Life Science Instruments
Filter
Showing 5071–5100 of 7558 results
| Brand | RADOBIO |
|---|---|
| Model | Unishaker 70 |
| Type | CO₂-Compatible Orbital Shaker for Incubators |
| Origin | Shanghai, China |
| Drive Mechanism | Magnetic Coupling |
| Amplitude Options | 12.5 / 25 / 50 mm (3-step adjustable) |
| Speed Range | 20–350 rpm (no-load) |
| Timer Range | 0–99.9 h (0 = continuous operation) |
| Platform Dimensions | 365 × 350 mm |
| Height (Unit) | 87 mm |
| Max Load Capacity | 6 kg |
| Power Consumption | 20 W |
| Operating Environment | 4–60 °C, ≤99% RH, up to 20% CO₂ |
| Construction Material | 304 Stainless Steel |
| Controller Dimensions | 160 × 80 × 30 mm |
| Weight | 13 kg |
| Compliance | Designed for ISO 13485-aligned manufacturing environments |
| Brand | Randox Toxicology |
|---|---|
| Origin | United Kingdom |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | MultiSTAT |
| Pricing | Upon Request |
| Brand | PACIFICIMAGE |
|---|---|
| Origin | Taiwan |
| Model | RapidScan-Dual |
| Instrument Type | Chemiluminescence Gel Imaging System |
| CCD Resolution | 140 dpi |
| Bit Depth | 10-bit |
| Dynamic Range | 0–3.6 OD |
| CCD Sensor Size | 1/2-inch |
| Detection Sensitivity | 0.05 ng/mm² (for colloidal gold), 0.01 ng/mm² (for fluorescent labels) |
| Signal-to-Noise Ratio | 40 dB |
| Lens Aperture | f/6 |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CyteFinder II |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | CyteFinder II |
| Pricing | Available Upon Request |
| Brand | Raykol |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Vitae 180 NGS |
| Instrument Type | NGS Library Construction System |
| Library Construction Method | Hybridization-Based Target Enrichment (Capture) |
| Supported Plate Format | SBS-compliant 384-well plates |
| Throughput | 1–32 samples per run |
| Dimensions (W×D×H) | 1200 mm × 750 mm × 1085 mm |
| Weight | 120 kg |
| Integrated Thermal Cycler | Yes (desktop, with sealing and heated lid) |
| Onboard Modules | PCR heating block, PCR cooling block, reagent cold storage (4 °C), magnetic plate holder, plate vortexer, UV sterilization lamp (optional), HEPA filtration (positive/negative pressure, optional) |
| Brand | Raykol |
|---|---|
| Origin | Fujian, China |
| Model | Vitae Lids EP |
| Instrument Type | Benchtop |
| Function Modules | Automated Capping/Decapping, Precision Liquid Handling |
| Sample Throughput | 8 tubes per cycle (parallel capping/decapping) |
| Pipetting Range | 1–1000 µL |
| Pipetting Speed | ≤15 minutes for full capping/decapping and liquid transfer of 96 EP tubes (4-channel mode) |
| Pipetting Accuracy | ±0.1% of set volume (at ≥100 µL), compliant with ISO 8655-6 |
| Channel Configuration | 2–4 independent robotic pipetting channels |
| Deck Layout | 4 standard SBS-compliant positions for racks, plates, and reagent reservoirs |
| Optional Feature | Integrated 2D barcode scanner for sample traceability |
| Brand | Raykol |
|---|---|
| Origin | Fujian, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Vitae SPOTTER |
| Spotting Method | Contact-based (Pin-based) |
| Spot Spacing | 2.75 mm |
| Spot Volume Range | 300 nL – 10 µL |
| Pin Configuration | 1–40 solid pins (configurable) |
| Substrate Capacity | 8–24–96 standard microscope slides or microtiter plates |
| Repeatability Accuracy | ±0.05 mm |
| Compliance | Designed for GLP-compliant lab environments |
| Brand | Raykol |
|---|---|
| Origin | Fujian, China |
| Model | Vitae120 NGS-SA |
| Instrument Type | NGS Library Construction System |
| Library Construction Method | Hybridization Capture-Based |
| Supported Plate Formats | 8-well, 32-well, and 96-well PCR plates |
