| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Regional Origin | Domestic (PRC) |
| Model | 2001-B-III |
| Instrument Category | Magnetic Bead-Based Nucleic Acid Purification |
| Automation Level | Dedicated Fully Automatic |
| Batch Sample Capacity | 100 samples |
| Sample Volume Range | 12 mL per tube |
| Fraction Collection Time Range | 1 s – 199 h 59 min 59 s |
| Wavelength Options | 214 nm, 254 nm, 280 nm |
| Flow Rate Range | 1–14,500 mL/h |
| Flow Accuracy | ±1% |
| Pump Speed Resolution | 0.1–150 rpm (bidirectional) |
| OD Detection | Triple-channel real-time A-value output (214/254/280 nm) |
| Fraction Collection Modes | Time-based, Drop-counting, Peak-threshold (0–100 mV) |
| Collection Vial Capacity | 100 × 12 mL tubes with numeric indexing |
| Column Compatibility | Direct interface with GE Healthcare AKTA-scale prepacked columns (1.0×50 cm, 1.0×70 cm, 2.6×50 cm included) |
| System Control | Embedded microprocessor with blue-membrane LCD display |
| Software | PC-based chromatogram acquisition, peak integration, relative quantitation, and report generation (AUC-based normalization) |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | FWA-201B |
| Instrument Type | Darkroom-style |
| Wavelength Options | Dual-band (254 nm & 365 nm) |
| UV Filter Dimensions | 200 × 50 mm |
| UV Lamp Power | 16 W |
| Input Voltage | AC 220 V ± 10%, 50/60 Hz |
| UV Intensity at 20 cm | ≥20 µW/cm² |
| Built-in Rechargeable Li-ion Battery | 4800 mAh |
| Display | LCD with Chinese interface |
| Image Storage Capacity | ≥5000 frames |
| Dimensions (L×W×H) | 310 × 200 × 300 mm |
| Weight | 3 kg |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | HD-2000 |
| Detection Wavelengths | 220 nm, 254 nm, 280 nm, 340 nm |
| Wavelength Accuracy | ±1 nm |
| Flow Cell Path Length | 3 mm |
| Flow Cell Volume | 100 µL |
| Minimum Detectable Concentration | 48 µg/mL |
| Absorbance Range | 0.05 A – 2 A |
| Transmittance Range | 0–100 %T |
| Display | Triple-channel LED readout of OD values (A254, A280, A340 or user-selectable) |
| Microprocessor Control | Embedded MCU with real-time analog signal processing |
| Compatibility | Standard Luer-lock and GE/AKTA-compatible column interfaces |
| Gradient Type | Linear gradient support |
| Purification Principle | Ion Exchange Chromatography (IEX) |
| Power Supply | AC 220 V ±10 %, 50 Hz |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | HD-2000 |
| Detection Wavelengths | 220 nm, 254 nm, 280 nm, 340 nm |
| Flow Cell | 100 µL volume, 3 mm path length |
| Absorbance Range | 0.05 A to 2 A (7 ranges) |
| Wavelength Accuracy | ±1 nm |
| Detector Type | Fixed-wavelength UV photometer |
| Gradient Capability | Linear gradient support |
| Interface | GE/AKTA-compatible column fittings |
| Display | LED-based, triple-channel OD readout (simultaneous display of three absorbance values) |
| Control | Embedded microcontroller architecture |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | HD-3000 |
| Detection Wavelengths | 214 nm, 220 nm, 254 nm, 280 nm, 340 nm |
| Wavelength Accuracy | ±1 nm |
| Flow Cell | 80 µL volume, 4 mm path length |
| Absorbance Range | 0.05 A to 2 A (7 gain ranges) |
| Transmittance Range | 0–100 %T |
