| Brand | Beiyu Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | BCL-100 |
| Power Source | Rechargeable Lithium-ion Battery (20 h runtime) |
| Weight | 5 kg |
| Filtration Membrane | 0.45 µm Hydrophilic Membrane (Aqueous Phase) |
| Sample/Bottle Capacity | 600 mL |
| Vacuum Pump | Corrosion-Resistant Imported Diaphragm Pump |
| Display | LCD Battery Level Indicator |
| Bottle Material | Metal-Ion-Free Polymer Compliant with Chinese National Standards (e.g., HJ 489–2009, HJ 490–2009) |
| Membrane Replacement | Tool-Free Quick-Release Mechanism |
| Brand | BelektroniG |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Line | BTC Series |
| Power Output | ±27 V DC, max. 10 A |
| Dimensions | 226 × 172 × 91 mm (L × W × H) |
| Temperature Uniformity | 0.1 °C / 0.01 °C / 0.001 °C (selectable per sensor configuration) |
| Temperature Control Range | −200 °C to +800 °C |
| Temperature Measurement Resolution | 0.001 °C (with calibrated Pt1000 or thermocouple input) |
| Sampling Rate | 10 Hz |
| Fan Supply | 0–12 V DC, max. 300 mA |
| Weight | 3.2 kg |
| Brand | Benchmark |
|---|---|
| Origin | USA |
| Model | INCU-SHAKER 10L |
| Timer Range | 1 min – 48 h (or continuous operation) |
| Oscillation Speed | 30–300 rpm |
| Orbit Diameter | 19 mm |
| Temperature Range | Ambient +5°C to 60°C (H1010) |
| Temperature Uniformity | ±0.25°C |
| Temperature Accuracy | ±0.1°C |
| Temperature Increment | 0.1°C |
| Speed Increment | 1 rpm |
| Platform Size | 45 × 45 cm |
| Dimensions (W×D×H) | H1010: 51 × 65 × 47 cm |
| H1012 | 51 × 79 × 56 cm |
| Weight | H1010: 55 kg |
| H1012 | 78 kg |
| Power Supply | 120/230 V, 50–60 Hz |
| Input Power | 450 W (H1010), 950 W (H1012) |
| Number of Shaking Platforms | 1 |
| Brand | Benchmark |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | INCU-SHAKER Mini CO₂ |
| Instrument Category | Incubated Orbital Shaker |
| Timer Range | 1 min to 48 h (or continuous operation) |
| Oscillation Speed | 30–300 rpm |
| Orbit Diameter | 19 mm |
| Temperature Range | Ambient +5°C to 60°C |
| Shelf Quantity | 1 stainless steel adjustable shelf |
| CO₂ Range | 0–20% (0.1% increment) |
| CO₂ Accuracy | ±0.1% |
| Temp Uniformity | ±0.5°C |
| Temp Stability | ±0.1°C at 37°C |
| Platform Dimensions | 23.5 × 29 cm |
| Interior Chamber Dimensions (W×D×H) | 33.5 × 26 × 39.2 cm |
| Power Supply | 115/230 V, 50–60 Hz, 350 W |
| Weight | 40.1 kg |
| Max Load Capacity | Up to twelve 125 mL flasks, eight 250 mL flasks, five 500 mL flasks, or two 1000 mL flasks |
| Brand | Benchmark |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | INCU-SHAKER Mini |
| Instrument Category | Incubated Orbital Shaker |
| Timer Range | 1 min – 48 h (or continuous operation) |
| Oscillation Speed | 30–300 rpm |
| Orbit Diameter | 19 mm |
| Temperature Range | Ambient +5°C to 70°C |
| Number of Shaking Platforms | 1 |
| Temperature Resolution | 0.1°C |
| Temperature Uniformity | ±0.25°C |
| Temperature Accuracy | ±0.1°C |
| Speed Resolution | 1 rpm |
| Platform Dimensions | 23.5 × 29 cm |
| External Dimensions (W×D×H) | 28 × 41 × 33 cm |
| Open Lid Height | 63 cm |
| Weight | 11.5 kg |
| Power Supply | 115/230 V, 50–60 Hz, 300 W |
