| Brand | YUYANBIO |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Life Science Instrumentation |
| Model | Large-Animal Dosing Catheters |
| Price Range | USD 1,400 – 14,200 |
| Brand | YUYANBIO |
|---|---|
| Origin | USA |
| Manufacturer | YUYANBIO Inc. |
| Product Type | Animal Electrocardiography System |
| Model | YUYAN-ECG-Mouse |
| Compliance | CE, RoHS |
| Input Impedance | >10 GΩ |
| Common Mode Rejection Ratio (CMRR) | >110 dB @ 60 Hz |
| Sampling Rate | Up to 40 kS/s per channel |
| Resolution | 24-bit ADC |
| ECG Bandwidth | 0.05–500 Hz |
| EMG Bandwidth | 10–2000 Hz |
| Supported Leads | I, II, III, aVR, aVL, aVF (calculated) |
| Temperature Control Range | 32–38 °C (integrated heating pad) |
| Power Supply | USB 5 V DC (bus-powered) |
| Max Simultaneous Channels | 128 (with multi-amplifier configuration) |
| Software | LabScribe v4.x with ECG/EMG Analysis Module (FDA 21 CFR Part 11 compliant audit trail optional) |
| Brand | YUYANBIO |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | YUYANBIO Instrument Co., Ltd. |
| Model | NIBP-M1 (Single-Channel) / NIBP-MR4 (4-Channel) |
| Measurement Principle | Oscillometric + Infrared Photoplethysmography |
| Temperature-Controlled Warming Platform | Yes |
| Output Parameters | Systolic BP (SBP), Diastolic BP (DBP), Mean Arterial Pressure (MAP), Heart Rate (HR) |
| Data Export Format | Raw binary + CSV/Excel |
| Software Compliance | Audit trail-capable data logging, timestamped acquisition, user-access control |
| Channel Capacity | 1–4 simultaneous rodents (mouse or rat) |
| Animal Compatibility | Mouse (20–35 g) and Rat (200–500 g) with interchangeable tail-cuff adapters |
| Regulatory Context | Designed for preclinical GLP-compliant cardiovascular phenotyping |
| Brand | YUYANBIO |
|---|---|
| Origin | USA |
| Manufacturer Type | OEM Manufacturer |
| Product Origin | Imported |
| Model Variants | Rat-Specific Head Holder, Mouse-Specific Head Holder |
| Anesthesia Integration | Integrated Isoflurane Mask Port |
| Mounting Interface | Standard Stereo-Targeting Frame Rail Compatibility (e.g., David Kopf, Stoelting) |
| Material Options | Medical-Grade Stainless Steel, Anodized Aluminum, PEEK Polymer Components |
| Customization | Scalable Headpost Dimensions, Adjustable Ear Bar Depth & Incisor Bar Height |
| Brand | YUYANBIO |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Category | Imported Instrument |
| Model | V-100 |
| Price Range | USD 1,400 – 7,000 |
| Power Supply | 220 V AC |
| Dimensions | 24 × 16 × 10 cm |
| Weight | 1.5 kg |
| Operating Temperature | −10 °C to 60 °C |
| Relative Humidity | 20–80 % RH |
| Respiratory Rate | 1–300 breaths/min |
| Tidal Volume | 0.1–10 mL (0.1 mL step resolution) |
| I | E Ratio: 1:5 to 5:1 (0.1 step) |
| Peak Inspiratory Pressure Limit | 6 kPa |
| Airway Pressure Relief | Automatic overpressure release with user-set threshold |
| Gas Source | Ambient air or external gas supply (no high-pressure gas required) |
| Drive Mechanism | Electrically driven, electronically controlled |
| Interface | Touch-sensitive digital control panel with LED indicators (inspiration/expiration/maintained inspiration) |
