Liquid Chromatograph
Filter
Showing 271–300 of 353 results
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Vanquish |
| Instrument Type | Ultra-High Performance Liquid Chromatograph (UHPLC) |
| Flow Rate Range | 0.001–5.000 mL/min |
| Maximum Operating Pressure | 150 MPa (22,000 psi) |
| Sample Capacity | 8832 positions |
| Injection Volume Range | 0.01–100 µL |
| Column Oven Temperature Range | 5–120 °C |
| Data Acquisition Rate | 200 Hz |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Accela |
| Price Range | USD 28,000 – 70,000 |
| Instrument Type | Ultra-High-Performance Liquid Chromatograph (UHPLC) |
| Maximum Operating Pressure | 1250 bar (18,130 psi) |
| Flow Rate Range | 0.001–2.000 mL/min |
| Gradient Delay Volume | ≤70 µL |
| Flow Accuracy | ≤±0.5% |
| Gradient Accuracy | ≤±0.5% |
| Pressure Ripple | <0.5 bar (peak-to-peak) |
| Typical Peak Width (FWHM) | <1 s |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model Series | TSP P1500 (Quaternary Pump), UV1000 (Variable Wavelength Detector), AS3000 (Autosampler) |
| Compliance | CE, UL, RoHS |
| Operating Pressure Range | Up to 400 bar |
| Flow Rate Range | 0.001–10.000 mL/min |
| Wavelength Range (UV1000) | 190–700 nm |
| Detection Limit (UV1000) | < 5 × 10⁻⁹ g/mL (caffeine, 254 nm) |
| Injection Volume Range (AS3000) | 0.1–100 µL |
| Precision (RSD) | ≤ 0.3% for retention time, ≤ 0.5% for peak area |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model Series | P4000, AS 3000, UV 1000 |
| Compliance | CE, UL, RoHS |
| Flow Rate Range | 0.001–10.000 mL/min |
| Pressure Rating | Up to 400 bar |
| Gradient Accuracy | ≤0.2% RSD |
| Pulse Dampening | Active electronic compensation |
| Solvent Compatibility | HPLC-grade aqueous/organic solvents (including THF, DCM, DMF) |
| Communication Interface | RS-232, CAN bus, optional Ethernet (via TSP Control Hub) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Vanquish Charged Aerosol Detector P Series |
| Instrument Type | Conventional High-Performance Liquid Chromatography (HPLC) Detector |
| Application Scope | Universal Detection |
| Flow Rate Range | 0.01–2.0 mL/min |
| Temperature Control Range | 10–100 °C |
| Data Acquisition Frequency | 200 Hz |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Product Category | Imported Instrument |
| Model | Vanquish Core |
| Instrument Type | Ultra-High-Performance Liquid Chromatograph (UHPLC) |
| Maximum Operating Pressure | 700 bar |
| Column Oven Temperature Range | 5 °C to 85 °C |
| Data Acquisition Rate | 125 Hz |
| System Configuration Options | Quaternary, Binary, and Isocratic Configurations |
| Brand | Thermo Scientific |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Vanquish Core |
| Instrument Type | Ultra-High-Performance Liquid Chromatograph (UHPLC) |
| Launch Date | March 2020 |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Vanquish Flex Binary UHPLC System |
| Price Range | USD 65,000 – 130,000 |
| Instrument Type | Ultra-High Performance Liquid Chromatograph (UHPLC) |
| Maximum Pressure | 1000 bar (15,000 psi) |
| Flow Rate Range | 0.001–8.0 mL/min |
| Solvent Channels | 6 |
| Injector Capacity | 208 injections (single vial) |
| Column Oven Temperature Range | 5–120°C (dual-mode: static air + forced-air circulation) |
| Detection Options | Diode Array (DAD), Fluorescence (FLR), Electrospray Ionization (ESI) Charged Aerosol Detection (CAD), and MS-coupling ready |
