Life Science Instruments
Filter
Showing 5161–5190 of 6354 results
| Brand | Thermo Fisher |
|---|---|
| Origin | Imported |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model Number | 8960086V |
| Effective Storage Capacity | 600 × 2-inch cryoboxes |
| Internal Dimensions | 28.3 × 34.4 × 51.2 in. (71.9 × 87.3 × 130.1 cm) |
| External Dimensions | 37.6 × 39.6 × 78 in. (95.5 × 100.6 × 198.1 cm) |
| Power Supply | 230 V, 50 Hz |
| Rated Power Consumption | 400 W |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Product Category | Imported Instrument |
| Model | Scientific™ Forma™ |
| Effective Capacity | 368 L |
| Interior Dimensions (mm) | 1308 × 584 × 490 |
| Exterior Dimensions (mm) | 1979 × 846 × 836 |
| Power Supply | 230 V / 50 Hz |
| Rated Power | 400 W |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Category | Imported Instrument |
| Model Numbers | 51026281 (Heracell 150i), 50116049 (Heracell 240i) |
| Price Range | USD 13,500 – 68,000 |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | HERAcell 150i |
| Temperature Range & Accuracy | 3–55 °C |
| Temperature Uniformity | ±0.5 °C |
| Humidity Control | >99.5% RH (non-condensing) |
| Chamber Capacity | 150 L |
| Sterilization Method | ContraCon 90 °C moist-heat |
| CO₂ Sensing Options | Thermal Conductivity (TC) or Dual-Beam Infrared (IR) |
| Optional O₂ Control Range | 1–21% or 5–90% |
| Interior Material | Electropolished stainless steel (optional 100% pure copper) |
| Door Configuration | Triple-pane tempered glass inner doors (3-door configuration for 150 L) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Models | 51026333, 51026334 |
| Temperature Range & Accuracy | 0–50 °C ±0.1 °C |
| Temperature Uniformity | ±0.5 °C |
| Humidity Control Range & Accuracy | 5–95% RH ±2% RH (at 37 °C, 5% CO₂) |
| Chamber Capacity | 240 L |
| Sterilization Method | In-chamber 90 °C moist-heat (ContraCon) |
| Interior Material | Electropolished stainless steel or optional copper-lined chamber |
| Humidity System | Water-jacket-free, active humidity generation |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BBD6220 |
| Pricing | Available Upon Request |
| Temperature Range | Ambient +5 °C to 55 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Temperature Uniformity | ±0.2 °C @ 37 °C |
| CO₂ Control Accuracy | < ±0.1% |
| CO₂ Range | 0–20% (resolution: 0.1%) |
| O₂ Range | 1–20% (resolution: 0.1%) |
| Relative Humidity | Ambient to 95% RH @ 37 °C |
| Internal Volume Options | 150 L, 220 L, 240 L |
| Chamber Material | Electropolished Stainless Steel or Antimicrobial Copper Alloy |
| Sterilization Modes | 90 °C Wet-Heat Automatic Cycle or 180 °C Dry-Heat Cycle |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Type | Imported Instrument |
| Models | HERAcell 150i, HERAcell 240i |
| Chamber Material Options | Stainless Steel or 100% Pure Copper |
| ContraCon Sterilization | 90°C moist-heat, 25-hour cycle (validated at 90°C/9 K·h⁻¹) |
| Temperature Range | Ambient +3°C to 55°C |
| Temp Uniformity | ±0.5 K spatially, ±0.1 K over time |
| CO₂ Control Options | Thermal Conductivity (TC) or Dual-Beam Infrared (IR) sensor |
| Optional O₂ Control Ranges | 1–21% or 5–90% |
| Humidity System | Water-free, heated base with angled reservoir (5× faster recovery vs. conventional water pan) |
| Internal Door Configuration | 3-panel (150i) or 6-panel tempered glass |
| Shelving | Full-width (423×465 mm / 560×500 mm), max 10/12 shelves |
| Load Capacity | 10 kg/shelf (full), 5 kg/shelf (half) |
| Sterilization Efficacy | Validated against bacteria, fungi, USP <23> spores, and mycoplasma |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | Heracell VIOS 160i / Steri-cycle i160 |
| Temperature Range & Accuracy | 3–55 °C |
| Temperature Uniformity | ±0.2 °C |
| Humidity Range & Accuracy | 20–95 % RH |
| Chamber Capacity | 165 L |
