| Brand | Tianyan |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TY-08W |
| Price | USD 765 (based on ¥5500 at 1 USD ≈ ¥7.2) |
| Capacity | 3–400 mL |
| Timer Range | 1 s to 100 min (or continuous mode) |
| Pulsing Frequency | 3–12 strokes/sec |
| Adjustable Stroke Gap | 0–50 mm |
| Dimensions (W×D×H) | 420 × 230 × 330 mm |
| Net Weight | 19 kg |
| Operating Temperature | 0–35 °C |
| Power Supply | 220 V AC / 50 Hz, 200 W |
| Sterile Stomacher Bag Size | 17 × 30 cm |
| Display | 4.3-inch capacitive touch screen |
| Audio Alarm | Yes |
| Brand | Tianyan (Shandong Tianyan Instrument Co., Ltd.) |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | TY-JL01 |
| Measurement Principle | Constant-Heat Thermal Dissipation Method (Granier-type) |
| Probe Length | 33 mm |
| Inter-probe Spacing | 10–15 cm |
| Sensor Type | Paired T-type Thermocouples |
| Heating Element | DC-powered Constant-Current Resistive Heater |
| Data Storage | 2 GB SD Card |
| Sampling Interval | Adjustable from 1 to 99 minutes |
| Display | 320 × 160 LCD |
| Power Supply | 8.4 V Rechargeable Lithium Battery (Optional Solar Panel Integration) |
| Operating Temperature | 10–60 °C |
| Operating Humidity | 0–100 % RH |
| Material | Stainless Steel Probes with PTFE (Teflon) Coating |
| Channel Count | Single-Channel |
| Output | Instantaneous Sap Flux Density (g·m⁻²·s⁻¹ or mL·cm⁻²·h⁻¹, software-convertible) |
| Brand | Tianyan |
|---|---|
| Origin | Shandong, China |
| Model | TY-MB96L |
| Detection Method | Absorbance (Photometric) |
| Function Type | Multifunctional |
| Automation Level | Fully Automated |
| Detector Type | Photodiode-based Absorbance Detector |
| Wavelength Range | 340–750 nm |
| Precision | CV ≤ 0.2% (0–3 Abs), CV ≤ 1.0% (3–4 Abs) — Standard Measurement Mode (@405 nm) |
| Filter Wheel | 8-position, 4 standard filters included (405/450/492/630 nm), optional filters available across 340–750 nm |
| Read Range | 0–4.000 Abs |
| Resolution | 0.001 Abs |
| Linearity | ±1% (0–3.0 Abs), ±2% (3.0–4.0 Abs) @405 nm |
| Accuracy | ±1% (0–3 Abs), ±2% (3–4 Abs) @405 nm |
| Reading Speed | <6 s (96-well plate, rapid mode) |
| Memory Capacity | 200 protocols + 100,000 96-well results |
| Display | 7″ color TFT-LCD touchscreen (1280×800 px) |
| OS | Embedded Android-based firmware |
| Light Source | 6 V / 10 W halogen lamp (rated lifetime: 2000 h) |
| Interfaces | 3 × USB (for PC, printer, USB storage) |
| Dimensions (W×D×H) | 440 × 295 × 225 mm |
| Weight | 10 kg |
| Power Supply | AC 100–240 V, 50–60 Hz, 2 A |
| Brand | Tianyan |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | TY-YXL |
| Detection Principle | Photometric Colorimetry (Based on GB/T 5750.11–2023) |
| Measurement Range | 0.5–300 mg/L (low range) and 0.1–60% (high range), segmented |
| Accuracy | ≤10% error |
| Repeatability | <0.5% RSD |
| Stability | <0.5% drift over 30 min |
| Wavelength Selection | Automatic |
| Light Source | Imported Cold LED (100,000 h lifetime) |
| Display | 3.5″ Color LCD |
| Operating Environment | 0–50 °C, 0–90% RH |
| Data Storage | >80,000 records |
| Connectivity | USB Type-C, Wi-Fi, Bluetooth |
| Power | 5 V DC / 5600 mAh Li-ion battery (8 h continuous operation) |
| Dimensions | 190 × 77 × 72 mm |
| Weight | 325 g |
| Language Support | English & Simplified Chinese |
| Brand | Tianyan |
|---|---|
| Model | TY-ZT10 |
| Type | Portable Leaf Porometer for Stomatal Conductance and Transpiration Rate Measurement |
| Origin | Shandong, China |
| Key Sensors | Swiss-made digital temperature & RH sensors, Pt100 leaf temperature probe, PAR-calibrated silicon photodiode with correction filter |
| Flow Control | Precision micro-flowmeter (0.2–1.0 L/min, ±0.2% accuracy) |
| Leaf Chamber | Standard 55 × 20 mm (customizable) |
| Display | 3.5" TFT color LCD (800 × 480) |
| Battery | Rechargeable 8.4 V DC Li-ion (20 h operation, no external light source) |
| Data Storage | 16 GB internal (expandable to 32 GB) |
| Interface | USB direct data export |
| Operating Environment | 20–50 °C, 0–100% RH (non-condensing) |
| Dimensions | 260 × 260 × 130 mm |
| Weight | 3.25 kg (host only) |
| Brand | Tianyan |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | TY-ZX01 |
| Wash Head Configuration | 8-channel or 12-channel selectable |
