| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | BioSpec® 3T |
| Field Strength | 3 Tesla |
| Instrument Type | Preclinical Magnetic Resonance Imaging (MRI) and Magnetic Resonance Spectroscopy (MRS) System |
| Bore Diameter | 180 mm |
| RF Coil Options | >30 dedicated coils for mouse/rat head, brain, heart, body, multinuclear, and functional applications |
| Gradient Strength | Up to 900 mT/m |
| Gradient Linearity | ±3.5% within 50 mm DSV |
| Shim System | 6 high-order shim coils + high-power shim power supplies (up to 3750 Hz/cm² in XZ/YZ) |
| Magnetic Field Homogeneity | ±0.1 ppm within 50 mm DSV |
| Magnet Hold Time | >4 hours after power loss or coolant interruption |
| Software Platform | ParaVision® with >1000 optimized pulse sequences including IntraGate™, UTE, ZTE, and non-ECG-triggered cardiac imaging |
| Multi-Modal Compatibility | PET, optical imaging, CT |
| Regulatory Compliance | Designed for GLP-compliant preclinical research environments |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ICON |
| Instrument Type | Magnetic Resonance Imaging (MRI) System |
| Field Strength | 1 Tesla |
| Target Subjects | Rodents (Mice & Rats) |
| Magnet Type | Cryogen-Free Permanent Magnet (Aspect Magnet Technologies) |
| Core Platform | AVANCE III Spectrometer Architecture |
| Software Suite | ParaVision® 360 |
| Application Domain | Preclinical Molecular Imaging, Longitudinal In Vivo Studies, Educational MRI Training |
| Operating Cost Profile | Low (No Liquid Helium or Cryogen Refills Required) |
| Footprint | Benchtop (≤ 1.2 m × 0.8 m × 1.4 m) |
| Regulatory Compliance | CE Marked, ISO 13485–Compliant Design, FDA 510(k)-Cleared for Preclinical Use (K220927) |
| Brand | Bruker |
|---|---|
| Origin | France |
| Model | minispec LF50 / LF90 |
| Application | In vivo quantitative analysis of fat mass, lean body mass, and free fluid in live mice and rats |
| Measurement Principle | Pulsed low-field TD-NMR (1H) at 0.047 T (2 MHz) |
| Sample Orientation | Vertical or horizontal magnet configuration |
| Analysis Time | ≤ 120 s per animal |
| Animal Safety | Non-invasive, no ionizing radiation, no anesthesia required |
| Regulatory Context | Compliant with GLP-aligned data integrity requirements |
| Brand | Bruker |
|---|---|
| Origin | France |
| Model | minispec LF50/mq7.5 |
| Measurement Principle | Time-Domain Nuclear Magnetic Resonance (TD-NMR) |
| Operating Frequency | 7.5 MHz |
| Maximum Sample Mass | 85 g (mice) |
| Sample Tube Inner Diameter | 49 mm |
| System Footprint | ~70 cm × 110 cm |
| Regulatory Compliance | CE Marked, ISO 9001:2000 Certified |
| Software Platform | Microsoft Windows with Microsoft Access Database |
| Data Acquisition Interface | Graphical User Interface (GUI) optimized for lab operation |
| Calibration | User-performed with reference standards or biological samples |
| Animal State During Measurement | Conscious, non-anesthetized, unrestrained |
| Measurement Duration | Typically < 3 minutes per animal |
| Environmental Suitability | Designed for rodent housing facility integration (dust-resistant enclosure, shielded magnet housing) |
| Brand | Bruker |
|---|---|
| Origin | France |
| Model | minispec LF90II |
| Instrument Type | In Vivo Rodent (Mouse/Rat) Body Composition Analyzer |
| Operating Frequency | 6.2 MHz |
| Measurement Time | < 120 s per animal |
| Sample Handling | Non-invasive, anesthesia-free, restraint-only in dedicated cylindrical holder |
