| Brand | Haier Biomedical |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | HMP-260E |
| Price | Upon Request |
| Temperature Range (Dry) | 0–70°C |
| Temperature Range (Humidified) | 10–60°C |
| Temperature Fluctuation | ±0.3°C |
| Humidity Range | 50–95% RH |
| Humidity Fluctuation | ±5% RH |
| Capacity | 260 L |
| External Dimensions | 640 × 629 × 1650 mm |
| Internal Dimensions | 520 × 568 × 1000 mm |
| Brand | Haier Biomedical |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | HYY.G002 |
| Instrument Category | Dry-Phase Thawing System |
| Data Interface | USB and RS232 |
| Display | High-Resolution LED Touchscreen |
| Data Export | CSV-formatted thawing logs with timestamp, temperature profile, and cycle ID |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DW-60W156 |
| Pricing | Upon Request |
| Brand | Hamamatsu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | C13299 |
| Pricing | Upon Request |
| Brand | Hamilton |
|---|---|
| Origin | USA |
| Model | GFGJ-81000 |
| Capacity | 10–500 µL |
| Needle Gauge Options | 26s (OD 0.47 mm, ID 0.13 mm), 22s, 22 (OD 0.72 mm, ID 0.41 mm), 25 |
| Needle Length | 2 in (51 mm) |
| Volume per Inch (26s) | 0.26 µL/in |
| Volume per Inch (22) | 3.35 µL/in |
| Type | N-type (fixed needle, gas-tight plunger seal) |
| Brand | Hanbon |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | ACC450 |
| Price Range | USD 140,000 – 210,000 |
| Purification Principle | Axial Compression Chromatography |
| Detector Types | UV, pH, Conductivity |
| Detection Capabilities | Integrated multi-channel analog/digital signal acquisition for real-time UV absorbance (280 nm/254 nm), pH (0–14), and conductivity (0–200 mS/cm) |
| Brand | Hansatech (distributed by SUSS, Germany) |
|---|---|
| Origin | United Kingdom |
| Model | M-PEA-1 |
| Power Supply | 12 V DC, 1 A |
| Operating Temperature | 0–40 °C |
| Dimensions | 230 × 190 × 85 mm |
| Weight | 1.4 kg |
| Data Interface | USB 2.0 |
| Sampling Rate | 10 µs |
| A/D Resolution | 16-bit |
| Actinic Light Source | High-intensity red LED (peak 625 nm, FWHM 20 nm), up to 5000 µmol m⁻² s⁻¹ |
| Far-Red Light Source | High-brightness LED with long-pass filter, >1000 µmol m⁻² s⁻¹ |
| P700⁺ Measurement | Modulated 820 nm LED (1–100% intensity, 1% step) |
| Fluorescence Detection | Low-noise, fast-response PIN photodiode with 730 nm ±15 nm bandpass filter |
| P700⁺ Detection | Low-noise, fast-response PIN photodiode with dedicated bandpass filtering |
| Optical Sealing | Quartz-glass encapsulation for dust, moisture, and contamination resistance |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | Hanuo-UVI |
| Gel Drying Area | 150 × 100 mm |
| Excitation Wavelength | 470 nm (Blue LED) |
| Illumination Method | Side-mounted LED matrix |
| Dimensions (L×W×H) | 220 × 210 × 40 mm |
| Weight | 1.5 kg |
| Power Supply | DC 24 V, 1 A |
| LED Lifetime | ≥50,000 hours |
| Compatible Fluorophores | GeneGreen, GelRed, GelGreen, SYBR Green I, SYBR Safe, GoldView, SYBR Gold, SYPRO Ruby, SYPRO Orange, SYPRO Tangerine, eGFP, Cy2, FITC, Ethidium Bromide (EB) |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | HN-1200Y |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power Output | 1000 W (adjustable 1–100% duty cycle) |
| Operating Frequency Range | 19–23 kHz |
| Temperature Control Range | −5 °C to +100 °C |
| Maximum Sample Volume | 1000 mL |
| Single-Sample Processing Capacity | 1 unit per cycle |