| Sterilization Method | 180 °C Dry-Heat |
| Air Filtration | ISO Class 5 HEPA |
| CO₂ Control | IR-based, with iCAN intelligent logging system |
| Cell Compartmentalization | Cell Locker™ modular chamber system |
| Airflow Technology | THRIVE™ rapid-recovery laminar airflow |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Models | 50145502 / 51030287 / 51030478 / 50145515 |
| Price Range | USD $13,500 – $67,500 (based on configuration and regional pricing) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | HERAcell VIOS 160i |
| Capacity | 165 L |
| Temperature Range & Accuracy | +3 °C above ambient to 55 °C |
| Temperature Uniformity | < ±0.3 °C |
| Humidity Control | >93% RH at 37 °C |
| CO₂ Sensing | MEMS-based IR180Si infrared sensor or TC180 thermal conductivity sensor |
| O₂ Control Range (optional) | 1–21% (hypoxic) or 5–90% (hyperoxic) |
| Sterilization | Automated 180 °C dry-heat Steri-Run™ cycle |
| Interior Material | 100% electrolytic copper or stainless steel |
| Compliance | Designed for GLP/GMP environments |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | Heracell VIOS |
| Temperature Range & Accuracy | 3 °C above ambient to 55 °C, ±0.1 °C |
| Temperature Uniformity | ±0.1 °C |
| Humidity Control | >93% RH at 37 °C |
| Chamber Capacity | 165 L |
| CO₂ Control Range & Accuracy | 1–20%, ±0.1% |
| O₂ Control Range & Accuracy | 1–21% or 5–90%, ±0.1% |
| Chamber Material | Electropolished stainless steel or 100% pure copper interior |
| Sterilization | 180 °C dry-heat, 12-h cycle |
| Data Interface | USB, remote alarm contacts, optional 4–20 mA output |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic (China-manufactured) |
| Model | Thermo Scientific Heracell™ VIOS 160i CO₂ Incubator |
| Capacity | 165 L |
| Dimensions (W × D × H) | 34.6 × 25.1 × 35.4 in. (88 × 63.7 × 90 cm) |
| Humidity Control | Integrated covered water reservoir |
| Temperature Range | Ambient +3°C to 55°C |
| CO₂ Sensor Technology | Single-beam dual-wavelength infrared (IR) sensor or thermal conductivity (TC) sensor with RH compensation |
| O₂ Control Range | 1–21% (hypoxic) or 5–90% (hyperoxic) |
| Relative Humidity | >93% at 37°C |
| Air Filtration | ISO 5-class HEPA filter, full-chamber recirculation every 60 sec |
| Sterilization | 180°C Steri-Run dry-heat cycle |
| Power Requirement | 100 V, 50/60 Hz |
| Internal Chamber Material | Electropolished stainless steel (AISI 304, 18/8 grade) |
| Airflow System | THRIVE™ active airflow with internal fan |
| Door Design | Reversible outer door, adjustable perforated shelves |
| Safety | Dual independent temperature probes with overheat protection |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Shanghai, China |
| Instrument Type | Air-jacketed CO₂ Incubator |
| CO₂ Control Range & Accuracy | 1–20% (±0.1% typical deviation) |
| Capacity | 255 L (9.0 cu ft) |
| Chamber Material | Electropolished Stainless Steel or Copper-coated Stainless Steel |
| Humidity Control | Direct-heated, covered integrated water reservoir with rH compensation |
| Sterilization | Validated 180°C dry-heat cycle (12-log microbial reduction) |
| Air Filtration | ISO 5-class HEPA filter, full-chamber air exchange every 60 seconds |
| Recovery Time | All parameters restored within ≤10 min after door opening |
| Compliance | Designed to support GLP/GMP workflows |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | Heraeus BK6160 Low-Temperature |
| Internal Volume | 166 L |
| Temperature Range | 0–50 °C |
| Temperature Uniformity | ±0.8 °C |
| Temperature Stability | ±0.1 °C |
| Air Circulation Rate (with optional fan) | 150 L/h |
| Relative Humidity | >75% at 5 °C, >90% at 37 °C |
| Shelving | 2 standard / up to 7 |
| External Dimensions (W×D×H) | 744 × 920 × 725 mm |
| Internal Dimensions (W×D×H) | 607 × 470 × 585 mm |
| Refrigerant | R134a, 220 g |