| Compliance | Designed for GLP-compliant preclinical research environments |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MPI |
| Price Range | USD 420,000 – 700,000 |
| Instrument Type | Nuclear Imaging |
| Brand | Bruker |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PET/MR 3T |
| Imaging Modality | Integrated Positron Emission Tomography / Magnetic Resonance Imaging |
| Energy Resolution | 17% FWHM at 511 keV |
| Spatial Resolution (PET) | <0.7 mm (NEMA NU-4) |
| Spatial Resolution (MRI) | ≤1.2 mm isotropic (with CryoProbe™) |
| Scan Speed | Up to 10 min per dynamic PET frame (variable by protocol) |
| Field of View (FOV) | 80 mm (PET transaxial), 148 mm (MRI transaxial), 285 mm (whole-body MRI longitudinal) |
| Animal Capacity | 1 subject per scan (mouse or rat) |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SKYSCAN 1178 |
| Instrument Type | Tomographic Imaging |
| X-ray Source | Sealed Metal-Ceramic Tube (20–65 kV, 40 W) |
| Detector | Digital X-ray Camera (1280 × 1024 pixels, 12-bit) |
| Scan Volume | Ø82 mm × 82 mm (single scan), up to 200 mm full-length |
| Voxel Size (isotropic) | 80 µm (1024³) or 160 µm (512³) |
| Minimum Scan Time | <45 s (160 µm) |
| Full-body mouse scan | 3 min 20 s (80 µm) |
| Reconstruction Time | 45 s (160 µm) |
| Animal Handling | Carbon-fiber mouse/rat bed on interchangeable mounting platform |
| Physiological Monitoring | Real-time respiration & ECG gating, motion detection |
| Radiation Safety | Surface dose rate <1 µSv/h during operation |
| Software Suite | NRecon, DataViewer, CTAn, CTVol, MorphoGraphX |
| Brand | Bruker |
|---|---|
| Origin | Belgium |
| Model | SkyScan 1272 |
| Detector | 16 MP sCMOS |
| Voxel Size | down to 0.4 µm |
| X-ray Source | 20–100 kV adjustable |
| Field of View | up to Ø25 mm |
| Auto-Sampler | optional 16-position |
| In Situ Stages | compression (4400 N), tension (440 N), heating (+80 °C), cooling (−30 °C below ambient) |
| Software | NRecon, CTAnalyser, DataViewer, CTVox (GPU-accelerated 3D.SUITE) |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | SkyScan 1276 |
| Imaging Modality | X-ray micro-computed tomography (micro-CT) |
| Spatial Resolution (nominal) | ≤2.8 µm |
| Scan Modes | Step-and-shoot, continuous gantry rotation with slip-ring interface |
| Scan Time per Reconstruction | as low as 3.9 s |
| Reconstructed Slice Count per Scan | >1600 slices |
| Max Image Matrix Size | 8000 × 8000 pixels |
| X-ray Source Voltage Range | 20–100 kV adjustable |
| Automatic Filter Changer | 6-position |
| Dose Reduction Technology | Beam-shaping collimator (patented by Bruker microCT) |
| Physiological Monitoring Integration | Respiratory gating, ECG synchronization, temperature stabilization, motion detection |
| Animal Handling | Interchangeable mouse/rat beds with integrated anesthesia mask and sensor interface |
| Real-time Dose Monitoring | On-screen dosimetry derived from projection image analysis |
| Reconstruction Acceleration | GPU-accelerated algorithms + InstaRecon® layered reconstruction (≥10× faster than conventional FBP) |
| Software Compliance | GLP-compliant software suite with audit trail, user access control, and electronic signature support |
| Data Export & Remote Viewing | Direct export to iOS/Android devices via dedicated viewer app |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SkyScan1278 |
| Instrument Type | Tomographic Imaging System |
| Energy Resolution | 17% |
| Spatial Resolution | 50 µm |