| Number of Wash Fluid Channels | 8 or 12 |
| Wash Cycles Adjustable | 1–99 |
| Residual Volume per Well | ≤1 µL |
| Wash Volume Range | 50–3000 µL (adjustable in 10-µL increments) |
| Dispensing Accuracy | ≤2.0% |
| Soak Time | 0–24 h |
| Shake Duration | 0–600 s |
| Wash Time per Cycle | 0.1–9.9 s |
| Programmable Protocols Stored | ≥100 user-defined methods |
| Dual Aspiration Mode | Enabled |
| Bottom-Flush Function | Integrated |
| Pressure-Adjustable Wash Fluid Delivery | Supported |
| Plate Compatibility | Flat-bottom, U-bottom, V-bottom microplates |
| Optional Feature | Overflow sensor for waste/residual liquid detection |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Benchtop Temperature-Controlled Orbital Shaker |
| Model | TP671 |
| Timing Range | 0–99 min (±10 s accuracy) for oscillation/standby cycles |
| Temperature Range | Ambient to 100 °C |
| Oscillation Frequency | 275 ± 3 rpm |
| Oscillation Amplitude | 35 mm |
| Platform Configuration | 8 × 100 mL syringes + 4 × 250 mL Erlenmeyer flasks |
| Control System | Dual-CPU microprocessor with self-diagnostic firmware |
| Display | LCD with icon-free tactile keypad |
| Safety | Overtemperature cutoff, real-time thermal fault detection |
| Heating Uniformity | ≤±0.5 °C at setpoint (measured at center of platform, steady-state) |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Tissue-3 |
| Price Range | USD 42,000 – 70,000 |
| Product Type | Microphysiological System (MPS) / Organ-on-a-Chip Platform |
| Laser Source | None (Optical Imaging–Based, Non-Flow Cytometric) |
| Detection Channels | 1 (Integrated Brightfield/Fluorescence Imaging Channel) |
| Spatial Resolution | ≤5 µm (at 20× objective) |
| Fluorescence Sensitivity | ≥10⁴ molecules per cell (FITC-equivalent) |
| Real-Time Imaging Frame Rate | Up to 30 fps (full-field, 1024 × 768) |
| On-Chip Perfusion Flow Rate | 0.1–100 µL/min, Pulsatile or Steady-State |
| Chip Format | Standard Microscope Slide Dimensions (75 × 25 × 1.0 mm) |
| Cell Culture Duration Support | ≥28 days under continuous perfusion |
| Brand | TissueGnostics |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | incyton flox |
| Pricing | Upon Request |
| Brand | TissueGnostics |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | StrataQuest 8.0 |
| Pricing | Available Upon Request |
| Brand | TissueGnostics |
|---|---|
| Country of Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | TissueFAXS 8.0 |
| Pricing | Available Upon Request |
| Brand | TissueGnostics |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | TISSUEFAXS PLUS |
| Price Range | USD 270,000 – 410,000 |
| Brand | TissueGnostics |
|---|---|
| Country of Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | TISSUEFAXS Q+ |
| Price Range | USD 420,000 – 700,000 |
| Brand | TissueGnostics |
|---|---|
| Country of Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported Instrument |
| Model | TISSUEFAXS SL SLIDE LOADER |
| Price Range | USD 420,000 – 700,000 |
| Brand | TissueGnostics |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | TISSUEFAXS SPECTRA |
| Price Range | USD 420,000 – 700,000 |
| Brand | Tissuse |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | IMOLA |
| Pricing | Available Upon Request |
| Brand | Titan |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (PRC-Made) |
| Model | BLT-470 |
| Instrument Type | Portable (Handheld) |
| Wavelength Type | Single Wavelength |
| Blue Light Peak Emission | 470 nm |
| LED Array | 144 high-intensity blue LEDs |
| Excitation Filter Dimensions | 180 × 110 mm |
| Power Consumption | 24 W |
| Brand | Titan |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | DPM-4 |
| Instrument Type | Multi-Plate Orbital Shaker |
| Timer Range | 1 min – 8 h |
| Oscillation Frequency | 500–1200 rpm |
| Orbit Diameter | 3 mm |
| Number of Shaking Platforms | 4 |
| Brand | Titan |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | Domestic (China) |
| Model | LM-80D |
| Instrument Category | Other Oscillators / Shakers |
| Timer Range | 1 min – 23 h 59 min |
| Oscillation Speed | 20 – 80 rpm |
| Brand | Titan |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | MPM-2 |
| Instrument Type | General-Purpose Orbital Microplate Shaker |