| Brand | Thermo Scientific |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Vanquish |
| Instrument Type | Ultra-High Performance Liquid Chromatograph |
| Flow Rate Range | 0.001–5.000 mL/min |
| Maximum Pressure | 150 MPa |
| Sample Tray Capacity | 8832 positions |
| Injection Volume Range | 0.01–100 µL |
| Column Oven Temperature Range | 5–120 °C |
| Data Acquisition Rate | 200 Hz |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Ultra-High Performance Liquid Chromatograph (UHPLC) |
| Model | LC-8000 |
| Flow Rate Range | 0.01–10.000 mL/min (0.001 mL/min increment) |
| Maximum Operating Pressure | 10,500 PSI (72 MPa) at 0–2 mL/min |
| Flow Accuracy | ≤0.06% RSD |
| Autosampler Capacity | ≥108 positions (1.5 mL vials) |
| Injection Volume Range | 20–100 µL |
| Column Oven Temperature Range | Ambient +5 °C to 85 °C |
| UV-Vis Detector Wavelength Range | 190–900 nm |
| Data Acquisition Rate | 100 Hz |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Ultra-High Performance Liquid Chromatograph (UHPLC) |
| Model | LC-8000 |
| Pressure Range | Up to 70 MPa |
| Column Compatibility | Supports 2 µm particle-packed columns |
| Flow Pulsation | <10 psi (PPRC technology) |
| Column Oven Capacity | Accommodates up to six 250 mm columns simultaneously |
| Temperature Uniformity | ±0.1 °C (forced-air circulation + high-precision PID control) |
| Autosampler Wash | Dual-needle displacement cleaning mechanism |
| Data Acquisition Rate | Up to 100 Hz |
| Regulatory Compliance | FDA 21 CFR Part 11, GLP, GMP |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Model | SA-50 |
| Instrument Type | Ultra-High Performance Liquid Chromatography–Atomic Fluorescence Spectrometry System |
| Application Scope | Elemental Speciation Analysis |
| Configuration | Modular, Integrated LC Pump(s), Dual-Column Oven, Column Switching Valve, UV Photochemical Reactor with Auto-Activation, Four-Channel Peristaltic Pump, LED Status Indicators, Optional Autosampler (96-/120-position) |
| Software | Unified Control Platform for Total Element and Speciation Quantification, Method Management, Hybrid Sequence Scheduling, Real-Time Instrument Monitoring, System Self-Diagnosis, Customizable Reporting Templates |
| Compliance Framework | Designed to support GLP/GMP-aligned workflows |
| Brand | Wooking |
|---|---|
| Model | 2D-HPLC |
| Type | Multidimensional Liquid Chromatograph |
| Origin | Shandong, China |
| Supplier Type | Authorized Distributor |
| Regional Classification | Domestically Manufactured Instrument |
| Pricing | Available Upon Request |
| Brand | Ulink Optoelectronics |
|---|---|
| Origin | Beijing, China |
| Model | UC-3220 |
| Instrument Type | Conventional High-Performance Liquid Chromatograph |
| Flow Rate Range | 0.001–9.999 mL/min |
| Pump Configuration | Dual-piston serial design with electronic pressure pulsation suppression |
| Flow Accuracy | <0.4% RSD at 1 mL/min (deionized water, 25°C) |
| Flow Precision | 0.1% RSD at 1 mL/min (deionized water, 25°C) |
| Maximum Pressure | 40 MPa at 1 mL/min (deionized water, 25°C) |
| Pressure Pulsation | <0.05 MPa at 1 mL/min (deionized water, 25°C) |
| Gradient Accuracy | ±1% (optional binary low-pressure gradient module) |
| Wavelength Range | 190–740 nm |
| Light Source | Deuterium lamp |
| Wavelength Accuracy | ±1 nm |
| Spectral Scanning Mode | Stop-flow automatic scan |
| Baseline Noise | 2×10⁻⁵ AU at 240 nm (25°C) |