| Scan Time | 7.2 s per full-body mouse scan |
| Field of View Diameter | 80 mm |
| Scan Length | 200 mm |
| Sample Capacity | 1 animal per scan |
| X-ray Source | Adjustable 20–65 kV microfocus tube with patented beam shaping optics |
| Detector | High-sensitivity CMOS flat-panel detector |
| Dose Level | <6 mGy for whole-body murine scan |
| Physiological Gating | Integrated respiratory, ECG, temperature, and motion monitoring |
| Data Output Formats | DICOM, TIFF, JPG, BMP, PNG, AVI |
| Software Compliance | GLP-compliant acquisition and reconstruction suite |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | SPR #64 |
| Instrument Type | Surface Plasmon Resonance (SPR) |
| Channel Configuration | 8-Channel Orthogonal Flow Cell with 64 Sensor Spots |
| Fluidic Flexibility | Up to 8 Simultaneous Buffer Streams |
| Automation Interface | RESTful API & Robotic Integration Ready |
| Sample Format Support | 96-well & 384-well Microplates, Reagent Reservoirs, External Cooling-Compatible Stage |
| Cleaning Mechanism | Integrated Dual-Prism Cartridge with Auto-Clean Protocol |
| Data Output Format | Open HDF5, CSV, and JSON |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ECM 399 |
| Price Range | USD $13,500 – $40,500 (FOB) |
| Product Type | Electroporation System for Cell Transfection and Transformation |
| Brand | BTX |
|---|---|
| Origin | USA |
| Model | ECM 830 |
| High Voltage Range | 505–3000 V |
| Low Voltage Range | 5–500 V |
| Pulse Duration | 10 ms–10 s |
| Capacitance | 111 µF |
| Resistance | 25 Ω |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | Gemini SC2 |
| Waveforms | Square Wave & Exponential Decay Wave |
| Voltage Range (LV) | 5–500 V (1 V step), 505–3000 V (5 V step) |
| Voltage Range (HV) | 10–500 V (5 V step), 510–3000 V (10 V step) |
| Pulse Duration (Square, LV) | 10 µs–999 µs (1 µs), 1 ms–999 ms (1 ms) |
| Pulse Duration (Square, HV) | 10 µs–600 µs (1 µs) |
| Pulse Duration (Exponential, LV) | 1.25 ms–3.275 s (1.25 ms) |
| Pulse Duration (Exponential, HV) | 0.5 ms–50 ms (0.5 ms) |
| Pulse Number (Square) | 1–10 (LV), 1–3 (HV) |
| Pulse Number (Exponential) | 1–12 (R < 100 Ω), 1–24 (R > 100 Ω) |
| Pulse Interval | 0.1–10 s (Square), 5–30 s (Exponential) |
| Capacitance (LV) | 3775 µF (fixed) |
| Capacitance (HV) | 85 µF (fixed) |
| Capacitance (Exponential, LV) | 25–3275 µF (25 µF step) |
| Capacitance (Exponential, HV) | 10, 25, 50 µF (selectable) |
| Resistance Measurement Range | 25–1575 Ω (25 Ω step, LV) |
| Display | Touchscreen Interface |
| Preloaded Protocols | Yes |
| Arc Suppression | Active |
| Short-Circuit Protection | Integrated |
| Compliance | CE, RoHS, FDA-listed device (Class II) |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | Gemini X2 |
| Waveforms | Square Wave & Exponential Decay Wave |
| Voltage Range (LV) | 5–500 V (1 V step), 505–3000 V (5 V step) |
| Voltage Range (HV) | 505–3000 V (5 V step) |
| Pulse Duration (Square, LV) | 10 µs–999 µs (1 µs), 1 ms–999 ms (1 ms) |
| Pulse Duration (Square, HV) | 10 µs–600 µs (1 µs) |
| Pulse Duration (Exponential, LV) | 1 ms–5.158 s |
| Pulse Duration (Exponential, HV) | 0.5 ms–133.875 ms |
| Pulse Count (Square) | 1–10 (LV), 1–3 (HV) |
| Pulse Count (Exponential) | 1–12 (R < 100 Ω), 1–24 (R > 100 Ω) |
| Inter-Pulse Interval | 0.1–10 s (Square), 5–30 s (Exponential) |
| Capacitance (LV) | 3775 µF |
| Capacitance (HV) | 85 µF |
| Capacitance (Exponential, LV) | 25–3275 µF (25 µF step) |
| Capacitance (Exponential, HV) | 10, 25, 35, 50, 60, 75, 85 µF |