| Standard Probe Diameter | Φ20 mm |
| Optional Probes | Φ10 mm, Φ15 mm, Φ22 mm |
| Brand | Hanuo |
|---|---|
| Model | HN-6020SE |
| Origin | Shanghai, China |
| Application | Research-grade |
| Temperature Range | +5°C to 60°C (above ambient) |
| Temperature Accuracy | ≤ ±0.5°C |
| Temperature Uniformity | ≤ ±0.5°C |
| Display Resolution | 0.1°C |
| Timer Range | 1 min – 99 h 59 min |
| Oscillation Speed | 50–300 rpm |
| Horizontal Amplitude | 20 mm |
| Platform Dimensions | 230 × 230 mm |
| Chamber Height | 182 mm |
| Max Load Capacity | 4.0 kg |
| Heating Time (to 60°C) | ≤ 15 min |
| Power Input | AC 220 V, 50–60 Hz |
| Rated Power | 350 W |
| Fuse | 250 V, 3 A, Φ5 × 20 mm |
| Dimensions (W × D × H) | 420 × 320 × 338 mm |
| Weight | Not specified |
| Safety Features | Dual (hardware + software) overtemperature protection, lid-open auto-pause, power-loss auto-resume, built-in temperature calibration |
| Motor Type | Brushless DC motor |
| Noise Level | Low |
| Compliance | Designed for GLP-aligned research environments |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HNUV-II |
| UV Wavelength | 254 nm (optional 312 nm / 365 nm lamps) |
| Exposure Time Range | 0–999.9 min |
| Exposure Energy Range | 0–99.99 J |
| UV Source | Five 10 W low-pressure mercury lamps |
| Power Consumption | 60 W |
| Chamber Material | Stainless steel |
| Display | Touch-enabled Chinese LCD interface |
| Memory | Non-volatile storage for up to 9 user-defined time/energy protocols |
| Operating Environment | 5–35 °C, ≤80% RH, 220 V AC ±20%, 50 Hz |
| Compliance | Designed for routine molecular biology workflows under GLP-aligned lab practices |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | HNX-2500P |
| Instrument Type | Benchtop Microplate Centrifuge |
| Function | Standard Microplate Centrifugation |
| Maximum RCF | 797 × g |
| Maximum Speed | 2500 rpm |
| Sample Capacity | 2 × 96-well PCR plates (or deep-well plates) |
| Operating Noise | ≤55 dB(A) |
| Speed Range | 500–2500 rpm |
| RCF Range | 32–797 × g |
| Timer Range | 1–30 min |
| Multi-step Programming | Up to 5 segments |
| Cycle Repetition | Up to 99 cycles |
| Auto Restart After Power Failure | Yes |
| Imbalance Detection | Real-time electronic monitoring with audible/visual alarm |
| Drive System | Brushless DC motor |
| Power Input | AC 220 V, 50–60 Hz |
| Max. Power Consumption | 150 W |
| Dimensions (W×D×H) | 463 × 340 × 248 mm |
| Weight | 16 kg |
| Ambient Operating Temperature | 0–35 °C |
| Relative Humidity | ≤70 % RH |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HNX-2500P |
| Instrument Type | Benchtop Microplate Centrifuge |
| Function | General-purpose microplate centrifugation |
| Max RCF | 797 × g |
| Max Speed | 2500 rpm |
| Capacity | 2 standard microplates (96-well) or deep-well plates |
| Speed Range | 500–2500 rpm |
| RCF Range | 32–797 × g |
| Timer Range | 1–30 min |
| Noise Level | ≤55 dB(A) |
| Multi-step Programming | up to 5 segments |
| Cycle Repetition | up to 99 cycles |
| Auto Re-start After Power Failure | Yes |
| Imbalance Detection | Real-time dynamic monitoring with audible/visual alarm |
| Safety Features | Electronic lid lock, overspeed protection, self-diagnostic system |
| Motor | Brushless DC motor |
| Power Input | AC 220 V, 50–60 Hz |
| Max Power Consumption | 150 W |
| Dimensions (W×D×H) | 463 × 340 × 248 mm |
| Weight | 16 kg |
| Operating Environment | 0–35 °C, ≤70% RH |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HX-2010 |