| Baseline Drift | 15×10⁻⁵ AU/h at 240 nm (25°C) |
| LOD | 5×10⁻⁹ g/mL (naphthalene standard, methanol mobile phase, 254 nm, 25°C) |
| Control Interface | RS-232 for full bidirectional computer control |
| Display | 2×16-character LCD (English) |
| Power Supply | 220 V AC, 3 A, 200 W |
| Dimensions (L×H×D) | 306×210×420 mm |
| Weight | 12 kg |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | UC-3220A |
| Instrument Type | Conventional HPLC System |
| Flow Rate Range | 0.001–9.999 mL/min |
| Pump Configuration | Dual-piston serial design with electronic pressure pulsation suppression |
| Flow Accuracy | <0.4% RSD (1 mL/min, deionized water, 25 °C) |
| Flow Precision | 0.1% RSD (1 mL/min, deionized water, 25 °C) |
| Maximum Pressure | 40 MPa (1 mL/min, deionized water, 25 °C) |
| Pressure Pulsation | <0.05 MPa (1 mL/min, deionized water, 25 °C) |
| Gradient Accuracy | ±1% |
| Autosampler | XYZ robotic arm configuration (standard) |
| Sample Capacity | 120 × 1.8 mL vials |
| Sample Tray Temperature Control | 4–40 °C |
| Injection Precision | 0.5% RSD (254 nm, 20 µL naphthalene standard in methanol, 1 mL/min) |
| UV-Vis Wavelength Range | 190–740 nm |
| Light Source | Deuterium lamp |
| Wavelength Accuracy | ±1 nm |
| Spectral Scanning Mode | Stop-flow automatic scan |
| Baseline Noise | 2 × 10⁻⁵ AU (254 nm, 25 °C) |
| Baseline Drift | 15 × 10⁻⁵ AU/h (254 nm, 25 °C) |
| LOD | 5 × 10⁻⁹ g/mL (254 nm, naphthalene standard in methanol, 25 °C) |
| Communication Interface | RS-232 for full bidirectional instrument control |
| Display | 4.3-inch TFT color touchscreen |
| Power Supply | 220 V AC, 3 A |
| Dimensions (W × H × D) | 320 × 430 × 430 mm |
| Weight | 25 kg |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | UC-3230A |
| Instrument Type | Conventional HPLC System |
| Flow Rate Range | 0.001–9.999 mL/min |
| Pump Configuration | Dual-piston series design with electronic pressure pulsation suppression |
| Flow Accuracy | <0.4% RSD at 1 mL/min (deionized water, 25°C) |
| Flow Precision | ≤0.1% RSD at 1 mL/min (deionized water, 25°C) |
| Maximum Pressure | 40 MPa at 1 mL/min (deionized water, 25°C) |
| Pressure Pulsation | <0.05 MPa peak-to-peak at 1 mL/min (deionized water, 25°C) |
| Autosampler | XYZ robotic arm configuration (standard) |
| Sample Capacity | 120 × 1.8 mL vials |
| Sample Tray Temperature Control | 4–40°C (Peltier-cooled, optional) |
| Injection Repeatability | ≤0.5% RSD (254 nm, 20 µL naphthalene standard in methanol, 1 mL/min) |
| UV-Vis Detector Wavelength Range | 190–740 nm |
| Light Source | Deuterium lamp |
| Wavelength Accuracy | ±1 nm |
| Spectral Scan Mode | Stop-flow automated scanning |
| Baseline Noise | ≤2 × 10⁻⁵ AU at 254 nm (25°C, 1 s response) |
| Baseline Drift | ≤15 × 10⁻⁵ AU/h at 254 nm (25°C, 1 h) |
| LOD (Naphthalene) | 5 × 10⁻⁹ g/mL at 254 nm (methanol mobile phase, ambient temperature) |
| Communication Interface | RS-232 (full bidirectional instrument control) |
| Display | 4.3-inch TFT true-color touchscreen |
| Power Supply | 220 V AC, 3 A |
| Dimensions (W×H×D) | 390 × 800 × 430 mm |
| Weight | 35 kg |
| Brand | Youlian Optoelectronics |
|---|---|
| Origin | Beijing, China |
| Model | UC-3232 |
| Instrument Type | Conventional HPLC System |
| Flow Rate Range | 0.001–9.999 mL/min |
| Maximum Pressure | 42 MPa |
| Wavelength Range | 190–740 nm |
| Data Acquisition Frequency | 10 Hz |
| Flow Accuracy | <0.4% RSD (at 1 mL/min, deionized water, 25°C) |