| Brand | Benchmark |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | MultiBlock |
| Function Type | Multi-Block, Gradient-Capable, Touchscreen-Controlled Thermal Cycler |
| Heating/Cooling System | Peltier-based |
| Display | 10-inch Full-Color Adjustable-Tilt Touchscreen |
| Communication Ports | USB 2.0, LAN |
| Temperature Range | 4°C to 99.9°C |
| Max Heating Rate | 7.5°C/sec |
| Max Cooling Rate | 6.0°C/sec |
| Temperature Uniformity | ≤ ±0.2°C at 90°C |
| Temperature Accuracy | ≤ ±0.2°C at 90°C |
| Ramp Rate Adjustment | 0.1–5.0°C/sec |
| Gradient Function | Yes (8-zone independent gradient per block) |
| Gradient Accuracy | ±0.1°C |
| Gradient Range | 30–99.9°C |
| Heated Lid | Yes |
| Lid Temperature Range | 30–112°C |
| Software Features | Password-Protected User Accounts, Protocol Transfer via USB, Audit-Trail-Ready Program Storage, On-Device Protocol Wizard |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 737 / 737R |
| Quotation | Available upon Request |
| Temperature Range (737) | Ambient +5°C to 80°C |
| Temperature Range (737R) | 4°C to 80°C |
| Temperature Control | Microprocessor-based, non-programmable |
| Temperature Display | Digital LED, 0.1°C resolution |
| Temperature Accuracy | ±0.15°C |
| Temperature Uniformity | ±0.2°C across chamber |
| Speed Range | 20–420 rpm (configurable beyond standard range) |
| Orbit Diameter | 20 mm |
| Drive Mechanism | Dynamically balanced three-axis eccentric drive |
| Safety Interlock | Motor stops automatically when chamber door is opened |
| Chamber Material | Powder-coated stainless steel |
| Shelf Compatibility | Stackable, optional shelving kits available |
| Platform Dimensions (W×D) | 520 × 451 mm |
| Chamber Dimensions (W×D×H) | 615 × 520 × 595 mm (737), 615 × 520 × 755 mm (737R) |
| External Dimensions (W×D×H) | 845 × 600 × 850 mm (737), 845 × 600 × 1010 mm (737R) |
| Net Weight | 113 kg (737), 124 kg (737R) |
| Shipping Weight | 164 kg (737), 173 kg (737R) |
| Flask Capacity Support | 50–6000 mL |
| Max Flask Load per Platform | 72 × 50 mL, 42 × 125 mL, 25 × 250 mL, 16 × 500 mL, 9 × 1000 mL, 6 × 2000 mL, 4 × 2800 mL, 4 × 4000 mL, 2 × 6000 mL |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | BenchPro 4100 |
| Pricing | Available Upon Request |
| Brand | BENDER |
|---|---|
| Origin | Sichuan, China |
| Model | YDH-25-216F |
| Capacity | 25 L |
| Liquid Nitrogen Adsorption Capacity | 10 L |
| Static Evaporation Rate | 0.89 L/day |
| Holding Time | 11 days |
| Cryovial Capacity | 500 × 25-well boxes or 550 × 100-well boxes |
| Blood Bag Capacity | 250 × 250 mL or 125 × 500 mL |
| Neck Diameter | 216 mm |
| Total Height | 741 mm |
| Outer Diameter | 396 mm |
| Empty Weight | 12.5 kg |
| Full Weight | 31.8 kg |
| Material | High-Strength Anodized Aluminum Alloy |
| Compliance | GB/T 5458–2012 |
| Warranty | 1-year comprehensive, 5-year vacuum integrity |
| Brand | BENDER |
|---|---|
| Origin | Sichuan, China |
| Model | YDH-4-125 |
| Capacity | 4 L |
| Neck Diameter | 125 mm |
| Total Height | 521 mm |
| Outer Diameter | 300 mm |
| Empty Weight | 7 kg |
| Full Weight | 9.6 kg |
| Static Evaporation Rate | 0.45 L/day |
| Holding Time | 4 days |
