Life Science Instruments
Filter
Showing 5101–5130 of 7558 results
| Brand | Revvity |
|---|---|
| Origin | USA |
| Manufacturer | Revvity, Inc. |
| Product Type | Imported Instrument |
| Model | Cellometer Spectrum |
| Pricing | Available Upon Request |
| Brand | Revvity |
|---|---|
| Origin | USA |
| Manufacturer | Revvity, Inc. |
| Product Type | Imported Instrument |
| Model | Cellometer X2 |
| Price | Contact for Quote |
| Brand | Revvity |
|---|---|
| Origin | USA |
| Manufacturer | Revvity, Inc. |
| Product Category | Imported Instrument |
| Model | Chemagic 360 |
| Instrument Type | Magnetic Bead-Based Extraction |
| Automation Level | Dedicated Fully Automatic |
| Throughput | 1–96 samples per run |
| Sample Volume Range | 10 µL – 10 mL |
| Brand | Revvity |
|---|---|
| Origin | USA |
| Manufacturer | Revvity, Inc. |
| Product Type | Imported Instrument |
| Model | Chemagic Prime Automated High-Throughput Nucleic Acid Extraction Workstation |
| Technology | Magnetic Bead-Based Purification |
| Throughput | 2 × 96-well plates per run |
| Sample Tube Compatibility | Variable-format primary tubes (e.g., 13 mm round-bottom, 16 mm conical, 5–50 mL tubes) |
| Automation Capabilities | Integrated barcode scanning, reagent dispensing, eluate transfer, normalization, and PCR master mix assembly |
| Compliance | Designed for GLP/GMP environments with audit trail-ready operation |
| Brand | Revvity |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | EnVision |
| Functionality | Multimode |
| Automation Level | Fully Automated |
| Assay Modes | Endpoint, Kinetic, Scanning |
| Curve Fitting Options | Multiple Nonlinear Regression Models (e.g., 4PL, 5PL, Linear, Log-Log) |
| Detector Types | Photodiode & Photomultiplier Tube (PMT) |
| Wavelength Range | 200–1000 nm |
| Absorbance Range | 0–4 OD |
| Absorbance Linearity | 0–2 OD (±0.5% deviation) |
| Wavelength Switching Time | ≤12 s |
| Absorbance Precision | <0.1% CV at 1 OD |
| Brand | Revvity |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | EnVision NEXUS |
| Functionality | Multimode |
| Automation Level | Fully Automated |
| Detector Configuration | Dual-detector architecture enabling parallel high-throughput detection |
| Optical Density Range | 0–4 OD (±50 µOD accuracy) |
| Brand | Revvity |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | explorer G3 Integrated Robotic Automation System |
| Instrument Type | Magnetic Bead-Based Nucleic Acid Purification |
| Automation Level | Dedicated Fully Automated Platform |
| Brand | Revvity |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | explorer G3 |
| Pricing | Available Upon Request |
| Brand | Revvity |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (PRC) |
| Model | Hawkeye |
| Pricing | Available Upon Request |
| Brand | Revvity |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | Imported |
| Model | INV Vega |
| Instrument Type | Optical Ultrasound Imaging System |
| Animal Model | Mouse |
| Imaging Modes | B-mode, M-mode, 2D/3D/4D, Contrast-Enhanced Ultrasound (CEUS), Shear Wave Elastography (SWE) |
| Automation | Fully Motorized, Hands-Free Transducer Positioning |
| Throughput | Up to 3 mice per imaging session |
| Field of View | Wide-Field Volumetric Scanning |
| Regulatory Status | CE-marked, FDA-cleared for preclinical research use |
| Brand | Revvity |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | IVIS Lumina LT |
| Instrument Type | Optical Imaging System |
| Animal Model | Mouse |
| Imaging Modality | Bioluminescence, Fluorescence (Visible to NIR), Cerenkov Luminescence Imaging |
| Brand | Revvity |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | IVIS Lumina S5 |
| Instrument Type | Optical Imaging System |
| Animal Species | Mouse (also compatible with rat) |
| Throughput | Up to 5 mice per imaging session |
| Imaging Modalities | Bioluminescence, Fluorescence (multispectral unmixing), Cerenkov Luminescence Imaging (CLI) |
| Camera | Scientific-grade back-illuminated CCD with large field-of-view and high quantum efficiency |
| Brand | Revvity |
|---|---|
| Origin | USA |
| Manufacturer | Revvity, Inc. |
| Product Type | In Vivo Optical Imaging System |
| Model | IVIS Lumina Series III |
| Imaging Modalities | Bioluminescence, Fluorescence (Multispectral), Cerenkov Luminescence |
| Animal Compatibility | Mouse (also supports rat, cell culture, microplates) |