| Resistance Measurement Range | 25–1575 Ω (25 Ω step, LV), 50–1575 Ω (25 Ω step, HV) |
| Electrode Compatibility | BTX standard cuvettes, in vivo electrodes, MOS 96-well electroporation plates, footswitch |
| Software Control | USB and Ethernet interface for protocol download, storage, and remote execution |
| Safety Features | Arc suppression, short-circuit protection, real-time impedance monitoring |
| Brand | BTX |
|---|---|
| Origin | USA |
| Model | BTX Hybrimune |
| Capacity Options | 2 mL (microscope-compatible transparent chamber) & 9 mL fusion chambers |
| AC Pre-Fusion Pulse | 0.2–2.0 MHz (0.2 MHz step), 5–75 V (0.1 V step), 0–60 s (1 s step), non-sinusoidal ramp-up waveform |
| AC Post-Fusion Pulse | same frequency/voltage range, ramp-down waveform |
| DC Fusion Pulse | square wave, 100–1000 V (5 V step), 20–1000 µs (10 µs step), 0–10 pulses, 0.125–10 s inter-pulse interval |
| Cycles | 1–10 sets |
| Operating Temperature | 20–30 °C |
| Compliance | Designed for GLP-compliant lab environments |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 454 |
| Pricing | Available Upon Request |
| Brand | BTX |
|---|---|
| Origin | USA |
| Model | BTX Model 524 |
| Electrode Type | Reusable tweezer-style in vivo electroporation electrode |
| Electrode Disk Diameter Options | 7 mm (Model 520) or 10 mm (Model 523) |
| Adjustable Inter-Electrode Gap | <1 mm to >20 mm |
| Compatible Pulse Generators | BTX ECM 830, ECM 630, ECM T820, ECM 2001 |
| Electrode Material | Stainless steel |
| Sterilization Method | Ethanol or ethylene oxide |
| Connection | BTX Model 524 Cable |
| Compliance | Designed for GLP-compliant preclinical research workflows |
| Brand | BW |
|---|---|
| Origin | Canada |
| Model | GAXT |
| Detection Gases | H₂S, CO, O₂, SO₂, Cl₂, HCN, NO₂, NH₃, PH₃, EtO, ClO₂, O₃, NO |
| Alarm Types | Visual (bright wide-angle LED), Vibration, Audible (95 dB) |
| Calibration | Auto-calibration compatible with BW MicroDock II |
| Ingress Protection | IP66/IP67 |
| Certifications | ATEX Ex ia IIC T4, IECEx Ex ia IIC T4X, UL Class I Div 1 Groups A–D / Class II Div 1 Groups E–G, ABS, CE |
| Dimensions | 2.8 × 5.0 × 9.5 cm |
| Weight | 82 g |
| Battery | Replaceable 3V lithium |
| Data Logging | Internal event and exposure history |
| Display | Backlit LCD with real-time concentration readout |
| Languages | English, French, German, Spanish, Portuguese |
| Environmental Compliance | EMC Directive 89/336/EEC |
| Safety Standards | Meets requirements for OSHA, NIOSH, and ISO 4031 for portable gas monitoring |
| Brand | BW |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GAMIC-5 |
| Pricing | Upon Request |
| Dimensions | 14.5 × 7.4 × 3.8 cm |
| Weight | 370 g |
| Alarm | Visual (LED), Vibration, Audible (95 dB) |
| Alarm Types | Low, High, STEL, TWA, OL (Over Limit) |
| Startup Self-Test | Sensor integrity, circuit continuity, battery status |
| Power | Rechargeable Li-ion (continuous operation) |
| Pump | Optional integrated sampling pump |
| Data Logging | Configurable interval |
| Calibration | Compatible with BW MicroDock II automated docking station |
| Certifications | ATEX II 1G T4*, IECEx Ex ia IIC T4*, Class I Div. 1 Groups A/B/C/D, ABS Certified (toxic & PID modes), IP65/IP67 |
| Sensor Types | Electrochemical (toxic gases/O₂), Catalytic Bead (LEL), PID (10.6 eV lamp, VOC mode), NDIR (CO₂, IR mode) |
| Operating Modes | Toxic Gas Mode / PID Mode / IR Mode |
| Password Protection | Yes |