| Safety Features | Real-time pressure monitoring, audible/visual alarms, fail-safe pressure limiting |
| Brand | YUYANBIO |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | YS-LED-4H / YS-LED-5H (4- or 5-Head Configurable LED Veterinary Surgical Lamp) |
| Pricing | Available Upon Request |
| Light Source | High-Efficiency White LED Array |
| Rated Power | 36 W (12-LED Head Configuration) |
| Central Illuminance | 35,000 lx |
| Color Temperature | 5500 ± 500 K |
| Service Life | ≥55,000 h |
| Input Voltage | 220 VAC, 50 Hz |
| Lamp Head Diameter | 200 mm |
| Adjustable Height Range | 1.2–1.8 m |
| Net Weight | 8 kg |
| Light Output Control | Continuous Dimming (10–100%) |
| Beam Focus | Fixed Optic with Uniform Field Distribution |
| Thermal Management | Passive Heat Sink, Zero IR/UV Emission |
| Compliance | Meets IEC 60601-2-41 (Medical Electrical Equipment – Particular Requirements for Surgical Lamps) and GB 9706.1-2020 (Chinese Equivalent) |
| Brand | Yuyi Instrument (Gongyi Yuyi) |
|---|---|
| Origin | Henan, China |
| Model | DLSB(EX) |
| Temperature Range | -20°C to -120°C |
| Reservoir Capacity | 10 L – 100 L |
| Power Supply | 220 V / 380 V, 50 Hz |
| Explosion Protection Rating | Ex d IIB T4 |
| Compliance | GB 3836.2–2000, Q/SHJFO2–2009 |
| Construction | Stainless Steel Fluid Circuit |
| Control | Digital PID Temperature Controller |
| Brand | Yuyi Instrument |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model Series | GDSZ |
| Pricing | Upon Request |
| Temperature Range | –120 °C to +200 °C |
| Volume Capacity | 5 L to 2000 L (standard models: 10–1000 L) |
| Cooling Power | 4.3 kW to 30 kW |
| Heating Power | 2.0 kW to 12.0 kW |
| Max Flow Rate | 15–70 L/min |
| Max Head | 7 m |
| Control Accuracy | ±0.1 °C (typical, with Pt100 sensor & PID algorithm) |
| Refrigerant | R410A |
| Construction Material | Cr316 stainless steel bath chamber |
| External Interface | 4″ / 6″ circulation ports |
| Power Supply | 220 V/50 Hz or 380 V/50 Hz |
| Ambient Operating Temp. | 5–30 °C |
| Safety Certifications | CE-compliant architecture |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | YXQ-LS-50G |
| Chamber Volume | 50 L |
| Max Operating Temperature | 135 °C |
| Max Working Pressure | 0.22 MPa |
| Sterilization Power | 3.1 kW |
| Drying Power | 0.8 kW |
| Voltage/Frequency | 220 V ±10% / 50 Hz ±2% |
| External Dimensions (W×D×H) | 600 × 500 × 1080 mm |
| Internal Chamber Diameter × Height | Ø350 × 525 mm |
| Basket Dimensions | Ø330 × 250 mm (2 pcs) |
| Sterilization Time Range | 4–120 min |
| Drying Time Range | 30–240 min |
| Temperature Range | 109–135 °C |
| Safety Compliance | Meets PRC Pressure Vessel Safety Technical Supervision Regulations (Article 49) |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | YXQ-LS-70A |
| Chamber Volume | 75 L |
| Max Operating Temperature | 135 °C |
| Max Operating Pressure | 0.22 MPa |
| Power Rating | 3.5 kW |
| Voltage/Frequency | 220 V ±10%, 50 Hz ±2% |
| External Dimensions (W×D×H) | 600 × 500 × 1130 mm |
| Internal Chamber Diameter × Height | Ø400 × 570 mm |
| Basket Dimensions (Ø × H × Qty) | Ø360 × 280 mm × 2 units |