| Flow Precision | 0.1% RSD (at 1 mL/min, deionized water, 25°C) |
| Pressure Pulsation | <0.05 MPa (at 1 mL/min, deionized water, 25°C) |
| Gradient Accuracy | ±1% |
| Wavelength Accuracy | ±1 nm |
| Baseline Noise | 2×10⁻⁵ AU (240 nm, 25°C) |
| Baseline Drift | 15×10⁻⁵ AU/h (240 nm, 25°C) |
| LOD | 5×10⁻⁹ g/mL (naphthalene, 254 nm, methanol mobile phase, 25°C) |
| Brand | Youlian Optoelectronics |
|---|---|
| Origin | Beijing, China |
| Model | UC-3268 |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (PRC) |
| Pricing | Available Upon Request |
| Brand | Youlian Optoelectronics |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (PRC) |
| Model | UC-3269 |
| Pricing | Available Upon Request |
| Brand | Ulion |
|---|---|
| Model | UC-3283d |
| Origin | Beijing, China |
| Pump Type | Dual-piston serial reciprocating pump |
| Flow Rate Range | 0.001–9.999 mL/min (with 10 mL pump head) |
| Flow Accuracy | <0.4% RSD |
| Flow Precision | ±0.1% RSD |
| Pressure Range | 0–40 MPa |
| Pressure Pulsation | <0.05 MPa (deionized water, 1 mL/min at 10 MPa) |
| Control Interface | RS-232 |
| Display | 2×16-character LCD |
| Dimensions (L×H×D) | 306×210×420 mm |
| Weight | 3.8 kg |
| Brand | UltimateChrom |
|---|---|
| Model | UC-3233 |
| Configuration | Modular Isocratic HPLC System |
| Pump Type | Dual-Piston Series High-Pressure Solvent Delivery |
| Flow Rate Range | 0.001–9.999 mL/min |
| Flow Accuracy | <0.4% RSD at 1 mL/min (deionized water, 25 °C) |
| Flow Precision | ≤0.1% RSD at 1 mL/min |
| Maximum Pressure | 40 MPa |
| Pressure Pulsation | <0.05 MPa |
| UV-Vis Detector Wavelength Range | 190–740 nm |
| Light Source | Deuterium Lamp |
| Wavelength Accuracy | ±1 nm |
| Spectral Scan Mode | Stop-Flow Auto-Scan |
| Baseline Noise | 2×10⁻⁵ AU (240 nm, 25 °C) |
| Baseline Drift | 15×10⁻⁵ AU/h (240 nm, 25 °C) |
| LOD | 5×10⁻⁹ g/mL (naphthalene, 254 nm, methanol mobile phase) |
| Control Interface | RS-232 |
| Display | 2×16 Character LCD (English) |
| Brand | UltimateChrom |
|---|---|
| Model | UC-3234 |
| Instrument Type | Conventional High-Performance Liquid Chromatograph |
| Flow Rate Range | 0.001–9.999 mL/min |
| Pump Architecture | Dual-plunger serial configuration with electronic pressure pulsation suppression |
| Flow Accuracy | <0.4% RSD at 1 mL/min (deionized water, 25 °C) |
| Flow Precision | 0.1% RSD at 1 mL/min (deionized water, 25 °C) |
| Maximum Operating Pressure | 40 MPa at 1 mL/min (deionized water, 25 °C) |
| Pressure Pulsation | <0.05 MPa peak-to-peak at 1 mL/min (deionized water, 25 °C) |
| Gradient Accuracy | ±1% |
| Wavelength Range | 190–740 nm |
| Light Source | Deuterium lamp |
| Wavelength Accuracy | ±1 nm |
| Spectral Scanning Mode | Stop-flow automated scan |
| Baseline Noise | 2×10⁻⁵ AU at 240 nm (25 °C, 1 s time constant) |
| Baseline Drift | 15×10⁻⁵ AU/h at 240 nm (25 °C) |
| LOD (Naphthalene) | 5×10⁻⁹ g/mL at 254 nm (methanol mobile phase, ambient temperature) |
| Control Interface | RS-232 for full bidirectional instrument control |
| Display | 2×16-character LCD with English interface |
| Brand | UltimateChrom |
|---|---|
| Model | UC-3235 |
| Instrument Type | Conventional High-Performance Liquid Chromatograph |
| Flow Rate Range | 0.001–9.999 mL/min |
| Pump Architecture | Dual-plunger serial configuration with electronic pressure pulsation suppression |
| Flow Accuracy | <0.4% RSD at 1 mL/min (deionized water, 25 °C) |