| Vacuum Insulation Layer Warranty | 5 years |
| Standard Compliance | GB/T 5458–2012 |
| Sample Compatibility | Cryovials, 25- and 100-compartment cryoboxes, 50 mL blood bags (up to 6 units), standard blood bag racks |
| Standard Accessories | 1 x inner canister (lift bucket), 1 x neck plug, 1 x locking lid |
| Optional Accessories | Temperature alarm module, certified IATA-compliant aviation transport case |
| Brand | Mindray |
|---|---|
| Origin | Shanghai, China |
| Model | BeneFusion eSP/eVP/eDS Vet |
| Device Type | Veterinary Infusion and Syringe Pump System with Integrated Data Acquisition |
| Regulatory Classification | Class II Medical Device (China NMPA), CE-marked for veterinary use |
| Compliance | IEC 60601-1, IEC 60601-2-24, ISO 13485, EN 62304 |
| Brand | BEOnChip |
|---|---|
| Origin | Spain |
| Model | BE-DOUBLEFLOW |
| Chip Format | Standard Microscope Slide (75 × 25 mm) |
| Membrane Options | Polycarbonate or PET with customizable pore sizes (0.4 µm, 1.0 µm, 3.0 µm, 8.0 µm) |
| Fluidic Interface | Integrated Luer-lock inlets/outlets |
| Optical Compatibility | Fully transparent, high-clarity cyclic olefin copolymer (COC) body |
| Sterility | Gamma-irradiated, individually packaged |
| Compatibility | Compatible with Fluigent pressure-based systems, syringe pumps, inverted & upright microscopes (including phase contrast, fluorescence, and time-lapse imaging) |
| Brand | BeonChip |
|---|---|
| Origin | Spain |
| Model | BE-FLOW |
| Chip Format | Standard Microscope Slide-Sized (75.0 × 25.0 × 1.0 mm) |
| Channel Architecture | Dual Independent Parallel Channels |
| Flow Control | Independent Pressure-Driven Shear Regulation per Channel |
| Cell Culture Compatibility | 2D Monolayer & 3D Hydrogel-Embedded Cultures |
| Surface Treatment | Non-Fouling, Low-Adsorption Polymer Coating |
| Sterility | Pre-Sterilized (EO or Gamma, upon request) |
| Regulatory Status | For Research Use Only (RUO) |
| Brand | BEOnChip |
|---|---|
| Origin | Spain |
| Model | BE-GRADIENT |
| Chip Format | Standard microscope slide footprint (75 × 25 mm) |
| Chamber Architecture | One central 3D culture chamber + three integrated microchannels (two lateral perfusion channels + one auxiliary channel) |
| Substrate Material | Optical-grade, plasma-bonded cyclic olefin copolymer (COC) |
| Transparency Range | 200–1100 nm (fully compatible with brightfield, phase contrast, DIC, and fluorescence microscopy) |
| Sterility | Pre-sterilized via ethylene oxide (EO) gas |
| Surface Treatment | Non-fouling, cell-adhesion-neutral coating (no extracellular matrix pre-coating required) |
| Fluidic Interface | Standard Luer-lock connectors (1/4"-28 thread) |
| Compatibility | Compatible with syringe pumps (e.g., Harvard Apparatus PHD Ultra), pressure-driven systems (e.g., Elveflow OB1), and automated perfusion platforms |
| Brand | BEOnChip |
|---|---|
| Origin | Spain |
| Model | BE-TRANSFLOW |
| Form Factor | Standard Microscope Slide (75 × 25 mm) |
| Membrane | Integrated Porous Polycarbonate or PET Membrane (Typical Pore Sizes: 0.4 µm, 3.0 µm, 8.0 µm — Configurable) |
| Chamber Configuration | Dual Independent Culture Wells Connected via Sub-membrane Microchannel Network |