| Overall Function | Fully Automated NGS Library Preparation |
| Dimensions (W×D×H) | 960 × 750 × 1100 mm |
| Weight | 120 kg |
| Integrated Microfluidic Chip | None |
| Brand | Raymetech |
|---|---|
| Origin | Jiangsu, China |
| Model | MMS-200 |
| Type | Motorized, Closed-Loop Electrophysiology Micromanipulator |
| Drive Mechanism | Piezo-assisted Stepper Motor Actuation |
| Positioning Resolution | ≤50 nm (open-loop), ≤100 nm (closed-loop with integrated capacitive feedback) |
| Repeatability | ±0.1 µm |
| Maximum Load Capacity | 200 g per axis |
| Travel Range (X/Y/Z) | 25 mm × 25 mm × 20 mm |
| Control Interface | USB 2.0 + RS-422 |
| Compatibility | Standard Nikon, Olympus, Leica, and Zeiss inverted & upright microscope stages |
| Software Platform | RayControl v3.2 (Windows 10/11, 64-bit) with FDA 21 CFR Part 11–compliant audit trail module |
| Brand | Raymetech |
|---|---|
| Model | RM-M01G |
| Origin | Jiangsu, China |
| Category | Domestic |
| Distribution Type | Authorized Distributor |
| Pricing | Upon Request |
| Brand | Raymetech |
|---|---|
| Model | SCA Series |
| Origin | Jiangsu, China |
| Instrument Type | Real-time in situ single-cell biochemical analyzer |
| Sample Format | Live cells, tissue sections, in vivo preparations |
| Detection Modalities | Electrochemical, optical (fluorescence/absorbance), and hybrid dual-signal readout |
| Compliance Context | Designed for GLP-compliant research environments |
| Software Interface | Windows-based acquisition and analysis suite with timestamped metadata logging, ROI-based quantification, and kinetic trace export (CSV, HDF5) |
| Brand | Raymetech |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SCATM |
| Pricing | Available Upon Request |
| Origin | Sweden |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ReadyToProcess Column |
| Pricing | Available Upon Request |
| Brand | 908 Devices |
|---|---|
| Origin | USA |
| Distribution Type | Authorized Distributor |
| Import Status | Imported |
| Model | REBEL |
| Pricing | Available Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | refinede laser |
| Instrument Classification | Upright/Inverted Integrated Microscope |
| Price Range | USD 1–2,999 |
| Brand | Regent |
|---|---|
| Country of Origin | Canada |
| Model | WinFOLIA |
| Configuration Options | WinFOLIA Basic / Reg / Pro |
| Imaging Input | Flatbed Scanner (Desktop or Portable) or Digital Camera |
| Software Compatibility | Windows OS |
| Data Export | CSV, Excel-compatible formats via XLFolia add-on |
| Compliance | Designed for GLP-aligned plant phenotyping workflows |
| Hardware Requirements | User-supplied PC |
| Documentation | Printed & PDF User Manual |
| Brand | Regent |
|---|---|
| Origin | Canada |
| Model | WinRHIZO Tron |
| Version Options | Basic, Reg, MF (Multi-Frame) |
| Software Type | Image-Based Root Morphometric Analysis Platform |
| Compatibility | Grayscale & Low-Contrast Root Images from Minirhizotron Systems, Flatbed Scanners, or Digital Cameras |
| Data Output Format | CSV, Excel-compatible (.xls/.xlsx via XLRhizo), XML |
| Operating System | Windows 10/11 (64-bit) |
| License | Perpetual node-locked license with optional annual maintenance support |
| Brand | Regent |
|---|---|
| Origin | Canada |
| Model | WinSEEDLE |
| Hardware Required | Optional Flatbed Scanner |
| Compliance | Designed for GLP/GMP-adjacent research environments |
| Operating System | Windows 10/11 (64-bit) |
| Minimum PC Requirements | Intel Core i5, 8 GB RAM, 2 GB GPU VRAM, 10 GB free disk space |
| Origin | Canada |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | WinSEEDLE Seed and Needle Morphometric Analysis System |
