Life Science Instruments
Filter
Showing 1651–1680 of 7558 results
| Brand | Countstar |
|---|---|
| Origin | Shanghai, China |
| Model | IY1200 |
| Detection Time | <20 s |
| Cell Concentration Range | 5×10⁴–3×10⁷ cells/mL |
| Sample Volume | 20 µL |
| Throughput | 5 samples per run |
| Detectable Cell Size | 2–180 µm |
| Brand | Countstar |
|---|---|
| Origin | Shanghai, China |
| Model | IE1000 |
| Measurement Time | <20 s |
| Cell Concentration Range | 1×10⁴–3×10⁷ cells/mL |
| Sample Volume | 20 µL |
| Throughput | 5 samples per slide |
| Detectable Cell Diameter | 5–180 µm |
| Brand | Countstar |
|---|---|
| Origin | Shanghai, China |
| Model | IA1000 |
| Analysis Time | <20 s |
| Detection Concentration Range | 5×10⁴–5×10⁷ cells/mL |
| Sample Volume | 20 µL |
| Throughput | 5 samples per run |
| Detectable Cell Size Range | 2–180 µm |
| Brand | Countstar |
|---|---|
| Origin | Shanghai, China |
| Model | IM1200 |
| Detection Time | <20 s |
| Cell Concentration Range | 5×10⁴–5×10⁷ cells/mL |
| Sample Volume | 20 µL |
| Throughput | 5 samples per run |
| Detectable Cell Diameter | 2–180 µm |
| Brand | Countstar |
|---|---|
| Origin | Shanghai, China |
| Model | IC1000 |
| Measurement Time | <20 s |
| Cell Concentration Range | 1×10⁴–3×10⁷ cells/mL |
| Sample Volume | 20 µL |
| Throughput | 5 samples per slide |
| Detectable Cell Diameter | 5–180 µm |
| Brand | Countstar |
|---|---|
| Origin | Shanghai, China |
| Model | Castor X |
| Fluorescence Channels | Dual (Green & Red) |
| Compatible Vessels | 6/12/24/96/384-well plates, Petri dishes, culture flasks |
| Imaging Sensor | Cooled high-resolution monochrome CMOS camera |
| Analysis Engine | AI-powered deep learning algorithms for clonal identification, confluency quantification, and transfection efficiency scoring |
| Software | Modular, GLP-compliant with audit trail and user permission management |
| Regulatory Alignment | Designed to support ISO 13485 workflows and FDA 21 CFR Part 11–ready data integrity practices |
| Brand | Countstar |
|---|---|
| Origin | Shanghai, China |
| Model | Mira BF |
| Detection Time | 20–50 s |
| Cell Concentration Range | 1×10⁴ – 3×10⁷ cells/mL |
| Sample Volume | 20 µL |
| Throughput | 5 samples per run |
| Detectable Cell Diameter | 2 – 180 µm |
| Brand | Countstar |
|---|---|
| Origin | Shanghai, China |
| Model | Mira FL |
| Detection Time | 20–50 s |
| Cell Concentration Range | 1×10⁴–3×10⁷ cells/mL |
| Sample Volume | 20 µL |
| Throughput | 5 samples per run |
| Detectable Cell Diameter | 1–180 µm |
| Brand | Countstar |
|---|---|
| Origin | Shanghai, China |
| Model | Mira FL Plus |
| Measurement Time | 20–50 s |
| Cell Concentration Range | 1×10⁴ – 3×10⁷ cells/mL |
| Sample Volume | 20 µL |
| Throughput | 5 samples per run |
| Detectable Cell Size Range | 1–180 µm |
| Imaging Sensor | 8.3 MP CMOS |
| Optical Resolution | Enhanced via fixed-focus optical architecture |
| Fluorescence Channels | AO/PI, GFP, RFP |
| Compliance | FDA 21 CFR Part 11, GMP-aligned data integrity framework |
| Brand | Countstar |
|---|---|
| Origin | Shanghai, China |
| Model | Mira FL Pro |
| Detection Time | 20–50 s |
| Sample Volume | 20 µL |
| Throughput | 5 samples per run |
| Optical Magnification | 10× |
| Imaging Sensor | 8.3 MP CMOS |
| Compatible Consumables | Standard Countstar counting chambers & newly developed 60-µm-depth chambers |
| Regulatory Compliance | FDA 21 CFR Part 11, GMP-aligned |
| Validation Support | Full 3Q (IQ/OQ/PQ) documentation available |
| Data Management | Audit trail, user access control, server & printer integration |
| Brand | Countstar |
|---|---|
| Origin | Shanghai, China |
| Model | Mira HT |
| Detection Concentration Range | 1 × 10⁴ – 3 × 10⁷ cells/mL |
| Sample Volume | 20 µL |
| Throughput | 24 samples (standard) / 15 samples (fluorescence mode) |
| Detectable Cell Size | 1–180 µm |
| Imaging Sensor | 8.3 MP CMOS |
| Optical Resolution | Optimized for ≥2× field area vs. standard hemocytometer |
| Trypan Blue Mode Acquisition Time | <10 s per image |
| AO/PI Dual-Fluorescence Mode Acquisition Time | <22 s per image |
