood, annular sampling probe, and variable-speed exhaust blower |
| Ignition | Automated spark igniter with software-actuated shutter |
| Operating Environment | 10–35 °C ambient temperature |
| Electrical Supply | 230 V / 50 Hz / 32 A or 115 V / 60 Hz / 50 A single-phase |
| Dimensions (H×W×D) | 2420 × 2140 × 700 mm |
Show next