| Optical Compatibility | Fully Transparent, High-Clarity Polymer (Cyclic Olefin Copolymer, COC) |
| Fluidic Interface | Standard Luer Lock Inlets/Outlets (Compatible with Fluigent, Elveflow, Harvard Apparatus, and Other Pressure/Peristaltic/Syringe Pump Systems) |
| Sterility | Pre-sterilized (EO or Gamma), Ready-to-Use |
| Regulatory Status | For Research Use Only (RUO) |
| Brand | Berthold |
|---|---|
| Origin | Germany |
| Model | LB983 |
| Imaging Modality | Bioluminescence & Fluorescence Optical Imaging |
| Camera Type | Cooled Slow-Scan CCD |
| Cooling Method | Peltier (−90 °C typical operating temperature) |
| Spectral Range | 400–900 nm |
| Pixel Resolution | Up to 3.2 MP (NC320 front-illuminated) / 1.0 MP (NC100 back-illuminated) |
| Field of View Adjustment | Motorized vertical camera positioning (35–725 mm travel) |
| Maximum Sample Height | 260 mm |
| Dark Box Light Tightness | < 0.001 lux internal ambient light leakage |
| Calibration | Integrated optical flat-field and intensity reference standard for quantitative cross-experiment comparability |
| PET Integration | MACU interface module with dedicated software synchronization for small-animal PET co-registration |
| Software Platform | IndiGO v5.x with FDA 21 CFR Part 11-compliant audit trail, GLP/GMP-ready reporting modules |
| Brand | Berthold |
|---|---|
| Origin | Germany |
| Model | Mithras² LB 943 |
| Function Type | Multimode |
| Automation Level | Semi-Automatic |
| Assay Methods | Endpoint, Kinetic, Long-Term Kinetic, Well-Scanning |
| Curve Fitting | Linear, Non-Linear, Logarithmic |
| Detector Types | PMT (3), Photodiode (1) |
| Wavelength Range | 200–850 nm (standard), up to 1000 nm (optional) |
| Absorbance Range | 0–4 OD |
| Absorbance Linearity | <0.1% |
| Wavelength Accuracy | ±1 nm |
| Precision (CV) | <0.3% |
| Luminescence Sensitivity | <2 amol ATP/well (96-well, Glow) |
| Fluorescence Sensitivity | <0.1 fmol Fluorescein/well (96-well) |
| TRF Sensitivity | <2 amol Europium/well (96-well) |
| HTRF® Dynamic Range | >600% ΔF |
| FP Sensitivity | <4 mP |
| AlphaScreen® Detection Limit | <12 ng |
| Crosstalk | <5×10⁻⁶ |
| Excitation Sources | Halogen lamp, Xenon flash lamp, Laser (optional) |
| Monochromator | Dual grating (excitation & emission), bandwidth 4–22 nm adjustable in 1 nm steps, optical density >10⁶ |
| Reading Modes | Top & Bottom Read (all modalities) |
| Plate Formats | 6–1536-well microplates, Petri dishes, Terasaki plates |
| Temperature Control | Ambient +5 °C to 45 °C (optional) |
| Certifications | CE, UL, CSA |
| Power Supply | 110–240 V AC, 50/60 Hz |
| Brand | Berthold |
|---|---|
| Origin | Germany |
| Model | NightOwl II LB 983 |
| CCD Sensor | Back-illuminated, deep-depletion CCD, 1 MP (13 × 13 µm pixels) |
| Cooling | −90 °C (Peltier) |
| Full Well Capacity | 100,000 e⁻ |
| Spectral Range | 350–1050 nm |
| Quantum Efficiency | >90% @ 500–700 nm |
| Lens | f/0.95, C-mount, 25 mm |
| Field of View | Adjustable 35–725 mm |
| Exposure Time | 30 ms to >120 h |
| Sample Height Capacity | 312 mm |
| Binning | 1×1 to 16×16 |
| Filter Wheel | 6-position, 340–1100 nm |