| Total Analysis Time per Sample | <30 s (brightfield), <60 s (fluorescence) |
| Software Compliance | FDA 21 CFR Part 11, GLP/GMP-ready audit trail, 3Q validation support |
| Brand | Countstar |
|---|---|
| Origin | Shanghai, China |
| Model | Rigel |
| Detection Time | <20 s |
| Cell Concentration Range | 1×10⁴–3×10⁷ cells/mL |
| Sample Volume | 20 µL |
| Throughput | 5 samples per run |
| Detectable Cell Diameter | 3–180 µm |
| Fluorescence Channels | Up to 13 (4 excitation sources + 5 emission filter combinations) |
| Regulatory Compliance | CE-marked, FDA 21 CFR Part 11–compliant software architecture |
| Intended Use | Research use only (RUO), not for diagnostic purposes |
| Brand | Countstar |
|---|---|
| Origin | Shanghai, China |
| Model | Countstar Spica |
| Type | Label-Free Live-Cell Imaging System |
| Optical Configurations | Spica M1 (7.5×/10×/15× |
| 3-channel fluorescence | DAPI/GFP/RFP |
| 4-channel fluorescence | DAPI/GFP/RFP/APC |
| Environmental Integration | Incubator-compatible (37 °C, 5% CO₂, humidity control) |
| Software | AI-powered analysis platform with ≥12 pre-validated application modules, FDA 21 CFR Part 11–compliant audit trail (optional), GLP/GMP-ready data export (CSV, TIFF, JSON, PDF) |
| Brand | RWD |
|---|---|
| Origin | Shenzhen, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model Numbers | F31029-15 (15 cm), F31030-16 (16 cm) |
| Pricing | Available Upon Request |
| Brand | Ted Pella |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model Series | CX/CXR |
| Price Range | USD $2,600 – $7,800 |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | CryoMed Programmable Cooling System |
| Pricing | Available Upon Request |
| Brand | AZENTA |
|---|---|
| Origin | USA |
| Model | CryoPod™ Portable Cryogenic Transport Container |
| Temperature Range | ≤ −150 °C (LN₂ vapor phase) |
| Hold Time | > 3 hours at ≤ −150 °C |
| Sample Capacity | Up to two SBS-format cryoboxes (e.g., 250 mL standard boxes) or equivalent trays |
| Data Logging | Timestamped temperature logging with USB data export |
| Alarms | Visual and audible alerts for temperature excursions |
| Weight | < 10 kg |
| Compatibility | Standalone use or integrated with BioStore™ automated sample management system |
| Regulatory Context | Designed for GLP-compliant sample transport |
| Brand | Applitech |
|---|---|
| Material Options | SUS304 Stainless Steel Shell + Optional AbioSafe™ Polypropylene Cryo-Bag |
| Volumes | 4 L, 5 L, 10 L |
| Temperature Range | -80 °C (validated) |
| Reusability | Stainless steel shells — autoclavable and cleanable |
| Compliance | Designed for cGMP-aligned bioprocessing environments |
| Customization | Configurable shell geometry, port layout, and tubing management modules |
| Validation Support | Full DQ/IQ/OQ documentation available for AS-series bags (e.g., AS4L-PM005) and FPS-series shells (e.g., FPS0005-3A, FPS0010-3A) |
| Brand | Cryosafe |
|---|---|
| Origin | USA |
| Model | APP-1 |
| Capacity | 165 L |
| Evaporation Rate | 5 L/day |
| Standby Duration | 33 days |
| Inner Diameter | 533 mm |
| External Dimensions (L×W×H) | 775×587×1118 mm |
| Empty Weight | 111 kg |
| Full Weight | 243 kg |
| System Capacity | 10,400 cryovials |
| Insulation Thickness | 18 cm polyurethane foam lid |
| Control System | Auto Protector Plus with 7-level liquid level sensing, dual independent temperature monitoring (sample & vapor phase), uninterruptible power backup (3–5 days), auto-defogging, rapid cooldown recovery, and 9-point alarm logic |
| Brand | Cryosafe |
|---|---|
| Origin | USA |
| Model | Auto Basic |
| Liquid Nitrogen Capacity | 165 L (AB-1) / 365 L (AB-2) |
| Evaporation Rate | 5 L/day (AB-1) / 7 L/day (AB-2) |
| Hold Time | 33 days (AB-1) / 52 days (AB-2) |
| Maximum Sample Capacity | 10,400 vials (AB-1) / 24,050 vials (AB-2) |
| Neck Opening Diameter | 533 mm (AB-1) / 787 mm (AB-2) |
| External Dimensions (L×W×H) | 775×587×1118 mm (AB-1) / 965×864×1118 mm (AB-2) |
| Usable Height | 737 mm (both models) |
| Empty Weight | 111 kg (AB-1) / 184 kg (AB-2) |