| Sterilization Cycle Modes | Standard Exhaust / Pulse Exhaust / No-Exhaust |
| Control System | Microprocessor-based Intelligent Controller |
| Safety Compliance | Meets PRC Pressure Vessel Safety Technical Supervision Regulations (Article 49) |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | YXQ-LS-75G |
| Chamber Volume | 75 L |
| Maximum Operating Temperature | 135 °C |
| Maximum Operating Pressure | 0.22 MPa |
| Sterilization Power | 3.2 kW |
| Drying Power | 0.8 kW |
| Voltage/Frequency | 220 V ±10%, 50 Hz ±2% |
| External Dimensions (W×D×H) | 600 × 500 × 1150 mm |
| Internal Chamber Diameter × Height | Ø350 × 625 mm |
| Basket Dimensions (Ø × H × Qty) | Ø360 × 280 mm × 2 units |
| Sterilization Time Range | 4–120 min |
| Drying Time Range | 30–240 min |
| Temperature Range | 109–135 °C |
| Safety Compliance | Meets PVR Safety Technical Supervision Regulations Art. 49 (China) |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | YXQ-SG46-280SA |
| Chamber Volume | 18 L |
| Rated Operating Temperature | 126 °C |
| Rated Working Pressure | 0.142 MPa |
| Power Rating | 2 kW |
| Voltage/Frequency | 220 V ±10%, 50 Hz ±2% |
| Dimensions (D×H) | 390 mm × 470 mm |
| Construction Material | SUS304 Stainless Steel (Outer Shell & Inner Chamber) |
| Safety Features | Pressure-Actuated Self-Relief Valve, Dual-Scale Pressure Gauge, Auto-Locking Lid Mechanism, Expansion-Type Sealing Ring |
| Heating Mode | Dual-Fuel (Electric or Solid Fuel Compatible) |
| Lid Operation | Lever-Actuated Quick-Opening Mechanism |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | ZD-85 |
| Price | USD 860 (FOB Jiangsu) |
| Temperature Range | Ambient to 50 °C |
| Temperature Uniformity | ±1 °C |
| Oscillation Mode | Reciprocal and Orbital |
| Digital Speed Display | Yes |
| Control System | Microprocessor-based PID temperature & speed regulation |
| Chamber Type | Air-bath (non-immersive, convection-heated) |
| Power Supply | 220 V AC, 50 Hz |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | ZD-85(A) |
| Pricing | Available Upon Request |
| Temperature Range | Ambient to 50 °C |
| Temperature Uniformity | ±1 °C |
| Oscillation Mode | Reciprocating |
| Control | Digital PID Temperature Control & Mechanical Timer |
| Drive System | Stepless Speed Regulation |
| Chamber Material | Stainless Steel (304) |
| Oxygenation | Ventilation Ports for Enhanced O₂ Supply |
| Sample Holder | Universal Spring-Loaded Flask Rack |
| Brand | Zealquest AI Netherlands |
|---|---|
| Origin | Netherlands |
| Model | PLS-10R |
| Measurement Mode | Automated Continuous Monitoring |
| Leaf Chamber Type | Motorized Auto-Opening/Closing |
| Number of Chambers | Multi-channel (Configurable) |
| Chamber Area | 10 cm² (Circular, Rectangular Optional) |
| Operating Temperature | 5–50 °C |
| IP Rating | IP53 |
| Communication | Wireless (IEEE 802.15.4 / LoRaWAN compatible) |
| Data Logging Interval | Configurable from 1 s to 24 h |
| Supported External Sensors | PAR (0–2000 µmol·m⁻²·s⁻¹), Air Temp/RH, Leaf Temp (±0.15 °C), Stem Diameter Change (0.002 mm resolution), Fruit Growth (0.019–0.065 mm resolution), Sap Flow, Soil Moisture/Temperature/EC, Total Solar Radiation |