| Minimum Detectable Concentration | 48 µg/mL (for BSA at 280 nm) |
| Display | Triple-channel LED display of real-time OD values |
| Data Interface | USB and RS-232 (COM) |
| Software | Dedicated chromatography analysis software for Windows XP/7/10 (PC not included) |
| Compatibility | GE Healthcare AKTA system interface-ready |
| Purification Principle | Ion Exchange Chromatography (IEX) |
| Gradient Type | Linear gradient support |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | HD-97-1 |
| Detection Wavelengths | 220 nm, 254 nm, 280 nm, 340 nm |
| Wavelength Accuracy | ±1 nm |
| Flow Cell Path Length | 3 mm |
| Flow Cell Volume | 100 µL |
| Minimum Detectable Concentration | 48 µg/mL |
| Absorbance Range | 0.05 A – 2 A (7 ranges) |
| Transmittance Range | 0–100% T |
| Display | High-clarity LED, triple-channel OD readout |
| Control System | Embedded microcomputer chip |
| Compatibility | GE/AKTA-compatible column fittings |
| Gradient Type | Linear |
| Max. System Pressure | 3 MPa |
| Purification Principle | Ion Exchange Chromatography (IEX) |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | HD-97-1 |
| Detection Wavelengths | 220 nm, 254 nm, 280 nm, 340 nm |
| Flow Cell | 100 µL volume, 3 mm path length |
| Absorbance Range | 0.05 A to 2 A (7 ranges) |
| Wavelength Accuracy | ±1 nm |
| Compatibility | GE/AKTA-compatible column interfaces |
| Purification Principle | Ion Exchange Chromatography (IEX) |
| Gradient Type | Linear |
| Display | LED, triple-channel OD readout (A₂₂₀, A₂₅₄, A₂₈₀) |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | JP-2000 |
| Purification Principle | Ion Exchange Chromatography (IEX) |
| Gradient Type | Linear Gradient |
| Detection Wavelengths | 260 nm, 280 nm, 295 nm, 310 nm |
| Maximum System Pressure | 3 MPa |
| Light Source | LED (Lifespan > 50,000 h) |
| Optical Path Length | 2 mm |
| Sample Cell Volume | 10–120 µL |
| Baseline Noise | < 0.0001 A |
| Drift | ≤ 0.002 A/s |
| Sensitivity Range | 0.05–4 A (adjustable in 7 steps) |
| Zeroing | Dual-beam one-touch auto-zero |
| Display | High-definition blue-membrane LCD |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 205 × 300 × 180 mm |
| Weight | 2.6 kg |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | JP-2880 |
| Instrument Type | Standard Gel Imaging System |
| CCD Resolution | 5 MP (3096 × 2080) |
| Bit Depth | 16-bit |
| Dynamic Range | >4.5 OD |
| CCD Sensor Size | 1/2.5" |
| Minimum Detectable DNA | 0.01 ng (EB-stained dsDNA) |
| Signal-to-Noise Ratio | ≥56 dB |
| Lens | Motorized High-Transmission Zoom Lens (Computar, 8–48 mm, f/1.2) |
| Transmission UV Source | 302 nm (210 × 260 mm area) |
| Optional Blue/White Light Transilluminator | 210 × 300 mm |
| Standard Emission Filter | 590 nm |
| Software | JP-GEL 1D Image Analysis Suite |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 380 × 430 × 730 mm |
| Weight | 18.1 kg |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | JP-3000 |
| Purification Principle | Ion Exchange Chromatography (IEX) |
| Gradient Type | Linear Gradient |
| Detector Type | UV-Vis Absorbance Detector |
| Detection Range | –6 AU to +6 AU |
| Pressure Rating | 3 MPa |
| Wavelengths | 260 nm, 280 nm, 295 nm, 310 nm |
