| Brand | INFORS |
|---|---|
| Origin | Switzerland |
| Model | Multitron Cell |
| Instrument Type | Air-jacketed incubated shaker |
| Oscillation Frequency | 20–400 rpm |
| Adjustable Amplitude | 12.5, 19, 25, 50 mm |
| Temperature Range | RT−15 °C to 65 °C (with optional refrigeration unit) |
| Stackable Layers | Up to 3 independent decks |
| Maximum Load per Deck | 55 kg |
| Chamber Volume | 250 L (single), 750 L (triple-stack) |
| Temperature Uniformity | ±0.2 °C |
| Temperature Stability | ±0.1 °C |
| Control Options | CO₂ (0–20 %, IR sensor), Humidity (20–85 % RH), LED Illumination (up to 200 µmol·m⁻²·s⁻¹), UV Sterilization (optional), Antimicrobial Coating (optional) |
| Brand | INFORS |
|---|---|
| Origin | Switzerland |
| Model | Multitron Cell |
| Temperature Range | RT+5°C to 65°C (RT−15°C to 65°C with optional side-mounted refrigeration unit) |
| Shaking Speed | 20–400 rpm (up to 1000 rpm at 3 mm amplitude) |
| Amplitude Options | Fixed: 3 / 25 / 50 mm |
| Adjustable | 12.5 / 19 / 25 / 50 mm |
| Temperature Uniformity | ±0.2°C |
| Temperature Stability | ±0.1°C |
| Chamber Volume | 250 L (single unit), 750 L (triple-stack configuration) |
| Max Load Capacity | 55 kg per tray (165 kg total for triple stack) |
| Humidity Control Range | 20–85% RH (±1% RH accuracy) |
| CO₂ Control Range | 0.1–20% (±1% FS, IR sensor, PID-controlled) |
| Illumination | LED light kit up to 200 µmol·m⁻²·s⁻¹ |
| Power Input | 230 V, 50/60 Hz |
| Safety Compliance | CE, IEC 61010-1, IEC 61326-1 |
| Brand | INFORS |
|---|---|
| Origin | Switzerland |
| Model | Multitron Standard |
| Oscillation Frequency Range | 20–400 rpm |
| Temperature Range | +5 to 60 °C |
| Temperature Stability | ±0.1 °C |
| Temperature Uniformity | ±0.2 °C |
| Chamber Volume | 240 L |
| External Dimensions (Single Unit) | 1070 × 860 × 550 mm |
| Max Load Capacity | 48 × 250 mL flasks or 6 × 5000 mL vessels |
| Stackable Configuration | Up to 3 units (Total Height with Base: 1710 mm) |
| Drive System | Brushless DC Magnetic Drive |
| Door Load Capacity | >35 kg |
| IP Rating | IPX1 (externally protected electronics, washable chamber interior) |
| Control Interface | Integrated touchscreen with multi-layer independent/centralized operation |
| Brand | INFORS |
|---|---|
| Origin | Switzerland |
| Model | Multitron Standard |
| Shaker Type | Temperature-Controlled Orbital Shaker |
| Timer Range | 9 days and 23 hours |
| Oscillation Speed | 20–400 rpm |
| Orbit Diameter | 25 mm or 50 mm |
| Temperature Range | Ambient +5°C to 60°C (standard) / 4°C to 60°C (low-temperature configuration) |
| Temperature Uniformity | ±0.2°C |
| Temperature Stability | ±0.1°C |
| Tray Dimensions | 850 × 470 mm |
| Chamber Volume | 240 L |
| External Dimensions | 1070 × 860 × 550 mm (single unit) |
| Stackable Units | Up to 3 layers (total height with base: 1070 × 860 × 1710 mm) |
| Load Capacity | 48 × 250 mL flasks or 6 × 5000 mL Fernbach flasks |
| Drive System | Brushless DC magnetic drive |
| Interface | RS-232 |
| Tray Options | Adhesive polymer tray, stainless steel Erlenmeyer clamps, plastic Erlenmeyer clamps, Fernbach clamps, short/long tube racks, 187 mm mini-rack |
| Brand | INFORS |
|---|---|
| Origin | Switzerland |