| Brand | Zealquest AI Netherlands |
|---|---|
| Origin | Netherlands |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | PTM-NG26 |
| Pricing | Upon Request |
| Brand | Zealquest |
|---|---|
| Origin | Shanghai, China |
| Model | CM100-α |
| Type | Fully Automated |
| Compliance | CE-marked for in vitro research use only |
| Sensor Technology | Integrated microelectrode impedance biosensing (xCELLigence platform–class architecture) |
| Detection Principle | Label-free, non-invasive real-time measurement of cellular impedance across gold microelectrode arrays embedded in culture plate bottom |
| Throughput | 16-well parallel monitoring per plate |
| Environmental Operation | Designed for continuous operation inside standard CO₂ incubators (37 °C, 5% CO₂, >95% RH) |
| Software Platform | Windows-based control & analysis suite with audit trail capability (21 CFR Part 11 compliant module optional) |
| Brand | Zealquest |
|---|---|
| Origin | UK (ADC BioScientific) |
| Model | LCi T |
| CO₂ Range | 0–2000 ppm (1 ppm res.) |
| H₂O Range | 0–75 mbar (0.1 mbar res.) |
| PAR Range | 0–3000 µmol·m⁻²·s⁻¹ |
| Leaf/Chamber Temp | −5 to 50 °C (±0.2 °C) |
| Flow Control | 68–340 µmol·s⁻¹ |
| Display | WQVGA color touch LCD |
| Data Storage | SD card (up to 32 GB) |
| Battery | 12 V / 2.8 Ah lead-acid (≈10 h operation) |
| Dimensions (main unit) | 240 × 125 × 140 mm |
| Weight (main unit) | 2.4 kg |
| GPS | Integrated |
| Compliance | ASTM E2912, ISO 17025-aligned measurement architecture, GLP-compliant data logging with timestamped audit trail |
| Brand | Zealquest |
|---|---|
| Origin | Israel (manufactured by OLAN Ltd.) |
| Model | PTM-50 |
| CO₂ Measurement Range | 0–1000 ppm |
| CO₂ Exchange Range | −70 to +70 µmol CO₂·m⁻²·s⁻¹ |
| H₂O Exchange & Transpiration | Continuous |
| Leaf Chamber Type | Automated Opening/Closing |
| Number of Chambers | Configurable (2, 3, or 4) |
| Chamber Area | 10 cm² |
| Measurement Cycle Time | 20 s per chamber |
| Sampling Interval | 5–120 min (user-defined) |
| Airflow Control | 0.25–0.5 LPM (adaptive) |
| PAR Sensor Range (RTH-50) | 0–2000 µmol·m⁻²·s⁻¹ |
| Operating Temperature | 10–40 °C |
| IP Rating | IP55 |
| Communication | Integrated 2.4 GHz RF + Optional 3G Module |
| Power Supply | 9–24 VDC |
| Origin | Zhejiang, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | ATP300 |
| Price Range | USD 7,000 – 14,000 |
| Reagent Bottle Capacity | 2.3 L / 3.2 L (selectable) |
| Tissue Processing Chamber Volume | 3.8 L / 5.3 L (selectable) |
| Reagent Temperature Range | 30–70 °C |
| Paraffin Bath Temperature | Ambient to 80 °C ±1 °C |
| Immersion Time Setting | 0–99 h 59 min |
| Agitation Duration | 1 min |
| Agitation Interval | 10 min |
| Operating Modes | Manual & Automatic |
| Input Power | 1500 W |
| Voltage/Frequency | 220 V, 50 Hz |
| Maximum Specimen Capacity | 100 / 200 / 300 cassettes (configurable) |
| Display | Color LCD with English UI |
| User Programs | 8 pre-programmable protocols |
| Safety Features | Overtemperature protection, power-failure recovery, full liquid evacuation control, triple-stage reagent exhaust system |