| Minimum Detectable Concentration | 20 µg/mL |
| Light Source | LED (Lifespan > 50,000 h) |
| Optical Path Length | 2 mm |
| Flow Cell Volume | 10–120 µL |
| Baseline Stability | Drift ≤ 0.002 A/h |
| Noise | < 0.0001 A (RMS) |
| Sensitivity Settings | 0.05–4 A full scale |
| Zero Adjustment | Dual-beam real-time auto-zero |
| Display | High-contrast blue-membrane LCD |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 205 × 300 × 180 mm |
| Weight | 2.6 kg |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | JP-3001 |
| Purification Principle | Gel Filtration Chromatography (GFC) |
| Gradient Type | Linear Gradient |
| Detector Type | Dual-Beam UV Absorbance Detector |
| Detection Wavelengths | 260 nm, 280 nm, 295 nm, 310 nm |
| Minimum Detectable Concentration | 20 µg/mL |
| Light Source | High-Stability LED (Lifespan > 50,000 h) |
| Optical Path Length | 2 mm |
| Flow Cell Volume | 10–120 µL |
| Baseline Noise | < 0.0001 AU |
| Drift | ≤ 0.002 AU/s |
| Absorbance Sensitivity Range | 0.05–2.0 AU (adjustable in 6 steps) |
| Zero Calibration | Real-time dual-beam auto-zero |
| Display | 10.1-inch capacitive touchscreen LCD |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 290 × 330 × 470 mm |
| Weight | 9 kg |
| Max Operating Pressure | 3 MPa |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | JP-3006 |
| Purification Principle | Ion Exchange Chromatography (IEX) |
| Gradient Type | Linear |
| Flow Rate Range | 0.1–10 mL/min |
| Flow Rate Accuracy | ±1.2% |
| Detection Range | −6 AU to +6 AU |
| Maximum Pressure | 3 MPa |
| UV Wavelengths | 260 nm, 280 nm, 295 nm, 310 nm |
| Wavelength Accuracy | ±1 nm |
| Linearity | ±1.5% (0–2 AU) |
| Sample Cell Volume | 10 µL |
| Operating Temperature | 4–40 °C |
| Dimensions (W×D×H) | 345 × 380 × 255 mm |
| Weight | 6.6 kg |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | JP-3007 |
| Purification Principle | Ion Exchange Chromatography (IEX) |
| Gradient Type | Linear Gradient |
| Detector Type | UV Absorbance Detector |
| Flow Rate Range | 0.1–10 mL/min |
| Flow Rate Accuracy | ±1.2% |
| Detection Range | –6 AU to +6 AU |
| Maximum Pressure | 3 MPa |
| Wavelength Options | 260 nm, 280 nm, 295 nm, 310 nm |
| Wavelength Accuracy | ±1 nm |
| Linearity | ±1.5% (0–2 AU) |
| Sample Cell Volume | 10 µL |
| Operating Temperature | 4–40 °C |
| Dimensions (W×D×H) | 360 × 360 × 470 mm |
| Weight | 10.6 kg |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | JP-3008 |
| Detection Range | 190–400 nm |
| Light Source | Deuterium Lamp (≥1000 h warranty) |
| Optical Path Length | 1 mm |
| Flow Cell Volume | 10–120 µL |
| Spectral Bandwidth | 6 nm |
| Wavelength Accuracy | ≤ ±1 nm |
| Wavelength Repeatability | ≤ ±0.1 nm |
| Baseline Noise | < 0.0001 AU |
| Baseline Drift | ≤ 0.002 AU/s |
| Wavelength Control | Stepper Motor–Driven Monochromator |
| Data Acquisition Rate | Dual-Channel High-Speed Sampling |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 340 × 330 × 175 mm |
| Weight | 6 kg |
| Integrated Touchscreen Display | 12-inch Industrial LCD |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | JP-388Plus |
| CCD Resolution | 20 MP (5472 × 3660) |
| Bit Depth | 16-bit |
| Dynamic Range | 4.5 OD |