| Model | Orbitron |
| Oscillation Frequency | 20–550 rpm |
| Orbit Diameter | 25 mm |
| Platform Quantity | 1 |
| Dimensions (W×D×H) | 640 × 600 × 150 mm |
| Weight | 26.5 kg |
| Max Load Capacity | 31 kg (dependent on platform type) |
| IP Rating | IP43 |
| Platform Options | N-type (480 × 420 mm), F-type (800 × 420 mm), M-type (850 × 470 mm) |
| Brand | INFORS |
|---|---|
| Origin | Switzerland |
| Model | Techfors Cell |
| Working Volume Range | 5–500 L (customizable up to 1,000+ L) |
| Control System | Safe-DDC Process Controller |
| Stirring Options | Top- or Bottom-Driven Impeller Configuration |
| Shaft Sealing | Single- or Dual-Mechanical Seal |
| CIP/SIP | Integrated In-Place Cleaning and Sterilization |
| Footprint | Space-Optimized Modular Design |
| Compliance | Designed for GMP/GLP-aligned bioprocess development and scale-up |
| Brand | INFORS |
|---|---|
| Origin | Switzerland |
| Model | Techfors-S |
| Volume Range | 5–20 L (standard configurations) |
| Sterilization | In-situ steam sterilization (SIP) |
| Control System | IRIS v4.0 with real-time monitoring & cascade control |
| Gas Control | 4+1 gas mixing station (Air/O₂/N₂/CO₂ + Air backup) with optional thermal mass flow controllers (MFCs) |
| Agitation | Top-driven mechanical stirring with adjustable speed (0–600 rpm) |
| Temperature Control | Jacketed vessel with independent steam/water pathways |
| Sampling | Bottom-centered sterile sampling valve with dedicated SIP line |
| Pumping | Up to 5 programmable digital peristaltic pumps (4 standard, 1 optional) |
| Filtration | 0.2 µm hydrophobic membrane filters (side-mounted inlet/outlet) |
| Data Interface | RS-232, Ethernet (optional), FDA 21 CFR Part 11 compliant audit trail (IRIS software) |
| Compliance | Designed to support GLP/GMP workflows |
| Brand | INFORS |
|---|---|
| Origin | Switzerland |
| Model | Terrafors-IS Bacteria |
| Vessel Capacity | 15 L (3–4 kg solid substrate or 7 L liquid medium) |
| Aeration System | Stainless steel sparger with 1 mm orifices |
| CO₂ Monitoring Range | 0–10% (NDIR sensor, ±1% FS repeatability) |
| O₂ Monitoring Range | 0–25% (Zirconia sensor, ±0.5% FS repeatability) |
| Temperature Control Range | +5 °C to 80 °C (in situ sterilization up to 134 °C) |
| Rotation Speed | 0.1–10 rpm (programmable profile) |
| Air Flow Rate | 3.6–36 NL/min (rotameter-controlled with automated inlet/outlet valves) |
| Material | 316L stainless steel drum vessel |
| Sterilization | Fully automated in-situ steam sterilization via integrated INFORS steam generator |
| User Interface | Color touchscreen controller with tab-based navigation, multi-level password protection, and support for up to 24 configurable process parameters |
| Brand | TSE Systems |
|---|---|
| Origin | Germany |
| Model | InfraMot – Activity System |
| Detection Principle | Passive Infrared (PIR) Thermal Imaging |
| Measurement Type | Total Locomotor and Postural Activity |
| Cage Compatibility | Universal (all standard rodent housing sizes) |
| Installation | Top-mounted or flexible spatial positioning |
| Light Condition Independence | Full spectrum — operates in total darkness |
| Temporal Resolution | Millisecond-level motion event detection |