| Temperature Range | −20 to 105 °C |
| Temperature Stability | ±0.05 °C |
| Bath Volume | 10 L |
| Display Resolution | 0.01 °C |
| Circulation Flow Rate | 16 L/min |
| External Dimensions | 320 × 370 × 670 mm |
| Cooling Method | Air-cooled, hermetically sealed refrigeration compressor |
| Safety Protections | Over-temperature cutoff, refrigeration system overheat & overcurrent protection |
| Calibration Offset Adjustment | Yes |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Nucleic Acid Molecular Hybridization Instrument |
| Model | LF-I |
| Temperature Range | Ambient +5°C to 100°C |
| Temperature Uniformity | ±0.03°C |
| Rotation Speed | 6.5 ± 0.5 rpm |
| Capacity | 6 hybridization tubes (Ø35 × 220 mm) or slides/plates |
| Buffer Volume per Chamber | 100 mL |
| Display Resolution | 0.1°C |
| Temperature Equilibration Time | <20 min |
| Continuous Operation | Up to 24 h |
| Power Supply | 220 VAC, 50 Hz |
| Rated Power | 600 W |
| External Dimensions (W×D×H) | 420 × 380 × 380 mm |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | LF-I |
| Instrument Type | Nucleic Acid Molecular Hybridization Instrument |
| Temperature Range | Room Temperature +5°C to 100°C |
| Temperature Accuracy | ±0.5°C |
| Temperature Uniformity | ±3% |
| Temperature Resolution | 0.1°C |
| Temperature Equilibration Time | <20 min |
| Rotation Speed | 6.5 ± 0.5 rpm |
| Hybridization Tube Capacity | Ø35 × 220 mm |
| Dimensions (L×W×H) | 420 × 380 × 380 mm |
| Power Supply | 220 VAC, 50 Hz |
| Power Consumption | <600 VA |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | LF-IIIN |
| Instrument Category | Nucleic Acid Molecular Hybridization Instrument |
| Temperature Range | RT+5°C to 100°C |
| Temperature Uniformity | ±0.03°C |
| Rotational Speed | 0–99 rpm |
| Temperature Control Accuracy | ±0.5°C |
| Temperature Resolution | 0.1°C |
| Temperature Equilibration Time (at 37°C) | <20 min |
| Display | 7-inch TFT True-Color Touchscreen |
| Max. Operating Time | 999 min 59 sec |
| Programmable Segments | 5 |
| Data Storage Capacity | 50 protocols |
| Hybridization Tube Capacity | 6 or 12 tubes (standard: Ø35×240 mm ×3 |
| optional | Ø35×150 mm / Ø35×300 mm) |
| Base Vibration Intensity | 0–99 levels adjustable |
| Safety Features | Door-open auto-stop, electronic door sensor, tempered glass door with sealing gasket, 3C-certified |
| Chamber Material | 304 stainless steel interior and rack |
| Power Supply | 220 VAC, 50 Hz |
| Rated Power | <800 W |
| Optional Interface | Modbus RTU communication protocol |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | TYZD-III |
| Oscillation Frequency | 10–210 rpm (adjustable) |
| Oscillation Amplitude | 22 mm |
| Timer Range | 0–24 h (countdown mode |
| Platform Dimensions | 384 × 248 mm |
| Power | 15 W |
| Input Voltage | AC 220 V, 50/60 Hz |
| Fuse | 2 A |
| Number of Shaking Platforms | 1 |
| Temperature Control | None |
| Instrument Category | Rotary Oscillator (Non-incubated) |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | ZF-1B |
| Instrument Type | Darkroom-style transilluminator |
| Wavelength Modes | 254 nm (short-wave UV), 365 nm (long-wave UV), and visible light (400–700 nm) |
| UV Lamp Configuration | 6 lamps (3 × 254 nm, 3 × 365 nm) |
| Power Rating | 50 W total (254 nm: 18 W |
| 365 nm | 18 W |
| visible | 14 W) |
| UV Filter Glass Dimensions | 200 × 50 mm |