| Excitation Source | ≥75 W halogen lamp (340–750 nm) |
| X-ray Module | Optional integrated micro-radiography |
| Anesthesia Interface | 5-animal isoflurane chamber with flow control |
| Dimensions (H×W×D) | 122 × 60 × 40 cm |
| Weight | 85 kg |
| Compliance | CE-marked, GLP/GMP-ready architecture, FDA 21 CFR Part 11–compatible software audit trail |
| Brand | Berthold |
|---|---|
| Origin | Germany |
| Model | LB 985N |
| Resolution | 1024 × 1024 |
| Pixel Size | 13.3 µm |
| Sensor Type | Cooled EMCCD |
| Cooling Temperature | −20 °C (absolute) |
| Quantum Efficiency Peak | 500–750 nm |
| Imaging Modes | Bioluminescence, Chemiluminescence, Fluorescence (with GFP filter set) |
| Dual-Camera Configuration | Top-view + side-view |
| Stage | Motorized X-Y stage with 360° rotational capability |
| Environmental Control | Integrated temperature and humidity regulation |
| Software | indiGO™ control and analysis suite |
| Brand | Berthold |
|---|---|
| Origin | Germany |
| Model | LB985 |
| Imaging Modality | Optical Bioluminescence & Fluorescence Imaging |
| Detector | 12-Megapixel Cooled EMCCD (–20 °C operating temperature) |
| Quantum Efficiency Peak | 500–750 nm |
| Imaging Modes | Bioluminescence/Chemiluminescence (LULu), Ultra-Low-Noise CCD (IKLu), Dual-Mode Bioluminescence + Fluorescence (LUFlu) |
| Illumination | LED-based Simulated Sunlight (Top Illumination), Side Illumination Module |
| Sample Stage | Motorized X-Y Translation + 360° Rotational Platform |
| Environmental Control | Integrated Temperature & Humidity Regulation |
| Software | indiGO™ v6.x with Hardware Synchronization, Audit Trail, and GLP-Compliant Data Archiving |
| Brand | Berthold |
|---|---|
| Origin | Germany |
| Model | Tristar² S LB 942 |
| Detection Modes | Absorbance, Luminescence, Fluorescence (top/bottom read), Time-Resolved Fluorescence (TRF), Homogeneous Time-Resolved Fluorescence (HTRF®), Fluorescence Polarization (FP), Bioluminescence Resonance Energy Transfer (BRET/BRET²/NanoBRET), Fluorescence Resonance Energy Transfer (FRET) |
| Detector | Low-noise, high-speed single-photon counting PMT and photodiode |
| Absorbance Range | 0–4 OD |
| Absorbance Linearity | <0.1% |
| Wavelength Accuracy | ±1 nm |
| Wavelength Scanning Speed | 0.1 s per data point |
| Absorbance Precision | <0.3% |
| Luminescence Sensitivity | <6 amol ATP/well (96-well, glow assay) |
| Fluorescence Sensitivity | <0.2 fmol fluorescein/well (96-well) |
| TRF Sensitivity | <5 amol europium/well |
| Dynamic Range | >6 decades |
| Well-to-Well Crosstalk | <5×10⁻⁶ |
| Injector Options | Up to 3 programmable injectors (10–100 µL, 1 µL increment) |
| Temperature Control | Ambient +5 °C to 45 °C (optional) with cooled PMT |
| Compatible Plate Formats | 6–384-well microplates, Eppendorf µPlate GO.5, Terasaki plates, Petri dishes |
| Excitation Source | Xenon flash lamp |
| Monochromator | Dual grating (4–22 nm bandwidth, 1 nm increment) for absorbance/fluorescence excitation |
| Filter Capacity | Up to 30 high-transmission (>80%) interference filters (excitation & emission) |
| Software | ICE™ (Instrument Control & Evaluation), compliant with 21 CFR Part 11 audit trail and electronic signature requirements |