| Field of View Options | 2.5 × 2.5 cm to 24 × 24 cm (motorized zoom lens with 5 preset FOVs) |
| Filter Wheel Capacity | 26 positions (standard) |
| CCD Sensor | Back-illuminated, deep-cooled scientific-grade CCD (–90 °C) |
| Lens Aperture | f/0.95 |
| Filter Transmission | ≥95% (excitation & emission) |
| Spectral Analysis | Integrated Continuous Pure Spectral (CPS) algorithm |
| Brand | Revvity |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | Imported |
| Model | IVIS Lumina X5 |
| Instrument Type | Optical and X-ray Hybrid In Vivo Imaging System |
| Animal Model | Mouse (also supports rat) |
| Throughput | Up to 5 mice per imaging session |
| Imaging Modalities | Bioluminescence, Fluorescence (VIS–NIR), X-ray, Cerenkov Luminescence Imaging (CLI) |
| Spectral Unmixing | Multi-spectral fluorescence separation |
| X-ray Resolution | ≤ 50 µm effective pixel size |
| Detector | Back-illuminated, deep-cooled CCD (bioluminescence/fluorescence) |
| Brand | Revvity |
|---|---|
| Origin | USA |
| Manufacturer | Revvity, Inc. |
| Product Type | Imported |
| Model | IVIS Lumina XRMS Series III |
| Imaging Modalities | Bioluminescence, Multispectral Fluorescence, Radioisotope (Cerenkov), X-ray |
| Animal Capacity | Mice and Rats (up to 600 g) |
| Optical Filter Set | 26-position automated filter wheel |
| X-ray Detector | High-resolution, low-dose CMOS-based digital radiography system |
| Software Platform | Living Image® 4.7+ with DyCE™ module support |
| Regulatory Compliance | Designed for GLP-compliant workflows |
| Brand | Revvity |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Lumina XRMS |
| Instrument Type | Optical Imaging System |
| Animal Models | Mouse, Rat |
| Imaging Modalities | Bioluminescence, Fluorescence, Cherenkov, X-ray |
| Brand | Revvity |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | IVIS Spectrum 2 |
| Instrument Category | Optical Imaging System |
| Animal Model | Mouse |
| Field of View (FOV) | 3.9 × 3.9 cm (min) to 22.5 × 22.5 cm (max) |
| Throughput Capacity | Up to 10 mice per imaging session |
| Effective In Vivo Spatial Resolution | ≤20 µm (at minimum FOV) |
| Brand | Revvity |
|---|---|
| Origin | USA |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | Spectrum CT |
| Instrument Type | Optical & Micro-CT Hybrid Imaging System |
| Animal Model | Mouse |
| Imaging Modalities | Bioluminescence (2D/3D), Fluorescence (2D/3D), Low-Dose Micro-CT |
| Throughput | Up to 10 mice per scan |
| Camera | eXcelon-coated back-illuminated CCD |
| Software | Living Image® v4.7+ |
| Regulatory Compliance | Designed for GLP-compliant workflows, supports FDA 21 CFR Part 11 audit trail and electronic signature configurations |
| Brand | Revvity |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model(s) | IVIS Spectrum CT2, IVIS Lumina LT / Series III / XRMS Series III / S5 / X5 / Spectrum2 |
| Imaging Modality | Optical (Bioluminescence, Fluorescence, Cerenkov), X-ray, microCT, Ultrasound |
| Animal Models | Mouse, Rat, Rabbit |
| Regulatory Compliance | FDA-cleared for preclinical research use |
| Brand | Revvity |
|---|---|
| Origin | South Korea |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | IVM |
| Imaging Modality | Optical (Confocal & Two-Photon) |
| Animal Model | Mouse |
| Frame Rate | 30 fps or 50 fps @ 512 × 512 pixels |
| Spatial-Temporal Resolution | 4D motion compensation (X, Y, Z + time) |
| Tunable Laser Wavelength Range | 690–1050 nm |
| Brand | Revvity |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Category | Imported |
| Model | JANUS G3 |
| Instrument Type | NGS Library Preparation System |
| Library Prep Format | Automated, Integrated NGS Library Construction Platform |
| Configuration | Modular, User-Configurable Deck Layout |
| Software Platform | MethodBuilder™ and Interchange™ Integration Ready |
| Regulatory Support | FDA 21 CFR Part 11–compliant audit trail options available |
| Service Model | Application-Onboarding Enabled with Global Field Applications Scientists |
| Brand | Revvity |
|---|---|
| Origin | USA |
| Manufacturer | Revvity, Inc. |
| Product Type | Imported Instrument |
| Model | LabChip GX Touch HT |
| Pricing | Available Upon Request |
| Brand | Revvity |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | LabChip GXII Touch 24 |
| Instrument Classification | Ultra-Micro Nucleic Acid and Protein Analyzer |
| Analysis Time per Sample | ≤ 41 seconds |