| Illumination | 4000 lux (4 lamps, 70 W total) |
| Power Supply | 230 V, 50/60 Hz |
| Weight (with lighting / without) | 120 kg / 100 kg |
| Controller Options | Kelvitron K / KP / KL microprocessor-based units |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | Heraeus BK800 Low-Temperature |
| Internal Volume | 220 L |
| Temperature Range | 3–40 °C |
| Temperature Uniformity | ±1 °C |
| Temperature Deviation | ±1 °C |
| Standard/Maximum Shelves | 3 / 14 |
| External Dimensions (W×H×D) | 560 × 1480 × 570 mm |
| Internal Dimensions (W×H×D) | 467 × 1260 × 435 mm |
| Refrigerant | R600a, 20 g |
| Cooling Time (25 °C → 5 °C) | 56 min |
| Timer Range | 1–9999 min |
| Power Supply | 230 V, 50 Hz |
| Net Weight | 52 kg |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Class II Biological Safety Cabinet |
| Model | Herasafe 2030i Series |
| External Dimensions (L×W×H) | 800 × 1900 × 1536 mm |
| Internal Work Area (L×W) | 465 × 1800 mm |
| Filter Efficiency (HEPA/ULPA) | ≥99.995% at 0.3 µm |
| Airflow Control | Smart Flow+ and DAVe+ Intelligent Monitoring System |
| User Interface | Full-touch color LCD with graphical navigation |
| Connectivity | Embedded Ethernet, USB data export, remote monitoring via Thermo Connect software |
| Safety Certification | Compliant with NSF/ANSI 49, EN 12469, and ISO 14644-1 Class 5 |
| UV Lamp | Auto-intensity adjustment with motion-sensing deactivation |
| Sash Opening | 200 mm / 250 mm programmable positions |
| Construction | 316 stainless steel work surface and interior chamber |
| Lighting | Energy-efficient LED illumination |
| Ergonomic Features | Soft-grip armrests, one-touch sash operation, Smart Clean hinge-mounted sash |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Class III Biological Safety Cabinet |
| External Dimensions (L×W×H) | 1300 × 1580 × 870 mm |
| Internal Dimensions (L×W×H) | 1200 × 780 × 630 mm |
| Filter Efficiency | >99.999% for 0.3 µm particles |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | KSP |
| Instrument Type | Class II Biological Safety Cabinet |
| External Dimensions (L×W×H, mm) | 1300 × 1580 × 870 |
| Internal Dimensions (L×W×H, mm) | 1200 × 780 × 630 |
| Filter Efficiency | >99.999% for 0.3 µm particles |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | Heratherm Advanced |
| Pricing | Upon Request |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Import Status | Imported |
| Model | Heratherm Advanced Safety |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Import Status | Imported |
| Model | Heratherm Compact |
| Price | Upon Request |
| Convection Type | Mechanical (Forced Air) |
| Temperature Range | 17°C to 40°C |
| Temperature Uniformity | ±1.2°C at 37°C |
| Temperature Stability | ±0.2°C at 37°C |
| Benchtop Footprint | 0.12 m² |
| Chamber Volume | 18 L |
| Chamber Dimensions (W×H×D) | 180 × 310 × 290 mm |
| External Dimensions (W×H×D) | 260 × 415 × 470 mm |
| Standard Shelves | 2 (up to 3 optional) |
| Max Shelf Load | 2 kg per shelf |
| Power Supply | 100–240 V, 50 Hz |
| Power Consumption | 45 W (max), 14 W at 37°C |
| Net Weight | 7.2 kg |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Laboratory Incubator |
| Model | Heratherm IGS Series |
| Temperature Range | 5–75 °C |
| Chamber Volume | 75 L (IGS60), 117 L (IGS100), 194 L (IGS180) |
| Temperature Uniformity | ±0.6 °C at 37 °C |
| Temperature Stability | ±0.2 °C at 37 °C |
| Convection Type | Natural Convection |
| Interior Material | Corrosion-Resistant Stainless Steel |
| Power Supply | 230 V, 50 Hz |
| Energy Consumption at 37 °C | 21–31 W |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | IGS180 |
| Temperature Range | +5 to 75 °C |
| Temperature Uniformity | ±0.2 °C at 37 °C |
| Chamber Volume | 180 L |
| Interior Material | Corrosion-Resistant Stainless Steel (EN 1.4016) |
| Display | Large Vacuum Fluorescent Display (VFD) |