| CCD Sensor Size | 1-inch |
| Signal-to-Noise Ratio | ≥42 dB |
| Lens | Motorized Zoom Lens, 8–48 mm (6× optical zoom), f/1.2 aperture |
| UV Excitation | Transmitted 300 nm |
| UV Transilluminator Area | 210 × 260 mm |
| Blue/White Light Converter Plate | 210 × 300 mm |
| Standard Emission Filter | 590 nm |
| Software | JP-GEL 1D & JP Analysis 3.3 |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 440 × 430 × 460 mm |
| Weight | 19 kg |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | JP-K300 |
| Instrument Type | Chemiluminescence Gel Imaging System |
| CCD Resolution | 9 MP (3000 × 3000) |
| Bit Depth | 16-bit |
| Dynamic Range | 4.8 OD |
| CCD Sensor Size | 4/3" |
| Pixel Size | 5.4 µm × 5.4 µm |
| Cooling Temperature | −45 °C (ΔT ≈ −65 °C vs ambient) |
| Quantum Efficiency | >75% |
| Lens Aperture | f/0.95 Fixed-Focus Macro Lens |
| White Light Source | Top-Mounted Uniform LED Panel |
| Minimum Detectable DNA | 0.01 ng (EB-stained) |
| Dark Current | <0.0005 e⁻/pixel/s |
| SNR | ≥56 dB |
| Dual Imaging Area | 9.5 × 9.5 cm & 12.5 × 12.5 cm |
| Power Input | AC 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 390 × 440 × 735 mm |
| Weight | 18.3 kg |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | JP-K3300Plus |
| Instrument Type | Chemiluminescence Gel Imaging System |
| CCD Resolution | 9 MP (3000 × 3000) |
| Bit Depth | 16-bit |
| Dynamic Range | 4.8 OD (0–65535 grayscale) |
| Pixel Size | 5.4 µm × 5.4 µm |
| Sensor Format | 4/3-inch Sony IMX533CLK-D |
| Cooling Temperature | −45 °C (ΔT ≤ −65 °C vs ambient) |
| Lens Aperture | f/0.95 fixed-focus lens |
| Signal-to-Noise Ratio | ≥56 dB |
| Quantum Efficiency | >75% |
| White Light Source | Top-mounted uniform LED transilluminator |
| Dual Imaging Area | 9.5 × 9.5 cm & 12.5 × 12.5 cm |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 390 × 440 × 735 mm |
| Weight | 18.3 kg |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | JP-K3600Plus |
| Instrument Type | Chemiluminescence Gel Imaging System |
| CCD Resolution | 9 MP (3000 × 3000) |
| Bit Depth | 16-bit |
| Dynamic Range | 4.8 OD |
| CCD Sensor Size | 4/3" |
| Detection Sensitivity | ≥0.02 ng Protein, ≥0.05 ng DNA |
| Signal-to-Noise Ratio | ≥56 dB |
| Lens | Motorized Optical Zoom 8–48 mm (6×), f/0.95 Fixed Aperture (optional f/0.8) |
| Cooling Temperature | −45 °C (ΔT ≤ −65 °C vs ambient) |
| Pixel Size | 5.4 µm × 5.4 µm |
| Pixel Binning Modes | 1×1 to 8×8 |
| Transmission White Light Panel | Uniform LED Illuminator |
| UV Transilluminator | 200 × 200 mm, 300 nm (transmission), optional 254/365 nm reflectance |
| Filter Wheel | 5-position motorized (optional 10-position), standard F590 emission filter |
| Dimensions (W×D×H) | 390 × 440 × 735 mm |
| Weight | 18.3 kg |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | JP-K3900 |
| Imaging Modality | Chemiluminescence, Fluorescence (UV/Blue/Green/Red), White Light Transmission & Reflection |
| CCD Sensor | Sony IMX533CLK-D, 4/3-inch format, 3000 × 3000 (9 MP) |
| Pixel Size | 5.4 µm × 5.4 µm |
| Bit Depth | 16-bit (0–65,535 grayscale) |
| Dynamic Range | >4.8 OD |
| Cooling Temperature | −45 °C (ΔT ≤ −65 °C vs ambient) |
| Quantum Efficiency | >75% |