| Certifications | CE, RoHS, ISO 13485–aligned design |
| Operating Environment | 15–35 °C, 10–85% RH (non-condensing) |
| Storage | 0–40 °C |
| Power Supply | 110–240 V AC, 50/60 Hz |
| [Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | BFY-2 |
| Instrument Type | Vertical Shaker for Liquid-Liquid Extraction |
| Timer Range | 0–99 h |
| Oscillation Frequency | 0–350 rpm |
| Oscillation Amplitude | 0–60 mm |
| Tilt Angle Adjustment | 0–20° (graduated scale) |
| Platform Capacity | 4 independent shaker plates |
| Sample Positions per Plate | 8–10 |
| Clamp Type | Elastic, infinitely adjustable integrated clamp |
| Safety Shield | Integrated transparent polycarbonate guard] |
| Origin | Zhejiang, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | BHC-1000IIA2 |
| Price | USD 4,200 (FOB) |
| Cabinet Class | Class II, Type A2 |
| External Dimensions (L×W×H) | 1200 × 780 × 1950 mm |
| Internal Work Area (L×W×H) | 1000 × 700 × 680 mm |
| HEPA Filter Efficiency | ≥99.99% @ 0.3 µm (EN 1822-1 |
| Inflow Velocity | 0.35 ± 0.025 m/s |
| Downflow Velocity (Center) | 0.26 ± 0.025 m/s |
| Downflow Velocity (Rear) | 0.27 ± 0.025 m/s |
| Side Airflow Velocity | 0.38 ± 0.025 m/s |
| Air Leakage Rate | ≤1×10⁻⁶ m/s @ 500 Pa |
| Sound Pressure Level | ≤62 dB(A) |
| Vibration Amplitude (Half-Peak) | ≤5 µm |
| Illumination | ≥300 lux |
| Power Supply | AC 220 V, 50 Hz, Single Phase |
| Power Consumption | 0.6 kW |
| Net Weight | <200 kg |
| HEPA Filter Size & Qty | 995 × 600 × 38 mm × 1 |
| Fluorescent Lamp / UV Lamp | 20 W × 1 / 20 W × 1 |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | BHC-1300IIA/B3 |
| Instrument Class | Class II A2 Biological Safety Cabinet (30% Exhaust) |
| External Dimensions (L×W×H) | 1500 × 815 × 2270 mm |
| Internal Work Area (L×W×H) | 1300 × 600 × 640 mm |
| Filter Efficiency | HEPA ≥99.995% @ 0.3 µm |
| Downflow Velocity (Center) | 0.27 m/s |
| Inflow Velocity | ≥0.5 m/s |
| Noise Level | ≤58 dB(A) |
| Power Consumption | 2.1 kW |
| Weight | 340 kg |
| Lighting | 30 W × 2 Fluorescent Lamps + 30 W UV Lamp |
| Illumination | ≥650 lx |
| Airflow Configuration | Left/Right/Top Exhaust Options |
| Certified Protection Levels | Personnel Protection (≤10 CFU/plate, impact sampler), Product Protection (≤5 CFU/plate), Cross-Contamination Protection (≤2 CFU/plate) |
| Compliance | Meets ISO 14644-1 Class 5 (ISO Class 5, formerly “100”), EN 12469:2000, and GB/T 16292–16294 (Chinese Pharmacopoeia & GMP requirements) |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic (China-Made) |
| Model | BHC-1300IIA2 |
| Cabinet Type | Class II, Type A2 (30% Exhaust / 70% Recirculated) |
| External Dimensions (L×W×H) | 1500 × 815 × 2270 mm |
| Internal Work Area Dimensions (L×W×H) | 1300 × 600 × 640 mm |
| Filter Efficiency | HEPA ≥99.995% @ 0.3 µm |
| Downflow Velocity | 0.33 m/s |
| Inflow Velocity | 0.55 m/s |
| Noise Level | ≤58 dB(A) |
| Lighting Intensity | ≥650 lux |
| Power Supply | AC 220 V, 50 Hz |
| Total Power Consumption | 2.0 kW (including dedicated GFCI outlets) |
| Net Weight | 340 kg |
| Lighting | Two 30 W fluorescent lamps + one 20 W UV lamp |