| Control Interface | Intuitive Touch-Sensitive Keypad |
| Standard Shelving | 2 Adjustable Shelves (Up to 19 Supported) |
| Max Shelf Load | 55 kg |
| Power Supply | 230 V / 50 Hz |
| Rated Power | 710 W |
| Net Weight | 65 kg |
| External Dimensions (W×H×D) | 640 × 920 × 738 mm |
| Internal Dimensions (W×H×D) | 464 × 708 × 589 mm |
| Footprint Area | 0.47 m² |
| Minimum Rear Clearance | 80 mm |
| Castor-Inclusive Height | 920 mm |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Category | Imported |
| Model | Heratherm IGS400 / IGS750 |
| Pricing | Upon Request |
| Convection Type | Natural Convection |
| Temperature Range | RT+5°C to 75°C |
| Temperature Uniformity | ±0.5°C (IGS400), ±1.3°C (IGS750) at 37°C |
| Temperature Stability | ±0.4°C at 37°C |
| Chamber Volume | 405 L (IGS400), 747 L (IGS750) |
| Internal Dimensions (W×H×D) | 544×1307×569 mm (IGS400), 1004×1307×569 mm (IGS750) |
| External Dimensions (W×H×D) | 778×1545×770 mm (IGS400), 1261×1545×770 mm (IGS750) |
| Shelving | 2 standard / up to 39 stainless steel shelves |
| Max Shelf Load | 30 kg per shelf |
| Power Supply | 230 V, 50 Hz |
| Power Consumption | 1200 W (IGS400), 1500 W (IGS750) |
| Energy Consumption at 37°C | 55 W (IGS400), 80 W (IGS750) |
| Net Weight | 145 kg (IGS400), 201 kg (IGS750) |
| Interior Material | Electropolished Stainless Steel with Radius Corners |
| Viewing Window | Full-height Double-Glazed Internal Glass Door |
| Interface | Vacuum Fluorescent Display (VFD) with Intuitive Keypad Navigation |
| Safety Features | Auto Over-Temperature Alarm (self-calibrating, no manual threshold setting required) |
| Data Monitoring | Standard RS-232/RS-485 port for external logging and validation systems |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | IMC18 |
| Temperature Range | 17–40 °C |
| Temperature Uniformity | ±0.2 °C (at 37 °C) |
| Chamber Volume | 18 L |
| Chamber Dimensions (W×H×D) | 180 × 310 × 290 mm |
| Footprint Area | 0.12 m² |
| Standard Shelving | 2 adjustable stainless-steel shelves (max. 3) |
| Max. Load per Shelf | 2 kg |
| Power Supply | 100–240 V, 50/60 Hz |
| Rated Power | 45 W |
| Net Weight | 7.2 kg |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Category | Imported Instrument |
| Model | Heratherm IMH400-S / IMH750-S |
| Convection Type | Forced-air (mechanical) |
| Temperature Range | RT + 5°C to 105°C |
| Temperature Uniformity | ±0.2°C (IMH400-S) / ±0.3°C (IMH750-S) at 37°C |
| Temperature Stability | ±0.2°C at 37°C |
| Chamber Volume | 381 L (IMH400-S) / 702 L (IMH750-S) |
| Internal Dimensions (W×H×D) | 544×1335×524 mm / 1004×1335×524 mm |
| External Dimensions (W×H×D) | 778×1545×770 mm / 1261×1545×770 mm |
| Shelving | 2 standard / up to 39 stainless-steel shelves |
| Max Shelf Load | 30 kg per shelf |
| Power Supply | 230 V, 50 Hz |
| Power Consumption (at 37°C) | 87 W / 149 W |
| Weight | 144 kg / 205 kg |
| Sterilization Mode | 140°C dry-heat cycle (6 h, validated for microbial reduction) |
| Safety Features | Dual-stage temperature alarm (high/low), door-open audible alert, independent overtemperature cut-off |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Germany |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | IMP180 |
| Temperature Range | +5 °C to +70 °C |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | IMP180 / IMP400 |
| Temperature Range | +5 °C to +70 °C |
| Brand | Thermo Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Benchtop Bioreactors |
| Price Range | USD 135,000 – 405,000 |
| Brand | Thermo Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | HyPerforma DS300 |
| Instrument Type | Top-Driven Single-Use Mixing System |
| Price Range | USD 68,000 – 136,000 (based on configuration and accessories) |
| Volume Range | 50–300 L (top-discharge), 50–200 L (bottom-discharge), 50–200 L (closed-top 3D BPC) |