| Lens | Computar F/0.95, 8–48 mm motorized zoom lens |
| Signal-to-Noise Ratio | ≥56 dB |
| Detection Sensitivity | Protein ≥0.02 ng, DNA ≥0.05 ng (chemiluminescent substrates) |
| Dark Current | <0.0005 e⁻/pixel/s |
| Transmission UV Sources | 302 nm (standard), 254 nm & 365 nm (optional reflectance) |
| UV Transilluminator | 200 × 200 mm, high-intensity |
| White Light Source | Top-mounted, uniform LED panel with >90% homogeneity |
| Sample Stage | Dual-position drawer-style platform (9.5 × 9.5 cm and 12.5 × 12.5 cm imaging areas) |
| Filter Wheel | Motorized 5-position (standard), optional 10-position |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W × D × H) | 390 × 440 × 735 mm |
| Weight | 18.3 kg |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | JP-K3900Plus |
| Imaging Type | Multicolor Fluorescence & Chemiluminescence Gel Imager |
| CCD Resolution | 9 MP (3000 × 3000) |
| Bit Depth | 16-bit |
| Dynamic Range | 0–4.8 OD |
| CCD Sensor Size | 4/3" (SONY IMX533CLK-D) |
| Pixel Size | 5.4 µm × 5.4 µm |
| Cooling Temperature | −45 °C (ΔT ≈ −65 °C vs. ambient) |
| Quantum Efficiency | >75% |
| Lens | F/0.95 Fixed Focus (optional F/0.8) |
| Optical Zoom | 8–48 mm (6×) |
| Detection Sensitivity | ≥0.02 ng Protein (Western blot), ≥0.05 ng DNA (ethidium bromide-stained) |
| Signal-to-Noise Ratio | ≥56 dB |
| Transmission UV Sources | 300 nm (standard), 254/365 nm (optional reflectance) |
| UV Transilluminator Area | 200 × 200 mm |
| White Light Transmission Panel | Uniform LED-based, integrated |
| Filter Wheel | Motorized 5-position (optional 10-position), with standard bandpass filters at 535, 590, 605, and 699 nm |
| Imaging Area Options | 9.5 × 9.5 cm and 12.5 × 12.5 cm (dual-stage drawer platform) |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W × D × H) | 390 × 440 × 735 mm |
| Weight | 18.3 kg |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Region of Origin | Domestic (China) |
| Model | JP-K4600 |
| Instrument Type | Chemiluminescence Gel Imaging System |
| CCD Resolution | 9 MP (3000 × 3000) |
| Bit Depth | 16-bit |
| Dynamic Range | 0–4.8 OD |
| CCD Sensor Size | 4/3-inch (SONY IMX533CLK-D) |
| Detection Sensitivity | ≥0.02 ng for Protein |
| Signal-to-Noise Ratio | 56 dB |
| Lens | Fixed F/0.95 lens (optional F/0.8), 8–48 mm optical zoom (6× zoom ratio) |
| Sample Stage | 11 × 11 cm illuminated platform with anti-scatter design |
| Cooling Temperature | −45 °C (ΔT = −65 °C vs ambient) |
| Pixel Size | 5.4 µm × 5.4 µm |
| Pixel Binning | 1×1 to 8×8 |
| Dark Current | <0.0005 e⁻/pixel/s |
| White Light Source | Top-mounted, uniform illumination |
| Image Area | 10 × 8.8 cm |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 295 × 245 × 450 mm |
| Weight | 5 kg |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | JP-K4600Plus |
| Instrument Type | Chemiluminescence Gel Imaging System |
| CCD Resolution | 3000 × 3000 (9 MP) |
| Bit Depth | 16-bit |
| Dynamic Range | 4.8 OD |
| CCD Sensor Size | 4/3-inch |
| Detection Sensitivity | 4.8 OD at 16-bit grayscale (0–65,535) |
| Signal-to-Noise Ratio | ≥56 dB |
| Lens | Motorized Optical Zoom 8–48 mm (6× zoom ratio) |
| Cooling Temperature | −45 °C (ΔT ≈ −65 °C vs. ambient) |
| Pixel Size | 5.4 µm × 5.4 µm |