| UV Blocking Efficiency | >95% attenuation of incident UV radiation by front protective window |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | AS-01-006 |
| Oxygen Inlet Pressure | 50 PSI (fixed) |
| Max Oxygen Flow | 50 LPM (safety-limited) |
| Adjustable O₂ Flow Range | 0–4 LPM |
| Isoflurane Vaporizer Range | 0.5–5.0% |
| CO₂ Absorber Capacity | 3 lb (1.36 kg) |
| Dimensions (L×W×H) | 40 × 35.5 × 85 cm |
| Compliance | ASTM F2739, ISO 80601-2-13, USP <1211>, GLP-ready design |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | CDS 9000 |
| Certification | CE, ISO 13485 |
| Gas Flow Range | 0.2–4 L/min (O₂) |
| Vaporizer | Original 100 Series or TECH3 Isoflurane Vaporizer (≥250 mL, output accuracy ±0.5%) |
| CO₂ Absorbent Canister Capacity | ≥900 mL |
| Pressure Gauge Range | 0–60 cm H₂O |
| Circuit Type | Dual-path F-circuit with integrated Pop-off valve (2 cm H₂O constant negative pressure) |
| Construction | Anodized matte-finish aluminum chassis |
| Compliance | FDA-recognized materials (NASA-derived loop board), USP <1210> compatible design |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | PP35-2P |
| Type | Adherent-cell-specific electroporation electrode |
| Compatibility | Standard 35 mm Petri dishes with 2 mm gap electrodes |
| Application | In situ transfection of monolayer-cultured mammalian cells |
| Configuration | Dual parallel plate electrode assembly |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | Table Top |
| Gas Delivery System | Non-rebreathing, single-circuit |
| Vaporizer Type | TECH3 Isoflurane/Sevoflurane |
| Flow Range | 0–1000 mL/min (O₂) |
| Vapor Output Range | 0.5–5% |
| Weight | ~10 kg (unit + vaporizer) |
| Safety Features | Vaporizer lockout, visual drug level window, activated carbon scavenging system |
| Compliance | ASTM F2749-22 (Anesthetic Equipment), ISO 80601-2-13:2021 (Medical Electrical Equipment – Particular Requirements for Anesthetic Workstations) |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | TC-3000 |
| Input Channels | Single or Triple Thermocouple |
| Temperature Range (Single-Channel) | 25.0–45.0 °C (0.1 °C resolution, Celsius only) |
| Temperature Range (Triple-Channel) | −10.0 to +60.0 °C (14.0 to 140.0 °F), 0.1 °C resolution |
| Sampling Rate | 3 Hz per channel |
| Power Supply | 4 × C-cell batteries (included) |
| Output | Analog voltage output (0–5 V DC, proportional to temperature) |
| Display | Front-panel LCD with manual channel selection |
| Compliance | CE-marked, RoHS-compliant, designed for laboratory use under GLP conditions |
| Brand | HC |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (China) |
| Model | HSP-1000 |
| Price | USD 2,450 (approx.) |
| Automation Level | Semi-Automatic |
| Heating Method | Electric Tubular Heater |
| Max. Sealing Temperature | 200 °C |
| Min. Sealing Temperature | 80 °C |
| Temp. Control Accuracy | ±1 °C |
| Sealing Time Range | 0.5–9.9 s (0.1 s increments) |
| Max. Temperature Drop During Sealing | ≤2 °C |
| Recovery Time to Set Temp. | ≤25 s |
| Power Input | 300 W |
| Dimensions (D×W×H) | 370 × 178 × 330 mm |
| Weight | 11.46 kg |
| Display | OLED |
| Operating Ambient | 10–35 °C, RH ≤70% |
| Power Supply | AC 200–240 V, 50/60 Hz |
| Brand | Heales |
|---|---|
| Origin | Shenzhen, China |
| Model | PW-812 |
| Instrument Type | Multifunctional Plate Washer |
| Wash Head Configuration | 8-channel and 12-channel dual-needle design |
| Wash Solution Channels | 3 (2 detergent solutions + 1 deionized water |