| Calibration | Zero-calibration required |
| Integration | Modular component of PhenoMaster® and LabMaster® platforms |
| Cleaning | Removable sensor unit for routine decontamination |
| Compliance | Designed for GLP-compliant longitudinal phenotyping studies |
| Brand | TSE Systems |
|---|---|
| Origin | Germany |
| Model | InfraMot |
| Detection Principle | Passive Infrared (PIR) Thermal Imaging |
| Spatial Resolution | Cage-wide volumetric activity mapping |
| Temporal Resolution | Millisecond-level motion event detection |
| Installation | Top-mounted modular sensor unit compatible with PhenoMaster/LabMaster caging systems |
| Calibration | Factory-calibrated, zero user calibration required |
| Environmental Operation | Full light-independence (operational in total darkness or standard lighting) |
| Cage Compatibility | Universal fit for standard and custom rodent housing dimensions |
| Hygiene Design | Tool-free removable sensor head for autoclave-compatible cleaning |
| Origin | Germany |
|---|---|
| Manufacturer Type | Distributor |
| Import Status | Imported |
| Model | Inhalation Exposure System Control Software |
| Pricing | Upon Request |
| Brand | Inheco |
|---|---|
| Origin | Germany |
| Model | CPAC Ultraflat, CPAC Microplate |
| Temperature Range (1-TEC) | 4 °C to 70 °C |
| Temperature Range (2-TEC) | 4 °C to 110 °C |
| Plate Compatibility | 96-well, 384-well microplates |
| Mounting Options | Surface-mounted (Ultraflat), Embedded (Microplate) |
| Height (Ultraflat) | 80 mm |
| Height (Microplate active surface) | ~14 mm above deck |
| System Integration | Compatible with Agilent Bravo/BioCel, Beckman Biomek FX/NX/i-Series, Hamilton STAR/Nimbus/Vantage, PerkinElmer Sciclone/Zephyr/JANUS/Multiprobe II, Protodyne BioCube, Tecan Freedom EVO/Genesis/TEMO/Fluent |
| Control Interface | STC (Single TEC Control), MTC or MTC Compact (Multi-Module Control, up to 6 units) |
| Power Supply | 24 V DC |
| Weight | 10 kg |
| Dimensions (W×D×H) | 300 mm × 600 mm × 900 mm |
| Application | Integrated thermal control for NGS library preparation — amplicon-based workflows, enzymatic reactions, adapter ligation, cleanup incubations, and QC-compatible temperature staging |
| Brand | INNOPSYS |
|---|---|
| Origin | Germany |
| Model | InnoQuant |
| Laser Wavelengths | 375 nm, 488 nm, 561 nm, 640 nm |
| Detection Channels | 4 independent PMT detectors |
| Filter Wheels | 7-position per channel |
| Spatial Resolution | 0.5 µm/pixel |
| Scan Area | 18 mm × 18 mm (full slide, no tiling) |
| Scan Time | ≤17 min @ 0.5 µm/pixel |
| Output Format | 8-bit or 16-bit TIFF |
| Imaging Mode | Point-scanning confocal |
| Z-axis Auto-focus | Real-time dynamic focus tracking |
| Brand | INNOTEG |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Regional Category | Domestic (China) |
| Models | EasyDetec-UV, EasyDetec-UVW |
| Instrument Type | Portable (Handheld) |
| Wavelength Options | Dual-band UV (254 nm and 365 nm) |
| Power Consumption | 0–12 W |
| Battery-Powered Operation | Yes |
| Integrated Imaging | CMOS sensor + built-in display + Wi-Fi image transfer |
| Light Shielding | Integrated light-tight hood |
| Auto-power Sensing | Photoelectric sensor for standby activation |