| Pixel Binning Options | 1×1 to 8×8 |
| Quantum Efficiency | >75% |
| Dark Current | <0.0005 e⁻/pixel/s |
| White Light Source | Top-mounted, uniform illumination |
| Imaging Area | 10 cm × 8.8 cm |
| Sample Stage | Motorized drawer-type, 11 cm × 11 cm active area |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 295 × 245 × 450 mm |
| Weight | 5 kg |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | JP-K600 |
| Instrument Type | Chemiluminescence Gel Imaging System |
| CCD Resolution | 9 MP (3000 × 3000) |
| Bit Depth | 16-bit |
| Dynamic Range | >4.0 OD (4.8 OD typical) |
| CCD Sensor Size | 4/3" (SONY IMX533CLK-D) |
| Pixel Size | 5.4 µm × 5.4 µm |
| Cooling Temperature | −45 °C (ΔT ≈ −65 °C vs ambient) |
| Lens Aperture | f/0.95 fixed-focus macro lens |
| Detection Sensitivity | <20 pg double-stranded DNA stained with ethidium bromide |
| Signal-to-Noise Ratio | ≥56 dB |
| White Light Transmission Area | 200 × 200 mm |
| UV Transillumination | 300 nm (transmission), optional 254/365 nm (reflection) |
| Filter Wheel | 5-position motorized (optional 10-position) |
| Standard Emission Filter | 590 nm |
| Dimensions (W×D×H) | 390 × 440 × 735 mm |
| Weight | 18.3 kg |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | JP-UV2 |
| Instrument Type | Darkroom-style |
| Wavelengths | 254 nm, 302 nm (transmission), 365 nm (reflection) |
| Filter Thickness | 5 mm amber short-pass filter |
| UV Lamp Count | 10 × 8 W tubes |
| Transmission Area | 260 × 210 mm |
| Filter Dimensions | 200 × 80 mm (reflection), 260 × 210 mm (transmission) |
| Power Input | AC 220 V, 50/60 Hz |
| UV Intensity at 20 cm | ≥20 µW/cm² |
| White Light Source | 10 W, 5500 K LED |
| Touchscreen | 4.3-inch capacitive LCD |
| Weight | 5.3 kg |
| Dimensions (L×W×H) | 440 × 338 × 270 mm |
| Compliance | JJF 1936–2021 (National Verification Regulation for UV Analyzers), Patented Design (ZL2012205175136, ZL201920792756.2) |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | Nano-600 |
| Sample Volume | 0.5–2.0 µL |
| Analytes | dsDNA, RNA, BSA |
| DNA Detection Range | 2–17,500 ng/µL (dsDNA) |
| Protein Detection Range | 0–440 mg/mL (BSA) |
| Wavelength Accuracy | ±1 nm |
| Measurement Time | ≤5 s |
| Wavelength Range | 185–910 nm |
| Absorbance Range (10-mm equivalent) | 0.02–300 A |
| Absorbance Precision | ±0.002 A |
| Absorbance Accuracy | ±1% (at 7.332 A, 260 nm) |
| Optical Path Lengths | 0.05 mm, 0.2 mm, 1.0 mm (auto-switching) |
| Light Source | Xenon flash lamp (rated lifetime ≥10 years) |
| Detector | 3648-pixel linear CCD array |
| Wavelength Resolution | ≤3 nm FWHM (at Hg 546 nm) |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 270 × 210 × 196 mm |
| Weight | 3.5 kg |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | Nano-900 |
| Detection Time | ≤5 s |
| Wavelength Accuracy | ±1 nm (7.332 Abs at 260 nm) |
| BSA Detection Range | 0.06–1100 mg/mL |
| dsDNA Detection Range | 0–38880 ng/µL |
| Sample Volume Requirement | 0.5–2 µL |
| Wavelength Range | 185–910 nm |
| Absorbance Range (10-mm equivalent) | 0–780 A |
| OD600 Mode | 600 ± 8 nm, 0–4 A |
| Light Source | Xenon flash lamp (≥10-year lifetime) |
| Detector | 3648-pixel linear CCD array |