| Construction | Stainless steel processing chamber and fluid pathways |
| Brand | ZEEDO (Huasu) |
|---|---|
| Model | ES-500 |
| Origin | Zhejiang, China |
| Type | Automated Paraffin Embedding System with Integrated Cryo-Station |
| Wax Tank Capacity | 6 L |
| Temperature Control Range (Wax/Work Surface/Storage) | 0–99 °C |
| Cryo-Station Setpoint Range | Ambient to –20 °C |
| Heating Stage Range | 30–90 °C |
| Power | Main Unit 800 W, Cryo-Station 200 W, Heating Stage 500 W |
| Dimensions (Main Unit) | 650 × 647 × 465 mm |
| Net Weight (Main Unit) | 25.5 kg |
| Compliance | CE-marked per IEC 61010-1 (Laboratory Equipment Safety), Designed for GLP/GMP-Compliant Histology Labs |
| Brand | ZEEDO |
|---|---|
| Model | ES-500-2C |
| Origin | Zhejiang, China |
| Type | Paraffin Embedding Station |
| Cold Plate Temperature Range | Ambient to –20 °C |
| Hot Plate Temperature Range | 30–99 °C |
| Wax Bath Capacity | 400 wax blocks per melt |
| Cold Plate Power | 100 VA |
| Hot Plate Power | 400 VA |
| Total System Power | 1500 VA |
| Dimensions (Embedding Unit) | 600 × 650 × 450 mm (W × D × H) |
| Dimensions (Cold Plate) | 410 × 660 × 450 mm (W × D × H) |
| Weight (Embedding Unit) | 40 kg |
| Weight (Cold Plate) | 14 kg |
| Voltage | 220 V, 50 Hz |
| Operating Ambient | 5–45 °C, ≤85% RH |
| Brand | ZEEDO (Huasu) |
|---|---|
| Origin | Zhejiang, China |
| Model | ES-600 |
| Wax Reservoir Capacity | 6.5 L |
| Cold Plate Temperature Range | −20 °C to ambient |
| Working Surface Area | 830 cm² (287 mm × 205 mm + 330 mm × 73 mm) |
| Embedded Mold Heater Volume | 0.93 L |
| Cold Plate Dimensions | 365 mm × 330 mm |
| Net Weight | 40 kg (main unit), 25 kg (cold plate) |
| Power Supply | 220 V, 50 Hz |
| Total Rated Power | 800 W (main unit) + 100 VA (cold plate) |
| Brand | ZEEDO |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HS-1000 |
| Price | USD 5,500 (FOB) |
| Number of Reagent Stations | 12 (9 reagent jars + 3 paraffin wax baths) |
| Processing Time per Station | Stations 1–9: 0–99 hrs adjustable |
| Stations 10–12 | 0–24 hrs adjustable |
| Wax Bath Temperature Range | Ambient to 99 °C, digitally controlled |
| Heating Method | Dry-type internal heating |
| Single Jar Capacity | 1000 mL |
| Temperature Control Accuracy | ±2 °C |
| Agitation Frequency | 2 cycles/min |
| Power Failure Protection | >6 hrs autonomous operation without external battery backup |
| Operating Ambient Temperature | 0–40 °C |
| Input Voltage | 220 VAC, 50 Hz |
| Rated Power | 800 W |
| Dimensions (W×D×H) | 1000 × 420 × 450 mm |
| Net Weight | 80 kg |
| Origin | Zhejiang, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | HS-1000 |
| Price Range | USD 1,400–7,200 |
| Number of Reagent Stations | 12 (9 reagent tanks + 3 paraffin wax tanks) |
| Processing Time per Station | Tanks 1–9: 0–99 hours programmable |
| Tanks 10–12 | 0–24 hours programmable |
| Paraffin Temperature Range | Ambient to 99 °C adjustable |
| Heating Method | Dry-type internal heating |
| Single Tank Capacity | 1000 mL |
| Temperature Control Accuracy | ±2 °C |
| Agitation Frequency | 2 cycles/min |