| Full Weight | 243 kg (AB-1) / 474 kg (AB-2) |
| Shipping Weight | 182 kg (AB-1) / 291 kg (AB-2) |
| Brand | Cryosafe |
|---|---|
| Origin | USA |
| Model | CG-1 |
| Capacity | 46 L (below rotary rack) / 407 L (total) |
| Evaporation Rate | 8 L/day |
| Hold Time | 33 days |
| External Dimensions | 864 mm (Ø) × 1524 mm (H) |
| Net Weight | 295 kg |
| Operating Temperature | ≤ −135 °C (vapor phase) |
| Control System | Auto Protector Plus with 7-level capacitive liquid level sensors, dual temperature monitoring (sample & vapor), RS232 data logging, 3–5 day battery backup |
| Brand | Cryosafe |
|---|---|
| Origin | USA |
| Model | CryoMizer |
| Capacity Options | CM-1 / CM-2 / CM-3 / CM-4 |
| Operating Modes | Vapor-phase (−135 °C) and Liquid-phase (−196 °C) Storage |
| Standard Configuration | Cryogenic Rack System, Castor-Mounted Base, LN₂ Level Gauge |
| Compliance | Designed for GLP/GMP-aligned biobanking workflows |
| Brand | Cryosafe |
|---|---|
| Origin | USA |
| Model | SSC |
| Price | $4,000 |
| Capacity Range | 20.5–47.4 L |
| Evaporation Rate | 0.095–0.39 L/day |
| Holding Time | 53–193 days |
| Canister Capacity | 210–5,216 × 0.5 mL straws (loose) |
| Neck Diameter | 55.4–127 mm |
| Height | 438–875 mm |
| Outer Diameter | 368–508 mm |
| Empty Weight | 10.5–19 kg |
| Full Weight | 27–54.6 kg |
| Brand | Cryosafe |
|---|---|
| Origin | USA |
| Model | SSC-ET |
| Liquid Nitrogen Capacity | 3.6–36.5 L |
| Evaporation Rate | 0.09–0.15 L/day |
| Static Hold Time | 54–224 days |
| Outer Diameter | 222–464 mm |
| Height | 406–690 mm |
| Neck Diameter | 51 mm |
| Bucket Quantity | 6–60 |
| 0.5 mL Straws (Loose) | 732–7800 |
| Empty Weight | 3.6–15.4 kg |
| Full Weight | 6.5–44.8 kg |
| Compliance | Designed for ISO 13485-aligned biobanking workflows, compatible with GLP/GMP sample integrity requirements |
| Brand | Cryosafe |
|---|---|
| Origin | USA |
| Model | T-cryo |
| Type | Auto-fill Biological LN₂ Storage Tank |
| Capacity | 165 L |
| Evaporation Rate | 0.84 L/day |
| Hold Time | 194 days (typical) |
| Sample Capacity | 7,000 × 2 mL vials |
| Vapor Phase Temp | −135 °C |
| Liquid Phase Temp | −185 °C |
| Neck Opening Diameter | 216 mm |
| Height | 991 mm |
| Outer Diameter | 683 mm |
| Empty Weight | 55 kg |
| Full Weight | 186.4 kg |
| Shipping Weight | 114 kg |
| Standard Configuration Includes | Main tank, Auto-Tend auto-fill system, cryogenic racks, castor-mounted base, and supply hose |
| Brand | Cryosafe |
|---|---|
| Origin | USA |
| Model | VS |
| Liquid Nitrogen Capacity | 1.5–12.3 L |
| Evaporation Rate | 0.09–0.85 L/day |
| Operating Temperature | ≤ –185 °C |
| Brand | Shanghai Shiping |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Air-Jacketed CO₂ Incubator |
| CO₂ Sensing Method | Gas-Phase Infrared Detection |
| Temperature Range & Accuracy | RT+3°C to 60°C, ±0.1°C |
| Temperature Uniformity | ±0.3°C (at 37°C) |
| CO₂ Concentration Range & Accuracy | 0–20%, ±0.1% |
| Humidity Control | ≥95% RH (via water-jacketed humidification) |
| Chamber Volume | 175 L |
| External Dimensions (W×D×H) | 680 × 685 × 900 mm |
| Sterilization Mode | 90°C High-Temperature Humid Heat Cycle |
| Compliance | ISO 9001 Certified Manufacturing |
| Key Features | 7-inch Color Touchscreen (Bilingual UI), Triple-Level User Access Control, HEPA-Filtered Air Circulation (ISO Class 5 / Grade A Equivalent), 304 Mirror-Finish Stainless Steel Interior, Forced-Air Convection with Optimized Duct Design, Outer Door Heating, USB Data Export & Audit Trail Logging |
| Brand | Oxford Lab Technologies |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Crystal Shifter |
| Pricing | Available Upon Request |
| Brand | CS Bio |
|---|---|
| Origin | USA |
| Model | CS536 Series |
| Synthesis Scale | Pilot-scale |
| Reactor Volume Range | 50 mL to 1 L |
| Stirring Options | 180° Tilt-based Mixing or Overhead Stirring |
| Intended Use | Process Development & Scale-up Studies |
| Distribution Status | Authorized Distributor (Non-OEM) |
| Brand | CS Bio |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CSBIO II |
| Price Range | USD 42,000 – 70,000 |