| Environmental Compliance | EMC Directive 89/336/EEC |
| Brand | — |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | BXP-65S |
| Price | Upon Request |
| Temperature Range | RT+5 °C to 100 °C |
| Temperature Uniformity (at 60 °C) | ±0.6 °C |
| Temperature Fluctuation (at 60 °C) | ±0.3 °C |
| 30-Second Recovery Time (at 60 °C) | 14 min |
| Heating Time to 60 °C | 16 min |
| Rated Power | 0.55 kW |
| Inner Chamber Dimensions (W×D×H) | 410 × 350 × 450 mm |
| External Dimensions (W×D×H) | 575 × 608 × 637 mm |
| Standard Shelves | 2 (max. 5) |
| Stackable | Yes (up to 2 units) |
| Interface Ports | 2 × RS-485, 1 × USB |
| Origin | Sichuan, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | C2008 |
| Pricing | Upon Request |
| Brand | CARE |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | IBTC-100S |
| Stretch Rate | 1–15% strain per cycle |
| Stretch Frequency | 0.2–5 Hz |
| Waveform | Sinusoidal |
| Static & Dynamic Stretch Modes | Yes |
| Custom Strain Profile Support | Yes |
| Microscopy-Compatible Substrate | Transparent bottom for live-cell imaging |
| Strain Uniformity Across Culture Area | ≥95% |
| Measurement Uncertainty | <1% (engineering strain output) |
| Brand | CARE |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | IBTC-10S |
| Quotation | Upon Request |
| Stretching Frequency Range | 0.2–5 Hz |
| Elongation Range | 1–15% |
| Brand | BioLife Solutions (formerly Custom Biogenic Systems) |
|---|---|
| Origin | USA |
| Model | 2101 Series |
| Voltage/Frequency | 230 V, 50/60 Hz |
| Dimensions (D×H×W) | 648 mm × 743 mm × 484 mm |
| Temperature Uniformity | ±0.1 °C |
| Temperature Accuracy | ±0.1 °C |
| Control Range | +50 °C to −180 °C |
| Cooling Rate | 0.01–99 °C/min |
| Heating Rate | up to 20 °C/min |
| Chamber Volume | 28 L |
| Software | Series 2101 Control Software (Windows OS) |
| Brand | CYSEA |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Dimensions | 40 × 31 × 20 cm |
| Operating Temperature Range | 15–30°C (50–86°F) |
| Brand | CEM |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | CleavagePro |
| Amino Acid Addition | Automated |
| Reagent Addition | Automated |
| Synthesis Scale | 1–10 μmol |
| Reaction Vessel Count | 48 |
| Reaction Vessel Capacity Options | 15 mL / 50 mL |
| Brand | CEM |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | Discover Hydrolysis |
| Quotation | Upon Request |
| Reaction Method | Single-Mode Microwave |
| Reaction Time | 10 minutes |
| Sample Volume per Vial | 300 µL (up to 10 vials) |
| Temperature Control Range | 0–300 °C |
| Hydrolysis Scale | 1 pmol – 1 fmol |
| Vial Format | HPLC-compatible glass autosampler vials (100–300 µL) |
| Temperature Sensor | In-situ fiber-optic probe (RT–300 °C) |
| Vacuum Level | 25 mmHg |
| Stirring Mechanism | Magnetic stirring |
| Atmosphere Control | Alternating vacuum/N₂ purging via integrated valve panel |
| Brand | CEM |
|---|---|
| Origin | USA |
| Model | DISCOVER SPS |
| Reaction Mode | Single-Mode Microwave |
| Max. Reaction Volume | 300 mL |
| Sample Throughput | 14 samples per run |
| Temperature Range | 0–300 °C |
| Typical Enzymolysis Temperature | 55 °C |
| Temperature Accuracy | ±1 °C |
| Temperature Sensing | In-situ Fiber-Optic Probe |
| Mixing | Magnetic Stirring |
| Cooling | 5 PSI Forced Air |
| Sample Vial Format | 1.5 mL Microcentrifuge Tubes |
| Minimum Sample Volume | 30 µL |
| Hydrolysis Time (Typical) | 10–15 min |
| Enzyme-to-Protein Ratio Range | 1:100 to 1:10 |