| Timer Range | 1 min – 8 h |
| Oscillation Frequency | 100–1200 rpm |
| Orbit Diameter | 4 mm |
| Number of Shaking Platforms | 2 |
| Brand | Titan |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | MS-4 |
| Instrument Type | Microplate Shaker |
| Timer Range | 0–9 h 59 min |
| Oscillation Frequency | 200–1500 rpm |
| Oscillation Amplitude | 3 mm |
| Temperature Control | Ambient Only |
| Platform Quantity | 1 |
| Brand | Titan |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Full-Temperature Incubator Shaker |
| Timer Range | 0–99 h 59 min |
| Oscillation Frequency | 200–1500 rpm |
| Orbital Amplitude | 2 mm |
| Temperature Control Range | Ambient +5°C to 80°C |
| Platform Quantity | 1 |
| Brand | Titan |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (China-made) |
| Model | RM-80D |
| Instrument Type | Orbital Shaker |
| Timer Range | 1 min – 23 h 59 min |
| Oscillation Speed | 20 – 80 rpm |
| Brand | Titan |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Gradient PCR Thermal Cycler |
| Sample Capacity | 96-well plate (0.2 mL format) |
| Heating Rate | 5 °C/s |
| Temperature Accuracy | ±0.1 °C at 55 °C |
| Well-to-Well Temperature Uniformity | ±0.3 °C at 55 °C |
| Brand | Titan |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | Domestic (China) |
| Model | TOS-100 |
| Instrument Category | Orbital Shaker |
| Timer Range | 1 min – 99 h 59 min |
| Oscillation Speed | 50 – 300 rpm |
| Orbit Diameter | 10 mm |
| Temperature Control | Ambient-only (No Heating/Cooling) |
| Platform Quantity | 1 |
| Brand | Titan |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | TOS-200 |
| Instrument Category | Orbital Shaker |
| Timer Range | 1 min – 99 h 59 min |
| Oscillation Speed | 50–250 rpm |
| Orbit Diameter | 20 mm |
| Platform Quantity | 1 |
| Brand | Titan |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | VM-T1 |
| Instrument Category | Other Oscillators / Shakers |
| Timer Range | 0–999 minutes |
| Oscillation Speed | 200–3000 rpm |
| Orbital Amplitude | 4.5 mm |
| Temperature Control | Ambient-only (No Heating/Cooling) |
| Platform Quantity | 1 |
| Origin | Europe |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TL200/PMT |
| Price | Upon Request |
| Brand | TMAXTREE |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | ARTP |
| Instrument Type | Atmospheric-Pressure Room-Temperature Plasma Mutagenesis System |
| Function | Microbial and Cellular Sample Treatment |
| Discharge Technology | Atmospheric-pressure uniform glow discharge with stable, homogeneous plasma jet |
| Working Gas | Helium ≥99.999% purity |
| Mutagenesis Mode | Atmospheric-pressure room-temperature plasma mutagenesis |
| Gas Flow Control Range | 0–15 SLM (Standard Liters per Minute) |
| Gas Flow Accuracy | ±1.0% F.S. |
| Sample Treatment Distance | 2 mm |
| Plasma Jet Temperature | ≤37 °C |
| Total Power Consumption | ≤500 W |
| Sample Throughput | 6-position automated sequential treatment and collection |
| Applicable Organisms | Prokaryotes (e.g., bacteria, actinomycetes), eukaryotes (e.g., yeasts, molds, algae, higher fungi), plant cells (pollen, seeds, embryonic tissues), and animal zygotes/embryos |
| Regulatory Compliance | Designed for GLP-compliant strain improvement workflows |
| Brand | TMAXTREE |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic |
| Model | ARTP-M |
| Instrument Type | Atmospheric-Pressure Plasma Mutagenesis System |
| Function | Biological Sample Treatment |
| Discharge Technology | Atmospheric-Pressure Uniform Glow Discharge with Stable, Homogeneous Plasma Jet |
| Working Gas | Helium ≥99.999% purity |
| Mutagenesis Mode | Ambient-Pressure, Room-Temperature Plasma Exposure |
| Gas Flow Control Range | 0–15 SLM (Standard Liters per Minute) |
| Gas Flow Accuracy | ±1.0% F.S. |
| Sample-to-Nozzle Distance | 2 mm |
| Plasma Jet Temperature | ≤37 °C |
| Max. Power Consumption | 300 W |
| Cooling Requirement | External Chilled Circulation System |
| Sample Handling | Single-Sample Processing Mode |
| Applicable Organisms | Prokaryotes (e.g., bacteria, actinomycetes), Eukaryotes (e.g., yeasts, molds, microalgae, higher fungi), Plant Cells (pollen, seeds, embryonic tissues), Animal Embryos & Larvae |