| Image Capture | One-touch capture with automatic local storage |
| Brand | INNOTEG |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | EasyDetec-UVE |
| Instrument Type | Portable (Handheld) |
| Wavelength Options | 254 nm and 365 nm |
| Power Consumption | 6 W |
| Light Source | High-Efficiency UV LED |
| Rated Lifetime | ≥10,000 hours |
| Viewing Area Compatibility | 2.5 × 5 cm to 20 × 20 cm TLC plates or silica gel sheets |
| Battery | Rechargeable Li-ion (5000 mAh) |
| Filter Dimensions | Enlarged optical-grade UV-blocking filter for uniform illumination across full viewing area |
| Brand | Insplorion AB |
|---|---|
| Origin | Sweden |
| Model | Acoulyte |
| Sensor Diameter | 14 mm |
| Substrate | SiO₂-coated QCM-D crystal |
| Sensing Surface | Nanostructured gold |
| Standard Coatings | Si₃N₄, SiO₂, Al₂O₃, TiO₂ |
| Light Source | Tungsten-halogen lamp |
| Wavelength Range | 450–1000 nm |
| LSPR Sensitivity | ≤0.03 monolayer |
| Measurement Spot Diameter | 3 mm |
| Temporal Resolution | 10 Hz (10 samples/s) |
| Typical Noise Level | <0.01 nm |
| Optical Unit Dimensions (W×D×H) | 25×27×9 cm |
| Acoulyte Module Dimensions (W×D×H) | 8×5×3 cm |
| Software | Insplorer (Windows-compatible) |
| Data Export Format | ASCII text |
| Compatible Platforms | Q-Sense Explorer E1 & Analyzer E4 (with Q-Sense Window Module) |
| NPS Sensing Depth | <30 nm |
| QCM-D Hydrodynamic Penetration Depth | >300 nm |
| Simultaneous Output Parameters | LSPR resonance wavelength shift (Δλ), extinction intensity change, frequency shift (Δf), dissipation change (ΔD) |
| Brand | Insplorion AB |
|---|---|
| Origin | Sweden |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NPS Sensor Chip |
| Pricing | Upon Request |
| Brand | Insplorion AB |
|---|---|
| Origin | Sweden |
| Model | S2 |
| Analysis Time | 2 s |
| Temperature Control Range | 15 °C–45 °C (±0.1 °C stability) |
| Flow Cell | Dual-channel |
| Sample Dead Volume | 20 µL |
| Standard Syringe Volume | 250 µL |
| Typical Flow Rate | 12.5–250 µL/min |
| Standard Loop Volume | 200 µL |
| Sensor Substrate | Fused Silica |
| Sensing Layer | Nanostructured Gold |
| Detection Depth | Up to 30 nm |
| Light Source | Tungsten-Halogen Lamp (≥2000 h lifetime) |
| Measurement Spot Diameter | 1.5 mm |
| Temporal Resolution | Up to 10 Hz |
| Optical Noise | <0.1 nm (at 1 Hz sampling) |
| Sensor Dimensions | 9.5 × 9.5 × 1 mm |
| System Dimensions | 65 × 42 × 36 cm |
| Weight | 30 kg |
| Software | InControl 1.0 (Windows-compatible) |
| Data Output | Proprietary CSV/TSV format |
| Brand | Insplorion AB |
|---|---|
| Origin | Sweden |
| Model | XNano |
| Measurement Principle | Nanoplasmonic Resonance Spectroscopy (NPS) |
| Sample Environment | Liquid or Gas Flow |
| Temperature Range | 25–80 °C (optional up to 250 °C) |
| Chip Substrate | Fused Silica (9.5 × 9.5 × 1 mm) |
| Sensing Surface | Nanostructured Gold |
| Coating Options | Au, SiO₂, Si₃N₄, TiO₂, Al₂O₃ |
| Optical Source | Tungsten-Halogen Lamp (≥2000 h lifetime) |
| Wavelength Range | 450–1000 nm |
| Spot Size | ~2 mm diameter |
| Time Resolution | 10 Hz (10 samples/sec) |
| Noise Level | < 0.01 nm (in liquid, 1 Hz sampling) |
| Flow Cell Volume | ~4 μL |
| Minimum Sample Volume | ~100 μL |