| Exhaust Options | Left, right, or top discharge |
| User Capacity | Dual-operator configuration |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Category | Class II, Type B2 (Total Exhaust) Biosafety Cabinet |
| Model | BHC-1300IIB2 |
| External Dimensions (L×W×H) | 1525 × 830 × 2300 mm |
| Internal Work Area Dimensions (L×W×H) | 1300 × 600 × 640 mm |
| Filter Efficiency | HEPA ≥99.995% @ 0.3 µm |
| Downflow Velocity | 0.30 m/s |
| Inflow Velocity | 0.55 m/s |
| Noise Level | ≤58 dB(A) |
| Power Supply | AC 220 V, 1Φ, 50 Hz |
| Total Power Consumption | 2.0 kW (including auxiliary socket) |
| Weight | 340 kg |
| Lighting | 2 × 36 W fluorescent lamps |
| UV Lamp | 1 × 30 W |
| Illuminance | ≥650 lx |
| Duct Port Diameter | Ø250 mm |
| Safety Certification Compliance | EN 12469:2000, NSF/ANSI 49-2022, GB 50346-2011 |
| Brand | Hamamatsu Photonics (BHP) |
|---|---|
| Model | BHP6602 |
| Type | Compact Planar Gamma Camera for Small-Animal and Human Thyroid/Parathyroid Imaging |
| Origin | Hebei, China |
| Regulatory Approvals | NMPA (ex-SFDA) Certified, FDA 510(k) Cleared |
| Field of View (FOV) | ≥150 mm |
| Energy Range | 70–364 keV (optimized for ⁹⁹ᵐTc, ¹²³I, ¹³¹I) |
| Intrinsic Spatial Resolution | ≤3.8 mm FWHM |
| Maximum Count Rate | ≥150 kcps |
| Intrinsic Uniformity | ≤±3.0% integral, ≤±0.5% differential |
| Intrinsic Spatial Linearity Error | ≤0.4 mm |
| Dimensions (L×W×H) | 1192 × 804 × 1268 mm (low position) / 1468 mm (high position) |
| Weight | 147 kg |
| PACS Integration | Yes |
| Software Interface | Full Chinese GUI with quantitative analysis modules for thyroid area/weight, renal time-activity curves, gated blood pool, and static bone imaging |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BI-2500 |
| Detection Range | <100 Da, KD = 10⁻³ M (1 mM) to 10⁻¹² M (1 pM), angular resolution <10⁻⁴° |
| Sample Channels | 3 |
| Injection Volume | >50 µL |
| Analysis Time Scale | milliseconds to hours (kinetically resolved) |
| Temperature Control | Ambient only |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BI-4500 |
| Price Range | USD 70,000 – 140,000 |
| Sample Flow Channels | 5 |
| Light Source | Dual 670 nm LEDs |
| Detection Speed | 4 ms |
| Incident Angle Range | 40–47° (gas phase), 67–81° (liquid phase) |
| Sensitivity | < 0.06 RU RMS (0.01 mdeg RMS) |
| Drift | ≤ 1 RU/hour (≤ 0.17 mdeg/hour) under ambient temperature drift < 1 °C/hour |
| Interface | USB 3.0 |
| Dimensions | 355 × 250 × 515 mm (W × H × D) |
| Weight | 11.5 kg |
| Brand | BI/Biosensing Instrument |
|---|---|
| Origin | USA |
| Model | BI-4500 |
| Detection Principle | Surface Plasmon Resonance (SPR) |
| Optical Wavelength | 670 nm |
| Angular Resolution | <0.01 mDeg RMS |
| Sensitivity | <0.06 RU RMS |
| Flow Channels | 5 independent microfluidic channels |
| Flow Rate Range | 1.0–250 µL/min |
| Minimum Analyte MW | 100 Da |
| Injection Volume | >50 µL |
| Injection Time | <0.2 s |
| Liquid-Phase Incident Angle Range | 67–81° |
| Gas-Phase Incident Angle Range (optional) | 40–47° |
| BI-DirectFlow™ Technology | Yes |
| Software Compliance | FDA 21 CFR Part 11 ready (audit trail, electronic signature support), GLP/GMP-compatible data handling |