| Flow Precision | 0.1% RSD at 1 mL/min (deionized water, 25 °C) |
| Maximum Pressure | 40 MPa at 1 mL/min (deionized water, 25 °C) |
| Pressure Pulsation | <0.05 MPa peak-to-peak at 1 mL/min (deionized water, 25 °C) |
| Gradient Accuracy | ±1% |
| Wavelength Range | 190–740 nm |
| Light Source | Deuterium lamp |
| Wavelength Accuracy | ±1 nm |
| Spectral Scan Mode | Stop-flow automatic scan |
| Baseline Noise | 2×10⁻⁵ AU at 240 nm (25 °C) |
| Baseline Drift | 15×10⁻⁵ AU/h at 240 nm (25 °C) |
| LOD | 5×10⁻⁹ g/mL (naphthalene standard, methanol mobile phase, 254 nm, 25 °C) |
| Communication Interface | RS-232 for full bidirectional instrument control |
| Display | 2×16-character LCD with English interface |
| Brand | UltimateOpto |
|---|---|
| Model | UC-3210 |
| Instrument Type | Conventional High-Performance Liquid Chromatograph |
| Flow Rate Range | 0.001–9.999 mL/min |
| Pump Type | Dual-Piston Series Configuration with Electronic Pressure Pulsation Damping |
| Flow Accuracy | <0.4% RSD at 1 mL/min (deionized water, 25 °C) |
| Flow Precision | 0.1% RSD at 1 mL/min (deionized water, 25 °C) |
| Maximum Pressure | 40 MPa at 1 mL/min (deionized water, 25 °C) |
| Pressure Pulsation | <0.05 MPa at 1 mL/min (deionized water, 25 °C) |
| Gradient Accuracy | ≤1% |
| Wavelength Range | 190–740 nm |
| Light Source | Deuterium Lamp |
| Wavelength Accuracy | ±1 nm |
| Spectral Scanning | Stop-Flow Auto-Scan |
| Baseline Noise | 2×10⁻⁵ AU at 240 nm (25 °C) |
| Baseline Drift | 15×10⁻⁵ AU/h at 240 nm (25 °C) |
| LOD | 5×10⁻⁹ g/mL (naphthalene, 254 nm, methanol mobile phase, 25 °C) |
| Interface | RS-232 |
| Display | 5.6-inch color TFT LCD |
| Power Supply | 220 V AC, 180 W |
| Dimensions (W×H×D) | 400×480×360 mm |
| Weight | 32 kg |
| Brand | UltimateOpto |
|---|---|
| Model | UC-3218 |
| Instrument Type | Conventional High-Performance Liquid Chromatograph |
| Flow Rate Range | 0.001–9.999 mL/min |
| Pump Type | Dual-Piston Series Configuration with Electronic Pressure Pulsation Damping |
| Flow Accuracy | <0.4% RSD (at 1 mL/min, deionized water, 25 °C) |
| Flow Precision | 0.1% RSD (at 1 mL/min, deionized water, 25 °C) |
| Maximum Pressure | 40 MPa (at 1 mL/min, deionized water, 25 °C) |
| Pressure Pulsation | <0.05 MPa (at 1 mL/min, deionized water, 25 °C) |
| Gradient Accuracy | ±1% |
| Autosampler | XYZ-Driven Robotic Sampler (120 positions for 1.8 mL vials) |
| Sample Tray Temperature Control | 4–40 °C |
| Injection Reproducibility | 0.5% RSD (20 µL naphthalene standard at 254 nm, methanol mobile phase, 1 mL/min) |
| UV-Vis Detector Wavelength Range | 190–740 nm |
| Light Source | Deuterium Lamp |
| Wavelength Accuracy | ±1 nm |
| Spectral Scanning Mode | Stop-Flow Auto-Scan |
| Baseline Noise | 2 × 10⁻⁵ AU (240 nm, 25 °C) |
| Baseline Drift | 15 × 10⁻⁵ AU/h (240 nm, 25 °C) |
| LOD | 5 × 10⁻⁹ g/mL (naphthalene, 254 nm, methanol, 25 °C) |
| Communication Interface | RS-232 |
| Display | 5.6-inch True-Color TFT LCD |
| Power Supply | 220 V AC, 3 A |
| Dimensions (W×H×D) | 650 × 410 × 465 mm |
| Weight | 35 kg |
| Brand | Ultron |
|---|---|
| Origin | Beijing, China |
| Model | UC-3231 |
| Instrument Type | Conventional HPLC System |
| Flow Rate Range | 0.001–9.999 mL/min |
| Max Operating Pressure | 40 MPa |
| Wavelength Range | 190–740 nm |
| Spectral Bandwidth | 20 nm |
| Baseline Noise | 4×10⁻⁵ AU (MeOH, 1 mL/min) |
| Baseline Drift | 3×10⁻⁴ AU (MeOH, 1 mL/min) |