| Power Failure Protection | >6 hours continuous operation without external battery backup |
| Operating Ambient Temperature | 0–40 °C |
| Input Voltage | 220 VAC, 50 Hz |
| Rated Power | 800 W |
| Dimensions (W×D×H) | 1000 × 420 × 450 mm |
| Net Weight | 80 kg |
| Brand | ZEEDO |
|---|---|
| Model | HS-1125 |
| Temperature Range | Ambient to 90 °C (adjustable) |
| Temperature Control Accuracy | ±1 °C |
| Power Supply | AC 220 V, 50 Hz / AC 110 V, 60 Hz |
| Power Consumption | 200 VA |
| Dimensions | 340 × 340 × 120 mm |
| Weight | 6 kg |
| Operating Environment | 0–40 °C |
| Brand | ZEEDO |
|---|---|
| Model | HS-1135 |
| Temperature Range | Ambient to 90°C (adjustable) |
| Temperature Control Accuracy | ±1°C |
| Power Supply | AC 220V/50Hz or AC 110V/60Hz |
| Power Consumption | 200 VA |
| Dimensions (W×D×H) | 340 × 340 × 120 mm |
| Weight | 6 kg |
| Operating Environment | 0–40°C |
| Brand | ZEEDO |
|---|---|
| Origin | Zhejiang, China |
| Model | HS-1145 |
| Automation Level | Semi-Automatic |
| Instrument Type | Non-Rotary |
| Temperature Range | Ambient to 90 °C (independently adjustable for floating, drying, and baking zones) |
| Floating Bath Volume | 135 × 185 × 80 mm |
| Dimensions (W×D×H) | 510 × 340 × 220 mm |
| Weight | 16 kg |
| Voltage | 220 V, 50 Hz |
| Power Consumption | 1000 W |
| Drying Rack Capacity | 70 glass slides (60° angled insertion) |
| Baking Chamber Capacity | 3 standard staining racks (30–40 slides each) or two 250 mL beakers for paraffin melting |
| Brand | ZEEDO |
|---|---|
| Origin | Zhejiang, China |
| Model | HS-1500 |
| Chamber Count | 9 reagent + 3 paraffin wax chambers |
| Single Chamber Volume | 1500 mL |
| Reagent Chamber Timing | 0–99 h (Chamber 1), 0–24 h (Chambers 2–9) |
| Wax Chamber Timing | 0–24 h (Chambers 10–12) |
| Temperature Range | Ambient to 99 °C |
| Tissue Protection Chamber Selection | Configurable across Chambers 1–7 |
| Drain/Drain-and-Shake Dwell Time | 10–60 s |
| Post-Entry Heating Activation | Auto-start from Chamber 2 |
| Power Supply | AC 220 V / 50 Hz or AC 110 V / 60 Hz |
| Power Consumption | 800 VA |
| Dimensions (W×D×H) | 1010 × 550 × 420 mm |
| Net Weight | 80 kg |
| Max. Throughput | ≥75 tissue specimens per cycle |
| Stirring Frequency | 0–6 rpm (adjustable) |
| Display | Large LCD with bilingual (English/Chinese) GUI and real-time animation |
| Safety | Sealed exhaust system with activated carbon filtration |
| Power Failure Recovery | >30 h backup operation with status retention and auto-resume capability |
| Cylinders | 9 reagent + 3 paraffin tanks (12 total) |
|---|---|
| Single tank capacity | 1500 mL |
| Processing time per station | 0–99 h (1st station), 0–24 h (others) |
| Temperature range | ambient to 99°C |
| Drain/hold time | 10–60 s |
| Stirring frequency | 0–6 rpm |
| Power supply | AC 220 V / 50 Hz or AC 110 V / 60 Hz |
| Power consumption | 800 VA |
| Dimensions | 1010 × 550 × 420 mm |
| Weight | 80 kg |
| Throughput | ≥75 tissue specimens per cycle |
| Safety | Sealed chamber, internal air purification, external exhaust port, dry-type internal heating, power-failure retention (>30 h) |