| Typical Flow Rate | 20–100 μL/min |
| Materials | Titanium & Perfluoroelastomer® |
| Dimensions (Measurement Unit) | 31 × 25 × 25 cm |
| Software | Windows-compatible, ASCII output, multi-parameter real-time export (resonance wavelength, linewidth, extinction) |
| Brand | Instec |
|---|---|
| Origin | USA |
| Model | HCS60 |
| Temperature Range | 5 °C to 60 °C (optional up to 95 °C) |
| Temperature Resolution | 0.01 °C |
| Temperature Stability | ±0.1 °C at 37 °C |
| Max. Heating Rate | +50 °C/min at 37 °C |
| Max. Cooling Rate | −50 °C/min at 37 °C |
| Min. Heating/Cooling Rate | ±0.1 °C/hour |
| Control Method | PID with Variable Bipolar DC Control |
| Sensor | 100 Ω Platinum RTD |
| Working Distance | 5.6 mm (with optional insert) |
| Condenser Distance | 19.1 mm |
| Sample Area | 35 mm diameter |
| Chamber Height | 19 mm |
| Viewing Aperture | 13 mm (with insert), 20 mm (without insert) |
| Brand | Intavis |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | INTAVIS DigestPro MSi |
| Pricing | Available Upon Request |
| Brand | CEM |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | InsituPro Vsi |
| Instrument Type | In Situ Hybridization System |
| Temperature Range | 6–75 °C (Basket Mode), 10–70 °C (Slide Mode) |
| Buffer Volumes | 2×1000 mL, 3×50 mL, 6×125 mL, 7×50 mL |
| Brand | CEM |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | MultiPep 1 (SLi) / MultiPep 2 (RSi) |
| Amino Acid Delivery | Automated |
| Reagent Delivery | Automated |
| User Authentication | Password + Facial Recognition |
| Audit Trail | Yes |
| Synthesis Scale | 0.001–0.3 mmol |
| Brand | TSE Systems |
|---|---|
| Origin | Germany |
| Model | IntelliCage Add-On AnimalGate |
| Type | Modular RFID-Based Animal Access Gate for Automated Behavioral Phenotyping |
| Compliance | CE-marked, compatible with GLP-compliant data workflows |
| Software Integration | Fully controlled via IntelliCage Plus v5.0+ (FDA 21 CFR Part 11–ready audit trail, electronic signature support) |
| Optional Hardware | Integrated high-precision load cell (±0.1 g resolution, 500 g max capacity) |
| Brand | TSE Systems |
|---|---|
| Origin | Germany |
| Model | IntelliCage Add-On SocialBox |
| Type | RFID-Based Automated Social Behavior Monitoring Module for Mouse Ethology |
| Compatibility | Designed exclusively for IntelliCage Plus and IntelliCage Pro systems |
| Max Expansion | Up to 4 SocialBoxes per IntelliCage unit (5 total zones) |
| System Scalability | Up to 8 IntelliCage units or 32 SocialBoxes (128 mice) |
| Software Control | IntelliCage Plus v5.0+ with audit-trail-enabled experimental protocol scheduling |
| Regulatory Alignment | Compliant with GLP-compliant data integrity requirements |
| Brand | INTERHERENCE |
|---|---|
| Origin | Germany |
| Model | VAHEAT |
| Temperature Range | RT–200 °C |
| Temperature Stability | ±0.01 °C (RMS) |
| Power Consumption | Standard Version < 2500 mW |
| Heating Rate | Up to 100 °C/s (local), 40 °C/s (in liquid) |
| Compatible Microscopy Modes | Widefield, Confocal, TIRF, iSCAT, STED, SIM, PALM, STORM, PAINT, AFM |
| Brand | Interscience |
|---|---|
| Origin | France |
| Model | easySpira Dilutel® |
| Syringe Capacity | 1000 µL |
| Preset Inoculation Volumes | 50 µL, 100 µL, 200 µL |