| Soaking Time Range | 0–999 seconds/minutes/hours (user-selectable unit) |
| Wash Cycles | 1–999 cycles adjustable |
| Residual Liquid Volume per Well | <0.7 µL |
| Orbital Shaking Function | Medium speed |
| Plate Compatibility | 96-well and 48-well microplates with flat, U-bottom, V-bottom, and round-bottom well geometries |
| Dispense Volume Range | 50–950 µL/well (50 µL increments) |
| extended range | 0–6000 µL/well (25 µL increments) |
| Dispense Precision | CV <1.5% across 96 wells |
| Aspiration Time | 0.1–99.9 s (0.1 s resolution) |
| Rinse Line Flush Duration | 0–240 s |
| Auto-Rinse Interval for DI Water | 0–20 s |
| Wash Head Positioning Modes | 5 preset vertical alignment options (horizontal, left, center, right, bottom-touch) |
| Brand | Hechuang |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HC-1500T |
| Instrument Type | Ultrasonic Cell Disruptor |
| Temperature Range | 0–120 °C |
| Operating Frequency | 25 kHz |
| Ultrasonic Power Output | 1500 W |
| Sample Volume Capacity | 0.2–2000 mL |
| Control Interface | 7-inch capacitive touchscreen |
| Pulse Mode | Adjustable from 0.1 s to 999.9 s (on/off) |
| Amplitude Compensation | Auto-compensated |
| Transducer Material | PZT ceramic (lead zirconate titanate) |
| Probe Material | ASTM-grade TC4 titanium alloy (Ti-6Al-4V) |
| Standard Probe Diameter | 15 mm (optional: 8/10/12/20 mm) |
| Integrated Cooling Compatibility | Yes |
| Enclosure | Powder-coated steel frame with polymer housing |
| Dimensions (W×D×H) | 350 × 300 × 500 mm |
| Built-in Stainless Steel Vertical Stage | Yes |
| Brand | Hechuang |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HC-2000E |
| Instrument Type | Ultrasonic Cell Disruptor |
| Temperature Range | 0–120 °C |
| Operating Frequency | 20–25 kHz |
| Ultrasonic Power Output | 2000 W |
| Sample Volume Capacity | 0.2–2000 mL |
| Control Interface | 7-inch capacitive touchscreen |
| Pulse Mode Timing | 0.1 s to 999 min (on/off cycles independently configurable) |
| Probe Material | ASTM F136 TC4 titanium alloy |
| Transducer | PZT-4 piezoelectric ceramic (CV33-grade) |
| Amplitude Adjustment | 0–100% continuous |
| Real-time Display | Amplitude %, frequency (Hz), cumulative operating time, temperature (if external probe connected) |
| Brand | Heidolph |
|---|---|
| Origin | Germany |
| Model | Hei-VOLUME Distimatic Pro 24/7 Industrial (A-Series Glass Components) |
| Input Power | 1500 W |
| IP Rating | IP42 (Enclosure & Control Panel) |
| Auto Refill | Yes |
| Auto Condensate Drain | Yes |
| Auto Residue Drain | Yes |
| Touchscreen | 7-inch Movable Touch Interface |
| Compatibility | Hei-VAP Industrial Rotary Evaporators with A1/A2 Glass Sets |
| Material Contact | Chemically Resistant Components Throughout |
| Emergency Stop Button | Optional |
| Brand | HEKA |
|---|---|
| Origin | Germany |
| Model | EPC 10 USB 3.0 |
| Detection Principle | Voltage Clamp & Current Clamp |
| Instrument Type | Fully Automated Electrophysiology Workstation |
| Cell Types | Isolated neurons, cardiomyocytes, and related cell lines |
| Seal Quality | High |
| Success Rate | >90% |
| Recording Channels | 1/2/4/8 |
| Sampling Rate | Up to 2 MHz |
| ADC Channels | 5 |
| DAC Channels | 3 |
| Integrated Data Acquisition | LIH3.x Low-Noise Digitization Engine |
| Software Platform | PATCHMASTER NEXT & FITMASTER NEXT |
| Compliance | Designed for GLP/GMP-aligned electrophysiology workflows |