| LOD | 2×10⁻⁸ g/mL (naphthalene in MeOH, 1 mL/min) |
| Data Acquisition Rate | 10 Hz |
| Pump Type | Dual-piston serial configuration with electronic pressure pulsation suppression |
| Detector Light Source | Low-pressure mercury lamp (5,000 h lifetime) |
| Control Interface | RS-232 |
| Display | 2×8-character LCD |
| Brand | Ultron |
|---|---|
| Origin | Beijing, China |
| Model | UC-3282 |
| Flow Rate Range | 0.001–9.999 mL/min (10 mL pump head) |
| Pump Type | Dual-piston serial reciprocating pump |
| Flow Accuracy | <0.5% |
| Flow Precision (RSD) | ≤0.1% |
| Pressure Pulsation | <0.1 MPa (deionized water, 1 mL/min at 10 MPa |
| Maximum Operating Pressure | 0–40 MPa (standard), 0–25 MPa (low-pressure configuration) |
| Remote Control Interface | RS-232 |
| Pressure Limit Protection | User-definable upper threshold |
| Display | 2×16-character LCD (English) |
| GLP Functionality | Solvent consumption logging |
| Dimensions (L×H×D) | 200×210×420 mm |
| Weight | 7.5 kg |
| Brand | Ulunion |
|---|---|
| Model | UC-3283 |
| Origin | Beijing, China |
| Pump Type | Dual-Piston Serial Reciprocating Pump |
| Flow Rate Range | 0.001–9.999 mL/min (10 mL pump head) / 0.01–49.99 mL/min (50 mL pump head) |
| Flow Accuracy | <0.5% RSD |
| Flow Precision | ≤0.1% RSD |
| Pressure Pulsation | <0.1 MPa (deionized water, 1 mL/min @ 10 MPa |
| Maximum Pressure | 0–40 MPa (standard), 0–25 MPa (low-pressure configuration) |
| Control Interface | RS-232 for PC-based remote control and bidirectional communication |
| System Protection | User-configurable pressure limit cutoff |
| Display | 2×16-character LCD with English interface |
| GLP Functionality | Cumulative solvent consumption logging |
| Dimensions (L×H×D) | 306 × 210 × 420 mm |
| Weight | 10 kg |
| Brand | Unimicro Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Conventional High-Performance Liquid Chromatograph |
| Model | EasySep-1010 |
| Pump Types | Analytical (10 mL stainless steel head) & Semi-Preparative (50 mL stainless steel head) |
| Flow Range (Analytical) | 0.01–9.99 mL/min |
| Max Pressure (Analytical, SS) | 42 MPa |
| Flow Range (Semi-Prep) | 0.1–49.9 mL/min |
| Max Pressure (Semi-Prep, SS) | 30 MPa |
| Flow Accuracy (Analytical) | RSD ≤ 0.5% at 1 mL/min |
| Flow Precision (Analytical) | RSD ≤ 0.1% at 1 mL/min |
| Flow Accuracy (Semi-Prep) | RSD ≤ 2% at 1 & 10 mL/min |
| Flow Precision (Semi-Prep) | RSD ≤ 0.5% at 1 & 10 mL/min |
| UV-VIS Detector | Wavelength Range 190–360 nm |
| Wavelength Accuracy | ≤ ±1 nm |
| Spectral Bandwidth | 8 nm |
| Wavelength Repeatability | ≤ ±0.1 nm |
| Light Source | DX2 Dual-Life Deuterium Lamp |
| Detector Cell Options | Analytical & Semi-Preparative Flow Cells |
| Display | 320×240 dot-matrix LCD |
| System Protection | Soft-start/stop, programmable pressure limits, auto data backup |
| Brand | Unimicro Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Regional Classification | Domestic (China) |
| Model | EasySep-1020 HPLC |
| Instrument Category | Conventional High-Performance Liquid Chromatograph |
| Application Scope | General-Purpose Analytical Use |
| Flow Rate Range | 0.001–9.999 mL/min |
| Maximum Operating Pressure | 42 MPa |
| Flow Accuracy | <0.06% RSD |
| Autosampler Capacity | 120 positions |
| Injection Volume Range | 0.1–250 µL |
| Column Oven Temperature Range | Ambient +10 °C to 60 °C |
| UV/Vis Wavelength Range | 190–600 nm |
| Data Acquisition Rate | 100 Hz |