| Counting Range | 30–1×10¹² CFU/mL |
| Cycle Time (1 aspiration + 1 disinfection + 1 plating) | 25 s |
| Cycle Time (1 disinfection + 5 dilutions + 1 plating at one dilution factor) | 134 s |
| Cycle Time (1 disinfection + 5 dilutions + 1 plating per dilution factor) | 234 s |
| Needle Pressure | up to 8 bar |
| Automatic Disinfection Cycles | 1000 cycles (using 2 L bottle) |
| Automatic Dilution Cycles | 63 cycles (using 2 L bottle) |
| Compatible Diluents | Saline, Ringer’s solution |
| Max. Petri Dishes per Sample (50 µL) | 20 |
| Spiral Plating Mode | Optional (Ø90 mm & Ø150 mm dishes) |
| Loop Plating Mode | Optional (3 dilutions on Ø90 mm |
| Uniform Plating Mode | Optional (Ø55 mm, Ø90 mm, Ø150 mm) |
| Pour Plate Mode | Optional (Ø55 mm, Ø90 mm, Ø150 mm) |
| Editable Inoculation Volume via USB | 10–1000 µL |
| Traceability | Excel™ export, LIMS integration, DataLink™ compatibility |
| Sterilizable Components | Two autoclavable bottles (diluent & disinfectant) + connectors |
| Cross-Contamination Prevention | Overflow cleaning technology |
| Brand | Interscience |
|---|---|
| Origin | France |
| Model | easySpiral Pro |
| Compliance | AFNOR V08-100, ISO 7218, SN/T 2098–2008 |
| Sample Volume Range | 10–1000 µL (programmable via USB) |
| Plating Time | ≤25 s per plate (including wash, aspirate, and spiral deposition) |
| Detection Range | 30–1.1 × 10⁷ CFU/mL |
| Sterilization | Autoclavable components (GL45 bottle adapters, needle assembly, base plate) |
| Cleaning System | Overflow-based internal/external needle rinse with real-time fluid-level sensing |
| Connectivity | USB interface for method programming, audit trail export, and GLP-compliant data logging |
| Brand | Interscience |
|---|---|
| Origin | France |
| Model | easySpiral Pro Milk |
| Syringe Capacity | 1000 µL |
| Preset Volumes | 50 µL, 100 µL, 200 µL |
| Adjustable Volume Range | 10–1000 µL via USB |
| Sample Input Format | Tube (80 × 35 mm) |
| CFU Counting Range | 10²–10⁷ CFU/mL |
| Cycle Time (aspiration + disinfection + plating) | 25 s |
| Needle Pressure | up to 8 bar |
| Auto-Disinfection Cycles per 2 L Bottle | 1000 |
| Auto-Rinse Cycles per 2 L Bottle | 600 |
| Max. Plates per Sample | 20 (at 50 µL) |
| Compatible Petri Dish Diameters | Ø90 mm and Ø150 mm |
| Plating Modes | Spiral (logarithmic), Pour, Loop (circular), Uniform |
| Compliance | ISO 7218, ISO 4833-2, FDA BAM, AOAC 977.27 |
| Voltage/Frequency | 100–240 V~, 50–60 Hz |
| Fuse | T1.6A L 250V, 5 × 20 mm |
| Power Consumption | 45 W |
| Brand | Interscience |
|---|---|
| Origin | France |
| Model | easySpiral Pro® |
| Dispensing Volume | 1000 µL |
| Preset Volumes | 50, 100, or 200 µL |
| Counting Range | 100–1×10⁷ CFU/mL |
| Cycle Time | 25 s |
| Overflow Pressure | 8 bar |
| Disinfectant Capacity (Standard Mode) | 600 cycles (2 L bottle) |
| Same-Sample Sequential Plating | up to 50 Petri dishes (50 µL each) |
| Automatic Disinfection Protocol | Compatible with 90 mm and 150 mm Petri dishes |
| Spiral Modes | Exponential, Circular, Uniform |
| Data Export | Excel™ format |
| Programmable Volume Range | 10–1000 mL |
| Dimensions | 38 × 42 × 29 cm |
| Weight | 15.6 kg |
| Power Supply | 100–240 V, 50/60 Hz |