| Wavelength Resolution | ≤3 nm (FWHM at Hg 546 nm) |
| Absorbance Precision | ±0.002 Abs |
| Absorbance Accuracy | ±1% (at 7.332 Abs, 260 nm) |
| Optical Path Lengths | Auto-switching 1.0 / 0.5 / 0.1 / 0.05 / 0.02 mm |
| Fluorescence Option | Excitation 460 nm, Emission 525 nm |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions | 270 × 210 × 190 mm |
| Weight | 4.6 kg |
| Data Export | USB port, SD-RAM card |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | UV-1000 |
| Instrument Type | Benchtop |
| UV Wavelength | 302 nm (transmission) |
| UV Lamp Configuration | Eight 8 W low-pressure mercury lamps |
| UV Transmission Area | 200 × 250 mm |
| UV Filter Dimensions | 200 × 200 mm |
| Power Consumption | 64 W |
| UV Intensity | ≥20 µW/cm² at 20 cm distance (per JJF 1936–2021) |
| Cut Window UV Blocking Efficiency | >99% |
| Input Voltage | AC 220 V, 50/60 Hz |
| Dimensions (L×W×H) | 325 × 260 × 140 mm |
| Net Weight | 2.3 kg |
| Compliance | Designed and validated per JJF 1936–2021 “Verification Regulation for UV Analyzers” |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | UV-2000 |
| Instrument Type | Darkroom-style transilluminator |
| Wavelength Modes | Multi-wavelength (transmission: 302 nm |
| reflection | 254 nm & 365 nm) |
| UV Lamp Count | 12 × 8 W tubes |
| Transmission Filter Size | 200 × 250 mm |
| Transmission Area | 200 × 250 mm |
| Reflected Light Filter Size | 200 × 50 mm (for 254/365 nm) |
| White Light Panel Size | 210 × 260 mm |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (L×W×H) | 420 × 355 × 580 mm |
| Weight | 10 kg |
| UV Intensity | ≥20 µW/cm² at 20 cm distance (302 nm transmission) |
| Safety Features | UV-blocking shield (blocks >99% UV), automatic lamp shutoff upon drawer opening, integrated cooling fan |
| Compliance | Designed per JJF 1936–2021 “Verification Regulation for UV Analyzers” (PRC National Metrological Technical Specification) |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | UV-3000 |
| Instrument Type | Darkroom-style transilluminator |
| Wavelength Modes | Multi-wavelength (transmission: 302 nm |
| reflection | 254 nm & 365 nm) |
| UV Lamp Count | 12 × 8 W tubes |
| Transmission Filter Size | 200 × 250 mm |
| Reflection Filter Area | 200 × 50 mm (dual-side) |
| Transmission Illuminated Area | 200 × 250 mm |
| White Light Panel Size | 210 × 260 mm |
| White Light Source | 4 W LED panel |
| Input Power | AC 220 V, 50/60 Hz |
| UV Intensity at 20 cm | ≥20 µW/cm² |
| Compliance | JJF 1936–2021 (National Verification Regulation for UV Analyzers) |
| Dimensions (L×W×H) | 420 × 355 × 580 mm |
| Net Weight | 10 kg |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | UV-A |
| Instrument Type | Darkroom-style |
| Wavelengths | 254 nm & 365 nm (dual-band) |
| UV Filter Dimensions | 200 × 50 mm |
| UV Lamps | 8 W × 2 (low-pressure mercury vapor lamps) |
| Power Consumption | 20 W |
| UV Intensity | ≥20 µW/cm² at 20 cm distance from lamp surface |
| Input Voltage | AC 220 V, 50/60 Hz |
| Dimensions (L×W×H) | 340 × 270 × 265 mm |
| Net Weight | 2.0 kg |
| Compliance | JJF 1936–2021 “Verification Regulation for Ultraviolet Analyzers” (drafting enterprise) |
| Patents | ZL202221777391.4, ZL202222383825.9 |