| Pricing | Upon Request |
| Brand | RephiLe |
|---|---|
| Model | TriMeta |
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Instrument Type | Fully Automated Cell Culture Biochemical Analyzer |
| Detection Parameters | Glucose, Lactate, Glutamine, Ammonia, Glycerol, Total Protein (depending on cartridge) |
| Detection Channels | Multi-channel |
| Sample Types | Mammalian cells, Bacteria (e.g., E. coli), Yeast, Insect cells |
| Sample Capacity | 3 samples per run |
| Sample Volume | As low as 10 µL per test |
| Assay Time | 10 min/sample |
| Optical System | LED-based fixed-wavelength photometric array with post-dispersion optics |
| Data Storage | ≥100,000 records with audit-trail-compliant logging |
| Compliance | Supports 21 CFR Part 11, GLP/GMP data integrity requirements |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Operating Temperature | 10–40 °C |
| Relative Humidity | ≤80% RH |
| Dimensions (L×W×H) | 387 × 293 × 379 mm |
| Weight | 12 ± 1 kg |
| Origin | Canada |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TR-SES200 |
| Instrument Form Factor | Benchtop |
| Wavelength Range | 115–400 nm (tunable, VUV–UV) |
| Monochromator | VM200 vacuum monochromator, 200 mm focal length |
| Light Source | Deuterium–Argon hollow-cathode lamp (D2ArCM-L), spectral output 115–400 nm, photon flux ≈ 2 × 10¹⁵ photons/s/steradian |
| Detector | Photomultiplier tube (PMT) with spectral response 115–320 nm |
| Optical Interface | SMA-threaded lamp mount at entrance slit |
| Grating | Holographic concave grating, 1200 lines/mm, 40 × 45 mm active area, Al/MgF₂ coating optimized for 100–300 nm, F/# 4.2, input focal distance 200 mm, output focal distance 187.9 mm, deviation angle 64° |
| Scanning Mechanism | Absolute-encoded grating drive (AEGD) |
| Software Platform | LabVIEW™-based control and data acquisition suite |
| Power Supply | 220 V AC |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Model Variants | DXF40040V / DXF24040V / DXF32040V |
| Temperature Range | –10°C to –40°C |
| Internal Volume | 490 L (17.3 cu ft) |
| Vial Capacity | 32,000 × 2 mL |
| Shelf Load Capacity | 68 kg (150 lb) per Shelf |
| Insulation | 127 mm Polyurethane Foam |
| Refrigerant | R404A |
| Electrical | 230 V, 50 Hz, 12 A |
| Certifications | cULus, CE, UL, FDA Class I |
| Door Configuration | Single outer door, 5 independent inner doors (standard on DXF32040V) |
| Optional Backup | CO₂ or LN₂ cascade system |
| Data Output | Dry contacts (standard), PT100 probe (optional) |
| Warranty | Region-specific — contact local Thermo Fisher support |
| Brand | -- |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Revolution cf/ctDNA |
| Price | Upon Request |
| Brand | Revvity |
|---|---|
| Origin | USA |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | BioQulerm |
| Pricing | Upon Request |
| Brand | Revvity |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Celigo |
| Pricing | Available Upon Request |
| Brand | Revvity |
|---|---|
| Origin | USA |
| Manufacturer | Revvity, Inc. |
| Product Type | Imported Instrument |
| Model | Cellaca MX |
| Detection Time | ≤3 minutes for 24 samples |
| Cell Concentration Range | 2×10⁵ – 2×10⁷ cells/mL |
| Sample Volume | 25–100 µL per sample |
| Cell Diameter Detection Range | 5–80 µm |
| Brand | Revvity |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Cellaca PLX |
| Pricing | Available Upon Request |
| Brand | Revvity |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Cellometer Ascend |
| Detection Concentration Range | 2×10⁴ – 4×10⁷ cells/mL |
| Detectable Cell Size Range | 5–80 µm |