| Throughput | Up to 384 samples per run (batch processing, 1–384 scalable) |
| Detection Principle | Microfluidic Capillary Electrophoresis (CE) with Integrated Fluorescent Detection |
| Sample Volume Requirement | 1–2 µL |
| Compatible Assay Kits | Protein Express, DNA 1K/5K/10K, RNA Nano/Pico, GlycanExpress, Charge Variant, Fragment Analyzer kits |
| Regulatory Compliance Support | 21 CFR Part 11 compliant software architecture, audit trail, electronic signatures, and secure user access control |
| Brand | Revvity |
|---|---|
| Origin | United Kingdom |
| Manufacturer | Revvity, Inc. |
| Type | Imported Instrument |
| Model | OPERA PHENIX PLUS |
| Temperature Control Range | 37–42 °C (±1 °C) |
| CO₂ Control Range | 1–10% (±0.5%) |
| Excitation Lasers | 405 nm, 488 nm, 561 nm, 640 nm (solid-state) |
| Brightfield Illumination | Near-infrared LED |
| Objective Type | High-NA water-immersion objectives |
| Imaging Throughput | ≥100,000 images per day |
| Detection | Up to four synchronized 16-bit sCMOS cameras |
| Confocal Technology | Dual Nipkow disk scanning |
| Software Platform | Acapella (with modular analysis workflows), optional Columbus cloud server and TIBCO Spotfire for advanced visualization |
| Brand | Revvity |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Operetta CLS |
| Pricing | Available upon Request |
| Brand | Revvity |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Quantum GX3 |
| Instrument Type | X-ray Computed Tomography (microCT) |
| Animal Models Supported | Mice, Rats, Guinea Pigs, Rabbits, Zebrafish, Insects, Excised Tissues & Organs |
| Spatial Resolution | ≤5 µm |
| Voxel Size | Down to 2.3 µm |
| Scan Time (Minimum) | 3.9 s |
| Field of View (FOV) | 8, 18, 36, 72, and 86 mm |
| Filter Options | Six motorized, auto-sensed filters — Al (0.5 mm, 1.0 mm), Cu (0.1 mm, 0.2 mm, 1.0 mm), Al 0.5 mm + Cu 0.06 mm |
| Gating Capabilities | Dual-phase retrospective respiratory and cardiac gating |
| Modality Integration | Native co-registration with IVIS Spectrum optical imaging systems |
| Brand | Revvity |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Sciclone G3 NGSx iQ |
| Instrument Type | Next-Generation Sequencing (NGS) Library Preparation Automation Platform |
| Regulatory Classification | Non-Medical Device |
| Form Factor | Benchtop Automation System |
| Compatibility | Vendor-Neutral NGS Library Prep Kits (Illumina®, Thermo Fisher™, IDT®, Takara Bio®, etc.) |
| Certified Validation | PKI-Validated Protocol Suite |
| Integrated Thermal Cycler | Inheco ODTC Desktop Dry Block Thermocycler |
| Robotic Arm | Twister III 5-Axis Articulated Robot |
| Liquid Handling | Dual-Channel (Sciclone G3 NGSx) + Optional 384-Channel Head (NGSx iQ HT Variant) |
| Tip Storage | 27-Position Tip Rack Carousel |
| User Interface | Graphical Touchscreen with Workflow Visualization |
| Automation Level | Unattended End-to-End DNA-to-Library Processing |
| Brand | Revvity |
|---|---|
| Origin | USA |
| Manufacturer | Revvity, Inc. |
| Product Type | Imported |
| Model | SpectrumBL |
| Imaging Modality | Bioluminescence, Chemiluminescence, Cerenkov Luminescence |
| Animal Model | Mouse (up to 10 simultaneously) |
| Spatial Resolution | ≤20 µm |
| 3D Tomographic Reconstruction | Yes |
| NIST-Traceable Absolute Radiometric Calibration | Yes |
| Software Platform | Living Image® v8.x |
| CT/MRI/PET/SPECT Data Fusion Capability | Yes |
| Upgrade Path | Compatible with IVIS® Spectrum fluorescence module |
| Brand | Revvity |
|---|---|
| Origin | Imported |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | VICTOR Kira |
| Detection Modes | Absorbance, Fluorescence, Luminescence |
| Optical System | Quad-grating Monochromator |
| Automation Level | Fully Automated |
| Software Platform | Kira Control Suite |
| Compliance | Designed for GLP/GMP environments, supports 21 CFR Part 11 audit trails |
| Brand | Revvity |
|---|---|
| Origin | Finland |
| Manufacturer | Revvity (Oy, Turku) |
| Product Type | Multimode Microplate Reader |
| Automation Level | Fully Automated |
| Assay Modes | Endpoint, Kinetic, Scanning |
| Curve Fitting Options | Linear, Log-Log, 4PL, 5PL, Quadratic, Sigmoidal |
| Detector Types | Silicon Photodiode & High-Sensitivity PMT |
| Wavelength Range | 230–1000 nm |
| Absorbance Range | 0–4 OD |
| Absorbance Linearity | ±0.01 OD (0–2 OD) |
| Wavelength Switching Time | ≤10 s |
| Absorbance Precision | <0.1% CV |